8WH6 iPo Plug-In Terminals 2 2/2 Introduction 2/3 General data 2/4 8WH6 through-type terminals 2/8 8WH6 fuse terminals 2/9 8WH6 isolating blade terminals 2/11 8WH6 isolating terminals 2/13 8WH6 two-tier terminals More technical product information: Service&Support Portal: www.support.automation.siemens.com Product List: Technical specifications Entry List: Updates / Downloads / FAQ / Manuals / Operating instructions / Characteristic curves / Certificates 2 8WH6 iPo Plug-In Terminals 2 Introduction ■ Overview 2/2 Devices Page Function Through-type terminals 2/4 Connection of incoming and outgoing conductors Fuse terminals 2/8 Terminals which can be used to protect control circuits, for example Isolating blade terminals 2/9 Isolation of the circuit, e.g. for test purposes Isolating terminals 2/11 Isolation of the circuit, e.g. for test purposes Two-tier terminals 2/13 Compact form of the terminal blocks in which two connection wires can be installed 8WH6 iPo Plug-In Terminals General data ■ Overview iPo connection method: Characterized by its simple and direct conductor connection, this series utilizes all the benefits of the 8WH system. Easy bridging: The double bridge shaft supports the interconnection of any number of terminals using 2-pole jumpers. The 2pole to 50-pole jumpers enable up to 50 terminals to be connected in a single step. Super-light insertion: With an up to 50% lower insertion force, the iPo connection method permits easy and direct insertion of rigid and flexible conductors with end sleeves with a cross-section of more than 0.34 mm2. Pusher button function: The actuation button is used to open the spring to either release the conductor or to connect smaller cross-sections from 0.14 mm2. It can be operated by any tool. 2/3 2 8WH6 iPo Plug-In Terminals 2 8WH6 through-type terminals ■ Overview 8WH6 through-type terminals are ideal for the direct tool-free wiring of conductors with end sleeve or rigid conductors. Easy insertion of flexible conductors with end sleeves upwards of 0.34 mm2. The actuation button can be used to open the clamping point with any type of screwdriver in order to unwire or wire small conductors. The compact design and front connection permit wiring in the narrowest of spaces. The double bridge shaft enables fast creation of an individual potential distribution and infeed, e.g. using a screw terminal. A label can be snapped on to the middle of each terminal at the front. Further labels can also be mounted flat on the side of the terminals. ■ Technical specifications 8WH6 000-0AF00 8WH6 000-0AF01 8WH6 003-0AF00 8WH6 003-0AF01 8WH6 004-0AF00 8WH6 004-0AF01 Dimensions • Width/length/height (NS 35/7.5) in mm 5.2 / 48.5 / 36.5 5.2 / 60.5 / 36.5 5.2 / 72 / 36.5 Max. electrical data • Imax in A • Umax in V • Max. Ø in mm2 • AWG 30 800 0.14 ... 4 26-12 301) Rating according to IEC 60947-7-1 • Rated voltage in V (IEC / UL/CSA) • Rated current in A / cross-section in mm² - IEC - UL/CSA • Nominal cross-section in mm² • AWG cross-section range (IEC / UL/CSA) Connection capacities • 1 conductor - Rigid in mm² - Flexible in mm² - Flexible end sleeve with/without plastic sleeve in mm² • Conductor cross-section, direct plug-in - Rigid in mm² - Flexible end sleeve with/without plastic sleeve in mm² General data • Stripped length in mm • Molded plastic • Flammability class acc. to UL 94 1) 800 / 600 24 / 2.5 20 / -2.5 26-12 / 24-12 0.14 ... 4 0.14 ... 2.5 0.14 ... 2.5 0.34 ... 4 0.34 ... 2.5 10 PA V0 The total current through all connected conductors must not exceed the max. load current. 2/4 800 / -241) / 2.5 -26-12 / -- 8WH6 iPo Plug-In Terminals 8WH6 through-type terminals 8WH6 000-0CF07 8WH6 003-0CF07 8WH6 004-0CF07 Dimensions • Width/length/height (NS 35/7.5) in mm 5.2 / 48.5 / 36.5 5.2 / 60.5 / 36.5 5.2 / 72 / 36.5 Max. electrical data • Max. Ø in mm2 • AWG 0.14 ... 4 26-12 Rating according to IEC 60947-7-1 • Nominal cross-section in mm² • AWG cross-section range (IEC / UL/CSA) 2.5 26-12 / 24-12 Connection capacities • 1 conductor - Rigid in mm² - Flexible end sleeve with/without plastic sleeve in mm² • Conductor cross-section, direct plug-in - Rigid in mm² - Flexible end sleeve with/without plastic sleeve in mm² General data • Stripped length in mm • Molded plastic • Flammability Class acc. to UL 94 26-12 / -- 0.14 ... 4 0.14 ... 2.5 0.34 ... 4 0.34 ... 2.5 10 PA V0 8WH6 000-0AG00 8WH6 000-0AG01 8WH6 003-0AG00 8WH6 003-0AG01 8WH6 004-0AG00 8WH6 004-0AG01 Dimensions • Width/length/height in mm 6.2 / 56 / 36.5 6.2 / 66.5 / 36.5 6.2 / 77 / 36.5 Max. electrical data • Imax in A • Umax in V • Max. Ø in mm2 • AWG 38 800 0.2 ... 6 24-10 381) 800 0.2 ... 6 24-10 381) 800 0.2 ... 6 24-10 800 / 600 800 / 600 800 / 600 32/ 4 30 / -4 24-10 / 24-10 321) /4 30 / -4 24-10 / 24-10 321)/ 4 30 / -4 24-10 / 24-10 0.2 ... 6 0.2 ... 4 0.25 ... 4 0.2 ... 6 0.2 ... 4 0.25 ... 4 0.2 ... 6 0.2 ... 4 0.25 ... 4 0.5 ... 6 0.5 ... 4 0.2 ... 6 0.5 ... 4 0.5 ... 6 0.5 ... 4 12 PA V0 12 PA V0 12 PA V0 Rating according to IEC 60947-7-1 • Rated voltage in V (IEC / UL/CSA) • Rated current in A / cross-section in mm² - IEC - UL/CSA • Nominal cross-section in mm² • AWG cross-section range (IEC / UL/CSA) Connection capacities • 1 conductor - Rigid in mm² - Flexible in mm² - Flexible end sleeve with/without plastic sleeve in mm² • Conductor cross-section, direct plug-in - Rigid in mm² - Flexible end sleeve with/without plastic sleeve in mm² General data • Stripped length in mm • Molded plastic • Flammability Class acc. to UL 94 1) The total current through all connected conductors must not exceed the max. load current. 8WH6 000-0CG07 8WH6 003-0CG07 8WH6 004-0CG07 Dimensions • Width/length/height (NS 35/7.5) in mm 6.2 / 56 / 36.5 6.2 / 66.5 / 36.5 6.2 / 77 / 36.5 Max. electrical data • Max. Ø in mm2 • AWG 0.2 ... 6 24-10 0.2 ... 6 24-10 0.2 ... 6 24-10 Rating according to IEC 60947-7-1 • Nominal cross-section in mm² • AWG cross-section range (IEC / UL/CSA) 4 24-10 / 24-10 4 24-10 / 24-10 4 24-10 / 24-10 0.2 ... 6 0.25 ... 4 0.2 ... 6 0.2 ... 4 0.2 ... 6 0.2 ... 4 12 PA V0 12 PA V0 Connection capacities • 1 conductor - Rigid in mm² - Flexible end sleeve with/without plastic sleeve in mm² • Conductor cross-section, direct plug-in - Rigid in mm² - Flexible end sleeve with/without plastic sleeve in mm² General data • Stripped length in mm • Molded plastic •Flammability Class acc. to UL 94 0.5 ... 6 0.5 ... 4 12 PA V0 2/5 2 8WH6 iPo Plug-In Terminals 2 8WH6 through-type terminals ■ Selection and ordering data Version Order No. MOQ* Terminal size 2.5 mm² 8WH6 000-0AF00 Through-type terminals, terminal size 2.5 mm² • CUUS • Terminal width 5.2 mm • Imax = 30 A • Umax = 800 V • AWG 26-12 • Connection capacity, one conductor - Rigid 0.14 ... 4 mm² - Flexible 0.14 ... 2.5 mm² Versions • Two clamping points - Gray - Blue 8WH6 000-0AF00 8WH6 000-0AF01 50 units 50 units • Three clamping points - Gray - Blue 8WH6 003-0AF00 8WH6 003-0AF01 50 units 50 units • Four clamping points - Gray - Blue 8WH6 004-0AF00 8WH6 004-0AF01 50 units 50 units 8WH6 000-0CF07 8WH6 003-0CF07 8WH6 004-0CF07 50 units 50 units 50 units • For two clamping points • For three clamping points • For four clamping points 8WH9 000-1GA00 8WH9 000-2GA00 8WH9 000-4GA00 50 units 50 units 50 units Cover segments, for terminal size 1.5 ... 2.5 mm² For covering multi-wire terminals when mounting two-wire terminals sideby-side 8WH9 000-0GA00 10 units 8WH9 070-0AA00 8WH9 070-0GA00 8WH9 070-0HA00 50 units 50 units 50 units PE through-type terminals, terminal size 2.5 mm² • CUUS • Terminal width 5.2 mm • AWG 26-12 • Connection capacity, one conductor - Rigid 0.14 ... 4 mm² - Flexible 0.14 ... 2.5 mm² • Green/yellow 8WH6 000-0CF07 Versions • Two clamping points • Three clamping points • Four clamping points Accessories Covers, for terminal sizes 1.5 ... 2.5 mm² Width 2.2 mm Versions 8WH9 000-0GA00 Compartment partitions, for terminal size 1.5 ... 4 mm² • For visual and electrical separation of terminal groups • 2 mm thick • Gray Versions 8WH9 070-0AA00 • For two clamping points • For three clamping points • For four clamping points Note For general accessories for 8WH terminal blocks, see chapter 8 2/6 * You can order this quantity or a multiple thereof. 8WH6 iPo Plug-In Terminals 8WH6 through-type terminals Version Order No. MOQ* Terminal size 4 mm² 8WH6 000-0AG00 Through-type terminals, terminal size 4 mm² • CUUS • Terminal width 6.2 mm • Imax = 38 A • Umax = 800 V • AWG 24-10 • Connection capacity, one conductor - Rigid 0.2 ... 6 mm² - Flexible 0.2 ... 4 mm² Versions 8WH6 003-0AG00 • Two clamping points - Gray - Blue 8WH6 000-0AG00 8WH6 000-0AG01 50 units 50 units • Three clamping points - Gray - Blue 8WH6 003-0AG00 8WH6 003-0AG01 50 units 50 units • Four clamping points - Gray - Blue 8WH6 004-0AG00 8WH6 004-0AG01 50 units 50 units 8WH6 000-0CG07 8WH6 003-0CG07 8WH6 004-0CG07 50 units 50 units 50 units 8WH9 003-1GA00 8WH9 003-2SA00 8WH9 003-4SA00 50 units 50 units 50 units 8WH9 070-0AA00 8WH9 070-0GA00 8WH9 070-0HA00 50 units 50 units 50 units 8WH6 003-0AG01 8WH6 004-0AG00 8WH6 004-0AG01 8WH6 000-0CG07 PE through-type terminal, terminal size 4 mm² • CUUS • Terminal width 6.2 mm • AWG 24-10 • Connection capacity, one conductor - Rigid 0.2 ... 6 mm² - Flexible 0.2 ... 4 mm² • Green/yellow Versions • Two clamping points • Three clamping points • Four clamping points 8WH6 003-0CG07 8WH6 004-0CG07 Accessories Covers, for terminal size 4 mm² Width 2.2 mm Versions 8WH9 003-1GA00 • For two clamping points • For three clamping points • For four clamping points Compartment partitions, for terminal size 1.5 ... 4 mm² • For visual and electrical separation of terminal groups • 2 mm thick • Gray Versions 8WH9 070-0AA00 • For two clamping points • For three clamping points • For four clamping points Note: For general accessories for 8WH terminal blocks, see chapter 8. * You can order this quantity or a multiple thereof. 2/7 2 8WH6 iPo Plug-In Terminals 2 8WH6 fuse terminals ■ Overview The fuse terminals are characterized by their compact design and have the same contour as through-type terminals and function terminals. Double bridging is possible. Versions with and without LED display to signal a fuse. Fuse terminals can be inscribed at their clamping points with flat labels. ■ Technical specifications 8WH6 000-1GG08 Dimensions • Width/length/height (NS 35/7.5) in mm 6.2 /56 / 62.5 Max. electrical data • Imax in A • Umax in V • Max. Ø in mm2 • AWG 6.31) 500 0.2 ... 6 24-10 Rating according to IEC 60947-7-1 • Rated voltage in V (IEC / UL/CSA) • Rated current in A / cross-section in mm² - IEC - UL/CSA • Nominal cross-section in mm² • AWG cross-section range (IEC / UL/CSA) Connection capacities • 1 conductor - Rigid in mm² - Flexible in mm² - Flexible end sleeve with/without plastic sleeve in mm² • Conductor cross-section, direct plug-in - Rigid in mm² - Flexible end sleeve with/without plastic sleeve in mm² General data • Stripped length in mm • Molded plastic • Flammability class acc. to UL 94 1) 8WH6 000-1KG38 8WH6 000-1MG88 500 / 300 6.3/ 1 6.3 / -4 24-10 / 24-10 0.2 ... 6 0.2 ... 4 0.25 ... 4 0.5 ... 6 0.5 ... 4 12 PA V0 The total current through all connected conductors must not exceed the max. load current. ■ Selection and ordering data Version Order No. MOQ* Terminal size 4 mm² Fuse terminals, terminal size 4 mm², for 5 x 20 mm G fuse links • CUUS, s • Terminal width 6.2 mm • Imax = 6.3 A • Umax = 500 V • AWG 24-10 • Connection capacity, one conductor - Rigid 0.2 ... 4 mm² - Flexible 0.2 ... 4 mm² • Black 8WH6 000-1GG08 Versions • Without LED • With LED 10 ... 30 V AC/DC • With LED 110 ... 250 V AC/DC 8WH6 000-1GG08 8WH6 000-1KG38 8WH6 000-1MG88 50 units 50 units 50 units Covers, for terminal size 4 mm² • For two clamping points • Width 2.2 mm 8WH9 003-1GA00 50 units Accessories 8WA9 003-1GA00 Note: For general accessories for 8WH terminal blocks, see chapter 8. 2/8 * You can order this quantity or a multiple thereof. 8WH6 iPo Plug-In Terminals 8WH6 isolating blade terminals ■ Overview Through-type terminals with isolating blade capability are the most commonly used terminal types in measuring and control technology. Key features of the 8WH6 isolating blade terminals are the slim design of only 5.2 mm and their high current-carrying capacity. Convenient testing is made possible by the integral double function shaft located on one side of the isolating point and the integrated test contact located on the other. Standard connecting combs allow easy execution of all potential-distribution tasks. Three and four-wire terminals up to 2.5 mm² are available for the multi-conductor connection. A label can be snapped on to the middle of each terminal at the front. Further labels can also be mounted flat on the side of the terminals. ■ Technical specifications 8WH6 000-6AF00 8WH6 003-6AF00 8WH6 004-6AF00 Dimensions • Width/length/height (NS 35/7.5) in mm 5.2 / 60.5 / 36.5 5.2 / 74 / 36.5 5.2 / 84 / 36.5 Max. electrical data • Imax in A • Umax in V • Max. Ø in mm2 • AWG 20 400 0.14 ... 4 26-12 201) Rating according to IEC 60947-7-1 • Rated voltage in V (IEC) • Rated current in A / cross-section in mm² (IEC) • Nominal cross-section in mm² • AWG cross-section range (IEC) 400 20 / 2.5 2.5 26-12 Connection capacities • 1 conductor - Rigid in mm² - Flexible in mm² - Flexible end sleeve with/without plastic sleeve in mm² • Conductor cross-section, direct plug-in - Rigid in mm² - Flexible end sleeve with/without plastic sleeve in mm² General data • Stripped length in mm • Molded plastic • Flammability class acc. to UL 94 1) 201) / 2.5 0.14 ... 4 0.14 ... 2.5 0.14 ... 2.5 0.34 ... 4 0.34 ... 2.5 10 PA V0 The total current through all connected conductors must not exceed the max. load current. 8WH6 000-6AG00 Dimensions • Width/length/height (NS 35/7.5) in mm 6.2 / 54 / 36.5 Max. electrical data • Imax in A • Umax in V • Max. Ø in mm2 • AWG 20 400 0.2 ... 6 24-10 Rating according to IEC 60947-7-1 • Rated voltage in V (IEC / UL/CSA) • Rated current in A / cross-section in mm² - IEC - UL/CSA • Nominal cross-section in mm² • AWG cross-section range (IEC / UL/CSA) Connection capacities • 1 conductor - Rigid in mm² - Flexible in mm² - Flexible end sleeve with/without plastic sleeve in mm² • Conductor cross-section, direct plug-in - Rigid in mm² - Flexible end sleeve with/without plastic sleeve in mm² General data • Stripped length in mm • Molded plastic • Flammability class acc. to UL 94 400 / 300 20/ 2.5 20 / -4 24-10 / 24-10 0.2 ... 6 0.2 ... 4 0.25 ... 4 0.5 ... 6 0.5 ... 4 12 PA V0 2/9 2 8WH6 iPo Plug-In Terminals 2 8WH6 isolating blade terminals ■ Selection and ordering data Version Order No. MOQ* Terminal size 2.5 mm² 8WH6 000-6AF00 Isolating blade terminals, terminal size 2.5 mm² • Terminal width 5.2 mm • Imax = 20 A • Umax = 400 V • AWG 26-12 • Connection capacity, one conductor - Rigid 0.14 ... 4 mm² - Flexible 0.14 ... 2.5 mm² Versions • Two clamping points • Three clamping points • Four clamping points 8WH6 000-6AF00 8WH6 003-6AF00 8WH6 004-6AF00 50 units 50 units 50 units Isolating blade terminals, terminal size 4 mm² • With 2 clamping points • Terminal width 6.2 mm • Imax = 20 A • Umax = 400 V • AWG 24-10 • Connection capacity, one conductor - Rigid 0.2 ... 6 mm² - Flexible 0.2 ... 4 mm² • Connection capacity, two conductors - Rigid 0.5 ... 6 mm² 8WH6 000-6CG00 50 units • For two clamping points • For three clamping points • For four clamping points 8WH9 000-3SC00 8WH9 000-3SD00 8WH9 000-5GA00 50 units 50 units 50 units Covers, for terminal size 4 mm² • For two clamping points • Width 2.2 mm 8WH9 003-1GA00 50 units Compartment partitions, for terminal size 1.5 ... 4 mm² • For two clamping points • For visual and electrical separation of terminal groups • 2 mm thick • Gray 8WH9 070-0AA00 50 units Terminal size 4 mm² 8WH6 000-6CG00 Accessories Covers, for terminal size 2.5 mm² Width 2.2 mm 8WH9 000-3SC00 8WA9 003-1GA00 8WH9 070-0AA00 Note: For general accessories for 8WH terminal blocks, see chapter 8. 2/10 * You can order this quantity or a multiple thereof. 8WH6 iPo Plug-In Terminals 8WH6 isolating terminals ■ Overview 8WH6 isolating terminals in iPo connection technology are available for special wiring tasks. With the same contour as the isolating blade terminals, 8WH6 isolating terminals are fitted with a universal plug-in zone in the middle of the terminal. Numerous wiring tasks can be performed on a terminal width of 5.2 mm by integrating the isolated through-type connector, the isolating plug, the component connector or the fused plug. A label can be snapped on to the middle of each terminal at the front. Further labels can also be mounted flat on the side of the terminals. ■ Technical specifications 8WH6 000-6CF00 8WH6 003-6CF00 8WH6 004-6CF00 Dimensions • Width/length/height (NS 35/7.5) in mm 5.2 / 60.5 / 36.5 5.2 / 74 / 36.5 5.2 / 84 / 36.5 Max. electrical data • Imax in A • Umax in V • Max. Ø in mm2 • AWG 20 4002) 0.14 ... 4 26-12 201) Rating according to IEC 60947-7-1 • Rated voltage in V (IEC) • Rated current in A / cross-section in mm² (IEC) • Nominal cross-section in mm² (IEC) • AWG cross-section range (IEC) 4002) 20 / 2.5 2.5 26-12 Connection capacities • 1 conductor - Rigid in mm² - Flexible in mm² - Flexible end sleeve with/without plastic sleeve in mm² • Conductor cross-section, direct plug-in - Rigid in mm² - Flexible end sleeve with/without plastic sleeve in mm² General data • Stripped length in mm • Molded plastic • Flammability class acc. to UL 94 201) / 2.5 0.14 ... 4 0.14 ... 2.5 0.14 ... 2.5 0.34 ... 4 0.34 ... 2.5 10 PA V0 8WH6 000-6CG00 Dimensions • Width/length/height (NS 35/7.5) in mm 6.2 / 56 / 36.5 Max. electrical data • Imax in A • Umax in V • Max. Ø in mm2 • AWG 20 4002) 0.2 ... 6 24-10 Rating according to IEC 60947-7-1 • Rated voltage in V (IEC / UL/CSA) • Rated current in A / cross-section in mm² - IEC - UL/CSA • Nominal cross-section in mm² • AWG cross-section range (IEC / UL/CSA) Connection capacities • 1 conductor - Rigid in mm² - Flexible in mm² - Flexible end sleeve with/without plastic sleeve in mm² • Conductor cross-section, direct plug-in - Rigid in mm² - Flexible end sleeve with/without plastic sleeve in mm² General data • Stripped length in mm • Molded plastic • Flammability class acc. to UL 94 400 / 300 20/ 2.5 20 / -4 24-10 / 24-10 0.2 ... 6 0.25 ... 4 0.25 ... 4 0.5 ... 6 0.5 ... 4 12 PA V0 1) The total current through all connected conductors must not exceed the max. load current. 2) Current and voltage are determined by the fitted plug. 2/11 2 8WH6 iPo Plug-In Terminals 2 8WH6 isolating terminals ■ Selection and ordering data Version Order No. MOQ* Terminal size 2.5 mm² 8WH6 000-6CF00 Isolating terminals, terminal size 2.5 mm² • Terminal width 5.2 mm • Imax = 20 A • Umax = 400 V • AWG 26-12 • Connection capacity, one conductor - Rigid 0.14 ... 4 mm² - Flexible 0.14 ... 2.5 mm² Versions • Two clamping points • Three clamping points • Four clamping points 8WH6 000-6CF00 8WH6 003-6CF00 8WH6 004-6CF00 50 units 50 units 50 units Isolating terminals, terminal size 4 mm² • With two clamping points • Terminal width 6.2 mm • Imax = 20 A • Umax = 400 V • AWG 24-10 • Connection capacity, one conductor - Rigid 0.2 ... 6 mm² - Flexible 0.2 ... 4 mm² 8WH6 000-6AG00 50 units • For two clamping points • For three clamping points • For four clamping points 8WH9 000-3SC00 8WH9 000-3SD00 8WH9 000-5GA00 50 units 50 units 50 units Covers, for terminal size 4 mm² • For two clamping points • Width 2.2 mm 8WH9 003-1GA00 50 units Compartment partitions, for terminal size 1.5 ... 4 mm² • For two clamping points • For visual and electrical separation of terminal groups • 2 mm thick • Gray 8WH9 070-0AA00 50 units Compartment partitions, for terminal size 1.5 ... 4 mm² • For three clamping points • For visual and electrical separation of terminal groups • 2 mm thick • Gray 8WH9 070-0GA00 50 units Terminal size 4 mm² 8WH6 000-6AG00 Accessories Covers, for terminal size 2.5 mm² Width 2.2 mm 8WH9 000-3SC00 8WA9 003-1GA00 8WH9 070-0AA00 8WH9 070-0AA00 Note: For general accessories for 8WH terminal blocks, see chapter 8. 2/12 * You can order this quantity or a multiple thereof. 8WH6 iPo Plug-In Terminals 8WH6 two-tier terminals ■ Overview Two-tier terminals with equipotential bonding for the upper and lower tiers are also available. With the same contour as 8WH6 two-tier terminals, 8WH6 twotier PE terminals round off the product range. Perfect mechanical and electrical contact with the support rail is provided by simply snapping the terminals onto the rail. 8WH6 PE two-tier terminals comply with all the requirements of IEC 60947-7-2. These include in particular: • Low contact resistance • Stainless clamping points • Green-yellow enclosure • Additional inscription options. With the two voltage levels routed through two tiers, the 8WH6 two-tier terminals require 50% less space than equivalent singletier terminals. To implement a wide range of wiring tasks, connecting combs can be fitted to both tiers of the two-tier terminal series. Facilities for inscription are provided at each clamping point. A label can be mounted flat at each clamping point by simply snapping it on. ■ Technical specifications 8WH6 020-0AF00 8WH6 025-0AF00 8WH6 020-0CF07 8WH6 020-0AG00 8WH6 025-0AG00 8WH6 020-0CG07 8WH6 020-0AF01 8WH6 020-0AG01 Dimensions • Width/length/height (NS 35/7.5) in mm Max. electrical data • Imax in A • Umax in V • Max. Ø in mm2 • AWG Rating according to IEC 60947-7-1 • Rated voltage in V (IEC) • Rated current in A / cross-section in mm² - IEC - UL/CSA • Nominal cross-section in mm² (IEC) • AWG cross-section range (IEC) Connection capacities • 1 conductor - Rigid in mm² - Flexible in mm² - Flexible end sleeve with/without plastic sleeve in mm² • Conductor cross-section, direct plug-in - Rigid in mm² - Flexible end sleeve with/without plastic sleeve in mm² General data • Stripped length in mm • Molded plastic • Flammability class acc. to UL 94 1) 5.2 / 68 / 47.5 5.2 / 78 / 55 26 500 0.14 ... 4 26-12 261) 500 20 / 2.5 201) / 2.5 6.2 / 83.5 / 47.5 --- 32 500 0.2 ... 6 24-10 --- -- 500 / 600 -- -- / -- 2.5 26-12 30 / -4 24-10 / 24-10 0.14 ... 4 0.14 ... 2.5 0.14 ... 2.5 0.2 ... 6 0.2 ... 4 0.25 ... 4 0.34 ... 4 0.34 ... 2.5 0.5 ... 6 0.5 ... 4 10 PA V0 12 PA V0 -- / --- / -- The total current through all connected conductors must not exceed the max. load current. 2/13 2 8WH6 iPo Plug-In Terminals 2 8WH6 two-tier terminals ■ Selection and ordering data Version Order No. MOQ* Terminal size 2.5 mm² 8WH6 020-0AF00 Two-tier terminals, terminal size 2.5 mm² • Terminal width 5.2 mm • Imax = 26 A • Umax = 500 V • AWG 26-12 • Connection capacity, one conductor - Rigid 0.14 ... 4 mm² - Flexible 0.14 ... 2.5 mm² Versions • Without equipotential bonding - Gray - Blue • With equipotential bonding 8WH6 020-0AF00 8WH6 020-0AF01 8WH6 025-0AF00 50 units 50 units 50 units 8WH6 020-0CF07 50 units 8WH6 020-0AG00 8WH6 020-0AG01 8WH6 025-0AG00 50 units 50 units 50 units 8WH6 020-0CG07 50 units Covers, for terminal sizes 1.5 ... 2.5 mm² • Width 2.2 mm • Gray 8WH9 000-4SE00 50 units Covers, for terminal sizes 1.5 ... 4 mm² • For two clamping points • Width 2.2 mm 8WH9 003-1VA00 50 units Compartment partitions, for terminal size 1.5 ... 4 mm² • For visual and electrical separation of terminal groups • 2 mm thick • Gray 8WH9 070-0BA00 50 units PE two-tier terminals, terminal size 2.5 mm² • Terminal width 5.2 mm • AWG 26-12 • Connection capacity, one conductor - Rigid 0.14 ... 4 mm² - Flexible 0.14 ... 2.5 mm² • Green/yellow 8WH6 020-0CF07 Note Bridging the terminal is only possible in the top level (central). Terminal size 4 mm² 8WH6 025-0AG00 Two-tier terminals, terminal size 4 mm² • Terminal width 6.2 mm • Imax = 32 A • Umax = 500 V • AWG 24-10 • Connection capacity, one conductor - Rigid 0.2 ... 6 mm² - Flexible 0.2 ... 4 mm² Versions • Without equipotential bonding - Gray - Blue • With equipotential bonding 8WH6 020-0CF07 PE two-tier terminals, terminal size 4 mm² • Terminal width 6.2 mm • AWG 24-10 • Connection capacity, one conductor - Rigid 0.2 ... 6 mm² - Flexible 0.2 ... 4 mm² • Green/yellow Note Bridging the terminal is only possible in the top level (central). Accessories 8WH9 000-4SE00 8WH9 003-1VA00 8WH9 070-0BA00 Note: For general accessories for 8WH terminal blocks, see chapter 8. 2/14 * You can order this quantity or a multiple thereof.