LITTELFUSE P1400AD

CATV and HFC SIDACtor Device
CATV and HFC SIDACtor Device
1
3
This SIDACtor device is a 1000 A solid state protection device offered in a TO-220 package.
It protects equipment located in the severe surge environment of Community Antenna TV
(CATV) applications.
Used in Hybrid Fiber Coax (HFC) applications, this device replaces the gas tube
traditionally used for station protection, because a SIDACtor device has a much tighter
voltage tolerance.
Electrical Parameters
CO
pF
Part
Number *
VDRM
Volts
VS
Volts
VT
Volts
IDRM
µAmps
IS
mAmps
IT
Amps
IH
mAmps
Pins 1-3
P1400AD
120
160
3
5
800
2.2
50
200
P1800AD
170
220
3
5
800
2.2
50
150
* For surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• VDRM is measured at IDRM.
• VS is measured at 100 V/µs.
• Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request.
• Off-state capacitance (CO) is measured at 1 MHz with a 2 V bias and is a typical value.
Surge Ratings
Series
IPP
8x20 µs
Amps
IPP
10x1000 µs
Amps
ITSM
60 Hz
Amps
di/dt
Amps/µs
D
1000
250
120
500
http://www.littelfuse.com
+1 972-580-7777
2 - 58
© 2004 Littelfuse, Inc.
SIDACtor® Data Book and Design Guide
CATV and HFC SIDACtor Device
Thermal Considerations
Package
Symbol
Modified
TO-220
Value
Unit
Operating Junction Temperature Range
-40 to +150
°C
TS
Storage Temperature Range
-65 to +150
°C
60
°C/W
Thermal Resistance: Junction to Ambient
Data Sheets
RθJA
1
Parameter
TJ
3
IPP – Peak Pulse Current – %IPP
+I
IT
IS
IH
IDRM
-V
+V
VT
VDRM
VS
Peak
Value
100
tr = rise time to peak value
td = decay time to half value
Waveform = tr x td
50
Half Value
0
0
td
tr
t – Time (µs)
-I
V-I Characteristics
tr x td Pulse Wave-form
8
6
4
25 ˚C
Ratio of
2
IH (TC = 25 ˚C)
10
IH
Percent of VS Change – %
14
12
0
-4
2.0
1.8
1.6
1.4
25 ˚C
1.2
1.0
0.8
0.6
0.4
-40 -20 0
-6
20 40 60 80 100 120 140 160
Case Temperature (TC) – ˚C
-8
-40 -20 0 20 40 60 80 100 120 140 160
Junction Temperature (TJ) – ˚C
Normalized VS Change versus Junction Temperature
© 2004 Littelfuse, Inc.
SIDACtor® Data Book and Design Guide
Normalized DC Holding Current versus Case Temperature
2 - 59
http://www.littelfuse.com
+1 972-580-7777