LITTELFUSE P6002AD

High Surge Current SIDACtor Device
High Surge Current SIDACtor Device
1
(T)
2
(G)
3
(R)
This SIDACtor device is a 1000 A solid state protection device offered in a TO-220 package.
It protects equipment located in the severe surge environment of Community Antenna TV
(CATV) applications.
This device can replace the gas tubes traditionally used for station protection because
SIDACtor devices have much tighter voltage tolerances.
Electrical Parameters
CO
pF
Part
Number *
VDRM
Volts
VS
Volts
VT
Volts
IDRM
µAmps
IS
mAmps
IT
Amps
IH
mAmps
Pins 1-3
P6002AD
550
700
5.5
5
800
2.2
50
60
* For surge ratings, see table below.
Electrical Parameters
CO
pF
Part
Number *
VDRM
Volts
VS
Volts
VT
Volts
IDRM
µAmps
IS
mAmps
IT
Amps
IH
mAmps
Pins 1-3
P3100AD
280
360
5.5
5
800
2.2
120
115
* For surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• VDRM is measured at IDRM.
• VS is measured at 100 V/µs.
• Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request.
• Off-state capacitance (CO) is measured at 1 MHz with a 2 V bias and is a typical value.
Surge Ratings
Series
IPP
8x20 µs
Amps
IPP
10x1000 µs
Amps
ITSM
60 Hz
Amps
di/dt
Amps/µs
D
1000
250
120
500
http://www.littelfuse.com
+1 972-580-7777
2 - 60
© 2004 Littelfuse, Inc.
SIDACtor® Data Book and Design Guide
High Surge Current SIDACtor Device
Thermal Considerations
Symbol
Modified
TO-220
Value
Unit
Operating Junction Temperature Range
-40 to +150
°C
TS
Storage Temperature Range
-65 to +150
°C
60
°C/W
RθJA
PIN 1
Parameter
TJ
Thermal Resistance: Junction to Ambient
Data Sheets
Package
PIN 3
PIN 2
Note: P6002AD is shown. P3100AD has no center lead.
IPP – Peak Pulse Current – %IPP
+I
IT
IS
IH
IDRM
-V
+V
VT
VDRM
VS
Peak
Value
100
tr = rise time to peak value
td = decay time to half value
Waveform = tr x td
50
Half Value
0
0
td
tr
t – Time (µs)
-I
V-I Characteristics
tr x td Pulse Wave-form
8
6
4
25 ˚C
Ratio of
2
IH (TC = 25 ˚C)
10
IH
Percent of VS Change – %
14
12
0
-4
2.0
1.8
1.6
1.4
25 ˚C
1.2
1.0
0.8
0.6
0.4
-40 -20 0
-6
20 40 60 80 100 120 140 160
Case Temperature (TC) – ˚C
-8
-40 -20 0 20 40 60 80 100 120 140 160
Junction Temperature (TJ) – ˚C
Normalized VS Change versus Junction Temperature
© 2004 Littelfuse, Inc.
SIDACtor® Data Book and Design Guide
Normalized DC Holding Current versus Case Temperature
2 - 61
http://www.littelfuse.com
+1 972-580-7777