Host Link Cables (RS-232C Cables for Programmable Controller) XW2Z-@@@P-V/S-V/S-CV/T CSM_XW2Z-___P-V_S-V_S-CV_T_DS_E_2_1 Ideal Cables for between Programmable Controllers and Host Computers SYSMAC PLC • CQM1 • C Series • CV Series • CVM1 Host • Personal computer • Factory Intelligent Terminal • Programmable Terminal XW2Z Host Link Cable Ordering Information SYSMAC Host Link Cable (RS-232C Cable for Programmable Controllers) SYSMAC PLC Units Wiring patterns D-sub, 25-pin Plug C200HS-CPU31/33/21/23 CQM1-CPU21 CQM1-CPU41 CQM1-CPU42 CQM1-CPU43 CQM1-CPU44 CV500/1000/2000 CVM1 CV500-LK201 (Communications port 2) C200HE-CPU42 C200HG-CPU43/63 C200HX-CPU44/64 C200HW-COM02 C200HW-COM04 C200HW-COM05 C200HW-COM06 CPM1-CIF01 ··· ··· C20-LK201-V1 C500-LK203 C500-LK201-V1 C120-LK201-V1 C200H-LK201 CV500-LK201 (Port 1, full-duplex mode) PLC Connector Hood FG FG 1 SD 2 3 RD 4 RS 5 CS 6 DR SG 7 ER 20 Host Connector Hood FG 1 --2 RD 3 SD 4 ER 5 SG 6 DR 7 RS 8 CS 9 --- CJ-series CPU Units CS-series CPU Units Serial Communications Unit XW2Z-200P-V 5m XW2Z-500P-V Host Connector Hood FG 1 --2 RD 3 SD 4 ER 5 SG 6 DR 7 RS 8 CS 9 --- 2m XW2Z-200S-V Personal computer: IBM PC/AT or compatible 5m XW2Z-500S-V 2m XW2Z-200S-CV 5m XW2Z-500S-CV D-sub, 9-pin Socket Host Connector Hood FG 1 --2 RD 3 SD 4 ER 5 SG 6 DR 7 RS 8 CS 9 --- Shield Programmable Terminal (PT): NT20S Cable SYSMAC PLC Units CQM1-CPU21 CQM1-CPU41 CQM1-CPU42 CQM1-CPU43 CQM1-CPU44 (Units with RS-232C port) C200HS-CPU31/33/21/23 CV500/1000/2000-CPU01 CVM1-CPU01/11 CV500-LK201 (Communications port 2) C200HE-CPU42 C200HG-CPU43/63 C200HX-CPU44/64 C200HW-COM02 C200HW-COM04 C200HW-COM05 C200HW-COM06 CPM1-CIF01 2m Host D-sub, 9-pin Socket Shield D-sub, 9-pin Plug PLC Connector Hood FG FG 1 SD 2 3 RD 4 RS 5 CS 6 --DR 7 ER 8 SG 9 Model D-sub, 9-pin Socket Shield D-sub, 9-pin Plug PLC Connector Hood FG --1 SD 2 3 RD 4 RS 5 CS 6 ----7 --8 SG 9 Cable length L * Wiring patterns D-sub, 9-pin Plug PLC Connector Hood FG --1 SD 2 RD 3 RS 4 CS 5 SG 9 Cable length L * Model 2m XW2Z-200T Host D-sub, 9-pin Plug Shield Host Connector Hood FG 1 --2 SD 3 RD 4 RS 5 CS 9 SG Programmable Terminal (PT): NT20S NT600S/NT620S/ NT620C NT30/NT30C 5m XW2Z-500T *Cable length L L 1 XW2Z Ratings and Specifications Item Type XW2Z-@P/S/T Rated current 1A Rated voltage 125 VAC Contact resistance 15 mΩ max. (at 20 mV, 100 mA max.) *1 Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 500 VAC for 1 min (leakage current: 1 mA max.) *2 Degree of protection IP00 Electrical protection class Class 0 Ambient operating temperature −25 to 80°C *1. Contact resistance of the Connector. *2. Dielectric strength of the Connector. Materials and Finish Item Part name Materials and finish Housing Connectors XM3A-0921 XM3A-2521 XM2S-0911/2511 Cable Contacts Fiber-glass reinforced PBT resin (UL94V-0)/milky white Mating ends Terminals Brass/nickel base, 0.4-μm gold plating Brass/nickel base, 3-μm tin plating Shell Steel/nickel plated Housing ABS resin/nickel plated UL2464 Interface Cable AWG28 or the equivalent 2 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2012.9 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2012 All Right Reserved.