MS-2203: The Relation Between the Comparative Tracking Index and Working...

Technical Article
MS-2203
.
The Relation Between the
Comparative Tracking Index
and Working Voltage
IDEA IN BRIEF
Improving the Comparative Tracking Index allows smaller
packages to achieve high working voltages.
The maximum working voltage of an isolated system
depends on a number of parameters according to IEC 60950.
These include creepage distance, pollution degree, and
material group. Pollution degree, a measure of the surface
contamination, is set by the system and has a typical value of
2, but creepage distance and material group depend on the
materials used in isolating elements such as digital isolators
and optocouplers. Table 1, from IEC 60950, shows the
relationships among these parameters.
To achieve a 400 V rms working voltage in a system designed
for a pollution degree of 2, an isolator needs 4 mm of
creepage for a material group of III for basic insulation. This
doubles to 8 mm for reinforced insulation. For convenience,
other working voltages can be determined by linearly
interpolating between the creepage distances (as indicated in
Table 1).
Note that, for a given working voltage, creepage distance can
be reduced if the material group can be improved; this
allows designers to save space by using smaller packages
while still adhering to IEC 60950.
To measure the material group of an insulator, a 0.1%
ammonium chloride solution is applied to the material, and
a voltage is applied across the insulator, allowing current to
flow. The material is rated for the highest voltage for which
carbon tracks are not formed on the surface. This testing
method is specified in IEC 60112. Table 2 shows the material
group classification for a range of CTI voltage measurements.
Table 1. Creepage Distance Requirements in Millimeters (mm) for IEC 60950
Pollution Degree
1
Working Voltage
Vrms
I, II, III
250
320
400
0.56
0.75
1.0
250
320
400
1.12
1.5
2.0
2
Material Group
I
II
III
Basic Insulation
1.25
1.8
2.5
1.6
2.2
3.2
2.0
2.8
4.0
Reinforced Insulation
2.5
3.6
5.0
3.2
4.4
6.4
4.0
5.6
8.0
3
I
II
III
3.2
4.0
5.0
3.6
4.5
5.6
4.0
5.0
6.3
6.4
8.0
10.0
7.2
9.0
11.2
8.0
10.0
12.6
Table 2. CTI Measures for Material Groups
Material Group
Group I
Group II
Group IIIa
Group IIIb
CTI [Vrms]
>600
400 to 600
175 to 400
100 to 175
June 2011 | Page 1 of 2
www.analog.com
©2011 Analog Devices, Inc. All rights reserved.
MS-2203
Technical Article
Under IEC 60112 guidelines, IIIb is the default material
group. Analog Devices, Inc., (ADI) iCoupler® product
packaging material, however, has been tested and demonstrated to achieve a CTI of more than 600 V rms, meeting
the requirements for Material Group I. For simplicity and
guard banding, ADI specifies Material Group II for new
products. For example, the ADuM347x uses an SSOP
package with 5.1 mm of creepage and Material Group II,
which is rated for a maximum working voltage of 360 V rms
for reinforced insulation. If the ADuM347x were categorized
as Material Group III, it would be limited to only 250 V rms.
By measuring and specifying the CTI of iCoupler products,
ADI is able to offer isolators with smaller form factors without
compromising isolation capability.
One Technology Way • P.O. Box 9106 • Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700 • Fax: 781.461.3113 • www.analog.com
Trademarks and registered trademarks are the property of their
respective owners.
T09981-0-6/11(0)
www.analog.com
©2011 Analog Devices, Inc. All rights reserved.
June 2011 | Page 2 of 2