SITRANS FC MASS 6000 Catalog Specifications Sheet

© Siemens AG 2016
Flow Measurement
SITRANS F C
Transmitter MASS 6000 IP67 compact/remote
• 4-wire Pt1000 temperature measurement ensures optimum
accuracy on mass flow, density and fraction flow.
• Fraction flow computation based on a 3rd-order algorithm
matching all applications.
• USM II platform enables fitting of add-on bus modules without
loss of functionality.
- All modules can be fitted through true "plug & play"
- Module and transmitter are automatically configured through
the SENSORPROM.
• Installation of the transmitter to the sensor is simple "plug &
play" via the sensor pedestal.
■ Overview
3
■ Application
SITRANS F C mass flowmeters are suitable for all applications
within the entire process industry, where there is a demand for
accurate flow measurement. The meter is capable of measuring
both liquid and gas flow.
MASS 6000 is based on digital signal processing technology –
engineered for high performance, fast flow step response, fast
batching applications, high immunity against process noise,
easy to install, commission and maintain.
The MASS 6000 transmitter delivers true multiparameter measurements i.e. mass flow, volume flow, density, temperature and
fraction.
The MASS 6000 IP67 transmitter can be compact mounted on all
sensors of type MASS 2100 DI 3 to DI 15, and can be used in
remote version for all types of MASS 2100/MC2 and FC300 sensors.
■ Benefits
• Dedicated mass flow chip with the latest ASIC technology
• Fast batching and flow step response with an update rate of
true 30 Hz
• Superior noise immunity due to a DFT (Discrete
Fourier Transformation) algorithm.
• Front end resolution better than 0.35 ns improves zero point
stability and enhances dynamic turn-down ratio on flow and
density accuracy.
• Advanced diagnosis and service menu enhances troubleshooting and meter verification.
• Built-in batch controller with compensation and monitoring
comprising 2 built-in totalizers
• Multi-parameter outputs, individual configurable for mass
flow, volume flow, density, temperature or fraction flow such as
Brix or Plato
• Digital input for batch control, remote zero adjust or forced
output mode
• All outputs can be forced to preset value for simulation, verification or calibration purposes.
• User-configurable operation menu with password protection
- 3 lines, 20 characters display in 11 languages
- Self-explaining error handling/log in text format
- Keypad can be used for controlling batch as
start/stop/hold/reset
• SENSORPROM technology automatically configures transmitter at start-up providing:
- Factory pre-programming with calibration data, pipe size,
sensor type, output settings
- Any values or settings changed by users are stored
automatically
- Automatically re-programming any new transmitter without
loss of accuracy
- Transmitter replacement in less than 5 minutes.
- True "plug & play"
3/182
Siemens FI 01 · 2016
The main applications for the MASS 6000 IP67 transmitter can
be found in:
• Food and beverage industries
• Pharmaceutical industries
• Automotive industry
• Oil and gas industry
• Power generation and utility industry
• Water and waste water industry
■ Design
The transmitter is designed in an IP67/NEMA 6 compact
polyamide enclosure which can be compact mounted on the
MASS 2100 sensor range DI 3 to DI 15 (1/8" to ½") and remote
mounted for the entire sensor series.
The MASS 6000 IP67 is available as standard with 1 current,
1 frequency/pulse and 1 relay output and can be fitted with addon modules for bus communication.
■ Function
The following functions are available:
• Mass flow rate, volume flow rate, density, temperature, fraction
flow
• 1 current output, 1 frequency/pulse output, 1 relay output,
1 digital input
• All outputs can be individually configured with mass, volume,
density etc.
• 2 built-in totalizers which can count positive, negative or net
• Low flow cut-off
• Density cut-off or empty pipe cut-off, adjustable
• Flow direction adjustable
• Error system consisting of error-log, error pending menu
• Display of operating time
• Uni/bidirectional flow measurement
• Limit switches with 1 or 2 limits, programmable for flow, density or temperature
• Noise filter setting for optimization of measurement performance under non-ideal application conditions
• Full batch controller
• Automatic zero adjustment menu, with zero point evaluation
feed back
• Full service menu for effective and straight forward application
and meter troubleshooting
© Siemens AG 2016
Flow Measurement
SITRANS F C
Transmitter MASS 6000 IP67 compact/remote
■ Technical specifications
Measurement of
Mass flow [kg/s (lb/min)],
volume flow [l/s (gpm)],
fraction [%],
°Brix, density [kg/m3, (lb/ft3)],
temperature [°C (°F)]
Current output
Enclosure
Material
Fibre glass reinforced polyamide
Rating
IP67/NEMA 6
Mechanical load
18 ... 1000 Hz random,
3.17 g RMS, in all directions, to
IEC 68-2-36
Current
0 ... 20 mA or 4 ... 20 mA
Load
< 800 
Supply voltage
Time constant
0 ... 99.9 s adjustable
24 V version
• Supply
Digital output
Frequency
0 ... 10 kHz, 50 % duty cycle
Time constant
0 ... 99.9 s adjustable
Active
24 V DC, 30 mA,
1 K  Rload  10 K,
short-circuit-protected
Power consumption
24 V DC
6W
Passive
3 ... 30 V DC, max. 110 mA,
250   Rload  10 K
24 V AC
10 VA
230 V AC
9 VA
Relay
Type
Change-over relay
Load
42 V/2 A peak
Functions
3
18 ... 30 V DC
20 ... 30 V AC
230 V version
• Supply
87 ... 253 V AC, 50 ... 60 Hz
Fuse
230 V version
T 400 mA, T 250 V (IEC 127) - not
replaceable by operator
Error level, error number, limit,
flow direction
24 V version
T 1 A, T 250 V (IEC 127) - not
replaceable by operator
Digital input
11 ... 30 V DC (Ri = 13.6 k)
EMC performance
Functionality
Start/hold/continue batch, zero
point adjust, reset totalizer 1/2,
force output, freeze output
Emission
EN 55011/CISPR-11 (Class A)
Immunity
EN/IEC 61236-1 (Industry)
NAMUR
Within the value limits according
to "General requirements“ with
error criteria A in accordance with
NE 21
Galvanic isolation
All inputs and outputs are galvanically isolated.
Isolation voltage:
• 500 V to supply
• 50 V between outputs
Cut-off
Low-flow
0 ... 9.9 % of maximum flow
Limit function
Mass flow, volume flow, fraction,
density, sensor temperature
Totalizer
Two eight-digit counters for forward, net or reverse flow
Display
• Background illumination with
alphanumerical text, 3  20
characters to indicate flow rate,
totalized values, settings and
faults. Time constant as current
output 1
• Reverse flow indicated by negative sign
Zero point adjustment
Via keypad or remote via digital
input
Environment
Environmental conditions acc. to
IEC/EN/UL 61010-1:
• Altitude up to 2000 m
• POLLUTION DEGREE 2
Maintenance
The flowmeter has a built-in error
log/pending menu which should
be inspected on a regular basis.
Cable glands
Two types of cable gland are
available in polyamide in the following dimensions:
M20 or ½“ NPT
Ambient temperature
Operation
-20 ... +50 °C (-4 ... +122 °F),
max. rel. humidity 80 % at 31 °C
(87.8 °F) decreasing to 50 % at
40 °C (104 °F) according to
IEC/EN/UL 61010-1
Storage
-40 ... +70 °C (-40 ... +158 °F)
(Humidity max. 95 %)
Communication
Add-on modules: HART,
PROFIBUS PA and DP,
Modbus RTU RS 485,
DeviceNet,
FOUNDATION Fieldbus H1
Siemens FI 01 · 2016
3/183
© Siemens AG 2016
Flow Measurement
SITRANS F C
Transmitter MASS 6000 IP67 compact/remote
Selection and Ordering data
Article No.
Add-on module
SITRANS F C MASS 6000 transmitter
Transmitter for wall mounting with wall mounting
bracket, fibre glass reinforced polyamide (1 current
output, 1 frq./pulse output, 1 relay output and connection board/PCB)
7 ME 4 1 1 0 -
Description
7AA7 0 - 77A7
HART1)
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Version
Remote IP67/NEMA 6 enclosure
3
2
Supply voltage
PROFIBUS PA Profile 31)
FDK:085U0236
PROFIBUS DP Profile 3
FDK:085U0237
Modbus RTU RS 485
FDK:085U0234
FOUNDATION Fieldbus H11)
A5E02054250
DeviceNet
FDK:085U0229
1)
1
2
115/230 V AC, 50 ... 60 Hz
24 V AC/DC
Article No.
 FDK:085U0226
Modules are rated Ex i when used with MASS 6000 Ex d.
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
Display/Keypad
1
with display
Operating instructions for SITRANS F add-on modules
Serial communication
No communication
A
HART
PROFIBUS PA Profile 3
PROFIBUS DP Profile 3
B
F
G
Modbus RTU RS 485
DeviceNet
FOUNDATION Fieldbus H1
E
H
J
Cable glands
1
2
M20
½“ NPT
Operating instructions for SITRANS F C MASS 6000 IP67
Description
Article No.
• English
A5E03071936
This device is shipped with a Quick Start guide and a CD containing
further SITRANS F C literature.
Description
Article No.
HART
• English
A5E03089708
PROFIBUS PA/DP
• English
• German
A5E00726137
A5E01026429
Modbus
• English
• German
A5E00753974
A5E03089262
FOUNDATION Fieldbus
• English
• German
A5E02318728
A5E02488856
DeviceNet
• English
A5E03089720
This device is shipped with a Quick Start guide and a CD containing
further SITRANS F C literature.
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
Spare parts for compact or remote IP67 version
Description
Accessories
Article No.
• M20
A5E00822490
• ½“ NPT
A5E00822501
MASS 6000 transmitter
IP67/NEMA 6
Fibre glass reinforced polyamide and without connection board
1 current output
1 frq./pulse output
1 relay output
Sun lid for MASS 6000
transmitter (Frame and lid)
A5E02328485
• 115/230 V AC, 50/60 Hz
7ME41101AA10-1AA0
• 24 V AC/DC
7ME41101AA20-1AA0
Article No.
Description
Cable glands, screwed
entries type in polyamide
(100 °C (212 °F)) black,
2 pcs.
Wall mounting unit for
IP67/NEMA 6 version with
wall bracket, without connection board but with
3/184
Siemens FI 01 · 2016
• 4 x M20 cable glands
FDK:085U1018
• 4 x ½“ NPT cable glands
A5E01164211
Connection board/PCB
Supply voltage:
115/230 V/24 V AC/DC
FDK:083H4260
© Siemens AG 2016
Flow Measurement
SITRANS F C
Transmitter MASS 6000 IP67 compact/remote
Description
Article No.
Terminal box kit with
■ Dimensional drawings
Compact
• M20 cable glands
A5E00832338
• ½“ NPT cable glands
A5E00832342
+
Change from remote to safe
area compact mounting of
MASS 6000 IP67/NEMA 6
with MASS 2100.
The kit consists of a terminal
box in polyamide incl. connection board, cable and
connector between PCB and
sensor pedestal, PCB, seal
and screws (4 pcs.) for
mounting on sensor.
Not approved for hazardous
locations
+
3
/
Terminal box, in polyamide,
inclusive lid
• M20 cable glands
FDK:085U1050
Dimensions in mm (inch)
• ½“ NPT cable glands
FDK:085U1052
MASS 2100
Not approved for hazardous
locations
Sensor size L3
H5
H6
[Di (inch)]
[mm (inch)] [mm (inch)] [mm (inch)]
Terminal box – lid in polyamide
FDK:085U1003
3 (1/8)
6 (¼)
15 (½)
Display and keypad
• Siemens Front
FDK:085U1039
Transmitter wall mounted
75 (2.95)
62 (2.44)
75 (2.95)
82 (3.23)
72 (2.83)
87 (3.43)
306 (12.04)
316 (12.44)
326 (12.83)
H5 + H6
[mm (inch)]
388 (15.28)
388 (15.28)
413 (16.26)
Ø12 (0.47)
Ø8 (0.31)
13 (0.51)
155 (6.10)
240 (9.45)
155 (6.10)
102 (4.02)
71 (2.80)
Ø8 (0.31)
30 (1.18)
13 (0.51)
71 (2.80)
50 (2.0)
170 (6.70)
Dimensions in mm (inch)
Siemens FI 01 · 2016
3/185
© Siemens AG 2016
Flow Measurement
SITRANS F C
Transmitter MASS 6000 IP67 compact/remote
■ Schematics
Electrical connection
Grounding
PE must be connected due to safety class 1 power supply.
Mechanical counters
3
When mounting a mechanical counter to terminals 57 and 58
(active output), a 1000 µF min. 35 V electrolytic capacitor must
be connected to the terminals 56 and 58. Capacitor + is connected to terminal 56 and capacitor - to terminal 58.
Output cables
If long cables are used in a noisy environment, it is recommended to use shielded cables.
Transmitter
N
1)
N
1
18 - 30 V DC
20 - 30 V DC
150 - 230 V AC
L
PE
Current
output
2
L
PE
PE
2)
31
0/4 - 20 mA
Load ≤ 800 Ω
32
Relay
44
45
Relay
Relay shown in de-energised condition
46
Passive output
max. 30 V/110 mA
42 V AC / 2 A
42 V AC / 2 A
$FWLYHRXWSXW
PD[P$
56
56
57
57
58
Digital input
PE
24 V
77
&RXQWHUSOF
58
11 - 30 V DC
78
MASS FC300
MASS MC2
MASS 6000 IP67
MASS 2100
Brown
81
Driver
82
1
Red
0
TEMP.SENSE IN
83
84
Yellow
0
89
TEMP.SENSE OUT
90
85
Pick-up 1
86
Pick-up 2
3/186
88
3
4
9
White
Black
Green
Blue
0
87
2
9
Orange
5
6
9
Violet
Gray
Siemens FI 01 · 2016
7
8
© Siemens AG 2016
Flow Measurement
SITRANS F C
Transmitter MASS 6000 for 19" insert/19" wall mounting
■ Overview
MASS 6000 is based on digital signal processing technology –
engineered for high performance, fast flow step response, fast
batching applications, high immunity against process noise,
easy to install, commission and maintain.
The MASS 6000 transmitter delivers true multi parameter measurements i.e.: Mass flow, volume flow, density, temperature and
fraction.
The MASS 6000 19" transmitter can be connected to all sensors
of types MASS 2100/MC2/FC300/FCS200 and are available in
different versions depending of number of output facilities, Ex
protection and grade of enclosure.
■ Benefits
• Dedicated mass flow chip with the latest ASIC technology
• Fast batching and flow step response with an update rate of
true 30 Hz
• Superior noise immunity due to a DFT (Discrete
Fourier Transformation) algorithm.
• Front end resolution better than 0.35 ns improves zero point
stability and enhances dynamic turn-down ratio on flow and
density accuracy.
• Advanced diagnosis and service menu enhances troubleshooting and meter verification.
• Built-in batch controller with compensation and monitoring
comprising 2 built-in totalizers
• Multi-parameter outputs, individual configurable for mass
flow, volume flow, density, temperature or fraction flow such as
Brix or Plato
• Many output capacities, up to 3 current, 2 frequency/pulse
and 2 relay outputs (excludes the possibility of an
add-on module)
• Digital input for batch-control, remote zero adjust or forced
output mode
• All outputs can be forced to preset value for simulation, verification or calibration purposes.
• User-configurable operation menu with password protection
- 3 lines, 20 characters display in 11 languages
- Self-explaining error handling/log in text format
- Keypad can be used for controlling batch as
start/stop/hold/reset
• SENSORPROM technology automatically configures transmitter at start-up providing:
- Factory pre-programming with calibration data, pipe size,
sensor type, output settings
- Any values or settings changed by users are stored automatically
- Automatically re-programming any new transmitter without
loss of accuracy
- Transmitter replacement in less than 5 minutes. True "plug &
play"
• 4-wire Pt1000 temperature measurement ensures optimum
accuracy on mass flow, density and fraction flow
• Fraction flow computation based on a 3rd-order algorithm
matching all applications
• USM II platform enables fitting of add-on bus modules without
loss of functionality.
- All modules can be fitted as true "plug & play"
- Module and transmitter automatically configured through the
SENSORPROM.
• Transmitter available with Ex approvals
• All electrical connections are easily accessible on the large
back plane PCB
■ Application
SITRANS F C Coriolis mass flowmeters are suitable for all applications within the entire process industry, where there is a demand for accurate flow measurement. The meter can measure
both liquids and gases.
The main applications for the MASS 6000 19” transmitter can be
found in:
• Chemical and pharmaceutical industries
• Food and beverage industries
• Automotive industry
• Oil and gas industry
• Power generation and utility industry
• Water and waste water industry
■ Design
The transmitter is designed as a 19" insert as base to be used in:
• 19" rack system
• Panel mounting IP65
• Back of panel mounting IP20
• Wall mounting IP66
The MASS 6000 19" is available as standard or as Ex-approved
transmitter which is to be mounted in the safe area.
Siemens FI 01 · 2016
3/187
3
© Siemens AG 2016
Flow Measurement
SITRANS F C
Transmitter MASS 6000 for 19" insert/19" wall mounting
■ Function
3
The following functions are available:
• Mass flow rate, volume flow rate, density, temperature, fraction
flow
• 2 output versions available as standard:
- 1 current output, 1 frequency/pulse output, 1 relay output,
1 digital input
- 3 current outputs, 2 frequency/pulse outputs, 2 relay outputs,
1 digital input
• All outputs can be individually configured with mass, volume,
density etc.
• 2 built-in totalizers which can count positive, negative or net
• Low flow cut-off
• Density cut-off or empty pipe cut-off, adjustable
• Flow direction
• Error system consisting of error-log, error pending menu
• Operating time
• Uni/bidirectional flow measurement
• Limit switches with 1 or 2 limits, programmable for flow, density or temperature
• Noise filter setting for optimization of measurement performance under non-ideal application conditions
• Full batch controller
• Automatic zero adjustment menu, with zero point evaluation
feed-back
• Full service menu for effective and straight forward application
and meter troubleshooting
■ Technical specifications
Measurement of
Mass flow [kg/s (lb/min)],
volume flow [l/s (gpm)],
fraction [%], °Brix,
density [kg/m3 (lb/ft3)],
temperature [°C (°F)]
Current output
Current
0 ... 20 mA or 4 ... 20 mA
Load
< 800 
Time constant
0 ... 99.9 s adjustable
Digital output
Frequency
0 ... 10 kHz, 50 % duty cycle
Time constant
0 ... 30 s adjustable
Active
24 V DC, 30 mA,
1 K  Rload  10 K, short-circuit-protected
3 ... 30 V DC, max. 110 mA,
250   Rload  10 K
Passive
Relay
Type
Change-over relay
Load
42 V/2 A peak
Functions
Error level, error number, limit,
direction
Digital input
11 ... 30 V DC
Functionality
Start/hold/continue batch, zero
point adjust, reset totalizer 1/2,
force output, freeze output
Galvanic isolation
All inputs and outputs are galvanically isolated.
Isolation voltage:
• 500 V to supply
• 50 V between outputs
Cut-off
Low-flow
3/188
0 ... 9.9 % of maximum flow
Siemens FI 01 · 2016
Limit function
Mass flow, volume flow, fraction,
density, sensor temperature
Totalizer
Two eight-digit counters for forward, net or reverse flow
Display
• Background illumination with alphanumerical text, 3  20 characters to indicate flow rate,
totalized values, settings and
faults
• Reverse flow indicated by negative sign
Zero point adjustment
Via keypad or remote via digital
input
Ambient temperature
Operation
-20 ... +50 °C (-4 ... +122 °F)
Storage
-40 ... +70 °C (-40 ... +158 °F)
(Humidity max. 95 %)
Communication
Add-on modules: HART,
PROFIBUS PA and DP,
Modbus RTU RS 485,
DeviceNet,
FOUNDATION Fieldbus H1
Enclosure 19”
Material
Aluminum/steel (DIN 41494)
Rating
IP20
Mechanical load
18 ... 1000 Hz random,
3.17 g RMS, in all directions, to
IEC 68-2-36
Supply voltage
24 V version
• Supply
24 V DC/AC, 50 ... 60 Hz
• Fluctuation
18 ... 30 V DC
20 ... 30 V AC
• Power consumption
6W
IN = 250 mA, IST = 2 A (30 ms)
230 V version
• Supply
87 ... 253 V AC, 50 ... 60 Hz
• Power consumption
9 VA
Fuse
230 V version
T 400 mA, T 250 V (IEC 127) - not
replaceable by operator
24 V version
T 1 A, T 250 V (IEC 127) - not
replaceable by operator
EMC performance
Emission
EN 55011/CISPR-11 (Class A)
Immunity
EN/IEC 61236-1 (Industry)
Ex approval
ATEX, EAC Ex: [Ex ia] IIC
Maintenance
The flowmeter has a built-in error
log/pending menu which should
be inspected on a regular basis.
Cable
• Max. 300 m
• C: max. 300 [pF/m];
LC/RC: max. 100 [H/]
• The total cable capacity must be
max. 200 nF.
Cable glands
The cable gland is available in
polyamide, in dimension: PG 13.5
© Siemens AG 2016
Flow Measurement
SITRANS F C
Transmitter MASS 6000 for 19" insert/19" wall mounting
Selection and Ordering data
Article No.
Accessories
SITRANS F C MASS 6000 transmitter
Transmitter for rack and wall mounting, incl. connection board
7 ME 4 1 1 0 -
Enclosure (without PCB, connection board)
2 7777 - 77A 0
Enclosure
19 inch insert IP20 (rack mount, purchase rack
separately)
19 inch insert in IP65 (wall mount, enclosure
included)
Description
Article No.
IP66/NEMA 4X, wall mounting enclosure for 19“ inserts
(without back plates). Use
with PCB A5E02559813 or
A5E02559814
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
C
• 21 TE
E
FDK:083F5037
3
Output configuration
A
C
1 current, 1 frequency, 1 relay
3 current, 2 frequency, 2 relay
• 42 TE
Supply voltage
FDK:083F5038
1
2
115/230 V AC, 50/60 Hz
24 V AC/DC
Ex Approvals
Standard (No Ex-approval)
With Ex approval
0
1
Enclosure
Display/Keypad
1
With display
Serial communication (Only possible to connect
to MASS 6000 version with 1 current output)
No communication
A
HART
PROFIBUS PA Profile 3
PROFIBUS DP Profile 3
B
F
G
Modbus RTU RS 485
DeviceNet
FOUNDATION Fieldbus H1
E
H
J
Attention (Ex applications)!
MC2 Ex version sensors must only be connected to MASS 6000 standard. The MASS 6000 connection board must be replaced by a connection board approved FDK:083H4294 or FDK:083H4295 (see
connection boards/PCB for MASS 6000 and MC2 sensors).
Operating instructions for SITRANS F C MASS 6000 19“
Description
Article No.
• English
A5E02944875
Description
Article No.
Panel mounting enclosure for
19“ insert (21 TE);
IP65/NEMA 2 enclosure in
ABS plastic for front panel
mounting
FDK:083F5030
Panel mounting enclosure for
19“ insert (42 TE);
IP65/NEMA 2 enclosure in
ABS plastic for front panel
mounting
FDK:083F5031
Back of panel mounting
enclosure for 19“ insert
(21 TE); IP20/NEMA 1 enclosure in aluminum
FDK:083F5032
Back of panel mounting
enclosure for 19“ insert
(42 TE); IP20/NEMA 1 enclosure in aluminum
FDK:083F5033
Front cover (7TE) for panel
mounting enclosure
FDK:083F4525
This device is shipped with a Quick Start guide and a CD containing
further SITRANS F iterature.
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
Cable glands
Description
Article No.
Cable gland, screwed
entry, type M20, in polyamide (100 °C (212 °F)) black,
2 pcs.
A5E00822490
Siemens FI 01 · 2016
3/189
© Siemens AG 2016
Flow Measurement
SITRANS F C
Transmitter MASS 6000 for 19" insert/19" wall mounting
3
Add-on module
Operating instructions for SITRANS F add-on modules
Note:
Only possible to connect to MASS 6000 versions with 1 current
output.
Description
Article No.
HART
• English
A5E03089708
PROFIBUS PA/DP
• English
• German
A5E00726137
A5E01026429
Modbus
• English
• German
A5E00753974
A5E03089262
FOUNDATION Fieldbus
• English
• German
A5E02318728
A5E02488856
DeviceNet
• English
A5E03089720
Description
Article No.
HART (Ex-i)
FDK:085U0226
PROFIBUS PA Profile 3 (Ex-i)
FDK:085U0236
PROFIBUS DP Profile 3
FDK:085U0237
Modbus RTU RS 485
FDK:085U0234
FOUNDATION Fieldbus H1
(Ex-i)
A5E02054250
DeviceNet
FDK:085U0229
This device is shipped with a Quick Start guide and a CD containing
further SITRANS F C literature.
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
Connection boards/PCB for MASS 6000 and MASS 2100 sensors
Description
Version
Article No.
Connection board MASS 6000 for 19“ IP20 rack mounting version
24 V
115/230 V
FDK:083H4272
Connection board MASS 6000 Ex [ia] IIC for 19“ IP20 rack mounting version
24 V
115/230 V
FDK:083H4273
Connection board MASS 6000 for 19“ wall mounting version,
for enclosure FDK:083F5037/FDK:083F5038
24 V
115/230 V
FDK:083H4274
Connection board MASS 6000 Ex [ia] IIC for 19“ wall mounting version,
for enclosure FDK:083F5037/FDK:083F5038
24 V
115/230 V
FDK:083H4275
Description
Version
Article No.
Connection board MASS 6000 for 19“ IP20 rack mounting version
24 V
115/230 V
FDK:083H4272
Connection board MASS 6000 for Ex application1) and 19“ IP20 rack mounting
version (connection board MASS 6000 to MC2 sensors Ex-approved)
24 V
115/230 V
FDK:083H4294
Connection board MASS 6000 for 19“ wall mounting version,
for enclosure FDK:083F5037/FDK:083F5038
24 V
115/230 V
FDK:083H4274
Connection board MASS 6000 for Ex application1) and 19“ wall mounting version 24 V
(connection board MASS 6000 to MC2 sensors Ex-approved),
115/230 V
for enclosure FDK:083F5037/FDK:083F5038
FDK:083H4295
Connection boards/PCB for MASS 6000 and MC2 sensors
1)
Attention (Ex application): MC2 Ex version sensors must only be connected to connection board FDK:083H4294 or FDK:083H4295.
Description
Article No.
Wall mounting enclosure in
ABS plastic IP65 with connection board/PCB for Ex
application connected to
MC2 Ex sensors
FDK:083H4296
3/190
Siemens FI 01 · 2016
© Siemens AG 2016
Flow Measurement
SITRANS F C
Transmitter MASS 6000 for 19" insert/19" wall mounting
Spare parts 19” versions
Enclosure (without PCB, connection board)
Description
Article No.
IP66/NEMA 4X, wall mounting enclosure for 19“ inserts
(without back plates). Use
with PCB A5E02559813 or
A5E02559814
• 21 TE
FDK:083F5037
3
• 42 TE
FDK:083F5038
Display unit for 19" versions
Order the Display and Keypad accessory from MASS
6000 IP67 compact/remote
(FDK:085U1039) and use
the display part only for
replacement
FDK:085U1039
Siemens FI 01 · 2016
3/191
© Siemens AG 2016
Flow Measurement
SITRANS F C
Transmitter MASS 6000 for 19" insert/19" wall mounting
■ Dimensional drawings
Transmitter 19” insert
14 (0.6)
193 (7.60)
106 (4.17)
175 (6.89)
91 (3.58)
168 (6.61)
128 (5.04)
122 (4.80)
3
2.8 (0.11)
Weight incl. back print 0.8 kg (1.8 lbs)
Dimensions in mm (inch)
Transmitter 19“ wall mounting
235 (9.25)
22 (0.86)
13 (0.51)
90 (3.54)
90 (3.54)
146 (5.75)
120 (4.72)
13 (0.51)
210 (8.27)
192 (7.56)
Dimensions in mm (inch)
3/192
Siemens FI 01 · 2016
Weight excl. transmitter: 2.3 kg (5.0 lbs)
© Siemens AG 2016
Flow Measurement
SITRANS F C
Transmitter MASS 6000 for 19" insert/19" wall mounting
Transmitter 19“ front of panel
144 (5.67)
197 (7.75)
3
198 (7.80)
50 (1.97)
140 (5.51)
184 (7.24)
Weight excl. transmitter: 1.2 kg (2.7 lbs)
185 (7.28)
Dimensions in mm (inch)
Siemens FI 01 · 2016
3/193
© Siemens AG 2016
Flow Measurement
SITRANS F C
Transmitter MASS 6000 for 19" insert/19" wall mounting
Transmitter, back of panel IP20/NEMA 1, 21 TE
163 (6.42)
144 (5.67)
3
218 (8.58)
57 (2.24)
132 (5.20)
117 (4.61)
Weight: 0.7 kg (1.6 lbs)
Dimensions in mm (inch)
Transmitter, back of panel IP20/NEMA 1, 42 TE
132 (5.20)
57 (2.24)
269 (10.59)
253 (9.96)
223 (8.87)
Weight: 0.9 kg (2.0 lbs)
Dimensions in mm (inch)
3/194
Siemens FI 01 · 2016
218 (8.58)
© Siemens AG 2016
Flow Measurement
SITRANS F C
Transmitter MASS 6000 for 19" insert/19" wall mounting
■ Schematics
Electrical connection
Grounding
PE must be connected due to safety class 1 power supply.
Mechanical counters
When mounting a mechanical counter to terminals 57 and 58
(active output), a 1000 µF min. 35 V electrolytic capacitor must
be connected to the terminals 56 and 58. Capacitor + is connected to terminal 56 and capacitor - to terminal 58.
3
Output cables
If long cables are used in noisy environment, it is recommended
to use shielded cables.
Transmitter
N
N
1)
1
18 - 30 V DC
20 - 30 V DC
150 - 230 V AC
L
PE
Current
output
Relay
2
L
PE
PE 2)
44
45
46
Passive output
max. 30 V/110 mA
56
Relay
Relay shown in de-energised condition
Active output
max. 30 mA
57
58
Current
output 2
56
Counter (plc)
24 V
58
11 - 30 V DC
78
91
0/4 - 20 mA
load ≤ 800 Ω
92
Current
output 3
95
96
97
Relay 2
0/4 - 20 mA
load ≤ 800 Ω
93
94
Passive output 2
max. 30 V/110 mA
Extended version
42 V AC / 2 A
42 V AC / 2 A
57
77
Digital input
PE
0/4 - 20 mA
load ≤ 800 Ω
31
32
$FWLYHRXWSXW
PD[P$
&RXQWHUSOF
95
24 V
96
97
98
99
100
Relay shown in de-energised condition
(relay 2 only available in 19” version)
Relay
42 V AC / 2 A
42 V AC / 2 A
MASS FC300
MASS MC2
MASS 6000 19”
Driver
TEMP.SENSE
IN
TEMP.SENSE
OUT
Pick-up 1
Pick-up 2
81
82
0
83
84
0
89
90
85
86
0
87
88
Brown
Red
Orange
Yellow
MASS 2100
1
2
9
3
4
9
White
Black
Green
Blue
Violet
Gray
5
6
9
7
8
Siemens FI 01 · 2016
3/195