MAG 5000/MAG6000 Catalog Specifications Sheet

© Siemens AG 2016
Flow Measurement
SITRANS F M
Transmitter MAG 5000/6000
■ Overview
■ Design
The transmitter is designed as either IP67 NEMA 4X/6 enclosure
for compact or wall mounting or 19" version as a 19” insert as a
base to be used in:
• 19" rack systems
• Panel mounting IP20/NEMA 1 (prepared for IP65/NEMA 2
display side)
• Back of panel mounting IP20/NEMA 1
• Wall mounting IP66/NEMA 4X
Several options on 19” versions are available such as:
• Transmitters mounted in safe area for Ex ATEX approved flow
sensors (incl. barriers)
• Transmitters with electrode cleaning unit on request
■ Function
Transmitter MAG 5000/6000 compact version (left) and 19“ insert version
(right)
The MAG 5000 and 6000 are transmitters engineered for high
performance, easy installation, commissioning and maintenance. The transmitters evaluate the signals from the
SITRANS F M sensors type MAG 1100, MAG 1100 F,
MAG 3100, MAG 3100 P and MAG 5100 W.
Transmitter types:
• MAG 5000: Max. measuring error  0.4 %  1 mm/s (incl. sensor)
• MAG 6000: Max. measuring error  0.2 %  1 mm/s (incl. sensor, see also sensor specifications) and with additional features such as: "plug & play" add-on bus modules; integrated
batch functions.
■ Benefits
• Superior signal resolution for optimum turn down ratio
• Digital signal processing with many possibilities
• Automatic reading of SENSORPROM data for easy commissioning
• User configurable operation menu with password protection.
• 3 lines, 20 characters display in 11 languages.
• Flow rate in various units
• Totalizer for forward, reverse and net flow as well as additional
information available
• Multiple functional outputs for process control, minimum configuration with analogue, pulse/frequency and relay output
(status, flow direction, limits)
• Comprehensive self-diagnostic for error indication and error
logging (see under SITRANS F M diagnostics)
• Batch control (MAG 6000 only)
• Custody transfer approval: PTB, OIML R 117, OIML R 49, MI001, PTB K 7.2 and OE12/C 040 for chilled water
• MAG 6000 with add-on bus modules for HART, FOUNDATION
Fieldbus H1, DeviceNet, Modbus RTU/RS 485, PROFIBUS PA
and DP
■ Application
The SITRANS F M flowmeters are suitable for measuring the flow
of almost all electrically conductive liquids, pastes and slurries.
The main applications can be found in:
• Water and waste water
• Chemical and pharmaceutical industries
• Food and beverage industries
• Power generation and utility
The MAG 5000/6000 are transmitters with a build-in alphanumeric display in several languages. The transmitters evaluate
the signals from the associated electromagnetic sensors and
also fulfil the task of a power supply unit which provides the
magnet coils with a constant current.
Further information on connection, mode of operation and installation can be found in the data sheets for the sensors.
Displays and controls
Operation of the transmitter can be carried out using:
• Control and display unit
• HART communicator
• PC/laptop and SIMATIC PDM software via HART communication
• PC/laptop and SIMATIC PDM software using PROFIBUS or
Modbus communication
Transmitter
min. 230 Ω
PC/
laptop
Operating and
display panel
HARTCommunicator
Coupling
module
RS 232
HART communication
PROFIBUS DP
Master
PROFIBUS PA
+
Coupler with
power supply
T
Bus
term.
.......
Transmitter with
PROFIBUS PA interface
PROFIBUS PA communication
Siemens FI 01 · 2016
3/33
3
© Siemens AG 2016
Flow Measurement
SITRANS F M
Transmitter MAG 5000/6000
■ Technical specifications
Mode of operation and design
Measuring principle
Empty pipe
Excitation frequency
Electrode input impedance
Electromagnetic with pulsed constant field
Detection of empty pipe (special
cable required in remote mounted
installation)
Depend on sensor size
> 1 x 1014 
Input
3
Digital input
• Activation time
• Current
11 ... 30 V DC, Ri = 4.4 K
50 ms
I11 V DC = 2.5 mA, I30 V DC = 7 mA
Output
Current output
• Signal range
• Load
• Time constant
Digital output
• Frequency
• Pulse (active)
• Pulse (passive)
• Time constant
Relay output
• Time constant
0 ... 20 mA or 4 ... 20 mA
< 800 
0.1 … 30 s, adjustable
0 ... 10 kHz, 50 % duty cycle
(uni/bidirectional)
24 V DC, 30 mA,
1 K  Ri  10 K, short-circuitprotected (power supplied from
flowmeter)
3 … 30 V DC, max. 110 mA,
200   Ri  10 K (powered
from connected equipment)
0.1 … 30 s, adjustable
• Load
Changeover relay, same as current output
42 V AC/2 A, 24 V DC/1 A
Low flow cut off
0 ... 9.9 % of maximum flow
Galvanic isolation
All inputs and outputs are galvanically isolated.
Display and keypad
Totalizer
Display
Time constant
Design
Enclosure material
• Compact version
• 19" insert
• Back of panel
• Panel mounting
• Wall mounting
0.4 % 1 mm/s
• MAG 6000
0.2 % 1 mm/s
See dimensional drawings
19“ insert
See dimensional drawings
Weight
Compact version
0.75 kg (2 lb)
19“ insert
See dimensional drawings
Power supply
• 115 ... 230 V AC +10 % -15 %,
50 ... 60 Hz
• 11 ... 30 V DC or 11 ... 24 V AC
Power consumption
• 230 V AC: 17 VA
• 24 V AC: 9 VA, IN = 380 mA,
IST = 8 A (30 ms)
• 12 V DC: 11 W, IN = 920 mA,
IST = 4 A (250 ms)
• 24 V DC: 8.4 VA, IN = 350 mA,
IST = 4 A (10 ms)
IST= 4 A (250 ms):
For solar panel please secure
stable current supply
Certificates and approvals
CE, C-UL general purpose,
C-tick; FM Class I, Div 2, CSA
Class I, Div 2, CMC/CPA
• Cold water: MI-001, PTB/OIML
R 49 (pattern approval DE/DK)
• Chilled water: PTB K 7.2;
OE12/C 040
• Other media than water (milk,
beer etc.): PTB and DANAK
OIML R 117 (pattern approval
DE/DK) (MAG 6000 CT)
Ambient temperature
• Display version:
-20 ... +60 °C (-4 ... +140 °F)
• Blind version:
-20 ... +60 °C (-4 ... +140 °F)
• MI-001 version
-25 ... +55 ºC (-13 ... +131 ºF)
Custody transfer approval
(MAG 5000/6000 CT)
• Custody transfer (CT) version
-20 ... +50 ºC (-4 ... +122 ºF)
• Storage
-40 ... +70 °C (-40 ... +158 °F)
Mechanical load (vibration)
Compact version
19“ insert
18 ... 1000 Hz, 3.17 g RMS,
sinusoidal in all directions to
IEC 68-2-36
1 ... 800 Hz, 1 g, sinusoidal in all
directions to IEC 68-2-36
Degree of protection
Compact version
19“ insert
EMC performance
3/34
Siemens FI 01 · 2016
IP67/NEMA 4X/6 to IEC 529 and
DIN 40050 (1 mH2O 30 min.)
IP20/NEMA 1 to IEC 529 and
DIN 40050
IEC/EN 61326-1 (all environments)
IEC/EN 61326-2-5
Fiber glass reinforced polyamide;
stainless steel AISI 316/1.4436
(IP65)
Standard 19“ insert of aluminum/steel (DIN 41494), width:
21 TE, height: 3 HE
IP20/NEMA 1; Aluminum
IP20/NEMA 1 (prepared for
IP65/NEMA 2 display side);
ABS plastic
IP66/NEMA 4X; ABS plastic
Compact version
Rated operation conditions
• Operation
Background illumination with
alphanumeric text, 3 x 20 characters to indicate flow rate, totalized
values, settings and faults;
Reverse flow indicated by negative sign
Time constant as current output
time constant
Dimensions
Max. measuring error (incl. sensor and zero point)1)
• MAG 5000
Two eight-digit counters for forward, net or reverse flow
Communication
Standard
• MAG 5000
• MAG 6000
Optional (MAG 6000 only)
• MAG 5000/6000 CT
1)
Without serial communication or
HART as option
Prepared for client-mounted addon modules
HART, Modbus RTU/RS 485,
FOUNDATION Fieldbus H1, DeviceNet, PROFIBUS PA,
PROFIBUS DP as add-on modules
No communication moduls
approved
For detailed accuracy specifications, see page 3/22
© Siemens AG 2016
Flow Measurement
SITRANS F M
Transmitter MAG 5000/6000
Safety barrier (e/ia)
Application
For use with MAG 5000/6000 19” and MAG 1100 Ex ATEX/MAG 3100 Ex ATEX
Ex approval
MAG 1100 Ex [EEx e ia] IIB ATEX
MAG 3100 Ex [EEx e ia] IIC ATEX
Cable parameter
Group
Capacity in F
Inductance in mH
Electrode
IIC
 4.1
 80
IIB
 45
 87
IIA
 45
 87
3
Ambient temperature
• During operation
-20 ... +50 °C (-4 ... +122 °F)
• During storage
-20 ... +70 °C (-4 ... +158 °F)
Enclosure
• Material
Standard 19” insert in aluminum/steel (DIN 41494)
• Width
21 TE (4.75”)
• Height
3 HE (5.25”)
• Rating
IP20 / NEMA 1 to EN 60529
• Mechanical load
1 g, 1 … 800 Hz sinusoidal in all directions to EN 60068-2-36
Siemens FI 01 · 2016
3/35
© Siemens AG 2016
Flow Measurement
SITRANS F M
Transmitter MAG 5000/6000
■ Selection and Ordering data
Transmitter MAG 6000
Transmitter MAG 5000
Article No.
Description
Transmitter MAG 5000 Blind
for compact and wall mounting; IP67/NEMA 4X/6, fibre
glass reinforced polyamide
• 11 ... 30 V DC/
11 ... 24 V AC
3
Description
Article No.
Transmitter MAG 6000 Blind
for compact and wall mounting; IP67/NEMA 4X/6, fibre
glass reinforced polyamide
 7ME69101AA30-0AA0
• 11 ... 30 V DC/
11 ... 24 V AC
 7ME69201AA30-0AA0
• 115 ... 230 V AC, 50/60 Hz  7ME69101AA10-0AA0
• 115 ... 230 V AC, 50/60 Hz  7ME69201AA10-0AA0
Transmitter MAG 5000 Display for compact and wall
mounting;
IP67/NEMA 4X/6, fibre glass
reinforced polyamide
Transmitter MAG 6000
for compact and wall mounting; IP67/NEMA 4X/6, fibre
glass reinforced polyamide
• 11 ... 30 V DC/
11 ... 24 V AC
 7ME69101AA30-1AA0
• 115 ... 230 V AC, 50/60 Hz  7ME69101AA10-1AA0
• 115 ... 230 V AC,
50/60 Hz, with HART
 7ME69101AA10-1BA0
Transmitter MAG 5000 CT
for compact and wall mounting, approved for custody
transfer (only with approval
marks, no verification – only
a complete flowmeter can
be verified, i.e. sensor
together with the transmitter);
IP67/NEMA 4X/6, fibre glass
reinforced polyamide
• 11 ... 30 V DC/
11 ... 24 V AC
7ME69101AA30-1AB0
• 115 ... 230 V AC, 50/60 Hz
7ME69101AA10-1AB0
Transmitter MAG 5000 for
19” rack and wall mounting
• 11 ... 30 V DC/
11 ... 24 V AC
 7ME69102CA30-1AA0
• 115 ... 230 V AC, 50/60 Hz  7ME69102CA10-1AA0
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
• 11 ... 30 V DC/
11 ... 24 V AC
 7ME69201AA30-1AA0
• 115 ... 230 V AC, 50/60 Hz  7ME69201AA10-1AA0
Transmitter MAG 6000 for
compact and wall mounting;
IP65/NEMA 4, stainless
steel AISI 316/1.4436 (only
for sensor with SS terminal
box) (for remote installation
order SS terminal box separately)
• 11 ... 30 V DC/
11 ... 24 V AC
7ME69201QA30-1AA0
• 115 ... 230 V AC, 50/60 Hz
7ME69201QA10-1AA0
Transmitter MAG 6000 CT
for compact and wall mounting, approved for custody
transfer, without verification
(no approval marks - only a
complete flowmeter can be
verified, i.e. sensor together
with the transmitter);
IP67/NEMA 4X/6, fibre glass
reinforced polyamide
• 11 ... 30 V DC/
11 ... 24 V AC
7ME69201AA30-1AD0
• 115 ... 230 V AC, 50/60 Hz
7ME69201AA10-1AD0
Spare part transmitter for CT
systems produced before
04/2016
• 11 ... 30 V DC/
11 ... 24 V AC
7ME69201AA30-1AB0
• 115 ... 230 V AC, 50/60 Hz
7ME69201AA10-1AB0
Transmitter MAG 6000 SV
for compact and wall mounting; special excitation 44 Hz
settings for Batch application DN 25/1“
IP67/NEMA 4X/6, fibre glass
reinforced polyamide
11 ... 30 V DC/
11 ... 24 V AC
7ME69201AB30-1AA0
115 ... 230 V AC, 50/60 Hz
7ME69201AB10-1AA0
Transmitter MAG 6000 for
19“ rack and wall mounting
• 11 ... 30 V DC/
11 ... 24 V AC
 7ME69202CA30-1AA0
• 115 ... 230 V AC, 50/60 Hz  7ME69202CA10-1AA0
3/36
Siemens FI 01 · 2016
© Siemens AG 2016
Flow Measurement
SITRANS F M
Transmitter MAG 5000/6000
Description
Article No.
Description
Transmitter MAG 6000 SV
for 19“ rack and wall mounting; special excitation 44 Hz
settings for Batch application DN 25/1“
• 11 ... 30 V DC/
11 ... 24 V AC
• 115 ... 230 V AC, 50/60 Hz
MAG 6000 with
IP66/NEMA 4X enclosure;
115 ... 230 V AC, 50/60 Hz;
cable gland PG13.5
• English
7ME69202CB30-1AA0
• English
A5E00726137
7ME69202CB10-1AA0
• German
A5E01026429
7ME69202EA10-1AA0
• English
A5E00753974
• German
A5E03089262
Modbus
3
FOUNDATION Fieldbus
• English
A5E02318728
• German
A5E02488856
DeviceNet
• English
A5E03089720
This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature.
7ME69202MA11-1AA0
• 11 … 30 V DC,
11 … 24 V AC, 50/60 Hz
7ME69202EB30-1AA0
• 115 … 230 V AC, 50/60 Hz
7ME69202EB10-1AA0
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
Operating instructions for SITRANS F M MAG 5000/6000
Article No.
For SITRANS F M
MAG 5000/6000 IP67
• English
A5E02338368
• German
A5E02944982
For SITRANS F M
MAG 5000/6000 19"
• English
A5E03089708
PROFIBUS PA/DP
MAG 6000 SV, 19” insert, in
IP66/NEMA 4X , ABS plastic enclosure, excitation frequency 44 Hz for Batch
application DN 25/1“;
cable gland PG13.5
Description
Article No.
HART
MAG 6000 with safety barrier for Ex-approved sensors, complete mounted
with IP66/NEMA 4X wall
mounting enclosure, ATEX,
115 ... 230 V AC, 50/60 Hz;
cable gland PG13.5
• For ATEX 2G D sensors
Operating instructions for SITRANS F add-on modules
A5E02082880
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
Accessories for MAG 5000 and MAG 6000
Description
Article No.
Accessory kit for remote use
of sensor with two 5-pin terminal blocks
A5E34827189
Wall mounting unit for
MAG 5000/6000 with IP67/
NEMA 4X/6 enclosure, wall
bracket, terminal box in
polyamide1)
• 4 x M20 cable glands
 FDK:085U1018
• 4 x ½“ NPT cable glands
 FDK:085U1053
Sun lid for MAG 5000/6000
transmitter (Frame and lid)
A5E02328485
Cable for standard electrode
or coil, 3 x 1.5 mm² / 18 gage
with shield PVC;
Temperature range:
-30 ... +70 °C (-22 ... +158 °F)
This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature.
• 10 m (33 ft)
 FDK:083F0121
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
• 20 m (65 ft)
 FDK:083F0210
• 40 m (130 ft)
 FDK:083F0211
• 60 m (200 ft)
 FDK:083F0212
Communication modules for MAG 6000
• 100 m (330 ft)
FDK:083F0213
 FDK:085U0226
• 150 m (500 ft)
FDK:083F3052
Modbus RTU/RS 485
 FDK:085U0234
• 200 m (650 ft)
FDK:083F3053
PROFIBUS PA Profile 3
 FDK:085U0236
• 500 m (1650 ft)
FDK:083F3054
PROFIBUS DP Profile 3
 FDK:085U0237
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
DeviceNet
 FDK:085U0229
1)
Description
HART (not for MAG 6000 I)
FOUNDATION Fieldbus H1
Article No.
A5E02054250
For stainless steel wall mounting kit, order:
- M20: FDK:085U1018 and A5E00836867
- ½ NPT: FDK:085U1053 and A5E00836868
Siemens FI 01 · 2016
3/37
© Siemens AG 2016
Flow Measurement
SITRANS F M
Transmitter MAG 5000/6000
Article No.
Description
Electrode cable for empty
pipe or low conductivity1),
double shielded,
3 x 0.25 mm².
Temperature range :
-30 ... +70 °C (-22 ... +158 °F)
3
• 10 m (33 ft)
 FDK:083F3020
• 20 m (65 ft)
 FDK:083F3095
• 40 m (130 ft)
FDK:083F3094
• 60 m (200 ft)
FDK:083F3093
• 100 m (330 ft)
FDK:083F3092
• 150 m (500 ft)
FDK:083F3056
• 200 m (650 ft)
FDK:083F3057
• 500 m (1650 ft)
FDK:083F3058
Low-noise electrode coax
cable for low conductivity
and high vibration levels of
cables, 3 x 0.13 mm2
• 2 m (6.6 ft)
A5E02272692
• 5 m (16.5 ft)
A5E02272723
• 10 m (33 ft)
A5E02272730
Cable kit with standard coil
cable1), 3 x 1.5 mm²/18 gage
with shield PVC and electrode cable double shielded,
3 x 0.25 mm²
Temperature range:
-30 ... +70 °C (-22 ... +158 °F)
• 5 m (16.5 ft)
 A5E02296329
• 10 m (33 ft)
 A5E01181647
• 15 m (49 ft)
 A5E02296464
• 20 m (65 ft)
 A5E01181656
• 25 m (82 ft)
 A5E02296490
• 30 m (98 ft)
 A5E02296494
• 40 m (130 ft)
 A5E01181686
• 50 m (164 ft)
 A5E02296498
• 60 m (200 ft)
A5E01181689
• 100 m (330 ft)
A5E01181691
• 150 m (500 ft)
A5E01181699
• 200 m (650 ft)
A5E01181703
• 500 m (1650 ft)
A5E01181705
Potting kit for terminal box of  FDK:085U0220
flow sensors for
IP68/NEMA 6P
19“ safety barrier (21 TE)1)
[EEx e ia] IIC for MAG 1100
Ex sensors and MAG 3100
Ex sensors 12 ... 24 V,
115 ... 230 V, incl. back
plate (A5E02559810)
FDK:083F5034
Panel mounting enclosure
for 19“ insert (21 TE);
IP65/NEMA 2 enclosure in
ABS plastic for front panel
mounting
FDK:083F5030
Panel mounting enclosure
for 19“ insert (42 TE);
IP65/NEMA 2 enclosure in
ABS plastic for front panel
mounting
FDK:083F5031
3/38
Siemens FI 01 · 2016
Description
Article No.
Back of panel mounting
enclosure for 19“ insert
(21 TE); IP20/NEMA 1 enclosure in aluminum
FDK:083F5032
Back of panel mounting
enclosure for 19“ insert
(42 TE); IP20/NEMA 1 enclosure in aluminum
FDK:083F5033
IP66/NEMA 4X, wall mounting enclosure for 19“ inserts
(without back plates). Use
with PCB A5E02559813 or
A5E02559814. Cable
glands (FDK:083G0288) not
included
• 21 TE
FDK:083F5037
• 42 TE
FDK:083F5038
Front cover (7TE) for panel
mounting enclosure
FDK:083F4525
Sun shield for remote
MAG 5000/6000 transmitters
A5E01209496
Sun Shield for compact
MAG 5000/6000 transmitters on MAG 3100
(DN 15 ... 2000 (½" ... 78") or
MAG 5100 W
(DN 150 ... 1200 (6" ... 48")
A5E01209500
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
1)
Special cables cannot be used with 19" safety barrier
© Siemens AG 2016
Flow Measurement
SITRANS F M
Transmitter MAG 5000/6000
Spare parts
Description
Article No.
Connection board
(for polyamide terminalbox)
Description
Article No.
Cable glands (polyamide),
4 pcs.
• 12 ... 24 V
A5E02559817
• M20
 A5E00822490
• 115 ... 230 V
A5E02559816
• ½“ NPT
 A5E00822501
Connection board
(for stainless steel terminalbox)
• 12 ... 24 V
A5E02604280
• 115 ... 230 V
A5E02604272
A5E02559809
• Connection board for
transmitter ia and safety
barrier
A5E02559810
• Connection board for
transmitter ia/ib and safety
barrier (only for sensors
produced before October
2007)
A5E02559811
• Connection board for
transmitter and cleaning
unit
FDK:083F4123
SENSORPROM memory
unit
(Sensor code and serial
numbers must be specified
on order)
• 2 kB
(for MAG 5000/6000/
MAG 6000 I)
- 1 pc.
FDK:085U1005
- 10 pcs.
FDK:083F5052
• 250 B
(for MAG 2500/3000)
FDK:085U1008
Display unit
for MAG 5000/6000
• Black neutral front
• Siemens front
HW key
FDK:083G0228
Sealing screws for sensor/
transmitter, 2 pcs
FDK:085U0221
½“ NPT
M20
3
Terminal box, in polyamide,
inclusive lid, terminal
blocks, gasket and screws
19“ enclosure, 12 ... 24 V,
115 ... 230 V
• Connection board for standard 19“ transmitter
• PG 13.5, 2 pcs.
• M20
FDK:085U1050
• ½" NPT
FDK:085U1052
Terminal box lid, in polyamide
FDK:085U1003
Terminal box, in stainless
steel, inclusive lid, terminal
blocks, gasket and screws,
for MAG 6000 in stainless
steel and for all Ex sensors,
• M20
A5E00836867
• ½" NPT
A5E00836868
Terminal box (3A) for
MAG 1100 F in polyamide,
inclusive lid, terminal
blocks, gasket and screws
• M20
A5E00822478
• ½" NPT
A5E00822479
Spare part kit for remote use
of sensor with 20 pcs. 5-pin
terminal blocks
A5E34346873
Wall unit enclosure IP66,
12 ... 24 V, 115 ... 230 V
• PCB for standard
transmitter
A5E02559813
• PCB for transmitter ia/e
and safety barrier
A5E02559814
• PCB for transmitter ia/ib
and safety barrier
(7ME6130, 7ME6150 and
7ME6330)
A5E02559812
• PCB for transmitter and
cleaning unit
A5E02559815
SENSORPROM programmer with RS 232 interface
FDK:083H4246
FDK:085U1038
FDK:085U1039
On request
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
Siemens FI 01 · 2016
3/39
© Siemens AG 2016
Flow Measurement
SITRANS F M
Transmitter MAG 5000/6000
■ Dimensional drawings
Transmitter IP67/NEMA 4X/6 compact polyamide
71 (2.80)
6 (0.24)
3
71 (2.80)
178 (7.01)
Ø8 (0.31)
Ø12 (0.47)
Ø8 (0.31)
30 (1.18)
13 (0.51)
155 (6.10)
Transmitter compact mounted, dimensions in mm (inch)
240 (9.45)
155 (6.10)
102 (4.02)
131 (5.16)
13 (0.51)
155 (6.10)
50 (2.0)
170 (6.70)
Transmitter wall mounted, dimensions in mm (inch)
Transmitter, 19” IP20/NEMA 1 standard unit
14 (0.6)
106 (4.17)
175 (6.89)
91 (3.58)
168 (6.61)
122 (4.80)
128 (5.04)
193 (7.60)
2.8 (0.11)
Weight incl. back print 0.8 kg (1.8 lbs)
Dimensions in mm (inch)
3/40
Siemens FI 01 · 2016
© Siemens AG 2016
Flow Measurement
SITRANS F M
Transmitter MAG 5000/6000
Transmitter, wall mounting IP66/NEMA 4X, 21 TE
235 (9.25)
3
22 (0.86)
13 (0.51)
90 (3.54)
90 (3.54)
146 (5.75)
120 (4.72)
13 (0.51)
210 (8.27)
Weight excl. transmitter: 2.3 kg (5.0 lbs)
192 (7.56)
Dimensions in mm (inch)
13 (0.51)
Transmitter, wall mounting IP66/NEMA 4X, 42 TE
235 (9.25)
13 (0.51)
22 (0.87)
90 (3.54)
90 (3.54)
146 (5.75)
120 (4.72)
357 (14.05)
339 (13.35)
Weight excl. transmitter: 2.9 kg (7.0 lbs)
Dimensions in mm (inch)
Siemens FI 01 · 2016
3/41
© Siemens AG 2016
Flow Measurement
SITRANS F M
Transmitter MAG 5000/6000
Transmitter, panel front IP20/NEMA 1, 21 TE
144 (5.67)
197 (7.75)
3
198 (7.80)
50 (1.97)
140 (5.51)
184 (7.24)
Weight excl. transmitter: 1.2 kg (2.7 lbs)
185 (7.28)
Dimensions in mm (inch)
Transmitter, panel front IP20/NEMA 1, 42 TE
144 (5.67)
294 (1.57)
198 (7.80)
140 (5.51)
281 (1.06)
Weight excl. transmitter: 1.6 kg (3.5 lbs)
282 (1.10)
Dimensions in mm (inch)
3/42
Siemens FI 01 · 2016
50 (1.97)
© Siemens AG 2016
Flow Measurement
SITRANS F M
Transmitter MAG 5000/6000
Transmitter, back of panel IP20/NEMA 1, 21 TE
163 (6.42)
144 (5.67)
218 (8.58)
3
57 (2.24)
132 (5.20)
117 (4.61)
Weight: 0.7 kg (1.6 lbs)
Dimensions in mm (inch)
Transmitter, back of panel IP20/NEMA 1, 42 TE
218 (8.58)
132 (5.20)
57 (2.24)
269 (10.59)
253 (9.96)
223 (8.87)
Weight: 0.9 kg (2.0 lbs)
Dimensions in mm (inch)
Siemens FI 01 · 2016
3/43
© Siemens AG 2016
Flow Measurement
SITRANS F M
Transmitter MAG 5000/6000
■ Schematics
Electrical connection
Grounding
PE must be connected due to safety class 1 power supply.
Mechanical counters
3
When mounting a mechanical counter to terminals 57 and 58
(active output), a 1000 µF capacitor must be connected to the
terminals 56 and 58. Capacitor + is connected to terminal 56
and capacitor - to terminal 58.
Output cables
If the output cable length is long in noisy environment, we
recommend to use shielded cable.
Power supply
Transmitter
115 ... 230 V AC
11 ... 30 V DC/11 ... 24 V AC
L1
L
1
N
N
2
PE
Outputs
PE
Current output
(Powered from transmitter)
31
32
0/4 - 20 mA
Load ≤ 800 Ω
Passive output
(External powered)
56
57
58
Digital output
Vx 3 ... 30 V
max. 110 mA
R
Menu setup
PLC-Digital input
Active output
(Powered from transmitter)
24 V max. 30 mA
Counter or PLC-Digital input
56
57
58
R
Negative:
Positive:
R = Pull up/down resistor
1... 10 KΩ may be
required - depending on
Cables/Input resistance
Relay output
44
45
46
NO
Relay
24 V DC/1 A
42 V AC/2 A
NC
Common
Digital input
77
78
11 ... 30 V DC
Input
91 92 93 94 95 96 97
Sensor
Reserved for communication modules
Sensor connection
1)
81
82
0
83
84
Electrode cable
81
82
0
83
84
Coil cable
85
86
85
86
Shield
1) Note:
Special cable with individual wire shields (shown as dotted lines) are only required
when using empty pipe function or long cables.
3/44