SITRANS P200 Catalog Specifications Sheet

© Siemens AG 2015
Pressure Measurement
Transmitters for basic requirements
SITRANS P200 for gauge and absolute pressure
■ Overview
■ Design
Device structure without explosion protection
The pressure transmitter consists of a piezoresistive measuring
cell with a diaphragm installed in a stainless steel enclosure. It
can be used with a connector per EN 175301-803-A (IP65), a
round plug M12 (IP67), a cable (IP67) or a Quickon cable quick
screw connection (IP67) connected electrically. The output signal is between 4 and 20 mA or 0 and 10 V.
Device structure with explosion protection
The pressure transmitter consists of a piezoresistive measuring
cell with a diaphragm installed in a stainless steel enclosure. It
can be used with a connector per EN 175301-803-A (IP65) or a
round plug M12 (IP67) connected electrically. The output signal
is between 4 and 20 mA.
■ Function
The SITRANS P200 pressure transmitter measures the gauge
and absolute pressure of liquids, gases and vapors.
• Ceramic measuring cell
• Gauge and absolute measuring ranges 1 to 60 bar (15 to
1000 psi)
• For general applications
■ Benefits
•
•
•
•
•
•
High measuring accuracy
Rugged stainless steel enclosure
High overload withstand capability
For aggressive and non-aggressive media
For measuring the pressure of liquids, gases and vapors
Compact design
■ Application
The SITRANS P200 pressure transmitter for gauge and absolute
pressure is used in the following industrial areas:
• Mechanical engineering
• Shipbuilding
• Power engineering
• Chemical industry
• Water supply
The pressure transmitter measures the gauge and absolute
pressure of liquids and gases as well as the level of liquids.
Mode of operation
U
const.
U
p
I
I0, UB
SITRANS P200 pressure transmitters (7MF1565-...), functional diagram
The ceramic measuring cell has a thin-film resistance bridge to
which the operating pressure p is transmitted through a ceramic
diaphragm.
The voltage output from the measuring cell is converted by an
amplifier into an output current of 4 to 20 mA or an output voltage
of 0 to 10 V DC.
The output current and voltage are linearly proportional to the input pressure.
Siemens FI 01 · 2015 US Edition
1/5
1
© Siemens AG 2015
Pressure Measurement
Transmitters for basic requirements
1
SITRANS P200 for gauge and absolute pressure
■ Technical specifications
Application
Design
Gauge and absolute pressure
measurement
Liquids, gases and vapors
Mode of operation
Measuring principle
Piezo-resistive measuring cell
(ceramic diaphragm)
Measured variable
Gauge and absolute pressure
Weight
Approx. 0.090 kg (0.198 lb)
Process connections
See dimension drawings
Electrical connections
• Connector per
EN 175301-803-A Form A with
cable inlet M16x1.5 or ½-14 NPT
or Pg 11
• M12 connector
• 2 or 3-wire (0.5 mm2) cable
(  5.4 mm)
• Quickon cable quick screw connection
Inputs
Measuring range
• Gauge pressure
- Metric
- US measuring range
1 … 60 bar (15 … 870 psi)
15 … 1000 psi
• Absolute pressure
- Metric
- US measuring range
0.6 … 16 bar a (10 … 232 psia)
10 … 300 psia
Wetted parts materials
• Measuring cell
AI2O3 - 96 %
• Process connection
Stainless steel, mat. No. 1.4404
(SST 316 L)
• Gasket
• FPM (Standard)
• Neoprene
• Perbunan
• EPDM
Output
Current signal
4 ... 20 mA
• Load
(UB - 10 V)/0.02 A
• Auxiliary power UB
DC 7 ... 33 V (10 ... 30 V for Ex)
Voltage signal
0 ... 10 V DC
Non-wetted parts materials
• Load
 10 k
• Enclosure
• Auxiliary power UB
12 ... 33 V DC
Stainless steel, mat. No. 1.4404
(SST 316 L)
• Power consumption
< 7 mA at 10 k
• Rack
Plastic
Characteristic curve
Linear rising
• Cables
PVC
Certificates and approvals
Measuring accuracy
Error in measurement at limit setting
incl. hysteresis and reproducibility
• Typical: 0.25 % of full-scale
value
• Maximum: 0.5 % of full-scale
value
Classification according to pressure
equipment directive
(PED 97/23/EC)
For gases of fluid group 1 and liquids of fluid group 1; complies
with requirements of article 3,
paragraph 3 (sound engineering
practice)
Step response time T99
< 5 ms
Lloyd‘s Register of Shipping (LR)
12/20010
Germanischer Lloyd (GL)
GL19740 11 HH00
Long-term stability
• Lower range value and measuring
span
0.25 % of full-scale value/year
Influence of ambient temperature
• Lower range value and measuring
span
0.25 %/10 K of full-scale value
• Influence of power supply
0.005 %/V
American Bureau of Shipping (ABS) ABS_11_HG 789392_PDA
Bureau Veritas (BV)
BV 271007A0 BV
Det Norske Veritas (DNV)
A 12553
Drinking water approval (ACS)
ACS 11 ACC NY 055
GOST
GOST-R
Conditions of use
Underwriters Laboratories (UL)
Process temperature with gasket
made of:
• for USA and Canada
UL 20110217 - E34453
• worldwide
IEC UL DK 21845
• FPM (Standard)
-15 ... +125 °C (+5 ... +257 °F)
• Neoprene
-35 ... +100 °C (-31 ... +212 °F)
• Perbunan
-20 ... +100 °C (-4 ... +212 °F)
Intrinsic safety "i" (only with current
output)
• EPDM
-40 ... +145 °C (-40 ... +293 °F),
usable for drinking water
Ex II 1/2 G Ex ia IIC T4 Ga/Gb
Ex II 1/2 D Ex ia IIIC T125 °C
Da/Db
EC type-examination certificate
SEV 10 ATEX 0146
Ambient temperature
-25 ... +85 °C (-13 ... +185 °F)
Storage temperature
-50 ... +100 °C (-58 ... +212 °F)
Ui  30 V DC; Ii  100 mA;
Pi  0.75 W
Degree of protection (to EN 60529)
• IP 65 with connector per
EN 175301-803-A
• IP 67 with M12 connector
• IP 67 with cable
• IP 67 with cable quick screw
connection
Connection to certified intrinsicallysafe resistive circuits with maximum values:
Effective internal inductance and
capacity for versions with plugs per
EN 175301-803-A and M12
Li = 0 nH; Ci = 0 nF
Electromagnetic compatibility
• acc. IEC 61326-1/-2/-3
• acc. NAMUR NE21, only for
ATEX versions and with a max.
measuring deviation 1 %
1/6
Siemens FI 01 · 2015 US Edition
Explosion protection
© Siemens AG 2015
Pressure Measurement
Transmitters for basic requirements
SITRANS P200 for gauge and absolute pressure
■ Selection and ordering data
Article No.
SITRANS P 200 pressure transmitters for pressure and absolute pressure for general applications
Characteristic curve deviation typ. 0.25 %
Wetted parts materials: Ceramic and stainless steel + sealing material
Non-wetted parts materials: stainless steel
Order code
7M F 1 5 6 5 - 7 7 7 7 7 - 7 7 7 7 7 7 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Measuring range
Overload limit
Min.
Burst pressure
Max.
For gauge pressure
0 ... 1 bar
0 ... 1.6 bar
0 ... 2.5 bar
0 ... 4 bar
0 ... 6 bar
(0 ... 14.5 psi)
(0 ... 23.2 psi)
(0 ... 36.3 psi)
(0 ... 58.0 psi)
(0 ... 87.0 psi)
-1 bar
-1 bar
-1 bar
-1 bar
-1 bar
(-14.5 psi)
(-14.5 psi)
(-14.5 psi)
(-14.5 psi)
(-14.5 psi)
2.5 bar
4 bar
6.25 bar
10 bar
15 bar
(36.26 psi)
(58.02 psi)
(90.65 psi)
(145 psi)
(217 psi)
> 2.5 bar
> 4 bar
> 6.25 bar
> 10 bar
> 15 bar
(> 36.3 psi)
(> 58.0 psi)
(> 90.7 psi)
(> 145 psi)
(> 217 psi)
3 BA
3 BB
3 BD
3BE
3 BG
0 ... 10 bar
0 ... 16 bar
0 ... 25 bar
0 ... 40 bar
0 ... 60 bar
(0 ... 145 psi)
(0 ... 232 psi)
(0 ... 363 psi)
(0 ... 580 psi)
(0 ... 870 psi)
-1 bar
-1 bar
-1 bar
-1 bar
-1 bar
(-14.5 psi)
(-14.5 psi)
(-14.5 psi)
(-14.5 psi)
(-14.5 psi)
25 bar
40 bar
62.5 bar
100 bar
150 bar
(362 psi)
(580 psi)
(906 psi)
(1450 psi)
(2175 psi)
> 25 bar
> 40 bar
> 62.5 bar
> 100 bar
> 150 bar
(> 362 psi)
(> 580 psi)
(> 906 psi)
(> 1450 psi)
(> 2175 psi)
3 CA
3 CB
3 CD
3CE
3 CG
9 AA
Other version, add Order code and plain text: Measuring range: ... up to... bar (psi)
H1Y
For absolute pressure
0 ... 0.6 bar a
0 ... 1 bar a
0 ... 1.6 bar a
0 ... 2.5 bar a
(0 ... 8.7 psia)
(0 ... 14.5 psia)
(0 ... 23.2 psia)
(0 ... 36.3 psia)
0 bar a
0 bar a
0 bar a
0 bar a
(0 psia)
(0 psia)
(0 psia)
(0 psia)
3 bar a (43.51 psia)
2.5 bar a (36.26 psia)
4 bar a (58.02 psia)
6.25 bar a (90.65 psia)
> 2.5 bar a
> 2.5 bar a
> 4 bar a
> 6.25 bar a
(> 36.3 psia)
(> 36.3 psia)
(> 58.0 psia)
(> 90.7 psia)
5 AG
5 BA
5 BB
5 BD
0 ... 4 bar a
0 ... 6 bar a
0 ... 10 bar a
0 ... 16 bar a
(0 ... 58.0 psia)
(0 ... 87.0 psia)
(0 ... 145 psi)
(0 ... 232 psi)
0 bar a
0 bar a
0 bar a
0 bar a
(0 psia)
(0 psia)
(0 psia)
(0 psia)
10 bar a
15 bar a
25 bar a
40 bar a
> 10 bar a
> 15 bar a
> 25 bar a
> 40 bar a
(> 145 psia)
(> 217 psia)
(> 362 psia)
(> 580 psia)
5BE
5 BG
5 CA
5 CB
(145 psia)
(217 psia)
(362 psia)
(580 psia)
9 AA
Other version, add Order code and plain text: Measuring range: ... up to ... mbar a (psia)
H2Y
Measuring ranges for gauge pressure (only for US market)
(0 ... 15 psi)
(3 ... 15 psi)
(0 ... 20 psi)
(0 ... 30 psi)
(-14.5 psi)
(-14.5 psi)
(-14.5 psi)
(-14.5 psi)
(35 psi)
(35 psi)
(50 psi)
(80 psi)
(> 35 psi)
(> 35 psi)
(> 50 psi)
(> 80 psi)
4 BB
4 BC
4 BD
4BE
(0 ... 60 psi)
(0 ... 100 psi)
(0 ... 150 psi)
(0 ... 200 psi)
(-14.5 psi)
(-14.5 psi)
(-14.5 psi)
(-14.5 psi)
(140 psi)
(200 psi)
(350 psi)
(550 psi)
(> 140 psi)
(> 200 psi)
(> 350 psi)
(> 550 psi)
4BF
4 BG
4 CA
4 CB
(0 ... 300 psi)
(0 ... 500 psi)
(0 ... 750 psi)
(0 ... 1000 psi)
(-14.5 psi)
(-14.5 psi)
(-14.5 psi)
(-14.5 psi)
(800 psi)
(1400 psi)
(2000 psi)
(2000 psi)
(> 800 psi)
(> 1400 psi)
(> 2000 psi)
(> 2000 psi)
4 CD
4CE
4CF
4 CG
9 AA
Other version, add Order code and plain text: Measuring range: ... up to ... psi
H1Y
Measuring ranges for absolute pressure (only for US market)
(0 ... 10 psia)
(0 ... 15 psia)
(0 ... 20 psia)
(0 ... 30 psia)
(0 ... 60 psia)
(0 psia)
(0 psia)
(0 psia)
(0 psia)
(0 psia)
(35 psia)
(35 psia)
(50 psia)
(80 psia)
(140 psia)
(> 35 psia)
(> 35 psia)
(> 50 psia)
(> 80 psia)
(> 140 psia)
6 AG
6 BA
6 BB
6 BD
6BE
(0 ... 100 psia)
(0 ... 150 psia)
(0 ... 200 psia)
(0 ... 300 psia)
(0 psia)
(0 psia)
(0 psia)
(0 psia)
(200 psia)
(350 psia)
(550 psia)
(800 psia)
(> 200 psia)
(> 350 psia)
(> 550 psia)
(> 800 psia)
6 BG
6 CA
6 CB
6 CC
Other version, add Order code and plain text: Measuring range: ... up to ... psia
9 AA
Siemens FI 01 · 2015 US Edition
H2Y
1/7
1
© Siemens AG 2015
Pressure Measurement
Transmitters for basic requirements
1
SITRANS P200 for gauge and absolute pressure
■ Selection and ordering data
SITRANS P 200 pressure transmitters for pressure and absolute pressure for general applications
Accuracy typ. 0.25 %
Wetted parts materials: Ceramic and stainless steel + sealing material
Non-wetted parts materials: stainless steel
Article No.
Order code
7M F 1 5 6 5 - 7 7 7 7 7 - 7 7 7 7 7 7 7
Output signal
0
10
4 ... 20 mA; two-wire system; power supply 7 ... 33 V DC (10 ... 30 V DC for ATEX versions)
0 ... 10 V; three-wire system; power supply 12 ... 33 V DC
Explosion protection (only 4 ... 20 mA)
0
1
None
With explosion protection Ex ia IIC T4
Electrical connection
Connector per DIN EN 175301-803-A, stuffing box thread M16 (with coupling)
Round connector M12 per IEC 61076-2-101 (not for gauge pressure ranges  16 bar)
Connection via fixed mounted cable, 2 m (not for type of protection "Intrinsic safety i")
Quickon cable quick screw connection PG9 (not for type of protection "Intrinsic safety i")
Connector per DIN EN 175301-803-A, stuffing box thread 1/2"-14 NPT (with coupling)
Connector per DIN EN 175301-803-A, stuffing box thread PG11 (with coupling)
Fixed mounted cable, length 5 m
Special version
0
0
0
1
2
3
4
5
6
7
9
N1Y
Process connection
G½" male per EN 837-1 (½" BSP male) (standard for metric pressure ranges mbar, bar)
G½" male thread and G1/8" female thread
G¼“ male per EN 837-1 (¼“ BSP male)
7/16"-20 UNF male
A
B
C
D
¼"-18 NPT male (standard for pressure ranges inH2O and psi)
¼"-18 NPT female
½"-14 NPT male
½"-14 NPT female
7/16"-20 UNF female
M20x1.5 male
E
F
G
H
J
P
Special version
Z
P1Y
Sealing material between sensor and enclosure
A
B
C
D
Z
Viton (FPM, standard)
Neoprene (CR)
Perbunan (NBR)
EPDM
Special version
Version
Standard version
1
Further designs
Supplement the Article No. with "-Z" and add Order code.
Manufacturer’s test certificate M per IEC 60770-2 (calibration certificate) supplied
C11
Oxygen application, oil and grease-free cleaning
(only in conjunction with the sealing material Viton between sensor and enclosure and not with explosion
portection version)
E10
1/8
Siemens FI 01 · 2015 US Edition
Q1Y
© Siemens AG 2015
Pressure Measurement
Transmitters for basic requirements
SITRANS P200 for gauge and absolute pressure
■ Dimensional drawings
25.5 (1.0)
G1/2"
25
(1.0)
25
(1.0)
20
(0.8)
G1/8"
M16x1.5
or
1/2-14 NPT
20
(0.8)
M12x1/Fixcon
51 (2.0)
10.7 (0.42)
36 (1.42)
M20 x 1.5
G1/2"
1/2-14 NPT
20
(0.8)
16
(0.6)
G1/4"
7/16"-20 UNF
1/4-18 NPT
max. 20 Nm
7/16"-20 UNF
max. 20 Nm
23
(0.9)
SITRANS P200, electrical connections, dimensions in mm (inch)
25
(1.0)
Cable gland
with cable
16
(0.6)
24 (0.94)
30
(1.2)
30.2 (1.19)
max. 30 Nm
1/2"-14 NPT
1/2"-18 NPT
max. 20 Nm
SITRANS P200, process connections, dimensions in mm (inch)
Siemens FI 01 · 2015 US Edition
1/9
1
© Siemens AG 2015
Pressure Measurement
Transmitters for basic requirements
1
SITRANS P200 for gauge and absolute pressure
■ Schematics
1+
1
2
IO
Connection: 1 (+),
2 (-)
+
2-
UB
RL
IO Output current
RL Load
UB Power supply
Connection with current output and connector per EN 175301
1+
IO
UB
RL
3-
br
IO
gn
UB
RL
1
1+
IO
2-
4 3
1
UB
2
UO
+
UB
RL
4+
3-
Connection: 1 (+UB),
3 (-),
4 (+UO)
UO Output voltage
RL Load
UB Power supply
Connection with voltage output and connector M12x1
br
UO
gn
+
UB
RL
ws
Connection: br (+UB, brown),
gn (+UO, green),
ws (-, white)
UO Output voltage
UB Power supply
RL Load
Connection with voltage output and cable
1
Connection: 1 (+),
2 (-)
+
RL
1+
IO Output current
UB Power supply
RL Load
Connection with current output and cable
Connection: 1 (+UB),
2 (-),
3 (+UO)
UO Output voltage
RL Load
UB Power supply
Connection with voltage output and connector per EN 175301
Connection: br (brown),
gn (green)
+
UB
RL
2-
IO Output current
RL Load
UB Power supply
Connection with current output and connector M12x1
+
UO
3+
Connection: 1 (+),
3 (-)
+
3
1
1+
1
3
2
IO Output current
RL Load
UB Power supply
Connection with current output and Quickon cable quick screw connection
1+
3+
2
3
+
UO
RL
UB
2-
Connection: 1 (+UB),
3 (-),
2 (+UO)
UO Output voltage
RL Load
UB Power supply
Connection with voltage output and Quickon cable quick screw connection
Version with explosion protection: 4 ... 20 mA
The grounding connection is conductively bonded to the transmitter enclosure
1+
1
2
2-
+
IO
RL
UB
Connection: 1 (+),
2 (-)
IO Output current
RL Load
UB Power supply
Connection with current output and connector per EN 175301 (Ex)
1/10
Siemens FI 01 · 2015 US Edition
1+
4 3
1
34
IO
+
RL
UB
Connection: 1 (+),
3 (-),
4( )
IO Output current
RL Load
UB Power supply
Connection with current output and connector M12x1 (Ex)