© Siemens AG 2015 Pressure Measurement Transmitters for basic requirements SITRANS P200 for gauge and absolute pressure ■ Overview ■ Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure. It can be used with a connector per EN 175301-803-A (IP65), a round plug M12 (IP67), a cable (IP67) or a Quickon cable quick screw connection (IP67) connected electrically. The output signal is between 4 and 20 mA or 0 and 10 V. Device structure with explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure. It can be used with a connector per EN 175301-803-A (IP65) or a round plug M12 (IP67) connected electrically. The output signal is between 4 and 20 mA. ■ Function The SITRANS P200 pressure transmitter measures the gauge and absolute pressure of liquids, gases and vapors. • Ceramic measuring cell • Gauge and absolute measuring ranges 1 to 60 bar (15 to 1000 psi) • For general applications ■ Benefits • • • • • • High measuring accuracy Rugged stainless steel enclosure High overload withstand capability For aggressive and non-aggressive media For measuring the pressure of liquids, gases and vapors Compact design ■ Application The SITRANS P200 pressure transmitter for gauge and absolute pressure is used in the following industrial areas: • Mechanical engineering • Shipbuilding • Power engineering • Chemical industry • Water supply The pressure transmitter measures the gauge and absolute pressure of liquids and gases as well as the level of liquids. Mode of operation U const. U p I I0, UB SITRANS P200 pressure transmitters (7MF1565-...), functional diagram The ceramic measuring cell has a thin-film resistance bridge to which the operating pressure p is transmitted through a ceramic diaphragm. The voltage output from the measuring cell is converted by an amplifier into an output current of 4 to 20 mA or an output voltage of 0 to 10 V DC. The output current and voltage are linearly proportional to the input pressure. Siemens FI 01 · 2015 US Edition 1/5 1 © Siemens AG 2015 Pressure Measurement Transmitters for basic requirements 1 SITRANS P200 for gauge and absolute pressure ■ Technical specifications Application Design Gauge and absolute pressure measurement Liquids, gases and vapors Mode of operation Measuring principle Piezo-resistive measuring cell (ceramic diaphragm) Measured variable Gauge and absolute pressure Weight Approx. 0.090 kg (0.198 lb) Process connections See dimension drawings Electrical connections • Connector per EN 175301-803-A Form A with cable inlet M16x1.5 or ½-14 NPT or Pg 11 • M12 connector • 2 or 3-wire (0.5 mm2) cable ( 5.4 mm) • Quickon cable quick screw connection Inputs Measuring range • Gauge pressure - Metric - US measuring range 1 … 60 bar (15 … 870 psi) 15 … 1000 psi • Absolute pressure - Metric - US measuring range 0.6 … 16 bar a (10 … 232 psia) 10 … 300 psia Wetted parts materials • Measuring cell AI2O3 - 96 % • Process connection Stainless steel, mat. No. 1.4404 (SST 316 L) • Gasket • FPM (Standard) • Neoprene • Perbunan • EPDM Output Current signal 4 ... 20 mA • Load (UB - 10 V)/0.02 A • Auxiliary power UB DC 7 ... 33 V (10 ... 30 V for Ex) Voltage signal 0 ... 10 V DC Non-wetted parts materials • Load 10 k • Enclosure • Auxiliary power UB 12 ... 33 V DC Stainless steel, mat. No. 1.4404 (SST 316 L) • Power consumption < 7 mA at 10 k • Rack Plastic Characteristic curve Linear rising • Cables PVC Certificates and approvals Measuring accuracy Error in measurement at limit setting incl. hysteresis and reproducibility • Typical: 0.25 % of full-scale value • Maximum: 0.5 % of full-scale value Classification according to pressure equipment directive (PED 97/23/EC) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) Step response time T99 < 5 ms Lloyd‘s Register of Shipping (LR) 12/20010 Germanischer Lloyd (GL) GL19740 11 HH00 Long-term stability • Lower range value and measuring span 0.25 % of full-scale value/year Influence of ambient temperature • Lower range value and measuring span 0.25 %/10 K of full-scale value • Influence of power supply 0.005 %/V American Bureau of Shipping (ABS) ABS_11_HG 789392_PDA Bureau Veritas (BV) BV 271007A0 BV Det Norske Veritas (DNV) A 12553 Drinking water approval (ACS) ACS 11 ACC NY 055 GOST GOST-R Conditions of use Underwriters Laboratories (UL) Process temperature with gasket made of: • for USA and Canada UL 20110217 - E34453 • worldwide IEC UL DK 21845 • FPM (Standard) -15 ... +125 °C (+5 ... +257 °F) • Neoprene -35 ... +100 °C (-31 ... +212 °F) • Perbunan -20 ... +100 °C (-4 ... +212 °F) Intrinsic safety "i" (only with current output) • EPDM -40 ... +145 °C (-40 ... +293 °F), usable for drinking water Ex II 1/2 G Ex ia IIC T4 Ga/Gb Ex II 1/2 D Ex ia IIIC T125 °C Da/Db EC type-examination certificate SEV 10 ATEX 0146 Ambient temperature -25 ... +85 °C (-13 ... +185 °F) Storage temperature -50 ... +100 °C (-58 ... +212 °F) Ui 30 V DC; Ii 100 mA; Pi 0.75 W Degree of protection (to EN 60529) • IP 65 with connector per EN 175301-803-A • IP 67 with M12 connector • IP 67 with cable • IP 67 with cable quick screw connection Connection to certified intrinsicallysafe resistive circuits with maximum values: Effective internal inductance and capacity for versions with plugs per EN 175301-803-A and M12 Li = 0 nH; Ci = 0 nF Electromagnetic compatibility • acc. IEC 61326-1/-2/-3 • acc. NAMUR NE21, only for ATEX versions and with a max. measuring deviation 1 % 1/6 Siemens FI 01 · 2015 US Edition Explosion protection © Siemens AG 2015 Pressure Measurement Transmitters for basic requirements SITRANS P200 for gauge and absolute pressure ■ Selection and ordering data Article No. SITRANS P 200 pressure transmitters for pressure and absolute pressure for general applications Characteristic curve deviation typ. 0.25 % Wetted parts materials: Ceramic and stainless steel + sealing material Non-wetted parts materials: stainless steel Order code 7M F 1 5 6 5 - 7 7 7 7 7 - 7 7 7 7 7 7 7 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring range Overload limit Min. Burst pressure Max. For gauge pressure 0 ... 1 bar 0 ... 1.6 bar 0 ... 2.5 bar 0 ... 4 bar 0 ... 6 bar (0 ... 14.5 psi) (0 ... 23.2 psi) (0 ... 36.3 psi) (0 ... 58.0 psi) (0 ... 87.0 psi) -1 bar -1 bar -1 bar -1 bar -1 bar (-14.5 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) 2.5 bar 4 bar 6.25 bar 10 bar 15 bar (36.26 psi) (58.02 psi) (90.65 psi) (145 psi) (217 psi) > 2.5 bar > 4 bar > 6.25 bar > 10 bar > 15 bar (> 36.3 psi) (> 58.0 psi) (> 90.7 psi) (> 145 psi) (> 217 psi) 3 BA 3 BB 3 BD 3BE 3 BG 0 ... 10 bar 0 ... 16 bar 0 ... 25 bar 0 ... 40 bar 0 ... 60 bar (0 ... 145 psi) (0 ... 232 psi) (0 ... 363 psi) (0 ... 580 psi) (0 ... 870 psi) -1 bar -1 bar -1 bar -1 bar -1 bar (-14.5 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) 25 bar 40 bar 62.5 bar 100 bar 150 bar (362 psi) (580 psi) (906 psi) (1450 psi) (2175 psi) > 25 bar > 40 bar > 62.5 bar > 100 bar > 150 bar (> 362 psi) (> 580 psi) (> 906 psi) (> 1450 psi) (> 2175 psi) 3 CA 3 CB 3 CD 3CE 3 CG 9 AA Other version, add Order code and plain text: Measuring range: ... up to... bar (psi) H1Y For absolute pressure 0 ... 0.6 bar a 0 ... 1 bar a 0 ... 1.6 bar a 0 ... 2.5 bar a (0 ... 8.7 psia) (0 ... 14.5 psia) (0 ... 23.2 psia) (0 ... 36.3 psia) 0 bar a 0 bar a 0 bar a 0 bar a (0 psia) (0 psia) (0 psia) (0 psia) 3 bar a (43.51 psia) 2.5 bar a (36.26 psia) 4 bar a (58.02 psia) 6.25 bar a (90.65 psia) > 2.5 bar a > 2.5 bar a > 4 bar a > 6.25 bar a (> 36.3 psia) (> 36.3 psia) (> 58.0 psia) (> 90.7 psia) 5 AG 5 BA 5 BB 5 BD 0 ... 4 bar a 0 ... 6 bar a 0 ... 10 bar a 0 ... 16 bar a (0 ... 58.0 psia) (0 ... 87.0 psia) (0 ... 145 psi) (0 ... 232 psi) 0 bar a 0 bar a 0 bar a 0 bar a (0 psia) (0 psia) (0 psia) (0 psia) 10 bar a 15 bar a 25 bar a 40 bar a > 10 bar a > 15 bar a > 25 bar a > 40 bar a (> 145 psia) (> 217 psia) (> 362 psia) (> 580 psia) 5BE 5 BG 5 CA 5 CB (145 psia) (217 psia) (362 psia) (580 psia) 9 AA Other version, add Order code and plain text: Measuring range: ... up to ... mbar a (psia) H2Y Measuring ranges for gauge pressure (only for US market) (0 ... 15 psi) (3 ... 15 psi) (0 ... 20 psi) (0 ... 30 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) (35 psi) (35 psi) (50 psi) (80 psi) (> 35 psi) (> 35 psi) (> 50 psi) (> 80 psi) 4 BB 4 BC 4 BD 4BE (0 ... 60 psi) (0 ... 100 psi) (0 ... 150 psi) (0 ... 200 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) (140 psi) (200 psi) (350 psi) (550 psi) (> 140 psi) (> 200 psi) (> 350 psi) (> 550 psi) 4BF 4 BG 4 CA 4 CB (0 ... 300 psi) (0 ... 500 psi) (0 ... 750 psi) (0 ... 1000 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) (800 psi) (1400 psi) (2000 psi) (2000 psi) (> 800 psi) (> 1400 psi) (> 2000 psi) (> 2000 psi) 4 CD 4CE 4CF 4 CG 9 AA Other version, add Order code and plain text: Measuring range: ... up to ... psi H1Y Measuring ranges for absolute pressure (only for US market) (0 ... 10 psia) (0 ... 15 psia) (0 ... 20 psia) (0 ... 30 psia) (0 ... 60 psia) (0 psia) (0 psia) (0 psia) (0 psia) (0 psia) (35 psia) (35 psia) (50 psia) (80 psia) (140 psia) (> 35 psia) (> 35 psia) (> 50 psia) (> 80 psia) (> 140 psia) 6 AG 6 BA 6 BB 6 BD 6BE (0 ... 100 psia) (0 ... 150 psia) (0 ... 200 psia) (0 ... 300 psia) (0 psia) (0 psia) (0 psia) (0 psia) (200 psia) (350 psia) (550 psia) (800 psia) (> 200 psia) (> 350 psia) (> 550 psia) (> 800 psia) 6 BG 6 CA 6 CB 6 CC Other version, add Order code and plain text: Measuring range: ... up to ... psia 9 AA Siemens FI 01 · 2015 US Edition H2Y 1/7 1 © Siemens AG 2015 Pressure Measurement Transmitters for basic requirements 1 SITRANS P200 for gauge and absolute pressure ■ Selection and ordering data SITRANS P 200 pressure transmitters for pressure and absolute pressure for general applications Accuracy typ. 0.25 % Wetted parts materials: Ceramic and stainless steel + sealing material Non-wetted parts materials: stainless steel Article No. Order code 7M F 1 5 6 5 - 7 7 7 7 7 - 7 7 7 7 7 7 7 Output signal 0 10 4 ... 20 mA; two-wire system; power supply 7 ... 33 V DC (10 ... 30 V DC for ATEX versions) 0 ... 10 V; three-wire system; power supply 12 ... 33 V DC Explosion protection (only 4 ... 20 mA) 0 1 None With explosion protection Ex ia IIC T4 Electrical connection Connector per DIN EN 175301-803-A, stuffing box thread M16 (with coupling) Round connector M12 per IEC 61076-2-101 (not for gauge pressure ranges 16 bar) Connection via fixed mounted cable, 2 m (not for type of protection "Intrinsic safety i") Quickon cable quick screw connection PG9 (not for type of protection "Intrinsic safety i") Connector per DIN EN 175301-803-A, stuffing box thread 1/2"-14 NPT (with coupling) Connector per DIN EN 175301-803-A, stuffing box thread PG11 (with coupling) Fixed mounted cable, length 5 m Special version 0 0 0 1 2 3 4 5 6 7 9 N1Y Process connection G½" male per EN 837-1 (½" BSP male) (standard for metric pressure ranges mbar, bar) G½" male thread and G1/8" female thread G¼“ male per EN 837-1 (¼“ BSP male) 7/16"-20 UNF male A B C D ¼"-18 NPT male (standard for pressure ranges inH2O and psi) ¼"-18 NPT female ½"-14 NPT male ½"-14 NPT female 7/16"-20 UNF female M20x1.5 male E F G H J P Special version Z P1Y Sealing material between sensor and enclosure A B C D Z Viton (FPM, standard) Neoprene (CR) Perbunan (NBR) EPDM Special version Version Standard version 1 Further designs Supplement the Article No. with "-Z" and add Order code. Manufacturer’s test certificate M per IEC 60770-2 (calibration certificate) supplied C11 Oxygen application, oil and grease-free cleaning (only in conjunction with the sealing material Viton between sensor and enclosure and not with explosion portection version) E10 1/8 Siemens FI 01 · 2015 US Edition Q1Y © Siemens AG 2015 Pressure Measurement Transmitters for basic requirements SITRANS P200 for gauge and absolute pressure ■ Dimensional drawings 25.5 (1.0) G1/2" 25 (1.0) 25 (1.0) 20 (0.8) G1/8" M16x1.5 or 1/2-14 NPT 20 (0.8) M12x1/Fixcon 51 (2.0) 10.7 (0.42) 36 (1.42) M20 x 1.5 G1/2" 1/2-14 NPT 20 (0.8) 16 (0.6) G1/4" 7/16"-20 UNF 1/4-18 NPT max. 20 Nm 7/16"-20 UNF max. 20 Nm 23 (0.9) SITRANS P200, electrical connections, dimensions in mm (inch) 25 (1.0) Cable gland with cable 16 (0.6) 24 (0.94) 30 (1.2) 30.2 (1.19) max. 30 Nm 1/2"-14 NPT 1/2"-18 NPT max. 20 Nm SITRANS P200, process connections, dimensions in mm (inch) Siemens FI 01 · 2015 US Edition 1/9 1 © Siemens AG 2015 Pressure Measurement Transmitters for basic requirements 1 SITRANS P200 for gauge and absolute pressure ■ Schematics 1+ 1 2 IO Connection: 1 (+), 2 (-) + 2- UB RL IO Output current RL Load UB Power supply Connection with current output and connector per EN 175301 1+ IO UB RL 3- br IO gn UB RL 1 1+ IO 2- 4 3 1 UB 2 UO + UB RL 4+ 3- Connection: 1 (+UB), 3 (-), 4 (+UO) UO Output voltage RL Load UB Power supply Connection with voltage output and connector M12x1 br UO gn + UB RL ws Connection: br (+UB, brown), gn (+UO, green), ws (-, white) UO Output voltage UB Power supply RL Load Connection with voltage output and cable 1 Connection: 1 (+), 2 (-) + RL 1+ IO Output current UB Power supply RL Load Connection with current output and cable Connection: 1 (+UB), 2 (-), 3 (+UO) UO Output voltage RL Load UB Power supply Connection with voltage output and connector per EN 175301 Connection: br (brown), gn (green) + UB RL 2- IO Output current RL Load UB Power supply Connection with current output and connector M12x1 + UO 3+ Connection: 1 (+), 3 (-) + 3 1 1+ 1 3 2 IO Output current RL Load UB Power supply Connection with current output and Quickon cable quick screw connection 1+ 3+ 2 3 + UO RL UB 2- Connection: 1 (+UB), 3 (-), 2 (+UO) UO Output voltage RL Load UB Power supply Connection with voltage output and Quickon cable quick screw connection Version with explosion protection: 4 ... 20 mA The grounding connection is conductively bonded to the transmitter enclosure 1+ 1 2 2- + IO RL UB Connection: 1 (+), 2 (-) IO Output current RL Load UB Power supply Connection with current output and connector per EN 175301 (Ex) 1/10 Siemens FI 01 · 2015 US Edition 1+ 4 3 1 34 IO + RL UB Connection: 1 (+), 3 (-), 4( ) IO Output current RL Load UB Power supply Connection with current output and connector M12x1 (Ex)