© Siemens AG 2015 Pressure Measurement Transmitters for basic requirements 1 SITRANS P220 for gauge pressure ■ Overview ■ Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure. It can be used with a connector per EN 175301-803-A (IP65), a round plug M12 (IP67), a cable (IP67) or a Quickon cable quick screw connection (IP67) connected electrically. The output signal is between 4 and 20 mA or 0 and 10 V. Device structure with explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure. It can be used with a connector per EN 175301-803-A (IP65) or a round plug M12 (IP67) connected electrically. The output signal is between 4 and 20 mA. ■ Function The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. • Stainless steel measuring cell, fully welded • Measuring ranges 2.5 to 600 bar (36.3 to 8702 psi) relative • For high-pressure applications and refrigeration technology division U const. p High measuring accuracy Rugged stainless steel enclosure High overload withstand capability For aggressive and non-aggressive media For measuring the pressure of liquids, gases and vapors Compact design Gasket-less ■ Application The pressure transmitter SITRANS P220 for gauge pressure is used in the following industrial areas: • Mechanical engineering • Shipbuilding • Power engineering • Chemical industry • Water supply 1/16 Mode of operation U ■ Benefits • • • • • • • The pressure transmitter measures the gauge pressure of liquids and gases as well as the level of liquids. Siemens FI 01 · 2015 US Edition I I0, UB SITRANS P220 pressure transmitters (7MF1567-...), functional diagram The stainless steel measuring cell has a thick-film resistance bridge to which the operating pressure p is transmitted through a stainless steel diaphragm. The voltage output from the measuring cell is converted by an amplifier into an output current of 4 to 20 mA or an output voltage of 0 to 10 V DC. The output current and voltage are linearly proportional to the input pressure. © Siemens AG 2015 Pressure Measurement Transmitters for basic requirements SITRANS P220 for gauge pressure ■ Technical specifications Application Gauge pressure measurement Design Liquids, gases and vapors Mode of operation Measuring principle Piezoresistive measuring cell (stainless steel diaphragm) Measured variable Gauge pressure Weight Approx. 0.090 kg (0.198 lb) Process connections See dimension drawings Electrical connections • Connector per EN 175301-803-A Form A with cable inlet M16x1.5 or ½-14 NPT or Pg 11 • M12 connector • 2 or 3-wire (0.5 mm2) cable ( 5.4 mm) • Quickon cable quick screw connection Inputs Measuring range • Gauge pressure - Metric - US measuring range 2.5 … 600 bar (36 … 8700 psi) 30… 8700 psi Output Current signal 4 ... 20 mA • Load (UB - 10 V)/0.02 A • Auxiliary power UB DC 7 ... 33 V (10 ... 30 V for Ex) Voltage signal 0 ... 10 V DC Wetted parts materials • Measuring cell Stainless steel, mat.-No. 1.4016 • Process connection Stainless steel, mat. No. 1.4404 (SST 316 L) Non-wetted parts materials • Enclosure Stainless steel, mat. No. 1.4404 (SST 316 L) • Load 10 k • Rack Plastic • Auxiliary power UB 12 ... 33 V DC • cables PVC • Power consumption < 7 mA at 10 k Certificates and approvals Characteristic curve Linear rising Classification according to pressure equipment directive (PED 97/23/EC) For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) Lloyd‘s Register of Shipping (LR) 12/20010 Germanischer Lloyd (GL) GL19740 11 HH00 Measuring accuracy Error in measurement at limit setting incl. hysteresis and reproducibility Step response time T99 • Typical: 0.25 % of full-scale value • Maximum: 0.5 % of full-scale value < 5 ms Long-term stability American Bureau of Shipping (ABS) ABS_11_HG 789392_PDA Bureau Veritas (BV) BV 271007A0 BV Det Norske Veritas (DNV) A 12553 Influence of ambient temperature Drinking water approval (ACS) ACS 11 ACC NY 055 • Lower range value and measuring span 0.25 %/10 K of full-scale value GOST GOST-R • Influence of power supply 0.005 %/V • Lower range value and measuring span 0.25 % of full-scale value/year Underwriters Laboratories (UL) Conditions of use • for USA and Canada UL 20110217 - E34453 • worldwide IEC UL DK 21845 • Process temperature -30 ... +120 °C (-22 ... +248 °F) Explosion protection • Ambient temperature -25 ... +85 °C (-13 ... +185 °F) • Storage temperature -50 ... +100 °C (-58 ... +212 °F) Intrinsic safety "i" (only with current output) Ex II 1/2 G Ex ia IIC T4 Ga/Gb Ex II 1/2 D Ex ia IIIC T125 °C Da/Db EC type-examination certificate SEV 10 ATEX 0146 Connection to certified intrinsicallysafe resistive circuits with maximum values: Ui 30 V DC; Ii 100 mA; Pi 0.75 W Effective internal inductance and capacity for versions with plugs per EN 175301-803-A and M12 Li = 0 nH; Ci = 0 nF • Degree of protection (to EN 60529) • IP 65 with connector per EN 175301-803-A • IP 67 with M12 connector • IP 67 with cable • IP 67 with cable quick screw connection Electromagnetic compatibility • acc. IEC 61326-1/-2/-3 • acc. NAMUR NE21, only for ATEX versions and with a max. measuring deviation 1 % Siemens FI 01 · 2015 US Edition 1/17 1 © Siemens AG 2015 Pressure Measurement Transmitters for basic requirements 1 SITRANS P220 for gauge pressure ■ Selection and ordering data Article No. SITRANS P 220 pressure transmitters for gauge pressure, high-pressure and refrigeration applications, fully-welded version Accuracy typ. 0.25 % Wetted parts materials: stainless steel Non-wetted parts materials: stainless steel Order code 7M F 1 5 6 7 - 7 7 7 7 7 - 7 7 A 07 7 7 7 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Measuring range Overload limit Minimum Burst pressure Max. For gauge pressure 0 ... 2.5 bar 0 ... 4 bar 0 ... 6 bar 0 ... 10 bar (0 ... 36.3 psi) (0 ... 58 psi) (0 ... 87 psi) (0 ... 145 psi) -1 bar -1 bar -1 bar -1 bar (-14.5 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) 6.25 bar 10 bar 15 bar 25 bar (90.7 psi) (145 psi) (217 psi) (362 psi) 25 bar 40 bar 60 bar 60 bar (363 psi) (870 psi) (522 psi) (870 psi) 3 BD 3BE 3 BG 3 CA 0 ... 16 bar 0 ... 25 bar 0 ... 40 bar 0 ... 60 bar (0 ... 232 psi) (0 ... 363 psi) (0 ... 580 psi) (0 ... 870 psi) -1 bar -1 bar -1 bar -1 bar (-14.5 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) 40 bar 62.5 bar 100 bar 150 bar (580 psi) (906 psi) (1450 psi) (2175 psi) 96 bar 150 bar 240 bar 360 bar (1392 psi) (2176 psi) (3481 psi) (5221 psi) 3 CB 3 CD 3CE 3 CG 0 ... 100 bar 0 ... 160 bar 0 ... 250 bar 0 ... 400 bar 0 ... 600 bar (0 ... (0 ... (0 ... (0 ... (0 ... -1 bar -1 bar -1 bar -1 bar -1 bar (-14.5 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) 250 bar 400 bar 625 bar 1000 bar 1500 bar (3625 psi) (5801 psi) (9064 psi) (14503 psi) (21755 psi) 600 bar 960 bar 1500 bar 2400 bar 2500 bar (8702 psi) (13924 psi) (21756 psi) (34809 psi) (36260 psi) 3 DA 3 DB 3 DD 3DE 3 DG 1450 psi) 2320 psi) 3625 psi) 5801 psi) 8702 psi) 9 AA Other version, add Order code and plain text: Measuring range: ... up to... bar (psi) H1Y Measuring ranges for gauge pressure (only for US market) (0 ... 30 psi) (0 ... 60 psi) (0 ... 100 psi) (0 ... 150 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) (75 psi) (150 psi) (250 psi) (375 psi) (0 ... 200 psi) (0 ... 300 psi) (0 ... 500 psi) (0 ... 750 psi) (0 ... 1000 psi) (0 ... 1500 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) (500 psi) (750 psi) (1250 psi) (1875 psi) (2500 psi) (3750 psi) (0 ... 2000 psi) (0 ... 3000 psi) (0 ... 5000 psi) (0 ... 6000 psi (0 ... 8700 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) (-14.5 psi) (5000 psi) (7500 psi) (12500 psi) (15000 psi) (21000 psi) Other version, add Order code and plain text: Measuring range: ... up to ... psi (360 psi) (580 psi) (580 psi) (870 psi) (1390 psi) 4BE 4BF 4 BG 4 CA (2170 psi) (3480 psi) (5220 psi) (5220 psi) (8700 psi) 4 CB 4 CD 4CE 4CF 4 CG 4 DA (13920 psi) (21750 psi) (34800 psi) (34800 psi) (52200 psi) 4 DB 4 DD 4DE 4DF 4 DG 9 AA H1Y Output signal 4 ... 20 mA; two-wire system; power supply 7 ... 33 V DC (10 ... 30 V DC for ATEX versions) 0 ... 10 V; three-wire system; power supply 12 ... 33 V DC 0 10 Explosion protection (only 4 ... 20 mA) None With explosion protection Ex ia IIC T4 0 1 Electrical connection Connector per DIN EN 175301-803-A, stuffing box thread M16 (with coupling) Round connector M12 per IEC 61076-2-101 (not for gauge pressure ranges 16 bar) Connection via fixed mounted cable, 2 m (not for type of protection "Intrinsic safety i") Quickon cable quick screw connection PG9 (not for type of protection "Intrinsic safety i") Connector per DIN EN 175301-803-A, stuffing box thread 1/2"-14 NPT (with coupling) Connector per DIN EN 175301-803-A, stuffing box thread PG11 (with coupling) Fixed mounted cable, length 5 m Special version 1/18 Siemens FI 01 · 2015 US Edition 0 0 0 1 2 3 4 5 6 7 9 N1Y © Siemens AG 2015 Pressure Measurement Transmitters for basic requirements SITRANS P220 for gauge pressure ■ Selection and ordering data SITRANS P 220 pressure transmitters for gauge pressure, high-pressure and refrigeration applications, fully-welded version Accuracy typ. 0.25 % Wetted parts materials: stainless steel Non-wetted parts materials: stainless steel Article No. Order code 7M F 1 5 6 7 - 7 7 7 7 7 - 7 7 A 7 7 7 7 Process connection G½" male per EN 837-1 (½" BSP male) (standard for metric pressure ranges mbar, bar) G½" male thread and G1/8" female thread G¼“ male per EN 837-1 (¼“ BSP male) 7/16"-20 UNF male A B C D ¼"-18 NPT male (standard for pressure ranges inH2O and psi) ¼"-18 NPT female (Only for measuring ranges 60 bar (870 psi)) ½"-14 NPT male ½"-14 NPT female (Only for measuring ranges 60 bar (870 psi)) 7/16"-20 UNF female M20x1.5 male E F G H J P Special version Z Version Standard version P1Y 1 Further designs Supplement the Article No. with "-Z" and add Order code. Manufacturer’s test certificate M per IEC 60770-2 (calibration certificate) supplied C11 Oxygen application, oil and grease-free cleaning (Not in conjunction with explosion protection version) E10 Siemens FI 01 · 2015 US Edition 1/19 1 © Siemens AG 2015 Pressure Measurement Transmitters for basic requirements SITRANS P220 for gauge pressure ■ Dimensional drawings G1/2" 25 (1.0) 25 (1.0) 20 (0.8) G1/8" M16x1.5 or 1/2-14 NPT 20 (0.8) M12x1/Fixcon 51 (2.0) 10.7 (0.42) 36 (1.42) 25.5 (1.0) M20 x 1.5 G1/2" 1/2-14 NPT max. 30 Nm 24 (0.94) SITRANS P220, electrical connections, dimensions in mm (inch) 20 (0.8) 16 (0.6) Cable gland Quickon with or without cable 16 (0.6) 36 (1.42) G1/4" 7/16"-20 UNF 1/4-18 NPT 25 (1.0) max. 20 Nm 7/16"-20 UNF max. 20 Nm 23 (0.9) 30 (1.2) 1 1/2"-14 NPT 1/2"-18 NPT max. 20 Nm SITRANS P220, process connections, dimensions in mm (inch) 1/20 Siemens FI 01 · 2015 US Edition © Siemens AG 2015 Pressure Measurement Transmitters for basic requirements SITRANS P220 for gauge pressure ■ Schematics 1+ 1 2 IO Connection: 1 (+), 2 (-) + 2- UB RL IO Output current RL Load UB Power supply Connection with current output and connector per EN 175301 1+ IO UB RL 3- br IO gn UB RL 1 1+ IO 2- 4 3 1 UB 2 UO + UB RL 4+ 3- Connection: 1 (+UB), 3 (-), 4 (+UO) UO Output voltage RL Load UB Power supply Connection with voltage output and connector M12x1 br UO gn + UB RL ws Connection: br (+UB, brown), gn (+UO, green), ws (-, white) UO Output voltage UB Power supply RL Load Connection with voltage output and cable 1 Connection: 1 (+), 2 (-) + RL 1+ IO Output current UB Power supply RL Load Connection with current output and cable Connection: 1 (+UB), 2 (-), 3 (+UO) UO Output voltage RL Load UB Power supply Connection with voltage output and connector per EN 175301 Connection: br (brown), gn (green) + UB RL 2- IO Output current RL Load UB Power supply Connection with current output and connector M12x1 + UO 3+ Connection: 1 (+), 3 (-) + 3 1 1+ 1 3 2 IO Output current RL Load UB Power supply Connection with current output and cable quick screw connection Quickon 1+ 3+ 2 3 + UO RL UB 2- Connection: 1 (+UB), 3 (-), 2 (+UO) UO Output voltage RL Load UB Power supply Connection with voltage output and cable quick screw connection Quickon Version with explosion protection: 4 ... 20 mA The grounding connection is conductively bonded to the transmitter enclosure 1+ 1 2 2- + IO RL UB Connection: 1 (+), 2 (-) IO Output current RL Load UB Power supply Connection with current output and connector per EN 175301 (Ex) 1+ 4 3 1 34 IO + RL UB Connection: 1 (+), 3 (-), 4( ) IO Output current RL Load UB Power supply Connection with current output and connector M12x1 (Ex) Siemens FI 01 · 2015 US Edition 1/21 1