DC-DC Converter Bricks, Open/Enclosed BAS SERIES, 1/16 BRICK, UP TO 60W FEATURES: 5 year warranty Output current up to 30A 1500Vdc isolation voltage Efficiency up to 91% Operating temperature range -40 Under voltage, over current, short circuit, ℃ to +85 ℃ over voltage protection Remote on/off Adjustable output voltage Model BAS48-12V30 BAS48-33V15 BAS48-33V10 BAS48-33V20 BAS48-50V6 BAS48-50V12 Input voltage (Vdc) Output voltage (Vdc) Output current (A) Efficiency Typ. 1.2 30.0 83% 3.3 15.0 89% 3.3 10.0 89% 3.3 20.0 89% 5.0 6.0 91% 5.0 12.0 89% 48(36~72) Notes: 1. Other input and output models may available on request; 2. You may request the models for different packages: Through hole package and SMT package; for SMT package, plus “SMT” in the suffix, e.g. BAS48-12V30SMT. ELECTRICAL Input voltage range 48Vdc 36-72Vdc ON: Low level or grounded Negative logic OFF: High level or close Remote control OFF: Low level or grounded Positive logic ON: High level or open Output power Input voltage range Output voltage Single output 1.2/1.8/3.3/5.0Vdc Output voltage adjustable Positive logic ±10% Line regulation Full load ±0.2% Load regulation 10%-100% full load ±0.5% Dynamic response (transient/recovery time) 33-66W 25%-50%-75% load capability Ripple and noise Parallel test, 20MHz wide range Isolation voltage Input to output Isolation resistance --- www.pairuigroup.com ∆Vo/∆t: ±4.0%/500μs 75mVp-p max. 1500Vdc 10MΩ Page: 1/4 Date: 11/07/2015 DC-DC Converter Bricks, Open/Enclosed BAS SERIES, 1/16 BRICK, UP TO 60W ELECTRICAL IEC-60950-1, UL-60950-1 Safety --- Temperature coefficient --- Operating temperature range Auxiliary heat sink Storage temperature range --- Over temperature protection Typical Under voltage protection --- Yes Over current protection --- Yes Short circuit protection --- Yes Over voltage protection --- Yes Relative humidity --- 95% max. MTBF Bellcore TR-332, 25 EN-60950-1, GB4943 300ppm ℃ to +85℃ -40℃ to +125℃ 110℃ typ. -40 ℃ 2000KHrs Notes: All the parameters are measured at 25℃ ambient temperature, humidity < 75%, nominal input voltage, full load and after warm-up, unless otherwise specified. MECHANICAL THROUGH HOLE PACKAGE www.pairuigroup.com SMT PACKAGE Page: 2/4 Date: 11/07/2015 DC-DC Converter Bricks, Open/Enclosed BAS SERIES, 1/16 BRICK, UP TO 60W MECHANICAL PCB LAYOUT CONNECTION PIN # SINGLE 1 +Vin 2 REM 3 -Vin 4 GND 5 -S 6 TRIM 7 +S 8 +Vo Note: * Unit is mm(inch). DERATING CURVE www.pairuigroup.com EFFICIENCY CURVE Page: 3/4 Date: 11/07/2015 DC-DC Converter Bricks, Open/Enclosed BAS SERIES, 1/16 BRICK, UP TO 60W NOTES RECOMMENDED TEST AND APPLICATION CIRCUIT 1. TVS&FUSE be helpful with over voltage protection and inrush limiting. Recommended FUSE better be 1.5~2times of the rated current . 2. The input filter capacitor C6 could select the aluminum electrolytic capacitors or tantalum capacitors, and the withstand voltage should be greater than the highest input voltage. Recommended capacitor should be between 22μF~100μF. 3. C1,C2 for the input filter capacitor,0.1~1μF high-frequency ceramics capacitor or chip capacitor are recommended. The withstand voltage of output filter C5, C7 should be greater than the highest output voltage. Recommended capacitor of C7 better within 100μF and C5 connected with the chip to reduce the input voltage peak, recommended 0.1~1μF high-frequency ceramics capacitor or chip capacitor. www.pairuigroup.com Page: 4/4 Date: 11/07/2015