Axial Lead and Cartridge Fuses Designed to IEC Standard Pb RoHS 5 x 20 mm Time Lag Fuse (Slo-Blo ) Fuse 213 Series ® ® ® • Designed to International (IEC) Standards for use globally. • Meets the IEC 60127-2, Sheet 3 specification for Time Lag Fuses. • Available in Cartridge and Axial Lead Form. • Available in ratings of 0.200 to 6.3 amperes. • RoHS compliant and Lead-Free version available, add XP suffix to standard catalog number ELECTRICAL CHARACTERISTICS (213 Series): 150% 210% 275% 400% 1000% Ampere Rating .032 – 6.3 8 - 15 Opening Time 60 minutes, Minimum 30 minutes, Minimum .032 – 15 .032 – .100 .125 – 15 .032 – .100 .125 – 15 .032 – .100 .125 – 15 2 minutes, Maximum 0.2 sec., Min.; 10 sec. Max. 0.6 sec., Min.; 10 sec. Max. .04 sec., Min.; 3 sec. Max. .15 sec., Min.; 3 sec. Max. .01 sec., Min.; 0.3 sec. Max. 0.02 sec., Min.; 0.3 sec. Max. INTERRUPTING RATINGS: 35 amperes or 10 x rated current; (whichever is greater) to a maximum 100A @ 250 VAC, unity power factor. ORDERING INFORMATION: RoHS compliant and Lead-Free version available, add XP suffix to standard catalog number 213 Surge Withstand Cartridge Catalog Number 0213.200 0213.250 0213.315 0213.400 0213.500 0213.630 0213.800 0213 001 0213 1.25 0213 01.6 0213 002. 0213 02.5 0213 3.15 0213 004 0213 005. 0213 06.3 Ampere Rating Voltage Rating .200 .250 .315 .400 .500 .630 .800 1 1.25 1.6 2 2.5 3.15 4 5 6.3 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 Nominal Resistance Cold Ohms 1.60 1.05 0.848 0.535 0.370 0.275 0.165 0.117 0.081 0.055 0.044 0.030 0.022 0.017 0.011 0.008 Nominal Melting I2t A2Sec. 0.350 0.555 1.14 1.35 2.90 4.80 9.42 19.20 27.15 44.2 92.7 138.0 226.5 202 314 600 ENVIRONMENTAL SPECIFICATIONS: Operating temperature: -55˚C to 125˚C Thermal Shock: MIL-STD-202F Method 107G, Test Condition B: (5 cycles –65°C to +125°C) Vibration: MIL-STD-202F Method 201A Humidity: MIL-STD-202F Method 103B, Test Condition A. high relative humidity (95%) and elevated temperature (40°C) for 240 hours. Salt Spray: MIL-STD-202F Method 101D, Test Condition B PHYSICAL SPECIFICATIONS: Material: Body: Glass Cap: Nickel Plated Brass Leads: Tin Plated Copper Terminal Strength: MIL-STD-202F Method 211A, Test Condition A Solderability: Reference IEC 60127 Second Edition 2003-01 Annex A Product Marking: Cap 1: current and voltage rating. Cap 2: Agency approval markings. Packaging: Available in Bulk (v=5, H=100, M=1000 pcs/pkg) or on Tape/Reel (MRET1=1000 pcs/reel). w w w. l i t t e l f u s e . c o m 411 11 AXIAL LEAD AND CARTRIDGE FUSES % of Ampere Rating Axial Lead and Cartridge Fuses Designed to IEC Standard RoHS Pb 5 x 20 mm Time Lag Fuse (Slo-Blo ) Fuse 213 Series ® ® ® Agency Approvals Agency Approvals Certificate No Ampere Range Cartridge NBK120802-E10480 A&C Leaded NBK120802-E10480 B&D Certificate No. 2002010207007597 2003010207045592 20+0.5 0213 0002 1A – 6.3A 5.1+0.6 200mA – 6.3A 5A File No. Acc. Class No. ® 40 200mA – 6.3A File No. 9905092, 9923025, 304515 Notes: * Ratings above 6.3A have 0.8 mm dia lead 1 For RoHS compliant parts replace XE with XEP 2 For RoHS compliant parts add suffix 'XP' 0.200A 0.250A 0.315A 0.400A 0.500A 0.630A 0.800A 1A 1.25A 1.6A 2A 2.5A 3.15A 4A 5A 6.3A Average Time Current Curves 10000 1000 TIME IN SECONDS 100 10 1 0.1 0.01 10 100 1000 CURRENT IN AMPERES 412 5.8 MAX All dimensions in mm KM41462 1 22.5 MAX 0.65 029862 LR1422-30 Licence No. 0.001 0.1 5.1+0.6 0213 000 XE1 Recognised File No. E10480 Guide No. JDYX2 ® 5.2+0.1 -0.2 w w w. l i t t e l f u s e . c o m Axial Lead and Cartridge Fuses Designed to IEC Standard RoHS Pb 5 x 20 mm Time Lag Fuse (Slo-Blo ) Fuse 218 Series ® ® ® • Designed to International (IEC) Standards for use globally. • Meets the IEC 60127-2, Sheet 3 specification for Time Lag Fuses. • Available in Cartridge and Axial Lead Form. • Available in ratings of 0.032 to 15 amperes. • RoHS compliant and Lead-Free version available, add XP suffix to standard catalog number ELECTRICAL CHARACTERISTICS (218 Series): 150% 210% 275% 400% 1000% Ampere Rating .032 – 6.3 8 - 15 Opening Time 60 minutes, Minimum 30 minutes, Minimum .032 – 15 .032 – .100 .125 – 15 .032 – .100 .125 – 15 .032 – .100 .125 – 15 2 minutes, Maximum 0.2 sec., Min.; 10 sec. Max. 0.6 sec., Min.; 10 sec. Max. .04 sec., Min.; 3 sec. Max. .15 sec., Min.; 3 sec. Max. .01 sec., Min.; 0.3 sec. Max. 0.02 sec., Min.; 0.3 sec. Max. INTERRUPTING RATINGS: 35 amperes or 10 x rated current; (whichever is greater) to a maximum 100A @ 250 VAC, unity power factor. ORDERING INFORMATION: RoHS compliant and Lead-Free version available, add XP suffix to standard catalog number 218 Cartridge Catalog Number Ampere Rating Voltage Rating Nominal Resistance Cold Ohmns Nominal Melting I2t A2Sec. 218.032 218.040 218.050 218.063 218.080 218.100 218.125 218.160 218.200 218.250 218.315 218.400 218.500 218.630 218.800 218 001 218 1.25 218 01.6 218 002 218 02.5 218 3.15 218 004 218 005 218 06.3 218 008 218 010 218 015 .032 .040 .050 .063 .080 .100 .125 .160 .200 .250 .315 .400 .500 .630 .800 1 1.25 1.6 2 2.5 3.15 4 5 6.3 8 10 15 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 58.45 35.70 23.30 18.1 12.6 8.95 4.41 2.44 1.60 1.05 0.848 0.535 0.370 0.275 0.073 0.055 0.042 0.032 0.029 0.022 0.017 0.013 0.010 0.0075 0.0059 0.0045 0.0030 0.00305 0.0055 0.0071 0.012 0.0265 0.0495 0.150 0.225 0.350 0.555 1.14 1.35 2.90 4.80 1.99 3.33 5.80 10.61 14.80 23.85 39.20 70.95 114.0 204.0 350.5 583.0 1441.0 ENVIRONMENTAL SPECIFICATIONS: Operating temperature: -55˚C to 125˚C Thermal Shock: MIL-STD-202F Method 107G, Test Condition B: (5 cycles –65°C to +125°C) Vibration: MIL-STD-202F Method 201A Humidity: MIL-STD-202F Method 103B, Test Condition A. high relative humidity (95%) and elevated temperature (40°C) for 240 hours. Salt Spray: MIL-STD-202F Method 101D, Test Condition B PHYSICAL SPECIFICATIONS: Material: Body: Glass Cap: Nickel Plated Brass Leads: Tin Plated Copper Terminal Strength: MIL-STD-202F Method 211A, Test Condition A Solderability: Reference IEC 60127 Second Edition 2003-01 Annex A Terminal strength: MIL-STD-202F Method 211A, Test Condition A Product Marking: Cap 1: current and voltage rating. 11 Cap 2: Agency approval markings. Packaging: Available in Bulk (v=5, H=100, M=1000 pcs/pkg) or on Tape/Reel (MRET1=1000 pcs/reel). w w w. l i t t e l f u s e . c o m AXIAL LEAD AND CARTRIDGE FUSES % of Ampere Rating 413 Axial Lead and Cartridge Fuses Designed to IEC Standard RoHS Pb 5 x 20 mm Time Lag Fuse (Slo-Blo ) Fuse 218 Series ® ® ® Agency Approvals Agency Approvals Certificate No. Ampere Range Cartridge NBK120802-E10480 A&C Leaded NBK120802-E10480 B&D 20+0.5 5.2+0.1 -0.2 0218 0002 1A – 15A 5.1+0.6 Certificate No. 2002010207007596 32mA – 6.3A Certificate No. SU05001-3005 SU05001-2008 SU05001-2009 32mA – 40mA 50mA – 800mA 1A – 10A 0218.032 XE1 to 0218.100XE1 40 5.1+0.6 22.5 MAX 6.0 MAX 0.65 Recognised File No. E10480 Guide No. JDYX2 ® 32mA – 15A ® 0218.125 XE1 to 0218015. XE1 File No. Acc. Class No. 029862 LR1422-30 Licence No. KM41462 File No. 9850004, 9840179, 9446070, 9708209, 9843043, 312377 & 304650 40 22.5 MAX 5.8 MAX 0.65* 80mA – 6.3A All dimensions in mm 32mA – 6.3A Notes: * Ratings above 6.3A have 0.8 mm dia lead 1 For RoHS compliant parts replace XE with XEP 2 For RoHS compliant parts add suffix 'XP' 32mA – 15A Note: 8A and 10A are under consideration by IEC(125V). 15A 0.032A 0.040A 0.050A 0.063A 0.080A 0.100A 0.125A 0.160A 0.200A 0.250A 0.315A 0.400A 0.500A 0.630A 0.800A 1A 1.25A 1.6A 2A 2.5A 3.15A 4A 5A 6.3A 8A 10A Average Time Current Curves 10000 1000 TIME IN SECONDS 100 10 1 0.1 0.01 0.001 0.01 0.01 0.1 1 10 100 0.1 1 10 100 1000 1000 CURRENT IN AMPERES 414 w w w. l i t t e l f u s e . c o m