LITTELFUSE P2500S_L

LCAS Asymmetrical Discrete Device
RoHS
¨
®
These DO-214AA SIDACtor devices are intended for LCAS (Line Circuit Access Switch)
applications that require asymmetrical protection in discrete (individual) packages. They
enable the protected equipment to meet various regulatory requirements including
GR 1089, ITU K.20, K.21, K.45, IEG 60950, UL 60950, and TIA-968-A (formerly known as
FCC Part 68).
Electrical Parameters
Part
Number *
VDRM
Volts
VS
Volts
VT
Volts
IDRM
µAmps
IS
mAmps
IT
Amps
IH
mAmps
P1200S_L
100
130
4
5
800
2.2
120
P2000S_L
180
220
4
5
800
2.2
120
P2500S_L
230
290
4
5
800
2.2
120
* “L” in part number indicates RoHS compliance. For non-RoHS compliant device, delete “L” from part number.
For individual “SA”, “SB”, and “SC” surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• Listed SIDACtor® devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• VDRM is measured at IDRM.
• VS is measured at 100 V/µs.
• Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request.
Surge Ratings in Amps
Series
IPP
0.2x310 * 2x10 *
8x20 *
0.5x700 ** 2x10 ** 1.2x50 **
10x160 *
10x160 **
10x560 *
10x560 **
5x320 *
9x720 **
Amps
Amps
Amps
Amps
Amps
Amps
A
20
150
150
90
50
B
25
250
250
150
100
C
50
500
400
200
150
200
10x360 * 10x1000 * 5x310 *
ITSM
10x360 ** 10x1000 ** 10x700 ** 50 / 60 Hz
Amps
Amps
75
75
100
125
175
di/dt
Amps
Amps
Amps/µs
45
75
20
500
80
100
30
500
100
200
50
500
* Current waveform in µs
** Voltage waveform in µs
www.littelfuse.com
3 - 60
© 2006 Littelfuse • Telecom Design Guide
LCAS Asymmetrical Discrete Device
Thermal Considerations
Symbol
TJ
Operating Junction Temperature Range
Parameter
-40 to +150
°C
TS
Storage Temperature Range
-65 to +150
°C
90
°C/W
Thermal Resistance: Junction to Ambient
RθJA
Value
Unit
SIDACtor Devices
Package
DO-214AA
Capacitance Values
pF
Part Number
MIN
MAX
P1200SAL
30
45
P1200SBL
30
65
P1200SCL
45
110
P2000SAL
25
35
P2000SBL
25
95
P2000SCL
35
95
P2500SAL
20
35
P2500SBL
20
35
P2500SCL
30
85
Note: Off-state capacitance (CO) is measured at 1 MHz with a 2 V bias.
Telecom Design Guide • © 2006 Littelfuse
3 - 61
www.littelfuse.com
LCAS Asymmetrical Discrete Device
IPP – Peak Pulse Current – %IPP
+I
IT
IS
IH
IDRM
-V
+V
VT
VDRM
VS
Peak
Value
100
tr = rise time to peak value
td = decay time to half value
Waveform = tr x td
50
Half Value
0
0
tr
td
t – Time (µs)
-I
14
12
10
IH
8
6
25 ˚C
4
2
IH (TC = 25 ˚C)
tr x td Pulse Waveform
Ratio of
Percent of VS Change – %
V-I Characteristics
0
-4
2.0
1.8
1.6
1.4
25 ˚C
1.2
1.0
0.8
0.6
0.4
-40 -20 0
-6
-8
-40 -20
0
20 40 60 80 100 120 140 160
Case Temperature (TC) – ˚C
20 40 60 80 100 120 140 160
Junction Temperature (TJ) – ˚C
Normalized VS Change versus Junction Temperature
www.littelfuse.com
Normalized DC Holding Current versus Case Temperature
3 - 62
© 2006 Littelfuse • Telecom Design Guide