SIEMENS Product data sheet 82ADC4FBH NEMA Slim Line pump panel NEMA size 1 3-Phase, 3-Pole Maximum voltage rating 600VAC Max Hp 60Hz: 0@200V; 0@230V; 5@460V; 0@575V Solid-state overload relay with 3–12A range Control voltage 460 V 60Hz NEMA Type 3/3R enclosure Image is representative and may not depict the actual product. General technical data: Weight Height x Width x Depth Finger-safe (main circuit / control circuit) Maximum altitude Ambient storage temperature Ambient operating temperature Humidity (% non-condensing) Rated impulse voltage resistance Rated insulation voltage Country of origin Contactor: Number of NO main contacts Amp rating Mechanical operating cycles Internal/standard auxiliary contact: Number of NC / NO auxiliary contacts Rating Optional auxiliary contact: Max number of NC / NO auxiliary contacts Rating Coil: Voltage Sealed watts Inrush / sealed power Normal coil operating limits (% of rated voltage) Typical drop-out volts (% of rated voltage) Pick-up time / Drop-out time Overload Relay: Current range Trip Class Trip detection Phase failure sensitivity Repeat accuracy Reset options External reset Test function Conformal coating on printed circuit board Number of NC / NO auxiliary contacts Rating of auxiliary contacts Siemens Industry, Inc. 3333 Old Milton Parkway, Alpharetta, GA 30005 Subject to change without prior notice. 23 lb 26 x 12 x 5 in. NA / NA 6560 ft (-30 to 65)°C / (-22 to 149)°F (-20 to 40)°C / (-4 to 104)°F (no data) (no data) (no data) USA 3 32A 10,000,000 1NC / 1NO A600 AC / Q600 DC 2NC / 2NO A300 AC / Q300 DC 460 V 60Hz Coil (no data) 81 / 10.5 VA 85% - 110% 55% 8-40 / 4-16 msec 3–12A Class 5 / 10 (factory set) / 20 / 30 Overload, phase failure, phase unbalance, ground fault Trip time after phase-loss: < 3 sec Within 1% Manual, automatic and remote Yes Electronics & manual actuation Yes 1NC / 1NO 5A@600VAC (B600), 1A@250VDC (R300) 11/20/2014 82ADC4FBH Page 1 of 4 Single contact isolation Dual contact isolation Disconnect Switch: Rating Fuse type accepted Enclosure: Type Rating Standard Control Devices: Hand-Off-Auto selector switch Mounting/wiring: Mounting orientation Mounting type Line side connection type / torque Line side solid & stranded conductors 3-pt power TB (load side) connection type / torque 3-pt power TB (load side) solid & stranded conductors 3-pt control terminal block connection type / torque 3-pt control terminal block solid & stranded conductors Coil connection type / torque Coil solid & stranded conductors Main auxiliary contact connection type / torque Main auxiliary contact solid & stranded conductors OLR auxiliary contact connection type / torque OLR auxiliary contact solid & stranded conductors Short circuit current rating: Fuses Certificates/approvals: 600V 300V differing polarity / 600V common polarity 30A with 30A/600V Class H fuse clips Class H, J (convertible), K and R NEMA Type 3/3R enclosure Weather proof for outdoor use 30mm metal housing with chrome finish Vertical Surface Box lug / 35 lb in (14 - 10); 40 lb in (8); 45 lb in (6 - 4) AWG 1x(14 - 2 AWG) 60/75°C AL or CU Screw / 24 - 32 lb-in. 1x(18 - 2 AWG) 75°C CU Screw / 12 - 18 lb-in. 1x(22 - 8 AWG) 75°C CU Screw / 7 lb in. - 10 lb in. 2 x (16 - 12 AWG) CU 60/75°C Screw / 7- 10 lb-in 2 x (20 - 16 AWG), 2 x (18 - 14 AWG) 75°C CU Screw / 7 lb in. - 10 lb in. 2 x (20 - 14 AWG) CU 60/75°C 10kA@600V (Class H or K); 100kA@600V (Class R or J) UL (file no. E185287) cUL (file no. E185287 for Canada) ISO 9001 certification Additional information: OLR instruction sheet & trip curves Siemens Industry, Inc. 3333 Old Milton Parkway, Alpharetta, GA 30005 Subject to change without prior notice. 11/20/2014 82ADC4FBH Page 2 of 4 Siemens Industry, Inc. 3333 Old Milton Parkway, Alpharetta, GA 30005 Subject to change without prior notice. 11/20/2014 82ADC4FBH Page 3 of 4 Siemens Industry, Inc. 3333 Old Milton Parkway, Alpharetta, GA 30005 Subject to change without prior notice. 11/20/2014 82ADC4FBH Page 4 of 4