82ADD4FBH-DataSheet

SIEMENS
Product data sheet
82ADD4FBH
NEMA Slim Line pump panel
NEMA size 1
3-Phase, 3-Pole
Maximum voltage rating 600VAC
Max Hp 60Hz: 0@200V; 0@230V; 10@460V; 0@575V
Solid-state overload relay with 5.5–22A range
Control voltage 460 V 60Hz
NEMA Type 3/3R enclosure
Image is representative and may not depict the actual product.
General technical data:
Weight
Height x Width x Depth
Finger-safe (main circuit / control circuit)
Maximum altitude
Ambient storage temperature
Ambient operating temperature
Humidity (% non-condensing)
Rated impulse voltage resistance
Rated insulation voltage
Country of origin
Contactor:
Number of NO main contacts
Amp rating
Mechanical operating cycles
Internal/standard auxiliary contact:
Number of NC / NO auxiliary contacts
Rating
Optional auxiliary contact:
Max number of NC / NO auxiliary contacts
Rating
Coil:
Voltage
Sealed watts
Inrush / sealed power
Normal coil operating limits (% of rated voltage)
Typical drop-out volts (% of rated voltage)
Pick-up time / Drop-out time
Overload Relay:
Current range
Trip Class
Trip detection
Phase failure sensitivity
Repeat accuracy
Reset options
External reset
Test function
Conformal coating on printed circuit board
Number of NC / NO auxiliary contacts
Rating of auxiliary contacts
Siemens Industry, Inc.
3333 Old Milton Parkway, Alpharetta, GA 30005
Subject to change without prior notice.
23 lb
26 x 12 x 5 in.
NA / NA
6560 ft
(-30 to 65)°C / (-22 to 149)°F
(-20 to 40)°C / (-4 to 104)°F
(no data)
(no data)
(no data)
USA
3
32A
10,000,000
1NC / 1NO
A600 AC / Q600 DC
2NC / 2NO
A300 AC / Q300 DC
460 V 60Hz Coil
(no data)
81 / 10.5 VA
85% - 110%
55%
8-40 / 4-16 msec
5.5–22A
Class 5 / 10 (factory set) / 20 / 30
Overload, phase failure, phase unbalance, ground fault
Trip time after phase-loss: < 3 sec
Within 1%
Manual, automatic and remote
Yes
Electronics & manual actuation
Yes
1NC / 1NO
5A@600VAC (B600), 1A@250VDC (R300)
11/20/2014
82ADD4FBH
Page 1 of 4
Single contact isolation
Dual contact isolation
Disconnect Switch:
Rating
Fuse type accepted
Enclosure:
Type
Rating
Standard Control Devices:
Hand-Off-Auto selector switch
Mounting/wiring:
Mounting orientation
Mounting type
Line side connection type / torque
Line side solid & stranded conductors
3-pt power TB (load side) connection type / torque
3-pt power TB (load side) solid & stranded conductors
3-pt control terminal block connection type / torque
3-pt control terminal block solid & stranded conductors
Coil connection type / torque
Coil solid & stranded conductors
Main auxiliary contact connection type / torque
Main auxiliary contact solid & stranded conductors
OLR auxiliary contact connection type / torque
OLR auxiliary contact solid & stranded conductors
Short circuit current rating:
Fuses
Certificates/approvals:
600V
300V differing polarity / 600V common polarity
30A with 30A/600V Class H fuse clips
Class H, J (convertible), K and R
NEMA Type 3/3R enclosure
Weather proof for outdoor use
30mm metal housing with chrome finish
Vertical
Surface
Box lug / 35 lb in (14 - 10); 40 lb in (8); 45 lb in (6 - 4) AWG
1x(14 - 2 AWG) 60/75°C AL or CU
Screw / 24 - 32 lb-in.
1x(18 - 2 AWG) 75°C CU
Screw / 12 - 18 lb-in.
1x(22 - 8 AWG) 75°C CU
Screw / 7 lb in. - 10 lb in.
2 x (16 - 12 AWG) CU 60/75°C
Screw / 7- 10 lb-in
2 x (20 - 16 AWG), 2 x (18 - 14 AWG) 75°C CU
Screw / 7 lb in. - 10 lb in.
2 x (20 - 14 AWG) CU 60/75°C
10kA@600V (Class H or K); 100kA@600V (Class R or J)
UL (file no. E185287)
cUL (file no. E185287 for Canada)
ISO 9001 certification
Additional information:
OLR instruction sheet & trip curves
Siemens Industry, Inc.
3333 Old Milton Parkway, Alpharetta, GA 30005
Subject to change without prior notice.
11/20/2014
82ADD4FBH
Page 2 of 4
Siemens Industry, Inc.
3333 Old Milton Parkway, Alpharetta, GA 30005
Subject to change without prior notice.
11/20/2014
82ADD4FBH
Page 3 of 4
Siemens Industry, Inc.
3333 Old Milton Parkway, Alpharetta, GA 30005
Subject to change without prior notice.
11/20/2014
82ADD4FBH
Page 4 of 4