www.usa.siemens.com/controls NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry. Class 82 Slim Line NEMA Pump Controller Typical applications include: •Crop irrigation •Sprinklers, misters and soakers •Watering for livestock and other dairy applications •Ground dewatering for excavation and construction sites Siemens introduces its new Class 82 slim line NEMA Pump Panel. This newest addition to the already extensive line of Siemens pump panels was designed specifically for the agricultural market. It is well suited for irrigation and similar pumping applications and is built to withstand the harsh elements of the outdoors. Why you should use the Class 82 Pump Panel • Simplicity and its compact lightweight design makes this an attractive solution to your budgeting challenges. • The contactor is NEMA rated to provide reliable motor control and protection expected in the most demanding applications. • The ESP200 solid-state overload relay has a protective coating on the circuit board which gives it superior protection against high humidity, condensation and corrosive environments. • Its size and weight is about half that of the Class 87 which increases the ease of installation. Product Selection Max Hp Rating Motor Voltage Catalog Number Overload Relay Amp Range Disc. Amp Rating Fuse Clip Amp/Volts HOA Only HOA & Start Push Button 0.75–3.4 30 30A/600V 82ADB4FBH 82ADB6FBH 230 460 NEMA Size — 1 1 — 5 1 3–12 30 30A/600V 82ADC4FBH 82ADC6FBH — 10 1 5.5–22 30 30A/600V 82ADD4FBH 82ADD6FBH 82ADC6FAG 2 — 1 3–12 30 30A/250V 82ADC4FAG 3 — 1 5.5–22 30 30A/250V 82ADD4FAG 82ADD6FAG 7 1/2 — 1 10–40 30 30A/250V 82ADE4FAG 82ADE6FAG Accessories Image Description 3/4" Type 3R Conduit Hub Part Number ECHS075 1" Type 3R Conduit Hub ECHS100 1 1/4" Type 3R Conduit Hub ECHS125 1 1/2" Type 3R Conduit Hub ECHS150 Disconnect Switch Auxiliary Contacts 2 NO/2 NC DPDT (NEMA A600) HA261234 Fuse Puller Kit For 30A Switch (1 kit required per switch) HP61 30A, 240V Class R Fuse Clip Kits HR21 30A, 600V Class R Fuse Clip Kits HR612 Contactor Auxiliary Contacts, Side Mounted 1 NO/NC 3RH29111DA11 (NEMA A300/Q300) 2 ESP200 Tamper Resistance Cover 49ASTC1 Start Push Button With Contact Block 52PA8A1K Start Legend Plate 52NL03 Features and Benefits D C A Compact and light-weight NEMA type 3/3R enclosure for ease of installation. Fabricated with galvanized steel versus conventional cold rolled steel for superior corrosion resistance. B Two lockable latches to tightly seal door. C Drip shield to help prevent water entry. D Pole straps at top and bottom of enclosure for easy E mounting on poles or flat surfaces using keyhole slots. E Rugged metal handle with lock-out provision for durability. A B 9.5” Class 87 22” 24” -60% 20” 3 Features and Benefits H G F Metal 30 mm H-O-A switch and Start push button are water and dust tight. G Full gasketed door to ensure a dust tight and water tight seal. J H Pre-punched opening with cover plate for convenient field installation of a conduit hub should top entry be required. I Multiple conduit knockouts for convenient field installation of conduit should bottom entry be required. K J Heavy-duty disconnect switch with line-side shield and visible blades for safety and double break switch action to reduce arcing and increase lifetime. L K NEMA rated contactor to provide reliable motor control and protection expected in the most demanding applications. L ESP200 solid-state overload relay with protective coating on circuit board which gives it superior protection against high humidity, condensation and corrosive environments. F M N M 3-point terminal strips, as standard, for convenient field connections N 3-point ground lug. 4 I Nomenclature 82 A D C 4 F B H Series Starter Size D=1 OLR Current Range B = 0.75 - 3.4A C = 3 - 12A D = 5.5 - 22A E = 10 - 40A Cover Control 4 = HOA selector switch only 6 = HOA selector switch with Start push button Disconnect Type F = Fusible Disconnect Disconnect & Fuse Clip Rating A = 30A/250V B = 30A/600V Coil Voltage G = 220VAC 50Hz / 240VAC 60Hz H = 480VAC 60Hz 5 Technical Data General Technical Data: Weight Height x Width x Depth Maximum altitude Ambient (outside enclosure) storage temperature Ambient (outside enclosure) operating temperature Country of origin 23 lb. 26 x 12 x 5 in. 6560 ft. (-30 to 65)°C / (-22 to 149)°F (-20 to 40)°C / (-4 to 104)°F USA Horsepower Rating: 82ADB*FBH 1Hp@460VAC (NEMA size 1) 82ADC*FBH 5Hp@460VAC (NEMA size 1) 82ADD*FBH 10Hp@460VAC (NEMA size 1) 82ADC*FAG 2Hp@230VAC (NEMA size 1) 82ADD*FAG 3Hp@230VAC (NEMA size 1) 82ADE*FAG 7 1/2Hp@230VAC (NEMA size 1) Contactor: Number of NO main contacts Amp rating Mechanical operating cycles 3 32A 10,000,000 Internal / Standard Auxiliary Contact Number of NC / NO auxiliary contacts NEMA contact rating designation Optional auxiliary contacts available 1NC / 1NO A600 AC / Q600 DC Yes Coil: Voltage Apparent pull-in / holding power Normal coil operating limits (% of rated voltage) Pick-up time / Drop-out time 220/230 V 50/60 Hz or 460 V 60Hz 81 VA / 10.5 VA 80% - 110% at 60Hz 8-40 / 4-16 msec Overload Relay: Current range Trip Class Trip detection Phase failure sensitivity Repeat accuracy Reset options External reset Test function Conformal coating on printed circuit board Number of NC / NO auxiliary contacts Rating of auxiliary contacts Single contact isolation Dual contact isolation 0.75 - 3.4 or 3 - 12 or 5.5 - 22 or 10 - 40 Amps Class 5 / 10 / 20 (factory set) / 10 Overload, phase failure, phase unbalance, ground fault Trip time after phase loss: < 3 sec Within 1% Manual, automatic and remote Yes Electronics and manual actuation Yes 1NC /1NO B600 AC / R300 DC 600 V 300 V differing polarity / 600 V common polarity Disconnect Switch: Rating Fuse type accepted 30 A with 30A/600 or 30A/250 V Class H fuse clips Class H, J or R Enclosure: Type Rating NEMA Type 3/3R enclosure Weather proof for outdoor use Standard Control Devices: Hand-Off-Auto selector switch (both 4 & 6 cover control) Start push button (6 cover control only) 30mm metal housing with chrome finish 30mm metal housing with chrome finish Mounting / Wiring: Mounting orientation Mounting type Disconnect line side connection type / torque Disconnect line side solid and stranded conductors Power terminal block connection type / torque Power terminal block solid and stranded conductors Control terminal block connection type / torque Control terminal block solid and stranded conductors Coil connection type / torque Coil solid and standed conductors Main auxiliary contact connection type / torque Main auxiliary contact solid and stranded conductors OLR auxiliary contact connection type / torque OLR auxiliary contact solid and starnded conductors Vertical Pole and surface Box lug / 35 lb in (14 - 10); 40 lb in (8); 45 lb in (6 - 4) AWG 1x(14 - 2 AWG) 60/75°C AL or CU Screw / 24 - 32 lb - in 1x(18 - 2 AWG) 75°C CU Screw / 12 - 18 lb - in 1x(22 - 8 AWG) 75°C CU Screw / 7 - 10 lb in 2x(16 - 12 AWG) CU 60/75°C Screw / 7 - 10 lb in 2x(20 - 16), 2x(18 - 14) 75°C CU Screw / 7 - 10 lb in 2x(20 - 14 AWG) CU 60/75°C Short Circuit Current Rating: Fuses 10kA@600V (Class H or K); 100kA@600V (Class R or J) Certificates / Approvals: cULus UL rated Service Entrance Equipment 6 UL (file no. E185287) ISO 9001 certification 2.75 .25 3.50 2.88 1/4-20 x1/2" SCREW 5.57 3.50 10.93 2.88 3.50 3.06 3.50 1.68 1.81 26.13 24.27 25.00 2.13 ∅2.85 O.D. FLANGED CONDUIT OPENING .37 MOUNTING HOLES FOR 5/16" HARDWARE ∅1.375, ∅1.700, ∅2.000, ∅2.500 ECCENTRIC KNOCKOUT 5.02 ∅1.125, ∅1.385, ∅1.750, ∅2.000 ECCENTRIC KNOCKOUT (2 PLACES) 5.08 ALL DIMENSIONS IN INCHES OPTIONAL START BUTTON HAND-OFF-AUTO SELECTOR SWITCH TO SUPPLY LEGEND - FIELD WIRING L1 L2 L3 - TERMINAL ON COMPONENT - LOAD\CONTROL TERMINAL BLOCK POINT DISCONNECT LINE FUSES M OLR T1 1L1 2L1 1L2 2L2 T2 1L3 2L3 T3 AUXILIARY CONTACTS M MOTOR (13) (14) M CONTROL OPTION A (21) HAND OFF AUTO OLR A1 4 AUTO RUN 5 AUTO STOP 6 SS M OLR A2 (95) (96) HAND AUTO OLR A1 PB 4 SS AUTO RUN M M M A2 (95) (96) (13) 5 (98) AUXILIARY CONTACTS START (14) (97) REMOVE JUMPER FOR AUTO - STOP CONTROL OPTION B OFF (22) (21) (22) OLR AUTO STOP (97) 6 (98) REMOVE JUMPER FOR AUTO - STOP 7 The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. Siemens Industry, Inc. 3333 Old Milton Parkway Alpharetta, GA 30005 1-800-241-4453 [email protected] Subject to change without prior notice Order No. CPBR-CLS82-1114 Printed in USA All rights reserved © 2014, Siemens Industry, Inc. www.usa.siemens.com/controls