P rog ra m m ab le Te rmina ls NS Series NS, the HMI brand you can rely on » Proven Reliability » Best Match » Machine Management NS, the HMI brand you can rely on Machine Control at Your Fingertips. On-screen Machine Management. Expanding markets in emerging countries, short product cycles, and diversifying customer needs are just some of the factors that create drastic Let Your Machines Evolve changes for the production industry. To win in severe global market competition, you Best Match OMRON has provided even greater compatibility with have to continue to grasp industry changes OMRON PLCs and components to provide an advanced quickly, understand user needs accurately, and design process that lets you achieve appealing provide diverse forms of added value. machines. OMRON will help you handle ever-changing customer needs with the three keywords of the NS Series. Machine Management The NS Series transforms machine HMIs from simple operation panels and turns them into machine management tools. Proven Reliability The NS-series PTs have a proven track record that will take your machines to a higher level of reliability. 2 The Best Match Possible Machine Management Tool Proven Reliability The amount of work and cost of connecting to The machine designer can easily implement In the ten years since initial marketing, OMRON PLCs and components have been PLC troubleshooting, machine troubleshooting, OMRON has globally supplied numerous HMI greatly reduced. The results is an incredible settings for servo drives, temperature solutions with the highly reliable NS Series at range of features that is possible only when controllers, and other control components, over 200 sales and service centers around the unifying to one manufacturer. Connecting to status monitoring of connected devices, and world. the NJ-series Machine Automation Controller uploading/downloading of parameters. allows the machine designer to quickly achieve the features required by the user through support for improved troubleshooting and structured programming with structures and other new data types. 3 NS Series Lineup This powerful lineup showcases OMRON's unique value. Choose from 3 types to match your application and requirements. NS Series Standardd Models 15 Plentiful scree screen variations and diverse functions allow usee in a wide variety of applications. inches Color TFT NS15-TX 12.1 inches Color TFT NS1 NS12-TS 32,768 colors SVGA 800 x 600 pixels Screen memory size: 60 MB 32,768 colors XGA 1024 x 768 pixels Screen memory size: 60 MB USB Slave Ethernet USB Master RS-232C x 2 Controller Link USB Slave Video (RGB input only) Ethernet RGB output USB Master RS-232C x 2 Ladder Monitor RS-422A/485 Memory Card 10.4 inches Color TFT 8.4 NS10 NS10-T T NS10-TV inches Color TFT 32,768 colors VGA 640 x 480 pixels Screen memory size: 60 MB USB Slave Ethernet USB Master RS-232C x 2 5.7 NS8 TV NS8-TV V 32,768 colors VGA 640 x 480 pixels Screen memory size: 60 MB Controller Link Video Ladder Monitor Memory Card USB Slave Ethernet USB Master RS-232C x 2 5.7 Video Ladder Monitor Memory Card inches Color TFT inches Color High-Iuminance TFT NS5-TQ NS5 TQ 32,768 colors QVGA 320 x 240 pixels Screen memory size: 60 MB NS5 SQ NS5-SQ 32,768 colors QVGA 320 x 240 pixels Screen memory size: 60 MB USB Slave Ethernet RS-232C x 2 Memory Card USB Slave Ethernet RS-232C x 2 Memory Card NSH Series Hand-held d Models 5.7 A hand-held ve version of the NS5 is now available to perform operations op at the production site. inches nches Color TFT NSH5-SQR 32,768 colors QVGA 320 x 240 pixels inches ches Color TFT Hand-held PT Cable NSH5 SQG NSH5-SQG 32,768 colors QVGA 320 x 240 pixels USB Slave USB Slave RS-232C/422A Memory Card RS-232C/422A Memory Card Equipped with a red switch for an emergency stop input. Emergency stop (3 inputs) 4 5.7 Equipped with a gray switch for a stop input. Emergency stop (3 inputs) RS-232C RS-422A Controller Link Video Ladder Monitor Memory Card NSJ Series Integrated Controller oller Models 12.1 PT is unified with the t Controller into one package to greatly help standardize equipment and reduce size. inches Color TFT NSJ12-TS NSJ12 -G5D 10.4 inches Color TFT 32,768 colors SVGA 800 x 600 pixels Screen memory size: 60 MB USB Slave Ethernet USB Master RS-232C x 3 USB Slave Ethernet USB Master RS-232C x 3 NSJ8 TV NSJ8-TV V -M M3 3D -M3D 8.4 inches Color TFT NSJ8 TV NSJ8-TV V 32,768 colors VGA 640 x 480 pixels Screen memory size: 60 MB inches Color TFT NSJ5 SQ NSJ5-SQ Q USB Slave Ethernet USB Master RS-232C x 3 n n) (Controller Section) M3D I/O points: 640 t 20K stepss ty: Program capacity: 2K words Data Memory: 32K Controller Link Ladder Monitor Memory Card DeviceNet (Controller Section) I/O points: 1,280 P Program capacity: cappacitty: 60K stepss Data Memory: 128K words -M M3D/-G5 M3 -M3D/-G5D 5. 7 inches Color High-Iuminance TFT Controller Link Memory Card DeviceNet G5D G I points: I/O po 12 1280 2 0 280 P g Program cap p iity: pa paci y 60K steps ps capacity: D Memory: Data Memoryy: y 1128K words NSJ5 TQ NSJ5-TQ Q -M M3D/ M3 3D/-G G G5 -M3D/-G5D 32,768 colors QVGA 320 x 240 pixels Screen memory size: 60 MB 32,768 colors QVGA 320 x 240 pixels Screen memory size: 60 MB USB Slave Ethernet RS-232C x 3 -G G5D -G5D 32,768 colors VGA 640 x 480 pixels Screen memory size: 60 MB Controller Link Ladder Monitor Memory Card DeviceNet (Controller Section) I/O points: 640 Program cap capacity: paciity: 20K stepss ords Data Memory: 32K words 5. 7 Controller Link Ladder Monitor Memory Card DeviceNet (Controller Section) I/O points: 1,280 Program capacity: 60K steps Data Memory: 128K words inches Color TFT USB Slave Ethernet USB Master RS-232C x 3 -G5D 32,768 colors VGA 640 x 480 pixels Screen memory size: 60 MB Controller Link Ladder Monitor Memory Card DeviceNet (Controller Section) I/O points: 1,280 Program capacity: 60K steps Data Memory: 128K words 8.4 NSJ10-TV NSJ10 n n) (Controller Section) M3D I/O points: 640 y 20K steps y: Program capacity: 2K words Data Memory: 32K USB Slave Ethernet RS-232C x 3 Controller Link Memory Card DeviceNet G5D G I/O I/ /O points: 1280 /O 12280 2 P g Program capa pacit a tty: y 60K steps ps capacity: D Memory Data y: 12 128K words Memory: Software CX-Designer NS-Runtime Without screen creation and ladder programming, the CX-Designer Screen Design Software is so easy-to-use that anyone can master it. This software enables PLC communications from a personal computer by manipulating PT screens created using the CX-Designer. 5 A Revolutionary Best Ma The NS-series PTs provide revolutionary compatibility with the road-proven CS/CJ-series the new NJ-series Controllers to achieve even greater added value in user machines. The NJ-series Machine Automation Controllers Revolutionize Productivity You can create a flexible, high-speed, high-precision system based on the NJ-series Machine Automation Controllers. Use tags to access any memory areas, or troubleshoot machines and systems by using EtherNet/IP the NS-series PTs to make the most of the strengths of the NJ-series Controllers and to manage machines. EtherCAT 6 tch PLCs and The CS/CJ-series PLCs for the Reliability of a Proven Track Record Features are provided to easily connect to CS/CJ-series PLCs to take advantage of their proven track record. Many features that do not require screen creation or programming support everything from design through maintenance to take advantage of the compatibility of OMRON PLCs and PT and to serve as the face of your machines. 7 Power Support for All User From conceptual designs through commissioning, operation, and maintenance, the NS Design Reduced work For Machine Automation Controllers NJ-series P10 NJ Troubleshooter Integrated NS-series PT simulation P 11 Troubleshooter P 19 Plentiful Graphing Functions PLC Troubleshooter Machine Troubleshooter Best Match with OMRON Products Screen Data Security Functions P12 - P16 Smart Active Prarts (SAP) P 20 P 20 Device Data Transfer With EtherNet/IP Direct Connection to Temperature Controllers Face Plate Auto-Builder for NS NS Screen Templates Multi-language Support Multifunction Objects 8 P 17 P 18 CX-Designer Screen Design Software NEW P 21 P 22- P 25 Needs Series supports every user need. Startup/Operation Attractive, convenient features for easier operation Maintenance Features for reliability and complete maintenance P 26 260,000-color Video Display Comparison Analog RGB Output FTP Function User Security Functions LED backlight P 28 NEW P 26 Single Port Multi Access P 28 PLC Data Trace P 29 Operating log P 29 P 27 P 27 P 27 Ladder Monitor P 30- P 31 9 For Machine Automation Controllers NJ-series Use Integrated NS-series PT simulation or NJ troubleshoot by using the NS-series PTs to make the most of the strengths of the NJ-series Controllers and to manage machines. NJ Troubleshooter Controller Errors Standard Feature for NJ-series Controllers Errors are automatically detected and displayed on-screen along with corrective actions for the CPU Unit function modules, EtherCAT slaves, and CJ-series Units that are connected in the NJ-series Controller. Whenever an error might occur, you can recover normal operation quickly to reduce downtime without using user manuals or Support Software on a computer. NJ Controller User-defined Errors No Work Is Required to Create Alarm Screens. Frames for alarm screens are provided as standard features in the NS-series PTs. You do not need to create screens to complete alarm screens. Management of the meanings of alarms is unified on the Controller, so you do not have to register, add, or correct addresses on the NS-series PTs. Transfer Copy and Paste Excel Alarm Specifications Alarms displayed Sysmac Studio Alarm Registration and Programming Detection Conditions NJ Controller Unified Alarm Definitions No screen creation is required Integrated NS-series PT simulation Improved debugging efficiency "Integrated simulation" of Sysmac Studio enables offline debugging of the screen data for the NS-series PTs and sequence program for the NJ-series on the computer. * Sysmac Studio version 1.02 or higher (CX-Designer version 3.41 or higher) is required. Test screen of CX-Designer appears after synchronization of Sysmac Studio, and integrated simulation starts. Select Integrated Simulation. Select image data and host to simulate. 10 Design Startup/Operation Troubleshooter A Troubleshooter is provided for the connected OMRON Controller or PLC. This greatly reduces work requirements. Maintenance CS/CJ-series PLC Troubleshooter Constantly monitors PLC errors. NS-Run NS-Runtime untim timee Automatically detects PLC errors and displays the error details and recovery procedure on the screen. Even if a problem occurs, it can be resolved quickly without referring to the manuals. Hand-held PT Hand CS/CJ/CP-series PLC Features Note: A special template is required when using this function. The screen template is supplied with CX-Designer of version 2.1 or later. This function is a standard feature in the NSJ-series PTs. Network Machine Troubleshooter Easier Design of Machine Error Screens With this system, this frame is shared, and the error details in the pink frames are switched with an alarm or other item as the trigger. Text selection System Configuration Individual error screens that were previously made for each error can now be integrated into one. It is possible to switch only the error details (text and screen) without ladder programming in conjunction with the alarm bit. Image selection Specific Example Ordering Information in conjunction with an alarm bit (See note.) Alarm bit 10.01 ON (no paper) Specifications Alarm bit 10.02 ON (printing error) Note: Alarms, PLC/PT memory, and other items can be selected for the switching trigger. 11 Best Match with OMRON Products NS Series is the most suitable HMI for the system that comprises OMRON components. The advantage is the "compatibility (reducing programming and screen data creation work)" which will reduce the amount of designing work. No Screen Designing / No Programming NS PLC CPU Unit monitoring screen Device monitor PLC Data Trace Temperature Controllers PLC CPU Bus Units and Special I/O Units Remote I/O Terminal Inverter Temperature Controllers Servomotor Servo Driver SAP Library Troubleshooting Vision Sensor 260,000-color video input 12 Design The Temperature Controller's setting and monitor screens are completed in no time. Startup/Operation Smart Active Parts (SAP Library) Dramatically reduces the effort required to create ladder programming and screens. SAP Library, Temperature Controller Parts Maintenance More than 3,000 Library parts (Smart Active Parts) are available, which can directly access OMRON PLCs and components. The objects can just be pasted from the Smart Active Parts (SAP Library) Library to the screen; it is completely unnecessary to create screens and ladder programming. ACCESS CX-Designer Screen Design Software NS-Runtime ACCESS Example screens using support tool objects (Tool Function SAP Library) PLC CPU Unit monitoring screen Features Plenty of support tool objects (the Tool Function SAP Library) are available, which can be easily incorporate support tool functions in the NS-series PT. Just paste the support tool objects in the screen to check for errors and make settings, even without a computer. Hand-held PT Support tool objects can be incorporated to check for errors and make settings, even without a computer. Computer support tools Network NCF Unit setting screen Troubleshooter SAP for a Position Control Unit Troubleshooter SAP for Basic I/O Unit Specifications A Troubleshooter SAP Library is available to troubleshoot each Unit in the PLC. When an error occurs in a Unit, the Troubleshooter SAP Library provides an easy-to-understand explanation of the cause of the error as well as the countermeasures. To Ordering Information CPU Bus Unit and Special I/O Unit Troubleshooting Can Be Also Performed with the SAP Library. System Configuration From DeviceNet monitoring screen Note: The Troubleshooter SAP Library is included as a standard feature for the CX-One and CX-Designer. For details, refer to page 56. Successive development for Ethernet Units and MC Units is planned for the future. 13 Design EtherNet/IP Startup/Operation Simultaneous and parallel engineering The host applications can be designed using the tag names of the PLC and PT. Parallel development will shorten the design time. Support for data structures This special feature is made possible by combining an OMRON CJ2 PLC with an NS-series PT. The data structures that you define on the Programming Tool can be used on the CX-Designer simply by dragging and dropping them. EtherNet/IP NS Series CX-Designer Case 2 The screen graphics are created in advance, and then addresses are allocated and checked after the ladder program is completed. Programmable Terminal screens are created. Ladder program is created. PLC Programmable Terminal Ladder program is created. The addresses are set. PLC Programmable Terminal screens are created (graphics only). NS-Runtime Note: An EtherNet/IP connection is required. For CJ2 Series, CX-Designer version 3.2 or later, and NS system version 8.4 or later are required. For NJ5, CX-Designer version 3.3 or later, and NS system version 8.5 or later are required. For NJ3, CX-Designer version 3.4 or later, and NS system version 8.61 or later are required.Moreover, the multidimensional array is supported in the combination with NJ. FROM CJ2/NJ Maintenance Case 1 Previously, the PLC program was first created, and then the ladder program was referenced to create the screens. Addresses are allocated and the allocations are checked Programming Tool Definition of the "Motor" Symbol Programmable Terminal Drag & Drop Programmable Terminal Address Ladder program is created. Number_produced Undetermined By simply setting tag names, PLC and Programmable Terminal programming can be performed in parallel. CJ2/NJ Design time is shortene … Number_of_times Undetermined … TO Tag name Hand-held PT Addresses are determined while creating the ladder program. Specifications The screens are created. NS Series The screens are created with no need to pay attention to addresses. Features Tag access Design time is shortened. 1. Tag names are managed at the PLC with the CX-Programmer. A tag is a name given to an address. Tags are managed in the CJ2 CPU Unit, where they are defined as network symbols. The common user-defined tag names are used from Programmable Terminals and host applications to access memory in a CJ2 CPU Unit without knowing the physical address. Tag name Number_produced Address D100 Minimize side effect of address changes Network 2. For example, create screens with tag names without typing the physical address. It is possible to access memory with tags, so the PT and host application are not affected even if the address of data in the PLC is changed. Specific Example No change required. Host application 3. All devices will access with Common “Tag” Number_produced Tag name Number_produced Number_produced Data links Accessed by tag name. Address Number_produced System Configuration Host application 1. With the CX-Programmer, the address for the tag named “Number_produced” is changed from D100 to H200. Number_produced D100 Number_produced Accessed using a tag. Change Number_produced CJ2/NJ 14 No change required. CJ2/NJ 2. Applications and the PT are accessed using tags, and so changes do not need to be made at other devices. Even after the change, the number of items produced is acquired correctly from H200. Specifications NS Series H200 Ordering Information CJ2/NJ NS Series 15 Design EtherNet/IP Startup/Operation Simultaneous and parallel engineering The host applications can be designed using the tag names of the PLC and PT. Parallel development will shorten the design time. Support for data structures This special feature is made possible by combining an OMRON CJ2 PLC with an NS-series PT. The data structures that you define on the Programming Tool can be used on the CX-Designer simply by dragging and dropping them. EtherNet/IP NS Series CX-Designer Case 2 The screen graphics are created in advance, and then addresses are allocated and checked after the ladder program is completed. Programmable Terminal screens are created. Ladder program is created. PLC Programmable Terminal Ladder program is created. The addresses are set. PLC Programmable Terminal screens are created (graphics only). NS-Runtime Note: An EtherNet/IP connection is required. For CJ2 Series, CX-Designer version 3.2 or later, and NS system version 8.4 or later are required. For NJ5, CX-Designer version 3.3 or later, and NS system version 8.5 or later are required. For NJ3, CX-Designer version 3.4 or later, and NS system version 8.61 or later are required.Moreover, the multidimensional array is supported in the combination with NJ. FROM CJ2/NJ Maintenance Case 1 Previously, the PLC program was first created, and then the ladder program was referenced to create the screens. Addresses are allocated and the allocations are checked Programming Tool Definition of the "Motor" Symbol Programmable Terminal Drag & Drop Programmable Terminal Address Ladder program is created. Number_produced Undetermined By simply setting tag names, PLC and Programmable Terminal programming can be performed in parallel. CJ2/NJ Design time is shortene … Number_of_times Undetermined … TO Tag name Hand-held PT Addresses are determined while creating the ladder program. Specifications The screens are created. NS Series The screens are created with no need to pay attention to addresses. Features Tag access Design time is shortened. 1. Tag names are managed at the PLC with the CX-Programmer. A tag is a name given to an address. Tags are managed in the CJ2 CPU Unit, where they are defined as network symbols. The common user-defined tag names are used from Programmable Terminals and host applications to access memory in a CJ2 CPU Unit without knowing the physical address. Tag name Number_produced Address D100 Minimize side effect of address changes Network 2. For example, create screens with tag names without typing the physical address. It is possible to access memory with tags, so the PT and host application are not affected even if the address of data in the PLC is changed. Specific Example No change required. Host application 3. All devices will access with Common “Tag” Number_produced Tag name Number_produced Number_produced Data links Accessed by tag name. Address Number_produced System Configuration Host application 1. With the CX-Programmer, the address for the tag named “Number_produced” is changed from D100 to H200. Number_produced D100 Number_produced Accessed using a tag. Change Number_produced CJ2/NJ 14 No change required. CJ2/NJ 2. Applications and the PT are accessed using tags, and so changes do not need to be made at other devices. Even after the change, the number of items produced is acquired correctly from H200. Specifications NS Series H200 Ordering Information CJ2/NJ NS Series 15 Direct Connection to Temperature Controllers Connect OMRON Temperature Controllers directly to the NS-series PT. OMRON Temperature Controllers can be connected directly to the NS-series PT's RS-232C port. Data does not pass through the PLC, so ladder programming is not required. Also, there are plenty of objects in the SAP Library for Temperature Controllers, and Temperature Controller screens can be created easily just by pasting objects from the SAP Library to the screens. OMRON Temperature Controllers Note: An RS-422A Serial Adapter is needed to connect directly to a Temperature Controller. Refer to page 53 for a list of the Temperature Controllers that can be connected. A Conversion Unit is not required to connect to the RS-422A/485 serial interface of the NS15. OMRON Temperature Controllers CJ1W-CIF11 RS-422A Serial Adapter Face Plate Auto-Builder for NS Screens for Loop Controllers can be easily and automatically created. CX-Process Tool (Loop Controller Programming Software) Loop Controller program creation (function block method) CSV tag file output Significantly reduces the effort required to combine a Loop Controller with an NS-series PT. Easy automatic generation of faceplates, such as faceplates for PV monitoring and SV setting, as well as tuning screens, such as screens to set and autotune PID constants. A total of 17 function blocks are supported, with eleven function blocks, such as Ratio Setting and Motor Manipulators newly supported (version 3 of higher). CSV tag file for Loop Controller NS project file Comments are automatically entered for automatically assigned unit and scale settings when a project is generated (version 3 and higher). NS Series Face Plate Auto-Builder for NS Created screens are easily transferred to the NS by using a Memory Card or over the network. CX-Designer SYSMAC CS/CJ-series Loop Controller (NS screen creation software) Editing created data Creation of other required screens Note: Refer to the PLC-based Process Control Catalog (Cat. No. P051) and the Loop-control CPU Unit Catalog (Cat. No. R128) for details on Loop Controllers. 16 Design Support 42 languages and switch the language of the labels among up to 16 languages. Startup/Operation Multi-language Support Multi-language CSV data The labels' text attributes can also be reflected when importing. Maintenance When screen data is imported, text attributes can be applied to the specified labels and attributes such as the font and text color can be reflected to other languages labels. Unicode is supported and 42 Asian and European languages can be combined in screens. Also, it is possible to switch between up to 16 labels using the label switching function, so it is possible to support up to 16 languages in a single screen just by specifying the language to be displayed in each label. Import NS-Runtime NS Series Support for 42 International Languages Hand-held PT Thai Displays Also Supported Features Multi-language conversion has become much easier. The screen data in the source language is exported to a CSV file and sent to a translation agency by e-mail for translation. Later, the translated CSV file is just imported to easily provide multi-language support. Language A screen data Dual-language input in Excel by translation companies and local companies CSV Network NS project Language A Excel data Attachment CSV Dual-language screen data Language A and B Excel data Attachment System Configuration NS project CSV CSV or Unicode text Note: Windows XP (Service Pack3 or higher), Vista or 7 is required for multi-language support. English system menu (maintenance menu) Chinese French Specifications The system program of NS-series PTs supports Chinese and European languages. All eight languages are a standard feature, including Chinese (traditional and simplified), Spanish, Italian, German, and French, in addition to the previous Japanese and English. Along with maintenance menus, messages for communications errors, communications settings, and screen transfers can be displayed in any of eight languages. Maintenance can be performed in the desired language. The language can be easily set using the NS-series PT or screen data. Ordering Information Multi-language System Messages. Eight Languages Supported as Standard Feature Italian Multi-language messages for communications errors 17 Multiple functions Multifunction execution with one object Execute up to 32 functions with one Multifunction Object Multifunction Objects support Write Bit, Write Word, object control, and etc Multifunction Objects combine the functions of multiple objects into one object. Multiple functions can be executed by pressing one button without using troublesome macros. Setup is easy. For example, a setting can be made on-screen using the Support Software to turn ON a bit to start a machine, set a value, and then change the screen. Integration Easy On-screen Setup with Support Software! Execute multiple functions with one button. Example: The bit turns ON. Touch The word is set. The screen changes. Multifunction Objects support four useful functions Switches that do not immediately operate when touched can be easily made without ladder programming. Time the button is pressed. Time the button is not pressed. ON delay Turns ON when the button is pressed for at least a specified time. Touch ouch Button pressed Delay: 0.5 to 15 s Relay status Double-press ON! Turns ON when the button is pressed twice within the specified time. Touch ouch Touch Button pressed Acceptance time: 0.5 to 30 s Relay status Simultaneous pressing prohibited OFF delay ON! Does not turn ON when the button is pressed at the same time as another button. Turns OFF after a specified time lapses after the button is released. Touch ouch Button pressed Delay: 0.5 to 15 s Relay status 18 OFF! Design Startup/Operation Plentiful Graphing Functions Data Log Graph (Trend Graph) Up to 128 data can be collected in the cycle of 500ms. Logging data is stored as a CSV file in the Memory Card inserted in the NS-series PT. The log data files in the Memory Card appear as shown below when the read file button is pressed. Maintenance Logging data is stored as a CSV file in the Memory Card mounted in the NS-series PT. The data stored in the Memory Card can be read or deleted from the screen. NS-Runtime Read file button Suffixes are automatically added to file names set in the CX-Designer. Memory Card Automatically saved Logging data for each day (43,200 points) is saved in the Memory Card in CSV format. Hand-held PT A log can be saved automatically, without any programming, just by selecting the Save the data periodically Option in the Data Log Setting Window. LOG001.CSV 04/06/04 10:00 LOG002.CSV 04/06/05 10:00 LOG003.CSV 04/06/06 10:00 LOG004.CSV 04/06/07 10:00 LOG005.CSV 04/06/08 10:00 LOG006.CSV 04/06/09 10:00 LOG007.CSV 04/06/10 10:00 It is possible to make a one-week log by automatically saving the data seven times. Features Line Graph Function (1) Graphs can be superimposed. Network The data logged by the PLC can be displayed in overlapping graphs, so a device's operation can be compared for evaluation and analysis. In addition, up to 1,000 words of consecutive data can be displayed as a line graph, data can be displayed together, and any region can be magnified. System Configuration (2) The display can be magnified. Ordering Information Continuous Line Function Y PLC (X2, Y2) D0000 X1 D0001 Y1 D0002 X2 Specifications Any position from the host (PLC) can be plotted as a graph. A graph can be plotted in any position by specifying the X and Y coordinates of the vertices. Also, the graph can be moved on the screen by specifying the movements from the PLC. (X3, Y3) (X1, Y1) Y2 X3 Y3 X Information in the PLC's format can be plotted moment-by-moment. 19 Screen Data Security Functions Security password Protect important screen data with a password. A password between 4 and 64 characters long can be set. The download/upload will start if the user inputs the password that was set when the screen was designed. (Password input will be disabled if the wrong password is input 3 times in a row.) If password protection is set in the data transfer security settings when the screen data is designed, a password must be entered to download or upload the screen data, so important screen data can be protected. Download Upload Download Upload If a password has been set, the password is required to transfer screen data (download or upload) with the Memory Card. Device Data Transfer Multi-vendor Support Easy Data Exchange between the PLC and Components For example, temperature controller alarm values can be transferred to the DM Area of the PLC's CPU Unit. No communications programming or macros are required. Multi-vendor Support Temperature controller NS PLC SAP data can also be exchanged. SAP data can be exchanged by checking the address of the SAP data in the dialog box of the SAP object pasted in the CX-Designer and specifying that address as the transfer source address. Note 1: EtherNet/IP tags are not supported. Note 2: CX-Designer version 3.1 or higher is required. NS system version 8.2 or higher is required. 20 DM0300 DM0302 DM0304 80 100 30 Modbus device PLC from other company C10004 C10005 C10006 80 Alarm value 1 100 Alarm upper limit value 1 30 Alarm lower limit value 1 Temperature controller Easy Settings Easier Operation when Combining SAP Library Objects 80 100 30 Easy Settings Devices from multiple vendors are supported. Data can be easily exchanged with PLCs from other companies and Modbus devices. To make the settings, simply specify the device and addresses of the transfer source and transfer destination in the CX-Designer. Settings can be made using the same procedure as for setting the addresses for normal components. C10004 C10005 C10006 DM0300 DM0302 DM0304 NS 80 100 30 PLC CX-Designer Select Device Data Transfer Setting from the PT Menu. Make the settings simply by specifying the addresses of the transfer source and transfer destination as well as the number of data items. Design NEW Easy Reading from Palette Startup/Operation NS Screen Templates The CX-Designer of version 3.5 or higher provides the palette to display objects and templates (scheduled for auto update in August 2012). Refer to the next page for details of the palette. Even Simpler Maintenance Templates can be read into the screen by just dragging and dropping thumbnails displayed on the palette. Drag & Drop The template consisting of multiple screens allows multiple screens to be read by dragging and dropping it once. NS-Runtime The Address Setting Dialog Box that is displayed to read templates is useful for changing addresses all at once. Palette Address Setting Dialog Box The refined templates enable you to use the NS Series with the screens that have a sense of unity in design. Hand-held PT Even More Beautiful POP (default) Features Three different types of templates besides default screens are provided. The design can be changed easily with "Theme Name" that is displayed when dragging and dropping. CLEAN METAL NATURAL Network System Configuration “Cool” Objects Aluminum Backgrounds, buttons, labels, message boxes, and other objects are also provided for various themes. Metal Ordering Information Game Lighting Specifications Dot Metalplate Water 21 Screen Designer for NS Series, CX-Designer User-friendly Screen Creation Without screen creation and ladder programming, the CX-Designer Screen Design Software is so easy-to-use that anyone can master it. Quickly create the required screen by dragging and dropping objects. OMRON’ s unified development environment lets you drastically reduce the work required to create screens. Note: The same type of Project Workspace and Output Window as in the CX-Programmer are provided for the user interface. All addresses and comments can be managed using a single Symbol Table. Shows a list of addresses, names, and comments used in project screen data. Addresses, names, and I/O comments for the CX-Programmer can also be imported. Improved Icons and Help The project Workspace enables the user to look through the entire project. Screens you want to edit can be opened right away. Perform screen management, such as copying or deleting screens, by simply right-clicking. Reusing screens from other projects is easy with the CX-Designer. Settings for alarms, data logs, communications, and other functions can be easily accessed. 22 Objects and templates can be selected easily from the palette. NEW Easy-to-use, well-designed, and super-beautiful objects and templates can be read into the screen by dragging and dropping. Templates can be chosen from four different designs. Drastically reduce the number of clicks in the project. The Output Window shows search results. Just click on the object once to display or change properties. Multiple objects can be selected to display and change shared properties all at once. In addition to addresses and I/O comments used in screen data, labels can also be used as search strings and the results can be displayed. Design NEW Startup/Operation Palette Switches, lamps, and templates are registered in the palette. Just drag and drop them on the new or existing screen to add. Note. CX-Designer version 3.5 or higher is required. Maintenance Import The Import button allows new objects and templates to be added to the palette. The palette appears on the right side of the screen when starting the CX-Designer. NS-Runtime Library and Template tabs at the bottom left of the palette Palette Library Parts list of switches and lamps is displayed. Hand-held PT Template Templates are displayed in thumbnailed form. Library Color Setting Features Switches and lamps are registered in the library. Select a switch, lamp, or other object from the pull-down menu. You can register switches you created or other objects you often use in "User-defined". Display colors of objects registered in the library can be changed easily by selecting colors from pull-down menus. Network Change display color to blue. A template consists of multiple screens. Multiple screens are pasted on the screen by dragging and dropping a thumbnail on the screen. Ordering Information Templates include design templates and device templates. System Configuration Template •Design Template Design templates are the screen templates designed professionally. Addresses can be changed with "Address Setting Dialog Box". As well as SAP (Smart Active Parts), addresses on the screen are automatically updated by changing unit number of Temperature Controller or Special I/O Unit with "Unit No Dialog Box". Specifications •Device Template Drag & Drop 23 Reading Another Project's Screens and Objects Resources from another project can be easily reused by just selecting the screen or objects that you want to read and dragging and dropping it, so screens can be created intuitively. Example screen 1 Select the screen that you want to read, drag it to the destination, and drop it. Example screen 2 Select the part that you want to read, drag it to the destination, and drop it. Project B Project B Project A Project A Drag & Drop Drag & Drop Reading CAD Files It is possible to import DXF files by dragging and dropping them. The files are read as a diagram, and so less capacity is used than with images. It is also easy to customize the diagram by changing the shape or color. CX-One Version 2.0 on computer The screen data and ladder program can be checked simultaneously in the computer. The CX-Designer and CX-Programmer interconnects the test functions in the computer through the CX-Simulator. The screens and ladder program checks are performed simultaneously, which significantly increases debugging efficiency. The CX-Programmer also has a new button for integrated simulation. And, work efficiency is further improved with the ability to keep required work screens pinned on front and to zoom in or out as desired. Ladder Program Prog el Touch Panel Interactive Ladder Program Window Touch Panel Screen Interactive 24 Design CX-Programmer's symbol table Maintenance The symbol table created in the CX-Programmer during ladder programming can be read into the CX-Designer by dragging and dropping, so it isn't necessary to manually data such as input addresses and I/O comments. Tags (i.e., network symbols) can also be read into the CX-Designer. Startup/Operation Reading the Symbol Table Note: Version 8.0 or higher of the CX-Programmer support tags (i.e., network symbols). CX-Designer's symbol table NS-Runtime Drag & Drop The CX-Programmer's symbol table can be dragged and dropped! Hand-held PT Example of Reading the Symbol Table The symbol table read from the CX-Programmer can be directly dragged and dropped to the touch switch and lamp. Example of Easy Address Allocation (2) Check the comment then drag-and-drop the symbol from the symbol table to the property list. Features (1) Create a switch on the screen. Drag & Drop Network (3) Allocations for buttons and lamps can also be checked on the screen using comments imported from the CX-Programmer. System Configuration Example of Reading I/O Comments Ordering Information If Use I/O comment is selected in advance for the Use symbol text as label, the I/O comments are automatically used as labels when addresses are dragged and dropped from the symbol table. (If Use symbol names is selected, the symbol names are used as the labels.) Drag & Drop Specifications The I/O comment is used as the label. 25 260,000-color Video Display Equipment and workpiece movements can also be displayed in beautiful video NS-CA001 Video Input Unit Four video inputs or CCD cameras can be connected and up to four images can be displayed simultaneously if the image size is 320x240 pixels. The NS-CA001 cannot be used with the NS5 or the NS15. NS-CA002 RGB/Video Input Unit There is an analog RGB input terminal in addition to the two video input terminals. Either of the video signals or the analog RGB signal can be displayed on the NS-series PT. The NS-CA002 cannot be used with the NS5. Note: Video input cannot be used with the NS15. Only RGB input can be used. Also Compatible with OMRON Vision Sensors. Analog RGB Output The NS screen is seen by another monitor. The NS15 screen (XGA) can be displayed on an on-site display that has RGB inputs. Note: Only NS15 26 Console Camera RGB Console Camera Design Startup/Operation FTP Function You can partially replace text and pictures from your computer. Maintenance FTP (File Transfer Protocol) has been added! Texts, lists, and recipes can be replaced with the put/get command from your computer! You can even replace BMP files from your computer easily. Screens, bitmaps, text, recipe data NS-Runtime Hand-held PT Low User Security Functions Level 1 Level 2 Level 3 High Level 4 Level 5 Network Each operator can be given one of 5 password levels using the User Security (level authentication) function. A password level can be set for each object, so various objects can be made inoperable or hidden based on the operator's access level. Features Operator access rights and the operating format can be set to one of five password levels. Operator passwords are managed in 5 levels. Passwords can be up to 16 characters long and the access rights increase as the level number increases. The operator cannot manipulate objects with a password level (authentication level) higher than the operator's login level. System Configuration NS with LED backlight Conventional three-level adjustment * LotNo.15Z0 or later of NS5 color-type models, LotNo.28X1 or later of NS8 models, LotNo.11Y1 or later of NS10 models, LotNo.14Z1 or later of NS12 models, LotNo.31114K or later of NS15 models. New 32-level adjustment Specifications LED backlight allows backlight brightness adjustment of up to 32 levels. The brightness can be adjusted from the operation screens, and the RUN indicator changes its luminance according to the settings of the backlight brightness; it is favorable for ship and vessel applications. Ordering Information NS5 color-type models (SQ/TQ models), NS8 models, NS10 models, NS12 models, NS15 models with LED backlight are newly released. * 27 Comparison NEW The on-site NS screen can be compared with the computer screen. Same Different Added Deleted The comparison function of the CX-Designer enables the following comparison. CX-Designer project Project in the computer CX-Designer project NS project Same in screen Different in screen Screen added Screen deleted PT Transfer Compare Comparison Comparison result Single Port Multi Access (SPMA) Note: Communications across network layers can be performed. Keep connected. CX-Programmer Serial connection (1: N NT Link only) Ethernet Controller Link USB or Ethernet Transfer ladder program data to the PLC via the PT. Perform online editing via the PT. Computer (Serial) PLC (Ethernet or Controller Link) PLC Ladder program Computer (Serial/USB) NS-series PT (Ethernet) PLC (Ethernet or Controller Link) PLC Transfer screen data via the PLC. The ladder program can be transferred. NS Ladder program Keep connected. CX-Designer NS-series PT Ethernet or Controller Link The ladder program can be transferred. USB/Serial or Ethernet (See note.) PLC NS Serial Screen data Screen data Ethernet or Controller Link Note: USB connection is supported only for CJ2 PLCs. Using a USB relay cable greatly improves debugging at equipment startup. Use a USB relay cable to enable performing maintenance from in front of the control panel. Screen data CX-Programmer CX-Designer USB relay cable (IP65 oil-proof type) (sold separately: NS-USBEXT-1M) NS Easy Automatic Connection A search is automatically made for the PLCs connected to the PT and the results are displayed using the automatic online connection function in the CX-Programmer. Just select a PLC from the list to connect. This function is also supported for PLCs over network layers. Commercially available USB cable CX-Programmer 28 Note 1: SPMA can be used in CS/CJ-series PLCs with lot number 030201 or later. Note 2: SPMA via a PLC is not supported when a CP-series PLC is connected. (SPMA via an NS-series PT is supported with a CP-series PLC.) Note 3: CX-Programmer version 8.2 and higher support automatic online connection via the PT. NS system version 8.2 or higher is required. Automatic search PLCs registered to the PT are automatically searched for. Make the connection simply by selecting from the PLC list. Design Startup/Operation PLC Data Trace The PLC data trace function can be used without a computer. Maintenance The PLC Data Trace function is built into the PT in addition to the Ladder Monitor and Device Monitor. A bit's status and operation can be viewed in a time chart just by setting the desired PLC bit's address in the PT. It is also now possible to display word data, save data in CSV files, and save time chart screens in BMP files. NS-Runtime Note 1: There are differences between this Data Trace function and the CX-Programmer's Data Trace function. Refer to the NS-series Programmable Terminal Programming Manual (Cat. No. V073) for details. Note 2: The PLC data trace function cannot be used with the 5.7-inch model. Note 3: The PLC data trace function is not supported for connection with a CP1E PLC. Data Trace CS/CJ/CP-series PLC Hand-held PT Operating log What Was Touched When? can be recorded. Features Functionality has been improved with the addition of a log to record operators’ use of the panels. It is now possible to record and display the time, date, and operation details for buttons (i.e., hardware switches) pressed on the control panel in addition to operations on the touch panel. The operation log can be saved in a CSV file on a Memory Card mounted in the NS-series PT. Network Multiple operation log files can be saved on a Memory Card with date and time data. System Configuration Memory Card Operat_080520_ 173000.csv Ordering Information Operat_080521_ 173000.csv Operat_080522_ 173000.csv Switch directly from m the user screen to the log operationn display screen. A comment of up to 32 characters can be set and displayed for each operation to provide easy-to-understand information about what type of operation was performed. The files can be opened in Excel. Specifications For example, with a control panel comprised of the NS-series PT, hardware switches, and an emergency stop button, you can even record and display operation of the emergency stop button. 29 Ladder Monitor The ladder program can be monitored without a computer. Ladder programs with I/O comments can be monitored on the PT's screen and the ladder program can also be edited with the Programming Console function. Operation screen CS/CJ/CP-series PLC Also meets the requirements of users who need to display devices onsite Switch Box Function Device Monitor Function Switch Box Function The operator can check the PLC status by displaying just the I/O comments and status. Device Monitor Function Displays the device's contents, allowing settings to be input and checked and making startup operations more efficient. so no extra work to show I/O comments Select Read I/O Comment Reading from the Menu. The I/O comments are displayed. Read I/O comments directly from the PLC. I/O comments do not have to be stored in a Memory Card. Easy checking the alarm bit and shortens searching time. ALARM When an alarm occurs, touch the message to automatically search for the alarm bit (output bit) for the alarm. This enables you to quickly check the alarm address and investigate why the bit turned ON. Found it! 30 Design Startup/Operation “Find Back”, “Find Next”, useful Function Supported by the NS-series. Reduced Time to Investigate Which Output or Input Is Causing the Problem. Function Operationn with NS-series PT. CX-Programmer Find the address at specified by the cursor. Next “N” Key uble-cliick Double-click Return to the previous search position. Maintenance Find the output from the input bit or find the input bit from the output at the cursor. “Space” Key “B” Key Backk NS-Runtime 1.Why is this output not turning ON? 2.Is this input the cause? What output corresponds to this input? 4.Which of these two inputs is the cause? Let’s look at CIO 21.00 first. 3.Why is this output not turning ON? Hand-held PT 5.There’s no problem with input CIO 21.00. Let’s go back to the previous program section. Features 6.So is it input CIO 21.01 after all? Back Yes, the problem is here! Locations that have been force-set are displayed in pink and can be checked at a glance. 2. Select the address by touching the panel. 1.Select the input bit for which the output will be forced ON. Network Force-setting and force-resetting are possible 3. Select the Forced Set Option and then press the Update Button. Change System Configuration 4. Forced ON Minor changes in values of timers or counters can be made without Support Software. Ordering Information Check and Change I/O While You View the Ladder Diagram on the I/O Monitor Display and change the present value by specifying the address. It is also possible to force-set/reset bits with the I/O monitor. Specifications Make the selection with the I/O monitor by touching the screen. Changing the present value of the address selected with the Change Value Button Note: The Ladder Monitor function is not supported by the 5.7-inch models. 31 NS-Runtime NS-NSRCL (NS-Runtime) Achieve machine/line monitoring and data logging on your office computer. Machine Viewer Displaying Maintenance Information (PDF File) Monitoring Device Alarms Machine monitoring in an office environment. There is no need to create complex host applications. Moreover, when an alarm occurs, a PDF file can be displayed as maintenance information. NS Series screens can be reused on the computer, and screens can be also newly created independently of touch panels at the production site. To Maintenance screen Ethernet Wide Screen MAX 3840pixel Computer output can be displayed on another wide-screen monitor. XGA (1,024 x 768 dots) and up to a a maximum screen size of 3,840 x 2,400 is supported. Alarms occurring in devices or the line can be monitored. MAX 2400pixel Monitor output Note: The resolution that can be displayed depends on the computer. An input function for displaying the computer screen is required at the display monitor. Data Logger Log large amounts of data using a personal computer. Data can be logged through background processing, with up to 160,000 points stored in one file. The logged data is stored in CSV format, and data can be displayed on data log graphs. CSV format Stored Data Example: 160,000 Points Data can be logged for approximately 7.4 days, assuming data is logged every two seconds for 12 hours a day. By using automatic file saving, data logging can be continued even longer than 7.4 days. 32 Design Startup/Operation Recipe Handling Maintenance NS-Runtime Checking machine data or switching processes from a host computer is easy. Parameter groups in the PLC can be transferred together to a computer, and the transferred data can be checked and edited in CSV format, e.g., using Excel. The edited data can then be transferred together back to the PLC. CSV format Hand-held PT Recipe data Easy Installation NS-Runtime Screen Data Features To get started, just install the NS-Runtime in the computer and place the screen data in the applicable folder. NS/NSJ-series screens and NS-Runtime screens can all be managed using one single tool. Note: The NS-Runtime will operate in a computer environment even if the CX-Designer installed is not installed. The hardware key (USB dongle) that is supplied with the NS-Runtime is required for operation. Application Startup Function Network To PLC Screen designer: CX-Designer (CX-One) NS-Runtime System Configuration User applications can be started from NS-Runtime. Applications can be started simply by pressing buttons on the screen. Started ted Ordering Information For example, to start an application by pressing a button… Use the EXEC( ) macro. Example: EXEC("C:ProgramFiles\Micros..\EXCEL.EXEC:\..\ TEST2.xls…..); Note: As much as possible, keep applications closed that are not required for operation. User application on Specifications Note 1: If the screen data is converted for the NS Series, NS-Series PT system versions must be 8.1 or earlier. The screen data of system version 8.2 can not be converted for the NS-Runtime. Note 2: Do not use this product for 24-hour operation in an FA environment. OMRON shall not be responsible if the computer or application does not operate properly due to noise or other causes. OMRON shall not be responsible for any problems that may be caused by any applications other than OMRON products. 33 NSH5 Series A hand-held version of the NS5 is now available to perform operations at the production site. The NS-series PT's have a complete set of functions that can be used at the production site, such as the SAP Library, multi-language support, and Programming Console functions. Function Switches Use the ten functions switches. F1, F2, F6, F7: Wired outputs F3 to F5, F8 to F10: Communications outputs Memory Card Interface and USB Slave Connector. Easily transfer screens or save logs at high speed using a USB connection. Emergency Stop Switch. 3PST-NC Structure DPST-NC: Increase safety (wired outputs). SPST-NC: Input to internal NSH5 memory, output to a lamp for emergency stop switch operation, or output via communications, e.g., to a PLC. Water Resistance to IP65 The water-resistant structure is equivalent to IP65 on all surfaces. The PT may not be suitable for use in environments with long-term water exposure. 3-Position Enable Switch Increased safety with DPST-NO structure (wired outputs). Precautions for Emergency Stop Switches When using a hand-held NSH5 that will be installed and removed from a control panel or Removable Box, always use the specified Stop Switch (Gray/NSH5-SQG10B-V2) to conform to Safety Standards (EN 60204-1). Options Removable Box A separate external circuit is not required because the Removable Box has been configured so that the emergency stop switch line will not turn OFF (i.e., so that the emergency stop circuit will operate) even when the NSH5 is removed. Visor Use when the NSH5 is in direct sunlight. Mounting Bracket Use to attach the NSH5 to a control panel. 34 PT and Cable Sold Separately Select the Cable according to the application (RS-232C/RS-422A). Connector-loose wires, UL connector, 3 m or 10 m. Programmable Terminals NS Series Even Simpler Equipment Operation with Outstanding Synergy. 5.7 inches 10.4 inches 15 inches 12.1 inches 8.4 inches Color TFT Color TFT Color TFT Color TFT Color TFT STN monochrome Features • 5.7 to 12.1 inch sizes are available. • A hand-held version of the NS5 is now available to perform operations at the production site. The NS-series PT's have a complete set of functions that can be used at the production site. • The Smart Active Parts(SAP Library) makes it easy to connect to OMRON PLCs and components, OMRON provides a development environment that requires with no programming and no screen designing. • When an error occurs in a Unit in the OMRON PLCs, the Troubleshooter SAP Library provides an easy-tounderstand explanation of the cause of the error as well as the countermeasures. • Ladder Monitor come as a Standard Feature. The ladder program can be monitored onsite without a laptop! Ladder monitor lets you monitor PLC program status, search for addresses or instructions, monitor multiple I/O points, and much more. • Provides the FA integrated tool package "CX-One" for a Screen Design Software Integrated Simulation come as a Standard Feature. The integrated simulation function simulates ladder programs and screen data simultaneously even without the actual hardware. • Screens support 42 languages and the Support Software supports eight. System messages can be displayed in eight languages. • Single Port Multi Access (SPMA) come as a Standard Feature. The ladder program and screen data can be transferred from a single port! • Connectable PLCs and devices appear one after another. Has become connectable with the PLCs of Mitsubishi Electric Corporation and the Inverters of OMRON Corporation. Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products. Windows is registered trademarks of Microsoft Corporation in the USA and other countries. EtherCAT is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. Other company names and product names in this document are the trademarks or registered trademarks of their respective companies. 1 NS Series Network Provides serial NT Link communications supporting both 1:1 and 1:N connections. The NT Link has more efficient communications than Host Link and its capabilities are especially apparent in applications with multiple PTs connect to the PLC. The NS-series PTs can also support communications with multiple PLCs and multiple NS-series PTs through Controller Link and Ethernet connections, so the network can be configured freely to match the requirements and scale of the application. In addition, using the NS-Runtime makes it possible to monitor machine status and log data from the host. Software for Machine Monitoring and Data Logging [Example NS-series Network Configuration] 1 EtherNet/IP (Tag access) 4 (sold separately) Personal computer EtherNet/IP, Ethernet CS/CJ-series PLC 3 Controller Link NS-series PT 2 Serial connection 5 Connections across network levels NS-series PT CS/CJ-series PLC NS-series PT NS-series PT 2 Serial CS/CJ-series PLC CS/CJ-series PLC connection Configuration of CJ2 series, NJ series and NX series 1 EtherNet/IP Connection (Tag accesses) If an Ethernet-compatible NS-series PT is used, the PT can connect to a Controller with built-in EtherNet/IP and an Option Unit is not needed to connect at the PT. NS-series PT Personal computer Controller 2 Controller NS-series PT Controller NS Series Configuration of CS series, CJ series and CP series 2 Serial connection 1:1 NT Link or Host Link NS:PLC = 1:1 NS:PLC = 1:2 Connecting with the PLC through port A or port B NS-series PT NS-series PT PLC PLC PLC 1:N NT Link NS:PLC ratio = 8:1 max. Up to 8 NS-series PTs can be connected to each of the PLC's RS-232C/RS-422A ports. NS-series PT NS-series PT NS-series PT PLC NS-AL002 Converter (Converts between RS-232C and RS-422A.) 3 Controller Link Connection The PT can be connected to an OMRON Controller Link network by mounting a Controller Link Interface Unit. NS-CLK21 NS Series PT If a Controller Link connection is used, data links can be set between PLCs and multiple PLCs can be monitored/set from the NS-series PT's screen. PLC PLC PLC Baud rate 2 Mbps (500 m max.) 1 Mbps (800 m max.) 500 kbps (1 km max.) Max. number of nodes: 32 nodes 4 EtherNet/IP or Ethernet Connection If an Ethernet-compatible NS-series PT is used, the PT can connect to a PLC with an Ethernet Unit and an Option Unit is not needed to connect at the PT. NS Series PT Personal computer PLC PLC NS Series PT PLC 5 Connections Over Network Levels The NS-series PTs can connect to a variety of devices in the network, through as many as 3 network levels. For example, if SAP (Smart Active Parts) are being used, an NS-series PT connected by Ethernet can be used to monitor the information in a PLC connected through Controller Link as well as the information in the DeviceNet Slaves connected to that PLC. NS Series PT NS Series PT Ethernet PLC Seamless and Program-less Seamless and Program-less Controller Link PLC PLC DeviceNet 3 NS Series System Configuration NS5/NS8/NS10/NS12/NS15 OMRON Memory Card Memory Card Interface Ethernet port USB Slave RS-422A Conversion Unit CJ1W-CIF11 NS-AL002 Note: A Conversion Unit is not required to connect to the RS-422A/485 serial interface of the NS15. USB RS-232C RS-232C Master port port OMRON PLC PT-to-PLC Connecting Cable XW2Z-200T (Length: 2 m) XW2Z-500T (Length: 5 m) RS-232C Bar Code Reader Recommended: OMRON V520-RH21-6 Screen transfer cable XW2Z-S002 (Length: 2 m) Screen transfer cable XW2Z-S002 (Length: 2 m) RS-232C USB Serial Conversion Cable CS1W-CIF31 USB Personal computer Memory link connection Micro-computer board, personal computer, etc. CompoWay/F connection Temperature Controller Modbus (MEMOBUS)-RTU connection RS-422A OMRON PLC Inverter Standard USB cable Commercially available. Standard USB cable Commercially available. Standard USB cable Commercially available. PictBridge PictBridge-compatible printer USB Personal computer Wireless WE70 USB WE70 Ethernet OMRON PLC Ethernet OMRON PLC EtherNet / IP OMRON Controller Ethernet Personal computer 4 NS Series Expansion Bus Interface Any one of the following Units can be mounted to the expansion bus interface. Controller Link Interface Unit NS-CLK21 Video Input Unit NS-CA001 RGB/Video Input Unit NS-CA002 Expansion bus interface Controller Link PLC NTSC/PAL Vision Sensor NTSC/PAL RGB output Note: Video Input Units and RGB Video Input Units cannot be used with some models. Personal computer Multi-vendor Computer Link Unit Mitsubishi A-series PLC Function Extension Board or Mitsubishi FX-series PLC Communications Adapter Mitsubishi FX-series PLC Serial Communications Unit Mitsubishi QnA-series PLC Serial Communications Unit RS-232C port RS-232C port Mitsubishi Q-series PLC RS-232C Computer Link Module Yokogawa’s FA-M3(R) Series SIMATIC S7 HMI Adapter Siemens S7-300-series PLC RS-422A Conversion Unit CJ1W-CIF11 NS-AL002 Note: A Conversion Unit is not required to connect to the RS-422A/485 serial interface of the NS15. RS-422A/485 (See note.) Serial Communications Module Screen transfer cable XW2Z-S002 (Length: 2 m) Yaskawa MP-series PLC Rockwell (Allen-Bradley) SLC500/Micrologix/ControlLogix/ CompactLogix/PLC-5-series PLC Modbus device (RTU mode) Computer Link Unit Mitsubishi A-series PLC Function Extension Board or Mitsubishi FX-series PLC Communications Adapter Mitsubishi FX-series PLC Serial Communications Unit Mitsubishi QnA-series PLC Serial Communications Unit Mitsubishi Q-series PLC Computer Link Module Yokogawa’s FA-M3(R) Series Serial Communications Module Yaskawa MP-series PLC Rockwell (Allen-Bradley) PLC-5-series PLC Modbus device (RTU mode) Note: Whether an RS-422A or RS-485 connection is supported depends on the device that you are connecting to. For details, refer to the Connectable Devices page or NS-Series Programmable Terminals HOST CONNECTION MANUAL Multivendor Connection (Cat.V092). 5 NS Series NSH5 Hand-held PT USB Commercially available USB cable. USB Slave Memory Card interface OMRON Memory Card NSH5 PT RS-232C cable RS-422A cable RS-232C cable UL-listed Cables RS-422A cable RS-232C Connecting Cable for the NSH5 NSH5-232CW-3M (Length: 3 m) RS-232C PLC RS-422A PLC RS-232C PLC RS-232C Connecting Cable for the NSH5 NSH5-232CW-10M (Length: 10 m) RS-422A Connecting Cable for the NSH5 NSH5-422CW-10M (Length: 10 m) RS-232C Connecting Cable for the NSH5 NSH5-232UL-3M (Length: 3 m) RS-232C Connecting Cable for the NSH5 NSH5-232UL-10M (Length: 10 m) RS-422A Connecting Cable for the NSH5 NSH5-422UL-10M (Length: 10 m) PLC RS-422A USB Commercially available USB cable. USB Slave Personal computer Memory Card interface OMRON Memory Card NSH5 PT Personal computer Removable Box Connected RS-232C cable Removable Box RS-232C Connecting Cable for the NSH5 NSH5-232CN-3M (Length: 3 m) RS-422A PLC RS-232C Connecting Cable for the NSH5 NSH5-232CN-10M (Length: 10 m) System Configuration (Removable Box Connected) Up to eight NSH5s can be connected at a time. NSH5 (See note.) PLC RS-232C connection (Cable length: 3 or 10 m) Removable Box Control panel RS-422A connection (Total cable length: 500 m max.) Up to 15 Removable Boxes can be connected. Note: Before removing the NSH5 from the Removable Box, be sure to first turn OFF the power supply key on the Removable Box. 6 NS Series Ordering Information International Standards • The standards are availabled as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives. • Contact your OMRON representative for further details and applicable conditions for these standards. Programmable Terminals Product name Specifications Effective display area Number of dots Ethernet No 5.7-inch *2 TFT color LED backlight Yes 320 × 240 dots NS5-V2 *1 5.7-inch *2 High-luminance TFT color LED backlight 8.4-inch *2 TFT LED backlight NS8-V2 10.4-inch *2 TFT LED backlight NS10-V2 12.1-inch *2 TFT LED backlight NS12-V2 15-inch TFT NS15-V2 NSH5-V2 *1 Hand-held 5.7-inch TFT No Yes No 640 × 480 dots Yes No 640 × 480 dots Yes No 800 × 600 dots Yes 1,024 × 768 dots 320 × 240 dots Yes No Model Case color Ivory NS5-SQ10-V2 Black NS5-SQ10B-V2 Ivory NS5-SQ11-V2 Black NS5-SQ11B-V2 Ivory NS5-TQ10-V2 Black NS5-TQ10B-V2 Ivory NS5-TQ11-V2 Black NS5-TQ11B-V2 Ivory NS8-TV00-V2 Black NS8-TV00B-V2 Ivory NS8-TV01-V2 Black NS8-TV01B-V2 Ivory NS10-TV00-V2 Black NS10-TV00B-V2 Ivory NS10-TV01-V2 Black NS10-TV01B-V2 Ivory NS12-TS00-V2 Black NS12-TS00B-V2 Ivory NS12-TS01-V2 Black NS12-TS01B-V2 Silver NS15-TX01S-V2 Black NS15-TX01B-V2 Black (Emergency stop button: Red) NSH5-SQR10B-V2 Black (Stop button: Gray) NSH5-SQG10B-V2 Standards UC1, CE, N, L, UL Type4 UC1, CE, N, L UC1, CE, N, L, UL Type4 UC, CE *1. As of July 2008, the image memory has been increased to 60 MB. *2. Lot No. 15Z0 or later of NS5 color-type models, Lot No. 28X1 or later of NS8 models, Lot No. 11Y1 or later of NS10 models, Lot No. 14Z1 or later of NS12 models, LotNo.31114K or later of NS15 models. NS-Runtime Product name Specifications Media 1license NS-Runtime NS-Runtime Installer, PDF manual, hardware key (See note.) 3 licenses 10 licenses Model Standards NS-NSRCL1 CD NS-NSRCL3 --- NS-NSRCL10 Note: A hardware key (USB dongle) is required for NS-Runtime operation. ●System Requirements Item Specifications OS Windows XP (Service Pack 3 or higher), Vista, 7 or 8 (Support 64-bit version for Windows 7 and Windows 8.) CPU Celeron, 1.3 GHz or higher (Recommended) Memory size HDD: 50 MB min., RAM: 512 MB min. (Windows 7: 1 GB min.). 50 MB is required for the Runtime alone. (An additional 280 MB is required if CX-Server is not already installed.) 7 NS Series Software ●How to Select Required Support Software for Your Controller The required Support Software depends on the Controller to connect. Please check the following table when purchasing the Support Software. Item Omron PLC System Omron Machine Automation Controller System Controller CS, CJ, CP, and other series NJ-series and NX-series Programmable Terminals NS-series NS-series with an Ethernet port Software FA Integrated Tool Package CX-One Automation Software Sysmac Studio ●FA Integrated Tool Package CX-One Product name Specifications Number of licenses Media 1 license * DVD Model Standards CXONE-AL01D-V4 --- The CX-One is a comprehensive software package that integrates Support Software for OMRON PLCs and components. FA Integrated Tool Package CX-One Ver.4.@ CX-One runs on the following OS. Windows XP (Service Pack 3 or higher, 32-bit version) / Windows Vista (32-bit/ 64-bit version) / Windows 7 (32-bit/64-bit version) / Windows 8 (32-bit/64-bit version) / Windows 8.1 (32-bit/64-bit version) / Windows 10 (32-bit/64-bit version) CX-One Version 4.@ includes CX-Designer Ver.3.@. For details, refer to the CX-One catalog (Cat. No. R134) * Multi licenses (3, 10, 30, or 50 licenses) and DVD media without licenses are also available for the CX-One. ●Automation Software Sysmac Studio Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD. Specifications Product name The Sysmac Studio provides an integrated development environment to set up, program, debug, and maintain NJ/NX Series Controllers and other Machine Automation Controllers, as well as EtherCAT slaves. Sysmac Studio Standard Edition Ver.1.@ Model Standards Number of licenses Media - (Media only) DVD SYSMAC-SE200D --- 1 license * --- SYSMAC-SE201L --- Sysmac Studio runs on the following OS. Windows XP (Service Pack 3 or higher, 32-bit version) / Windows Vista (32-bit version) / Windows 7 (32-bit/64-bit version) / Windows 8 (32-bit/64-bit version) / Windows 8.1 (32-bit/64-bit version) / Windows 10 (32-bit/64-bit version) The Sysmac Studio Standard Edition DVD includes Support Software to set up EtherNet/IP Units, DeviceNet slaves, Serial Communications Units, and Support Software for creating screens on HMIs (CX-Designer). For details, refer to the Sysmac Integrated Catalogue (P072). Note: To connect the NJ5 Controller, NS system version 8.5 or higher is required. CX-Designer version 3.3 or higher is also required. To connect the NJ1/NJ3 Controller, NS system version 8.61 or higher is required. CX-Designer version 3.4 or higher is also required. To connect the NX7 Controller, NS system version 8.9 or higher is required. CX-Designer version 3.64 or higher is also required. * Multi licenses are available for the Sysmac Studio (3, 10, 30, or 50 licenses). 8 NS Series Cable Product name Cable *1 NSH5 Cables UL-compliant NSH5 Cable PT-to-PLC Connecting Cable *2 NSH5 Removable Box Cable Specifications Model Screen transfer cable for DOS/V (CX-Designer ↔ PT) Length: 2 m XW2Z-S002 USB-Serial Conversion Cable Length: 0.5 m CS1W-CIF31 USB relay cable Length: 1 m NS-USBEXT-1M RS-422A cable (loose wires + D-Sub 9-pin) Length: 10 m NSH5-422CW-10M RS-232C cable (loose wires + D-Sub 9-pin) Length: 3 m NSH5-232CW-3M RS-232C cable (loose wires + D-Sub 9-pin) Length: 10 m NSH5-232CW-10M RS-422A cable (loose wires) Length: 10 m NSH5-422UL-10M RS-232C cable (loose wires + relay cable) Length: 3 m NSH5-232UL-3M RS-232C cable (loose wires + relay cable) Length: 10 m NSH5-232UL-10M PT connection: 9 pins PLC connection: 9 pins Length: 2 m XW2Z-200T Length: 5 m XW2Z-500T PT connection: 9 pins PLC peripheral port Length: 2 m XW2Z-200T-2 RS-232C Cable (connectors) Length: 5 m XW2Z-500T-2 Length: 3 m NSH5-232CN-3M Length: 10 m NSH5-232CN-10M NSH5 Removable Box --- NSH5-AL001 NSH5 Wall-mounting Bracket --- NSH5-ATT02 NSH5 Visor --- NSH5-ATT01 Standards --N --- CU --- *1. Use a standard USB Type A male to Type B type male Cable to connect the NS series PT to a personal computer (CX-Designer). Use a standard USB cable to connect the NS series PT to a PictBridge-compatible printer. USB cable type depends on the printer. *2. To connect the NS series PT to NJ series Controller, using a commercially available 10/100-BASE-TX twisted-pair cable. For detail, refer to the NS series SETUP MANUAL (Cat. No.V083). 9 NS Series Options Product name Video Input Unit Specifications Model Inputs: 4 channels Signal type: NTSC/PAL Standards NS-CA001 UC1, CE Input channels: 2 video channels and 1 RGB channel *1 Signal type: NTSC/PAL NS-CA002 For Controller Link Communications NS-CLK21 Transmission distance: 500 m total length Note: Use this model when connecting PT models without a V@ suffix. Note: PT models with the V@ suffix can also be connected. NS-AL002 Transmission distance: 50 m total length Note: Only PT models with a suffix of V@ are connectable. Use the NS-AL002 to connect models without a V@ suffix. CJ1W-CIF11 Controller Link Interface Unit RS-422A Adapter Anti-reflection Sheets (5 surface sheets) Sheet/Cover *2 Protective Covers (5 pack) (anti-reflection coating) Protective Covers (1 cover included) (Transparent) Protective Covers (5 covers included) (Transparent) NS15-KBA04 NS12/10 NS12-KBA04 NS8 NS7-KBA04 NS5 NT30-KBA04 NS12/10 NS12-KBA05 NS8 NS7-KBA05 NS5 NT31C-KBA05 NS15 NS15-KBA05N NS12/10 NS12-KBA05N NS8 NS7-KBA05N NS5 NT31C-KBA05N NT625C/631/631C Series to NS12/10 Series NS12-ATT01 NT625C/631/631C Series to NS12/NS10 Series (Black) NS12-ATT01B NT610C Series to NS12/10 Series NS12-ATT02 NT620S/620C/600S Series to NS8 Series NS8-ATT01 NT600M/600G/610G/612G Series to NS8 Series NS8-ATT02 128 MB HMC-EF183 256 MB HMC-EF283 512 MB HMC-EF583 Memory Card Adapter --- HMC-AP001 Replacement Battery Battery life: 5 years (at 25°C) CJ1W-BAT01 Bar Code Reader CCD handheld bar code reader (RS-232C interface) V520-RH21-6 Attachment Memory Card *1. One screen cannot display two video inputs simultaneously. *2. A Chemical-resistant Cover (NT30-KBA01) is available only for the NS5. 10 NS15 UC1, CE --- UC1, N, L, CE --- CE --- NS Series General Specifications NS5/NS8/NS10/NS12/NS15 Series Rated power supply voltage NS5-V2 NS8-V2 NS10-V2 NS12-V2 NS15-V2 24 VDC Allowable voltage range 20.4 to 27.6 VDC (24 VDC ±15%) Power consumption 15 W max. Ambient operating temperature 0 to 50 °C (See note on the next page.) Note: The ambient operating temperature is subject to the following restrictions according to the mounting angle. Mounting angle of 0 to 30° to the horizontal: • When no Expansion Units are mounted, the operating temperature range is 0 to 45°C. • When a Video Input Unit or a Controller Link Interface Unit is mounted, the ambient operating temperature is 0 to 35°C. Mounting angle of 30 to 90° to the horizontal: Operating temperature range of 0 to 50°C 25 W max. 45 W max. Storage temperature −20 to 60 °C *1 Ambient operating humidity 35 to 85% (0 to 40 °C), 35 to 60% (40 to 50 °C) (with no condensation) Operating environment No corrosive gases. Noise immunity Conforms to IEC61000-4-4, 2 kV (power lines). 90° 5 to 8.4 Hz, 3.5 mm single amplitude, 8.4 to 150 Hz, 9.8 m/s2 10 min times each in X, Y, and Z directions 10 to 57 Hz, 0.075 mm amplitude, 57 to 150 Hz, 9.8 m/s2 30 min each in X, Y, and Z directions Shock resistance (during operation) 147 m/s2 3 times each in direction of X, Y, and Z Weight 1.0 kg max. Degree of protection Front operating panel: IP65 oil-proof type and NEMA4 UL type 4. *2 Note: May not be applicable in locations with long-term exposure to oil. Ground Ground to 100 Ω or less. Battery life 5 years (at 25 °C): Replace battery within 5 days after the battery runs low (indicator lights orange). Applicable standards Certified for conformance to UL 508, UL 1604, EMC Directive, NK, and LR Standards. 2.3 kg max. 2.5 kg max. *1. Operate the PT within the temperature and humidity ranges shown in the right diagram. *2. Support for NS5, NS10, NS12 and NS15. 4.2 kg max. Operation Storage 50 Temperature (°C) 0 −20 0 NSH5 Hand-held PT Series 30° Horizontal 0° Vibration resistance (during operation) 2.0 kg max. e ac urf ys pla Dis 10 20 40 30 Humidity (%RH) 95% 80% 60 60% 40% 35% 20% 10% 10 20 30 40 50 60 70 80 Temperature (°C) NSH5-V2 Type 5.7-inch Color TFT (Hand-held Version) Case color Black Built-in Ethernet port No Model NSH5-SQR10B-V2 (Emergency stop button: Red) Rated power supply voltage 24 VDC NSH5-SQG10B-V2 (Stop button: Gray) Allowable voltage range 20.4 to 27.6 VDC (24 VDC ±15%) Power consumption 10 W max. Ambient operating temperature 0 to 40°C Storage temperature −20 to 60°C Ambient operating humidity 35% to 85% (0 to 40°C) with no condensation Operating environment No corrosive gases. Noise immunity Common mode: 1,000 Vp-p (between power supply terminals and panel) Normal mode: 300 Vp-p Pulse width: 100 ns to 1 μs, Rise time: 1-ns pulse Vibration resistance (during operation) 10 to 57 Hz, 0.075 mm amplitude, 57 to 150 Hz, 9.8 m/s2 30 min each in X, Y, and Z directions Shock resistance (during operation) 147 m/s2 3 times each in direction of X, Y, and Z Weight 1 kg max. Degree of protection Equivalent to IP65. Ground Ground to 100 Ω or less. Battery life 5 years (at 25°C): Replace battery within 5 days after the battery runs low (indicator lights orange). Applicable standards Certified for conformance to UL 508, EMC Directive, and EN 60204-1. 11 NS Series Performance/Specifications NS5 Series NS5-V2 Model NS5-SQ10-V2 NS5-SQ11-V2 NS5-SQ10B-V2 NS5-SQ11B-V2 NS5-TQ10-V2 NS5-TQ11-V2 NS5-TQ10B-V2 NS5-TQ11B-V2 Built-in Ethernet port No Yes No Yes No Yes No Yes Case color Ivory Display device TFT color LCD Effective display area Width 117.2 × height 88.4 mm (5.7 inches) Display colors 256 colors Number of dots 320 dot horizontal × 240 dot vertical View angle Left/right: 80°, Top: 80°, Bottom: 60° *5 Screen data capacity 60 Mbytes Image data (BMP or JPG images) 32,768 colors Memory Card Supported Ladder Monitor function Not supported Video Input Unit support Not supported Controller Link Interface Unit (Wired) support Not supported Black Ivory Black Color High-luminance TFT *1 Service life * 3 75,000 hours min. Backlight *2 Brightness adjustment Three-level or 32-level brightness adjustment from the touch panel screen. * 4 Backlight error detection *5 Error is detected automatically, and the RUN indicator flashes green as notification. Method Matrix resistive membrane Number of Touch panel switches/ (matrix resolution type) Input Display text 300 (20 horizontal × 15 vertical) 16 × 16 dots for each switch Pressure-sensitive Service life 1,000,000 touch operations. Labels Can be specified in CX-Designer. Font, style, and size can be specified. Numerals, alarms, and character strings Scalable Gothic: Magnification: 6 to 255 points Rough: Magnification: 1×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8 Standard: Magnification: 1×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8 Fine: Magnification: 1×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8 7-segment display: Can display only numerals, dates, and times. Scalable Gothic, rough, standard, and fine can be used for 42 languages. Japanese, simplified Chinese, traditional Chinese, Korean, English, French, German, Italian, Portuguese, Spain, Swedish, Dutch, Supported Finnish, Norwegian, Basque, Catalan, Danish, Albanian, Croatian, Czech, Hungarian, Polish, Romanian, Slovak, Slovenian, languages (42 languages) Bulgarian, Belarusian, Russian, Serbian, Macedonian, Ukrainian, Georgian, Icelandic, Afrikaans, Faroese, Indonesian, Greek, Turkish, Estonian, Latvian, Lithuanian, Thai (supported only with scalable Gothic font) Text attributes Flicker Color 256 colors Font style (only when vector font is specified) Bold or italic Vertical alignment Top, center, or bottom Horizontal alignment Left-justified, centered, or right-justified Objects supporting flicker Functional objects: Select from up to 10 types of registered flicker settings. The flicker speed and flicker range can be set. Fixed objects: Select from three flicker types. Numeral units and scale settings 1.000 max. Alarm/event settings 5,000 max. Expansion interface For Expansion Interface Units *1. NS5-TQ series (high luminance TFT) luminance is better than that of NS5-SQ series by about 110 cd/m2. *2. Contact your nearest OMRON representative to replace the backlight. *3. This is the estimated time before brightness is reduced by half at room temperature and humidity. It is not a guaranteed value. The service life will be dramatically shortened if PT is used at low temperatures. For example, using the PT at temperatures of 0°C will reduce the service life to approximately 10,000 hours (reference value). *4. Lot No. 15Z0 or later of NS5 models. *5. This function does not indicate that the service life has been reached. It detects when the backlight is not lit due to a disconnection or other errors. Backlight error detection indicates that all backlights (2) are OFF. 12 NS Series NS8/NS10/NS12/NS15 Series NS8-V2 NS8NS8TV01- TV00B V2 -V2 Yes No Black Display device High-definition TFT color LCD High-definition TFT color LCD High-definition TFT color LCD Effective display area Width 170.9 × height 128.2 mm (8.4 inches) Width 215.2 × height 162.4 mm (10.4 inches) Width 246.0 × height 184.5 mm (12.1 inches) Display colors 256 colors Number of dots 640 dot horizontal × 480 dot vertical Left/right: 70°, Top: 65°, Bottom: 65° *3 800 dot horizontal × 600 dot vertical Left/right: 80°, Top: 80°, Bottom: 80° *3 View angle Screen data capacity Image data (BMP or JPG images) Memory Card Ladder Monitor function Left/right: 80°, Top: 80°, Bottom: 60° *3 60 Mbytes NS10TV00V2 No Ivory NS12TS01B -V2 Yes NS15-V2 NS15NS15TX01STX01BV2 V2 Yes Yes Silver Black High-definition TFT color LCD Width 304.1 × height 228.1 mm (15 inches) 1,024 dot horizontal × 768 dot vertical Left/right: 80°, Top: 70°, Bottom: 60° Supported Supported Supported (Image displayed via video input is 260,000 colors) Controller Link Interface Unit (Wired) support Service life * 2 Brightness adjustment Backlight *1 Backlight error detection *4 Not supported Number of Touch panel switches/ (matrix type) resolution Input Service life Labels NS12TS00V2 No Ivory 32,768 colors Video Input Unit support Method NS10TV01B -V2 Yes NS12-V2 NS12- NS12TS01- TS00B V2 -V2 Yes No Black Built-in Ethernet port Case color Model NS8TV01B -V2 Yes NS10-V2 NS10- NS10TV01- TV00B V2 -V2 Yes No Black NS8TV00V2 No Ivory (Only RGB input is enabled.) Supported 50,000 hours min. Three-level or 32-level brightness adjustment from the touch panel screen. * 3 Error is detected automatically, and the RUN indicator flashes green as notification. Matrix resistive membrane 768 (32 horizontal × 24 vertical) 20 × 20 dots for each switch 1,200 (40 horizontal × 30 vertical) 16 × 16 dots for each switch 1,900 (50 horizontal × 38 vertical) 16 × 16 dots for each switch Analog resistive membrane *5 Resolution: 1,024 (horizontal) × 1,024 (vertical) Pressure-sensitive 1,000,000 touch operations. Can be specified in CX-Designer. Font, style, and size can be specified. Scalable Gothic: Magnification: 6 to 255 points Numerals, Rough: Magnification: 1×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8 alarms, and Standard: Magnification: 1×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8 character Fine: Magnification: 1×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8 strings Display text 7-segment display: Can display only numerals, dates, and times. Scalable Gothic, rough, standard, and fine can be used for 42 languages. Supported Japanese, simplified Chinese, traditional Chinese, Korean, English, French, German, Italian, Portuguese, Spain, Swedish, Dutch, languages Finnish, Norwegian, Basque, Catalan, Danish, Albanian, Croatian, Czech, Hungarian, Polish, Romanian, Slovak, Slovenian, (42 languages) Bulgarian, Belarusian, Russian, Serbian, Macedonian, Ukrainian, Georgian, Icelandic, Afrikaans, Faroese, Indonesian, Greek, Turkish, Estonian, Latvian, Lithuanian, Thai (supported only with scalable Gothic font) Color 256 colors Font style (only when Bold or italic vector font is Text specified) attributes Vertical Top, center, or bottom alignment Horizontal Left-justified, centered, or right-justified alignment Objects Functional objects: Select from up to 10 types of registered flicker settings. The flicker speed and flicker range can be set. supporting Flicker Fixed objects: Select from three flicker types. flicker Numeral units and scale 1.000 max. settings Alarm/event settings 5,000 max. Expansion interface For Expansion Interface Units *1. Contact your nearest OMRON representative to replace the backlight. *2. This is the estimated time before brightness is reduced by half at room temperature and humidity. It is not a guaranteed value. The service life will be dramatically shortened if PT is used at low temperatures. For example, using the PT at temperatures of 0 °C will reduce the service life to approximately 10,000 hours (reference value). *3. Lot No. 28X1 or later of NS8 models, Lot No. 11Y1 or later of NS10 models, Lot No. 14Z1 or later of NS12 models, Lot No. 31114K or later of NS15 models. *4. This function does not indicate that the service life has been reached. It detects when the backlight is not lit due to a disconnection or other errors. Backlight error detection indicates that all backlights (2) are OFF. *5. An analog touch panel is used with the NS15. Do not press the touch panel in two or more places simultaneously. If the touch panel is pressed in two or more places simultaneously, it may activate a switch between the points that are pressed. 13 NS Series Communications NS5/NS8/NS10/NS12/NS15 Memory Card Interface One ATA-Compact Flash interface slot Functions Used to transfer and store screen data, store logging data, and store history data. (Alarm/Event History, Operation Log, and Error Log generated during Macro execution). Connector Conforms to EIA RS-232C. D-Sub female 9-pin connector 5-V output (250 mA max.) through pin 6. The 5-V outputs of serial ports A and B cannot be used at the same time. Functions Host (PLC) access: 1:N NT Links (connections with CS/CJ/CP-series PLCs and C200HX/HG/HE(-Z) PLCs), 1:1 NT Links, or Host Link (connections with C Series or CVM1/CV-series PLCs) Direct access to Temperature Controllers using Smart Active Parts: CompoWay / F and bar code reader connections (Read directly from display.) Connector Conforms to EIA RS-232C. D-Sub female 9-pin connector. 5-V output (250 mA max.) through pin 6. The 5-V outputs of serial ports A and B cannot be used at the same time. Functions Host (PLC) access: 1:N NT Links (connections with CS/CJ/CP-series PLCs and C200HX/HG/HE(-Z) PLCs) or 1:1 NT Links (connections with C Series or CVM1/CV-series PLCs) Direct access to Temperature Controllers using Smart Active Parts: CompoWay / F and bar code reader connections (Read directly from display.) USB rating USB1.1 Connector TYPE-B (Slave) Functions Connection with the CX-Designer (for screen data transfers) Connecting to a PictBridge-compatible Printer Recommended printers: EPSON: PM-G4500, PX-G5300, PX-5600, EP-901F Canon: PIXUS MX7600, PIXUS iP100, PIXUS iX5000 USB rating USB1.1 Connector TYPE-A (Host) Functions Connection with a printer (for hard copies) Recommended printers: EPSON: PX-G930 Conformance standards Conforms to IEEE 802.3/Ethernet (10 Base-T/100 Base-TX). Functions Host (PLC) access and connection with the CX-Designer (for screen data transfers) Baud rate 2 M/1 M/500 K bps Transmission path Shielded twisted-pair cable (special cable) Functions Host (PLC) access and data links Resolution NS-CA001: 320×240, 640×480, 800×600 dots NS-CA002: User-defined size Input signal NS-CA001: NTSC composite video or PAL NS-CA002: NTSC composite video or PAL Number of video inputs NS-CA001: Number of cameras: 4 max. NS-CA002: 2 cameras + RGB Port A Serial Communications Port B USB SLAVE Specifications USB HOST Specifications *1 Built-in Ethernet Specifications *2 Controller Link (Wiredtype) Specifications *3 Video Input Specifications *4 *1. Except NS5. *2. NS@-@@@1-V2 only. *3. Except NS5 and NS8. *4. Except NS5 and NS15. NS15 provides RGB input. (NS-CA002) 14 NS Series Connectable Devices Supported OMRON PLCs PLC series C Series CVM1/CV Series CS Series CJ Series CP Series PLC model name RS-232C *1 1:1 NT Link Ethernet 1:N NT Link Host Link FINS *2 EtherNet/IP *3 Controller Link *4 CQM1 Yes No Yes No No No CQM1H Yes Yes Yes No No Yes CPM1 Yes No Yes No No No CPM1A Yes No No No No No CPM2A Yes No Yes No No No CPM2C Yes No Yes No No No C200HS Yes No Yes No No No C200HE (-Z) Yes Yes Yes No No Yes C200HG (Z) Yes Yes Yes No No Yes C200HX (-Z) Yes Yes Yes No No Yes CV500/1000/2000 Yes No Yes Yes No Yes CVM1 Yes No Yes Yes No Yes CS1H No Yes Yes Yes Yes Yes CS1G No Yes Yes Yes Yes Yes CS1D No Yes Yes Yes Yes Yes CJ1H No Yes Yes Yes Yes Yes CJ1G No Yes Yes Yes Yes Yes CJ1M No Yes Yes Yes Yes Yes CJ2H No Yes Yes Yes Yes Yes CJ2M No Yes Yes Yes Yes Yes CP1H No Yes Yes Yes Yes No CP1L No Yes Yes Yes No No CP1E No Yes Yes No No No Yes *5 Yes *5 Yes *5 No Yes *6 No No No No No Yes No NJ Series NJ5/NJ3/NJ1 NX Series NX7 Note: Including models whose production were discontinued. *1. To connect a NS with a PLC via a RS-422A connection, OMRON's NS-AL002, or CJ1W-CIF11 RS-232C/RS-422A Converter can be used to convert the RS-232C port on the NS to RS-422A. *2. A NS with Ethernet port is necessary. When connecting a PLC with the NS, an Ethernet port is necessary on the PLC, too. Use a PLC CPU Unit with a built-in Ethernet port, or add an Ethernet Unit. *3. A NS with Ethernet port is necessary. When connecting a PLC with the NS, an EtherNet/IP port is necessary on the PLC, too. Use a PLC CPU Unit with a built-in EtherNet/IP port, or add an EtherNet/IP Unit. *4. Install a Controller Link Interface Unit on the NS. A Controller Link Unit is necessary for the PLC. *5. Mount a Serial Communications Unit on the NJ-series Controller. A NS can access only to the Controller's memory used for CJ-series unit. *6. When using a EtherNet/IP Unit to connect the NJ-series Controller, NJ Troubleshooter is not supported. 15 NS Series Function Comparison PLC series C series CVM1/CV series PLC model name Ladder Monitor Device Monitor/ Switch Box PLC Data Trace SPMA SAP NJ EtherNet/IP Troubleshooter/ Tag access PLC Integrated (Network Troubleshooter NS-series PT symbols) simulation *4 CQM1 No No No No No No No CQM1H No No No No No No No No CPM1 No No No No No No No No CPM1A No No No No No No No No CPM2A No No No No No No No No CPM2C No No No No No No No No C200HS No No No No No No No No C200HE (-Z) No No No No No No No No C200HG (-Z) No No No No No No No No C200HX (-Z) No No No No No No No No CV500/1000/2000 No No No No No No No No CVM1 No No No No No No No No CS1H Yes Yes Yes Yes Yes No Yes No CS1G Yes Yes Yes Yes Yes No Yes No CS1D Yes Yes Yes Yes Yes No Yes No CJ1H Yes Yes Yes Yes Yes No Yes No CJ1G Yes Yes Yes Yes Yes No Yes No CJ1M Yes Yes Yes Yes Yes No Yes No CJ2H Yes Yes Yes Yes Yes Yes Yes No CJ2M Yes Yes Yes Yes Yes Yes Yes No CP1H Yes Yes Yes Yes *1 Yes No No No CP series CP1L Yes Yes Yes Yes *1 Yes No No No CP1E No No No Yes *1 Yes No No No NJ series NJ5/NJ3/NJ1 No Yes *2 No No Yes *3 Yes No Yes NX Series NX7 No No No No No Yes No Yes CS series CJ series Note: Including models whose production were discontinued. *1. The SPMA relaying a PLC is not supported. *2. Only Device Monitor function is supported. Monitoring function that uses tags (variables) is not supported. *3. The SAP for CJ-series Special I/O Units and CPU Bus Units that can be used with NJ-series Controller is supported. *4. Sysmac Studio version 1.02 or higher (CX-Designer version 3.41 or higher) is required. 16 No NS Series Connectable Inverters Series 3G3MX2-V1 Communication Unit Connection (Use the RS-485 terminal on the Inverter) 3G3JX (Use the RS-485 connector on the Inverter) 3G3RX-V1 (Use the RS-485 terminal on the Inverter) RS-485 (2-wire) 1:N Connectable Temperature Controllers The following Temperature Controllers can be connected directly to an NS-series PT*. Unit name Series Model Modular Temperature Controller EJ1 EJ1-EDU End Unit Modular Temperature Controller E5ZN E5ZN-SCT24S Terminal Unit E5AR E5AR-@@@@@@@@@-FLK E5ER E5ER-@@@@@@@@@-FLK Digital Controller Remarks E5CN-@@@@@T-FLK Multi-input (Thermocouple/Resistance Thermometer) Type E5CN-@@@@@L-FLK Analog Input Type E5AN/E5EN/E5CN (Basic Model) E5EN-@@@@@T-FLK Multi-input (Thermocouple/Resistance Thermometer) Type E5EN-@@@@@L-FLK Analog Input Type SAP screens are available. E5AN-@@@@@T-FLK Multi-input (Thermocouple/Resistance Thermometer) Type Temperature Controller (Digital Controller) E5AN-@@@@@L-FLK Analog Input Type E5AN-H/E5EN-H/ E5CN-H (Advanced Model) E5GN E5CN-H@@@@@@@-FLK Universal-input Model E5EN-H@@@@@@@@-FLK Universal-input Model E5AN-H@@@@@@@@-FLK Universal-input Model E5GN-@@@TC-FLK Thermocouple Input Type E5GN-@@@P-FLK Resistance Thermometer Input Type Note: Including models whose production were discontinued. * The NS-Runtime cannot be connected directly to a Temperature Controller. 17 NS Series Connecting to Another Company’s PLC Manufacturer Series A Series FX Series Mitsubishi Electric Q/QnA Series CPU Computer Link Unit A1SJ71UC24-R@ A1SJ71UC24-PRF A2ACPU Computer Link Unit AJ71UC24 FX0N FX1S FX1N FX1NC FX2N FX3UC FX3G Communication special adapter FX3U-232-ADP FX2NC-232ADP FX0N-232-ADP Connection diagram RS-232C, RS422A/485 *1 1:1 RS-232C, RS422A/485 *1 1:1 RS-232C 1:1 RS-232C, RS-485 (4-wire) *2 1:N Communication expansion board FX@@-232-BD Q00CPU Q01CPU RS-232C port on the CPU Module Q00CPU Q01CPU Q00JCPU Q02CPU Q02HCPU Q06HCPU Q12HCPU Q25HCPU Q03UDCPU Q06UDHCPU Q13UDHCPU Serial Communications Module QJ71C24N-R2 QJ71C24N-R4 QJ71C24N Q2ASCPU Q2ASCPU-S1 Q2ASHCPU Q2ASHCPU-S1 Serial Communications Module A1SJ71QC24N CPU built-in RS-232C port RS-232C Personal Computer Link Module F3LC11-1F F3LC12-1F F3LC11-2F RS-232C, RS-422A/485 *1 CPU313 CPU315-2DP CPU317-2PN/DP SIMATIC S7 HMI Adapter 6ES7 972-0CA1@-0XA0 RS-232C 1:1 SLC5/03 SLC5/04 SLC5/05 RS-232C port on the CPU Module RS-232C 1:1 1:1 Yokogawa Electric FA-M3(R) Series F3SC23-1F F3SP21-0N F3SP28-3S F3SP58-6S F3SP67-6S Siemens S7-300 Series SLC500 Rockwell (Allen-Bradley) Communication Unit/Adapter/Board A1SHCPU A2USCPU A2USHCPU-S1 MicroLogix MicroLogix 1500 RS-232C port on the CPU Module RS-232C ControlLogix Logix5555 RS-232C port on the CPU Module RS-232C 1:1 CompactLogix 1769-L31 RS-232C port on the CPU Module RS-232C 1:1 PLC-5 PLC-5/20 RS-232C port or RS-485 port on the CPU Module RS-232C/RS-485 (4-wire) 1:N *1. To connect using RS-422A/485, an RS-232C/422A converter (e.g. NS-AL002, CJ1W-CIF11) is required. *2. To connect using RS-485, an RS-232C/422A converter (e.g. NS-AL002, CJ1W-CIF11) is required. Up to 32 sequencers can be connected when using RS-485. 18 1:1 NS Series Component Names and Options NS15 RS-422A/485 Serial Interface Memory Card interface Memory Card Note: Colors shown in photographs and product names may differ from actual colors and names. Expansion interface Battery Analog RGB Output RS-232C serial port A RS-232C serial port B A bar code reader can be connected to the serial port. Recommended bar code reader: V520-RH21-6 Connector for Brightness Adjustment Ethernet (10 Base-T or 100 Base-TX) Power Supply (24 VDC) USB SLAVE (For transferring screens and connecting a PictBridge-compatible printer) USB HOST (for printer) NS12/10 Memory Card interface Memory Card Note: Colors shown in photographs and product names may differ from actual colors and names. Expansion interface Battery RS-232C serial port A RS-232C serial port B Power Supply (24 VDC) A bar code reader can be connected to the serial port. Recommended bar code reader: V520-RH21-6 Ethernet (10 Base-T or 100 Base-TX) USB SLAVE (For transferring screens and connecting a PictBridge-compatible printer) USB HOST (for printer) NS8 Memory Card interface Expansion interface Memory Card Battery RS-232C serial port A RS-232C serial port B Power Supply (24 VDC) Note: Colors shown in photographs and product names may differ from actual colors and names. A bar code reader can be connected to the serial port. Recommended bar code reader: V520-RH21-6 Ethernet (10 Base-T or 100 Base-TX) USB SLAVE (For transferring screens and connecting a PictBridge-compatible printer) USB HOST (for printer) 19 NS Series NS5 Memory Card interface Memory Card Note: Colors shown in photographs and product names may differ from actual colors and names. Expansion interface Ethernet (10 Base-T or 100 Base-TX) USB SLAVE (For transferring screens and connecting a PictBridge-compatible printer) Battery Power Supply (24 VDC) RS-232C serial port A RS-232C serial port B A bar code reader can be connected to the serial port. Recommended bar code reader: V520-RH21-6 NSH5 USB Port Enable Switch Memory Card interface LED Emergency Stop Switch Function Switches Hand Strap Cable Optional Products Video Input Unit NS-CA001 (with Cover) RGB/Video Input Unit NS-CA002 (with Cover) Controller Link Interface Unit RS-422A Adapter NS-CLK21 (with Cover) CJ1W-CIF11 Communications Cable XW2Z-S002 Protective Cover/Anti-reflection Sheet for NS-series PT NS-KBA0 (N) NT30/NT31C-KBA05 (N) USB Serial Conversion Cable USB relay cable CS1W-CIF31 (IP65 oil-proof type) NS-USBEXT-1M 20 RS-232C/RS-422A Conversion Unit NS-AL002 NS Series Dimensions (Units: mm) NS15 170 Mounting Panel Mounting Bracket 79.54 13.95 94.8 RUN RDA RDB SDA 46 SDB 27.4 282 304.5 304 71.8 RSA RSB 57.31 3.8 86.83 85.6 8 405 37.9 (min.) 41.1 (max.) 39.4 84.1 70 75.8 Recommended Panel Cutout Dimensions 15.5 340 383 405.5 +1 282.5 −0 383.5 +1 −0 NS12/10 Recommended Panel Cutout Dimensions 140 241 228 +1 −0 SW 227 249 RESET 121 24V DC PORT B HOST 134 PORT A SLAVE ETHERNET 15.5 264 315 323 7.5 39 (min.) 48.5 42 (max.) 3.8 49 302 +1 −0 13.7 49.9 23 90.4 301 NS8 NS5 39.83 165 188 177 27.3 15.5 5 48.5 153.3 130.5 RUN 142 44.55 180 232 195 39 (min.) 42 (max.) 15.5 5 145 90 49 53.8 206.3 220 34 (min.) 38 (max.) 54.8 183.5 Recommended Panel Cutout Dimensions Recommended Panel Cutout Dimensions SW 131 +0.5 −0 RESET 24V DC 120.5 PORT B PORT A 68.48 165.5 +0.5 −0 107.6 ETHERNET HOST ETHERNET 21 51.7 19.1 220.5 +0.5 −0 26.6 9.6 19.5 184 +0.5 −0 77 44.1 50.1 63.4 21 NS Series Hand-held NS5 16.5 223 70.5 75 50 176 75 81.3 9.6 164 (169) 9.6 164 (169) (1.9) 127.3 50.3 68.3 86.3 104.3 9.7 20.4 11 (102.7) 151.5 (183) 21.4 5 (22.3) 10.6 81.3 (102.7) 21.4 (1.9) NS-CLK21 Controller Link Interface Unit NS-CA002 Video Input Unit NS-CA001 Video Input Unit 31.5 9.7 (22.3) 11.1 5 5 164 20.4 11 (1.9) 39.3 57.3 82.8 118.3 (169) 10.8 (33.9) 32 11 95.6 Related Manuals Cat. No. V083 22 Model Manual NS15/NS12/NS10/NS8/NS5 NS-Series Programmable Terminals SETUP MANUAL NS-Series Programmable Terminals PROGRAMMING MANUAL V073 NS15/NS12/NS10/NS8/NS5 V099 NS-CXDC1-V3 CX-Designer Ver.3.@ USER'S MANUAL V082 NS NS-Series Ladder Monitor OPERATION MANUAL (Ladder Monitor I/O Comment Extracting Tool) V086 NS-CA002 NS-Series RGB and Video Input Unit OPERATION MANUAL V090 NSH5 NSH5-Series Hand-held Programmable Terminal OPERATION MANUAL NS-Series Programmable Terminals HOST CONNECTION MANUAL (Host Link) OPERATION MANUAL V098 NS15/NS12/NS10/NS8/NS5 V085 NS15/NS12/NS10/NS8/NS5 NS-Series Programmable Terminals HOST CONNECTION MANUAL V092 NS15/NS12/NS10/NS8/NS5 NS-Series Programmable Terminals HOST CONNECTION MANUAL Multivendor Connection V075 NS15/NS12/NS10/NS8/NS5 NS-Series Programmable Terminals Macro Reference V093 NS-NSRCL@@ NS-NSRCL@@ NS-Runtime Software USERS MANUAL Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines,vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRONÅfs test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. Note: Do not use this document to operate the Unit. OMRON Corporation Industrial Automation Company Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 © OMRON Corporation 2011 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_11_5_0516 Cat. No. V405-E1-14 0712 (1206)