Download

P rog ra m m ab le Te rmina ls
NS Series
NS, the HMI brand you can rely on
»
Proven Reliability
» Best
Match
» Machine Management
NS, the HMI brand you can rely on
Machine Control at Your Fingertips.
On-screen Machine Management.
Expanding markets in emerging countries, short
product cycles, and diversifying customer needs
are just some of the factors that create drastic
Let Your Machines Evolve
changes for the production industry.
To win in severe global market competition, you
Best Match
OMRON has provided even greater compatibility with
have to continue to grasp industry changes
OMRON PLCs and components to provide an advanced
quickly, understand user needs accurately, and
design process that lets you achieve appealing
provide diverse forms of added value.
machines.
OMRON will help you handle ever-changing
customer needs with the three keywords of the
NS Series.
Machine Management
The NS Series transforms machine HMIs from simple
operation panels and turns them into machine
management tools.
Proven Reliability
The NS-series PTs have a proven track record that
will take your machines to a higher level of reliability.
2
The Best Match Possible
Machine Management Tool
Proven Reliability
The amount of work and cost of connecting to
The machine designer can easily implement
In the ten years since initial marketing,
OMRON PLCs and components have been
PLC troubleshooting, machine troubleshooting,
OMRON has globally supplied numerous HMI
greatly reduced. The results is an incredible
settings for servo drives, temperature
solutions with the highly reliable NS Series at
range of features that is possible only when
controllers, and other control components,
over 200 sales and service centers around the
unifying to one manufacturer. Connecting to
status monitoring of connected devices, and
world.
the NJ-series Machine Automation Controller
uploading/downloading of parameters.
allows the machine designer to quickly
achieve the features required by the user
through support for improved troubleshooting
and structured programming with structures
and other new data types.
3
NS Series Lineup
This powerful lineup showcases OMRON's unique value.
Choose from 3 types to match your application and requirements.
NS Series
Standardd Models
15
Plentiful scree
screen variations and diverse functions allow usee in a wide variety of applications.
inches Color TFT
NS15-TX
12.1
inches Color TFT
NS1
NS12-TS
32,768 colors
SVGA 800 x 600 pixels
Screen memory size: 60 MB
32,768 colors
XGA 1024 x 768 pixels
Screen memory size: 60 MB
USB Slave
Ethernet
USB Master
RS-232C x 2
Controller Link
USB Slave
Video (RGB input only)
Ethernet
RGB output
USB Master
RS-232C x 2 Ladder Monitor
RS-422A/485 Memory Card
10.4
inches Color TFT
8.4
NS10
NS10-T
T
NS10-TV
inches Color TFT
32,768 colors
VGA 640 x 480 pixels
Screen memory size: 60 MB
USB Slave
Ethernet
USB Master
RS-232C x 2
5.7
NS8 TV
NS8-TV
V
32,768 colors
VGA 640 x 480 pixels
Screen memory size: 60 MB
Controller Link
Video
Ladder Monitor
Memory Card
USB Slave
Ethernet
USB Master
RS-232C x 2
5.7
Video
Ladder Monitor
Memory Card
inches Color TFT
inches Color High-Iuminance TFT
NS5-TQ
NS5
TQ
32,768 colors
QVGA 320 x 240 pixels
Screen memory size: 60 MB
NS5 SQ
NS5-SQ
32,768 colors
QVGA 320 x 240 pixels
Screen memory size: 60 MB
USB Slave
Ethernet
RS-232C x 2
Memory Card
USB Slave
Ethernet
RS-232C x 2
Memory Card
NSH Series
Hand-held
d Models
5.7
A hand-held ve
version of the NS5 is now available to perform operations
op
at the production site.
inches
nches Color TFT
NSH5-SQR
32,768 colors
QVGA 320 x 240 pixels
inches
ches Color TFT
Hand-held PT Cable
NSH5 SQG
NSH5-SQG
32,768 colors
QVGA 320 x 240 pixels
USB Slave
USB Slave
RS-232C/422A
Memory Card
RS-232C/422A
Memory Card
Equipped with a red switch for an emergency stop input.
Emergency stop (3 inputs)
4
5.7
Equipped with a gray switch for a stop input.
Emergency stop (3 inputs)
RS-232C
RS-422A
Controller Link
Video
Ladder Monitor
Memory Card
NSJ Series
Integrated Controller
oller Models
12.1
PT is unified with the
t Controller into one package to greatly help standardize equipment and reduce size.
inches Color TFT
NSJ12-TS
NSJ12
-G5D
10.4
inches Color TFT
32,768 colors
SVGA 800 x 600 pixels
Screen memory size: 60 MB
USB Slave
Ethernet
USB Master
RS-232C x 3
USB Slave
Ethernet
USB Master
RS-232C x 3
NSJ8 TV
NSJ8-TV
V
-M
M3
3D
-M3D
8.4
inches Color TFT
NSJ8 TV
NSJ8-TV
V
32,768 colors
VGA 640 x 480 pixels
Screen memory size: 60 MB
inches Color TFT
NSJ5 SQ
NSJ5-SQ
Q
USB Slave
Ethernet
USB Master
RS-232C x 3
n
n)
(Controller Section)
M3D
I/O points: 640
t 20K stepss
ty:
Program capacity:
2K words
Data Memory: 32K
Controller Link
Ladder Monitor
Memory Card
DeviceNet
(Controller Section)
I/O points: 1,280
P
Program
capacity:
cappacitty: 60K stepss
Data Memory: 128K words
-M
M3D/-G5
M3
-M3D/-G5D
5. 7
inches Color High-Iuminance TFT
Controller Link
Memory Card
DeviceNet
G5D
G
I points:
I/O
po
12
1280
2 0
280
P g
Program
cap
p iity:
pa
paci
y 60K steps
ps
capacity:
D Memory:
Data
Memoryy:
y 1128K words
NSJ5 TQ
NSJ5-TQ
Q
-M
M3D/
M3
3D/-G
G
G5
-M3D/-G5D
32,768 colors
QVGA 320 x 240 pixels
Screen memory size: 60 MB
32,768 colors
QVGA 320 x 240 pixels
Screen memory size: 60 MB
USB Slave
Ethernet
RS-232C x 3
-G
G5D
-G5D
32,768 colors
VGA 640 x 480 pixels
Screen memory size: 60 MB
Controller Link
Ladder Monitor
Memory Card
DeviceNet
(Controller Section)
I/O points: 640
Program cap
capacity:
paciity: 20K stepss
ords
Data Memory: 32K words
5. 7
Controller Link
Ladder Monitor
Memory Card
DeviceNet
(Controller Section)
I/O points: 1,280
Program capacity: 60K steps
Data Memory: 128K words
inches Color TFT
USB Slave
Ethernet
USB Master
RS-232C x 3
-G5D
32,768 colors
VGA 640 x 480 pixels
Screen memory size: 60 MB
Controller Link
Ladder Monitor
Memory Card
DeviceNet
(Controller Section)
I/O points: 1,280
Program capacity: 60K steps
Data Memory: 128K words
8.4
NSJ10-TV
NSJ10
n
n)
(Controller Section)
M3D
I/O points: 640
y 20K steps
y:
Program capacity:
2K words
Data Memory: 32K
USB Slave
Ethernet
RS-232C x 3
Controller Link
Memory Card
DeviceNet
G5D
G
I/O
I/
/O points: 1280
/O
12280
2
P g
Program
capa
pacit
a tty:
y 60K steps
ps
capacity:
D Memory
Data
y: 12
128K words
Memory:
Software
CX-Designer
NS-Runtime
Without screen creation and ladder
programming, the CX-Designer Screen
Design Software is so easy-to-use
that anyone can master it.
This software enables PLC
communications from a personal
computer by manipulating PT
screens created using the
CX-Designer.
5
A Revolutionary Best Ma
The NS-series PTs provide revolutionary compatibility with the road-proven CS/CJ-series
the new NJ-series Controllers to achieve even greater added value in user machines.
The NJ-series Machine
Automation Controllers
Revolutionize Productivity
You can create a flexible, high-speed,
high-precision system based on the NJ-series
Machine Automation Controllers.
Use tags to access any memory areas, or
troubleshoot machines and systems by using
EtherNet/IP
the NS-series PTs to make the most of the
strengths of the NJ-series Controllers and to
manage machines.
EtherCAT
6
tch
PLCs and
The CS/CJ-series PLCs for
the Reliability of a Proven
Track Record
Features are provided to easily connect to
CS/CJ-series PLCs to take advantage of their
proven track record.
Many features that do not require screen
creation or programming support everything
from design through maintenance to take
advantage of the compatibility of OMRON
PLCs and PT and to serve as the face of your
machines.
7
Power Support for All User
From conceptual designs through commissioning, operation, and maintenance, the NS
Design
Reduced work
For Machine Automation
Controllers NJ-series
P10
NJ Troubleshooter
Integrated NS-series PT simulation
P 11
Troubleshooter
P 19
Plentiful Graphing Functions
PLC Troubleshooter
Machine Troubleshooter
Best Match with
OMRON Products
Screen Data
Security Functions
P12 - P16
Smart Active Prarts (SAP)
P 20
P 20
Device Data Transfer
With EtherNet/IP
Direct Connection to Temperature Controllers
Face Plate Auto-Builder for NS
NS Screen Templates
Multi-language Support
Multifunction Objects
8
P 17
P 18
CX-Designer Screen
Design Software
NEW
P 21
P 22- P 25
Needs
Series supports every user need.
Startup/Operation
Attractive,
convenient features
for easier operation
Maintenance
Features for reliability
and complete
maintenance
P 26
260,000-color Video Display
Comparison
Analog RGB Output
FTP Function
User Security Functions
LED backlight
P 28
NEW
P 26
Single Port Multi Access
P 28
PLC Data Trace
P 29
Operating log
P 29
P 27
P 27
P 27
Ladder Monitor
P 30- P 31
9
For Machine Automation Controllers NJ-series
Use Integrated NS-series PT simulation or NJ
troubleshoot by using the NS-series PTs to make the
most of the strengths of the NJ-series Controllers and
to manage machines.
NJ Troubleshooter
Controller Errors
Standard Feature for NJ-series Controllers
Errors are automatically detected and displayed on-screen along with corrective
actions for the CPU Unit function modules, EtherCAT slaves, and CJ-series Units
that are connected in the NJ-series Controller. Whenever an error might occur,
you can recover normal operation quickly to reduce downtime without using user
manuals or Support Software on a computer.
NJ Controller
User-defined Errors
No Work Is Required to Create Alarm Screens.
Frames for alarm screens are provided as standard features in the NS-series PTs.
You do not need to create screens to complete alarm screens.
Management of the meanings of alarms is unified on the Controller, so you do not
have to register, add, or correct addresses on the NS-series PTs.
Transfer
Copy
and
Paste
Excel
Alarm Specifications
Alarms
displayed
Sysmac Studio
Alarm Registration and
Programming Detection Conditions
NJ Controller
Unified Alarm Definitions
No screen creation is required
Integrated NS-series PT simulation
Improved debugging efficiency
"Integrated simulation" of Sysmac Studio enables offline debugging of the screen
data for the NS-series PTs and sequence program for the NJ-series on the
computer.
* Sysmac Studio version 1.02 or higher (CX-Designer version 3.41 or higher) is required.
Test screen of CX-Designer appears after
synchronization of Sysmac Studio, and
integrated simulation starts.
Select Integrated
Simulation.
Select image data and host
to simulate.
10
Design
Startup/Operation
Troubleshooter
A Troubleshooter is provided for the connected
OMRON Controller or PLC. This greatly reduces
work requirements.
Maintenance
CS/CJ-series PLC Troubleshooter
Constantly monitors PLC errors.
NS-Run
NS-Runtime
untim
timee
Automatically detects PLC errors and displays the error
details and recovery procedure on the screen. Even if a
problem occurs, it can be resolved quickly without
referring to the manuals.
Hand-held PT
Hand
CS/CJ/CP-series PLC
Features
Note: A special template is required when using this
function. The screen template is supplied with
CX-Designer of version 2.1 or later. This function
is a standard feature in the NSJ-series PTs.
Network
Machine Troubleshooter
Easier Design of Machine Error Screens
With this system, this
frame is shared, and the
error details in the pink
frames are switched
with an alarm or other
item as the trigger.
Text selection
System Configuration
Individual error screens that were previously made for
each error can now be integrated into one. It is
possible to switch only the error details (text and
screen) without ladder programming in conjunction
with the alarm bit.
Image selection
Specific Example
Ordering Information
in conjunction with an alarm bit (See note.)
Alarm bit 10.01 ON
(no paper)
Specifications
Alarm bit 10.02 ON
(printing error)
Note: Alarms, PLC/PT memory, and other items can be
selected for the switching trigger.
11
Best Match with OMRON Products
NS Series is the most suitable HMI for the system
that comprises OMRON components. The advantage
is the "compatibility (reducing programming and
screen data creation work)" which will reduce the
amount of designing work.
No Screen Designing / No Programming
NS
PLC CPU Unit
monitoring screen
Device monitor
PLC Data Trace
Temperature
Controllers
PLC
CPU Bus Units and
Special I/O Units
Remote I/O Terminal
Inverter
Temperature Controllers
Servomotor Servo Driver
SAP Library
Troubleshooting
Vision Sensor
260,000-color
video input
12
Design
The Temperature Controller's setting and
monitor screens are completed in no time.
Startup/Operation
Smart Active Parts (SAP Library)
Dramatically reduces the effort required
to create ladder programming and screens.
SAP Library, Temperature
Controller Parts
Maintenance
More than 3,000 Library parts (Smart Active Parts)
are available, which can directly access OMRON
PLCs and components. The objects can just be
pasted from the Smart Active Parts (SAP Library)
Library to the screen; it is completely unnecessary
to create screens and ladder programming.
ACCESS
CX-Designer Screen
Design Software
NS-Runtime
ACCESS
Example screens using support tool objects (Tool Function SAP Library)
PLC CPU Unit monitoring screen
Features
Plenty of support tool objects (the Tool Function SAP
Library) are available, which can be easily
incorporate support tool functions in the NS-series
PT. Just paste the support tool objects in the screen
to check for errors and make settings, even without
a computer.
Hand-held PT
Support tool objects can be incorporated
to check for errors and make settings,
even without a computer.
Computer support tools
Network
NCF Unit setting screen
Troubleshooter SAP for a Position Control Unit
Troubleshooter SAP for Basic I/O Unit
Specifications
A Troubleshooter SAP Library is available to
troubleshoot each Unit in the PLC. When an error
occurs in a Unit, the Troubleshooter SAP Library
provides an easy-to-understand explanation of the
cause of the error as well as the countermeasures.
To
Ordering Information
CPU Bus Unit and Special I/O Unit
Troubleshooting Can Be Also Performed
with the SAP Library.
System Configuration
From
DeviceNet monitoring screen
Note: The Troubleshooter SAP Library is included as a standard feature for
the CX-One and CX-Designer. For details, refer to page 56. Successive
development for Ethernet Units and MC Units is planned for the future.
13
Design
EtherNet/IP
Startup/Operation
Simultaneous and parallel engineering
The host applications can be designed using the tag
names of the PLC and PT. Parallel development will
shorten the design time.
Support for data structures
This special feature is made possible by combining an
OMRON CJ2 PLC with an NS-series PT. The data
structures that you define on the Programming Tool can be
used on the CX-Designer simply by dragging and dropping
them.
EtherNet/IP
NS Series
CX-Designer
Case 2
The screen graphics are created in
advance, and then addresses are allocated
and checked after the ladder program is
completed.
Programmable Terminal screens are created.
Ladder program is created.
PLC
Programmable Terminal
Ladder program is created.
The addresses are set.
PLC
Programmable Terminal screens are created (graphics only).
NS-Runtime
Note: An EtherNet/IP connection is required.
For CJ2 Series, CX-Designer version 3.2 or later, and NS system version
8.4 or later are required.
For NJ5, CX-Designer version 3.3 or later, and NS system version 8.5 or
later are required. For NJ3, CX-Designer version 3.4 or later, and NS
system version 8.61 or later are required.Moreover, the multidimensional
array is supported in the combination with NJ.
FROM
CJ2/NJ
Maintenance
Case 1
Previously, the PLC program was first
created, and then the ladder program was
referenced to create the screens.
Addresses are allocated and the allocations are checked
Programming Tool
Definition of the "Motor" Symbol
Programmable Terminal
Drag
&
Drop
Programmable Terminal
Address
Ladder program is created.
Number_produced Undetermined
By simply setting tag names,
PLC and Programmable
Terminal programming can be
performed in parallel.
CJ2/NJ
Design time is shortene
…
Number_of_times Undetermined
…
TO
Tag name
Hand-held PT
Addresses are determined
while creating the ladder
program.
Specifications
The screens are created.
NS Series
The screens are created
with no need to pay
attention to addresses.
Features
Tag access
Design time is
shortened.
1. Tag names are managed at the PLC with the CX-Programmer.
A tag is a name given to an address. Tags are managed in
the CJ2 CPU Unit, where they are defined as network
symbols. The common user-defined tag names are used
from Programmable Terminals and host applications to
access memory in a CJ2 CPU Unit without knowing the
physical address.
Tag name
Number_produced
Address
D100
Minimize side effect of address changes
Network
2. For example, create screens with tag names without typing the physical address.
It is possible to access memory with tags, so the PT and
host application are not affected even if the address of
data in the PLC is changed.
Specific Example
No change required.
Host application
3. All devices will access with Common “Tag”
Number_produced
Tag name
Number_produced
Number_produced
Data links
Accessed by
tag name.
Address
Number_produced
System Configuration
Host application
1. With the CX-Programmer, the address for the tag named
“Number_produced” is changed from D100 to H200.
Number_produced
D100
Number_produced
Accessed using a tag.
Change
Number_produced
CJ2/NJ
14
No change
required.
CJ2/NJ
2. Applications and the PT are accessed using tags, and so
changes do not need to be made at other devices.
Even after the change, the number of items produced is
acquired correctly from H200.
Specifications
NS Series
H200
Ordering Information
CJ2/NJ
NS Series
15
Design
EtherNet/IP
Startup/Operation
Simultaneous and parallel engineering
The host applications can be designed using the tag
names of the PLC and PT. Parallel development will
shorten the design time.
Support for data structures
This special feature is made possible by combining an
OMRON CJ2 PLC with an NS-series PT. The data
structures that you define on the Programming Tool can be
used on the CX-Designer simply by dragging and dropping
them.
EtherNet/IP
NS Series
CX-Designer
Case 2
The screen graphics are created in
advance, and then addresses are allocated
and checked after the ladder program is
completed.
Programmable Terminal screens are created.
Ladder program is created.
PLC
Programmable Terminal
Ladder program is created.
The addresses are set.
PLC
Programmable Terminal screens are created (graphics only).
NS-Runtime
Note: An EtherNet/IP connection is required.
For CJ2 Series, CX-Designer version 3.2 or later, and NS system version
8.4 or later are required.
For NJ5, CX-Designer version 3.3 or later, and NS system version 8.5 or
later are required. For NJ3, CX-Designer version 3.4 or later, and NS
system version 8.61 or later are required.Moreover, the multidimensional
array is supported in the combination with NJ.
FROM
CJ2/NJ
Maintenance
Case 1
Previously, the PLC program was first
created, and then the ladder program was
referenced to create the screens.
Addresses are allocated and the allocations are checked
Programming Tool
Definition of the "Motor" Symbol
Programmable Terminal
Drag
&
Drop
Programmable Terminal
Address
Ladder program is created.
Number_produced Undetermined
By simply setting tag names,
PLC and Programmable
Terminal programming can be
performed in parallel.
CJ2/NJ
Design time is shortene
…
Number_of_times Undetermined
…
TO
Tag name
Hand-held PT
Addresses are determined
while creating the ladder
program.
Specifications
The screens are created.
NS Series
The screens are created
with no need to pay
attention to addresses.
Features
Tag access
Design time is
shortened.
1. Tag names are managed at the PLC with the CX-Programmer.
A tag is a name given to an address. Tags are managed in
the CJ2 CPU Unit, where they are defined as network
symbols. The common user-defined tag names are used
from Programmable Terminals and host applications to
access memory in a CJ2 CPU Unit without knowing the
physical address.
Tag name
Number_produced
Address
D100
Minimize side effect of address changes
Network
2. For example, create screens with tag names without typing the physical address.
It is possible to access memory with tags, so the PT and
host application are not affected even if the address of
data in the PLC is changed.
Specific Example
No change required.
Host application
3. All devices will access with Common “Tag”
Number_produced
Tag name
Number_produced
Number_produced
Data links
Accessed by
tag name.
Address
Number_produced
System Configuration
Host application
1. With the CX-Programmer, the address for the tag named
“Number_produced” is changed from D100 to H200.
Number_produced
D100
Number_produced
Accessed using a tag.
Change
Number_produced
CJ2/NJ
14
No change
required.
CJ2/NJ
2. Applications and the PT are accessed using tags, and so
changes do not need to be made at other devices.
Even after the change, the number of items produced is
acquired correctly from H200.
Specifications
NS Series
H200
Ordering Information
CJ2/NJ
NS Series
15
Direct Connection to Temperature Controllers
Connect OMRON Temperature Controllers directly to the NS-series PT.
OMRON Temperature Controllers can be connected directly to the NS-series PT's RS-232C port.
Data does not pass through the PLC, so ladder programming is not required. Also, there are plenty
of objects in the SAP Library for Temperature Controllers, and Temperature Controller screens can
be created easily just by pasting objects from the SAP Library to the screens.
OMRON
Temperature
Controllers
Note: An RS-422A Serial Adapter is needed to connect directly to a Temperature Controller. Refer to page 53 for a list of the
Temperature Controllers that can be connected. A Conversion Unit is not required to connect to the RS-422A/485 serial
interface of the NS15.
OMRON
Temperature
Controllers
CJ1W-CIF11
RS-422A Serial Adapter
Face Plate Auto-Builder for NS
Screens for Loop Controllers can be easily and
automatically created.
CX-Process Tool
(Loop Controller Programming
Software)
Loop Controller program
creation (function block method)
CSV tag file output
Significantly reduces the effort required to combine a Loop Controller with an
NS-series PT.
Easy automatic generation of faceplates, such as faceplates for PV monitoring and SV
setting, as well as tuning screens, such as screens to set and autotune PID constants.
A total of 17 function blocks are supported, with eleven function blocks, such as Ratio
Setting and Motor Manipulators newly supported (version 3 of higher).
CSV tag file for
Loop Controller
NS project file
Comments are automatically entered for automatically assigned unit and scale settings
when a project is generated (version 3 and higher).
NS Series
Face Plate
Auto-Builder for NS
Created screens are easily
transferred to the NS by using a
Memory Card or over the network.
CX-Designer
SYSMAC CS/CJ-series Loop Controller
(NS screen creation software)
Editing created data
Creation of other required
screens
Note: Refer to the PLC-based Process Control Catalog (Cat. No. P051) and the Loop-control CPU Unit Catalog (Cat. No. R128) for details on Loop Controllers.
16
Design
Support 42 languages and switch the
language of the labels among up to
16 languages.
Startup/Operation
Multi-language Support
Multi-language CSV data
The labels' text attributes can
also be reflected when importing.
Maintenance
When screen data is imported, text
attributes can be applied to the
specified labels and attributes such
as the font and text color can be
reflected to other languages labels.
Unicode is supported and 42 Asian and European
languages can be combined in screens. Also, it is
possible to switch between up to 16 labels using the
label switching function, so it is possible to support up
to 16 languages in a single screen just by specifying
the language to be displayed in each label.
Import
NS-Runtime
NS Series
Support for
42 International
Languages
Hand-held PT
Thai Displays
Also Supported
Features
Multi-language conversion has
become much easier.
The screen data in the source language is exported to
a CSV file and sent to a translation agency by e-mail
for translation. Later, the translated CSV file is just
imported to easily provide multi-language support.
Language A screen data
Dual-language input in Excel
by translation companies and
local companies
CSV
Network
NS project
Language A
Excel data
Attachment
CSV
Dual-language screen data
Language A and B
Excel data
Attachment
System Configuration
NS project
CSV
CSV or
Unicode
text
Note: Windows XP (Service Pack3 or higher), Vista or 7 is required for multi-language support.
English system menu
(maintenance menu)
Chinese
French
Specifications
The system program of NS-series PTs supports
Chinese and European languages. All eight languages
are a standard feature, including Chinese (traditional
and simplified), Spanish, Italian, German, and French,
in addition to the previous Japanese and English.
Along with maintenance menus, messages for
communications errors, communications settings, and
screen transfers can be displayed in any of eight
languages. Maintenance can be performed in the
desired language. The language can be easily set
using the NS-series PT or screen data.
Ordering Information
Multi-language System Messages.
Eight Languages Supported as
Standard Feature
Italian
Multi-language messages for communications errors
17
Multiple functions
Multifunction execution with one object
Execute up to 32 functions with one Multifunction Object
Multifunction Objects support Write Bit, Write Word,
object control, and etc
Multifunction Objects combine the functions of multiple objects into one object.
Multiple functions can be executed by pressing one button without using
troublesome macros. Setup is easy. For example, a setting can be made
on-screen using the Support Software to turn ON a bit to start a machine, set a
value, and then change the screen.
Integration
Easy On-screen Setup with Support Software!
Execute multiple functions with one button.
Example:
The bit turns ON.
Touch
The word is set.
The screen changes.
Multifunction Objects support four useful functions
Switches that do not immediately operate when touched can be
easily made without ladder programming.
Time the button is pressed.
Time the button is not pressed.
ON delay
Turns ON when the button is pressed for at least a specified time.
Touch
ouch
Button pressed
Delay: 0.5 to 15 s
Relay status
Double-press
ON!
Turns ON when the button is pressed twice within the specified time.
Touch
ouch
Touch
Button pressed
Acceptance time: 0.5 to 30 s
Relay status
Simultaneous
pressing prohibited
OFF delay
ON!
Does not turn ON when the button is pressed at the same time as another button.
Turns OFF after a specified time lapses after the button is released.
Touch
ouch
Button pressed
Delay: 0.5 to 15 s
Relay status
18
OFF!
Design
Startup/Operation
Plentiful Graphing Functions
Data Log Graph (Trend Graph)
Up to 128 data can be collected in the cycle of
500ms. Logging data is stored as a CSV file in
the Memory Card inserted in the NS-series PT.
The log data files in the Memory Card
appear as shown below when the read
file button is pressed.
Maintenance
Logging data is stored as a CSV file in the Memory
Card mounted in the NS-series PT. The data stored
in the Memory Card can be read or deleted from
the screen.
NS-Runtime
Read file button
Suffixes are automatically added to file names set in the CX-Designer.
Memory Card
Automatically
saved
Logging data for each day
(43,200 points) is saved in
the Memory Card in CSV
format.
Hand-held PT
A log can be saved automatically, without any
programming, just by selecting the Save the data
periodically Option in the Data Log Setting Window.
LOG001.CSV 04/06/04 10:00
LOG002.CSV 04/06/05 10:00
LOG003.CSV 04/06/06 10:00
LOG004.CSV 04/06/07 10:00
LOG005.CSV 04/06/08 10:00
LOG006.CSV 04/06/09 10:00
LOG007.CSV 04/06/10 10:00
It is possible to make a
one-week log by automatically
saving the data seven times.
Features
Line Graph Function
(1) Graphs can be superimposed.
Network
The data logged by the PLC can be displayed in
overlapping graphs, so a device's operation
can be compared for evaluation and analysis.
In addition, up to 1,000 words of consecutive
data can be displayed as a line graph, data can
be displayed together, and any region can be
magnified.
System Configuration
(2) The display can be magnified.
Ordering Information
Continuous Line Function
Y
PLC
(X2, Y2)
D0000
X1
D0001
Y1
D0002
X2
Specifications
Any position from the host (PLC) can be plotted
as a graph. A graph can be plotted in any
position by specifying the X and Y coordinates
of the vertices. Also, the graph can be moved
on the screen by specifying the movements
from the PLC.
(X3, Y3)
(X1, Y1)
Y2
X3
Y3
X
Information in the PLC's format can be plotted
moment-by-moment.
19
Screen Data Security Functions
Security password
Protect important screen data with a
password.
A password between 4 and 64
characters long can be set. The
download/upload will start if the user
inputs the password that was set when
the screen was designed. (Password
input will be disabled if the wrong
password is input 3 times in a row.)
If password protection is set in the data transfer
security settings when the screen data is designed, a
password must be entered to download or upload the
screen data, so important screen data can be
protected.
Download
Upload
Download
Upload
If a password has been set, the password is required to transfer screen
data (download or upload) with the Memory Card.
Device Data Transfer
Multi-vendor Support
Easy Data Exchange between the PLC
and Components
For example, temperature controller alarm values can
be transferred to the DM Area of the PLC's CPU Unit.
No communications programming or macros are
required.
Multi-vendor Support
Temperature
controller
NS
PLC
SAP data can also be exchanged. SAP data can be
exchanged by checking the address of the SAP data
in the dialog box of the SAP object pasted in the
CX-Designer and specifying that address as the
transfer source address.
Note 1: EtherNet/IP tags are not supported.
Note 2: CX-Designer version 3.1 or higher is required.
NS system version 8.2 or higher is required.
20
DM0300
DM0302
DM0304
80
100
30
Modbus device
PLC from other
company
C10004
C10005
C10006
80 Alarm value 1
100 Alarm upper limit value 1
30 Alarm lower limit value 1
Temperature
controller
Easy Settings
Easier Operation when Combining
SAP Library Objects
80
100
30
Easy Settings
Devices from multiple vendors are supported.
Data can be easily exchanged with PLCs from other
companies and Modbus devices.
To make the settings, simply specify the device and
addresses of the transfer source and transfer
destination in the CX-Designer. Settings can be made
using the same procedure as for setting the
addresses for normal components.
C10004
C10005
C10006
DM0300
DM0302
DM0304
NS
80
100
30
PLC
CX-Designer Select Device Data Transfer Setting from the PT Menu.
Make the settings simply
by specifying the
addresses of the transfer
source and transfer
destination as well as the
number of data items.
Design
NEW
Easy Reading from Palette
Startup/Operation
NS Screen Templates
The CX-Designer of version 3.5 or higher provides the palette to display
objects and templates (scheduled for auto update in August 2012). Refer
to the next page for details of the palette.
Even Simpler
Maintenance
Templates can be read into the screen by just dragging and
dropping thumbnails displayed on the palette.
Drag
&
Drop
The template consisting of multiple screens allows multiple
screens to be read by dragging and dropping it once.
NS-Runtime
The Address Setting Dialog Box that is displayed to read
templates is useful for changing addresses all at once.
Palette
Address Setting Dialog Box
The refined templates enable you to use the NS Series with
the screens that have a sense of unity in design.
Hand-held PT
Even More Beautiful
POP (default)
Features
Three different types of templates besides default screens
are provided. The design can be changed easily with
"Theme Name" that is displayed when dragging and
dropping.
CLEAN
METAL
NATURAL
Network
System Configuration
“Cool” Objects
Aluminum
Backgrounds, buttons, labels, message boxes, and
other objects are also provided for various themes.
Metal
Ordering Information
Game
Lighting
Specifications
Dot
Metalplate
Water
21
Screen Designer for NS Series, CX-Designer
User-friendly Screen Creation
Without screen creation and ladder programming, the CX-Designer Screen Design Software is so
easy-to-use that anyone can master it. Quickly create the required screen by dragging and
dropping objects. OMRON’ s unified development environment lets you drastically reduce the work
required to create screens.
Note: The same type of Project Workspace and Output Window as in the CX-Programmer are provided for the user interface.
All addresses and comments can be managed using a single Symbol Table.
Shows a list of addresses, names, and comments used in project screen data. Addresses, names,
and I/O comments for the CX-Programmer can also be imported.
Improved Icons
and Help
The project Workspace enables the user
to look through the entire project.
Screens you want to edit can be opened right
away.
Perform screen management, such as copying
or deleting screens, by simply right-clicking.
Reusing screens from other projects is easy with
the CX-Designer.
Settings for alarms, data logs, communications,
and other functions can be easily accessed.
22
Objects and templates can be
selected easily from the palette. NEW
Easy-to-use, well-designed, and super-beautiful
objects and templates can be read into the
screen by dragging and dropping. Templates can
be chosen from four different designs.
Drastically reduce
the number of clicks in the project.
The Output Window
shows search results.
Just click on the object once to display or
change properties. Multiple objects can be
selected to display and change shared
properties all at once.
In addition to addresses and I/O
comments used in screen data,
labels can also be used as
search strings and the results
can be displayed.
Design
NEW
Startup/Operation
Palette
Switches, lamps, and templates are registered in the palette.
Just drag and drop them on the new or existing screen to add.
Note. CX-Designer version 3.5 or higher is required.
Maintenance
Import
The Import button allows new objects and templates to be
added to the palette.
The palette appears on the
right side of the screen when
starting the CX-Designer.
NS-Runtime
Library and Template
tabs at the bottom left of
the palette
Palette
Library
Parts list of switches and lamps is displayed.
Hand-held PT
Template
Templates are displayed in thumbnailed form.
Library
Color Setting
Features
Switches and lamps are registered in the
library. Select a switch, lamp, or other
object from the pull-down menu. You can
register switches you created or other
objects you often use in "User-defined".
Display colors of objects registered in the library can be changed
easily by selecting colors from pull-down menus.
Network
Change display
color to blue.
A template consists of multiple screens. Multiple screens are pasted
on the screen by dragging and dropping a thumbnail on the screen.
Ordering Information
Templates include design templates and
device templates.
System Configuration
Template
•Design Template
Design templates are the screen templates
designed professionally. Addresses can be
changed with "Address Setting Dialog Box".
As well as SAP (Smart Active Parts),
addresses on the screen are automatically
updated by changing unit number of
Temperature Controller or Special I/O Unit
with "Unit No Dialog Box".
Specifications
•Device Template
Drag
&
Drop
23
Reading Another Project's Screens
and Objects
Resources from another project can be easily reused
by just selecting the screen or objects that you want
to read and dragging and dropping it, so screens can
be created intuitively.
Example screen 1
Select the screen that you want to read,
drag it to the destination, and drop it.
Example screen 2
Select the part that you want to read,
drag it to the destination, and drop it.
Project B
Project B
Project A
Project A
Drag
&
Drop
Drag
&
Drop
Reading CAD Files
It is possible to import DXF files by dragging and
dropping them. The files are read as a diagram, and
so less capacity is used than with images. It is also
easy to customize the diagram by changing the shape
or color.
CX-One Version 2.0 on computer
The screen data and ladder program
can be checked simultaneously
in the computer.
The CX-Designer and CX-Programmer interconnects
the test functions in the computer through the
CX-Simulator. The screens and ladder program
checks are performed simultaneously, which
significantly increases debugging
efficiency. The CX-Programmer also has a new button
for integrated simulation. And, work efficiency is
further improved with the ability to keep required
work screens pinned on front and to zoom in or out
as desired.
Ladder Program
Prog
el
Touch Panel
Interactive
Ladder Program Window
Touch Panel Screen
Interactive
24
Design
CX-Programmer's
symbol table
Maintenance
The symbol table created in the CX-Programmer
during ladder programming can be read into the
CX-Designer by dragging and dropping, so it isn't
necessary to manually data such as input addresses
and I/O comments. Tags (i.e., network symbols) can
also be read into the CX-Designer.
Startup/Operation
Reading the Symbol Table
Note: Version 8.0 or higher of the CX-Programmer support tags
(i.e., network symbols).
CX-Designer's
symbol table
NS-Runtime
Drag
&
Drop
The CX-Programmer's
symbol table can be
dragged and dropped!
Hand-held PT
Example of Reading the Symbol Table
The symbol table read from the CX-Programmer can
be directly dragged and dropped to the touch switch
and lamp.
Example of Easy Address Allocation
(2) Check the comment then drag-and-drop the symbol from the symbol table to the property list.
Features
(1) Create a switch on the screen.
Drag
&
Drop
Network
(3) Allocations for buttons and
lamps can also be checked on
the screen using comments
imported from the
CX-Programmer.
System Configuration
Example of Reading I/O Comments
Ordering Information
If Use I/O comment is selected in advance for the Use
symbol text as label, the I/O comments are automatically used as labels when addresses are dragged
and dropped from the symbol table. (If Use symbol
names is selected, the symbol names are used as the
labels.)
Drag
&
Drop
Specifications
The I/O comment is used as the label.
25
260,000-color Video Display
Equipment and workpiece movements
can also be displayed in beautiful video
NS-CA001 Video Input Unit
Four video inputs or CCD cameras can be connected
and up to four images can be displayed simultaneously
if the image size is 320x240 pixels. The NS-CA001
cannot be used with the NS5 or the NS15.
NS-CA002 RGB/Video Input Unit
There is an analog RGB input terminal in addition to the
two video input terminals. Either of the video signals or
the analog RGB signal can be displayed on the
NS-series PT. The NS-CA002 cannot be used with the
NS5.
Note: Video input cannot be used with the NS15.
Only RGB input can be used.
Also Compatible with OMRON Vision Sensors.
Analog RGB Output
The NS screen is seen by
another monitor.
The NS15 screen (XGA) can be displayed on an on-site
display that has RGB inputs.
Note: Only NS15
26
Console
Camera
RGB
Console
Camera
Design
Startup/Operation
FTP Function
You can partially replace text and
pictures from your computer.
Maintenance
FTP (File Transfer Protocol) has been added! Texts,
lists, and recipes can be replaced with the put/get
command from your computer! You can even replace
BMP files from your computer easily.
Screens, bitmaps, text, recipe data
NS-Runtime
Hand-held PT
Low
User Security Functions
Level 1
Level 2
Level 3
High
Level 4
Level 5
Network
Each operator can be given one of 5 password levels
using the User Security (level authentication) function.
A password level can be set for each object, so
various objects can be made inoperable or hidden
based on the operator's access level.
Features
Operator access rights and the
operating format can be set to one of
five password levels.
Operator passwords are
managed in 5 levels.
Passwords can be up to 16
characters long and the
access rights increase as the
level number increases.
The operator cannot manipulate objects with
a password level (authentication level) higher
than the operator's login level.
System Configuration
NS with LED backlight
Conventional three-level adjustment
* LotNo.15Z0 or later of NS5 color-type models, LotNo.28X1 or later of
NS8 models, LotNo.11Y1 or later of NS10 models, LotNo.14Z1 or later
of NS12 models, LotNo.31114K or later of NS15 models.
New 32-level adjustment
Specifications
LED backlight allows backlight brightness adjustment
of up to 32 levels. The brightness can be adjusted
from the operation screens, and the RUN indicator
changes its luminance according to the settings of the
backlight brightness; it is favorable for ship and vessel
applications.
Ordering Information
NS5 color-type models (SQ/TQ models),
NS8 models, NS10 models, NS12 models,
NS15 models with LED backlight are
newly released. *
27
Comparison
NEW
The on-site NS screen can be compared with the computer screen.
Same
Different
Added
Deleted
The comparison function of the CX-Designer enables the following comparison.
CX-Designer project
Project in the computer
CX-Designer project
NS project
Same in screen
Different in screen
Screen added
Screen deleted
PT Transfer Compare
Comparison
Comparison
result
Single Port Multi Access (SPMA)
Note: Communications across network layers can be performed.
Keep connected.
CX-Programmer
Serial connection
(1: N NT Link only)
Ethernet
Controller Link
USB or
Ethernet
Transfer ladder program data to the PLC via
the PT. Perform online editing via the PT.
Computer (Serial)
PLC (Ethernet or Controller Link)
PLC
Ladder program
Computer (Serial/USB) NS-series PT (Ethernet)
PLC (Ethernet or Controller Link) PLC
Transfer screen data via the PLC.
The ladder program can be transferred.
NS
Ladder program
Keep connected.
CX-Designer
NS-series PT
Ethernet or Controller Link
The ladder program can be transferred.
USB/Serial or
Ethernet (See note.)
PLC
NS
Serial
Screen data
Screen data
Ethernet or Controller Link
Note: USB connection is
supported only for CJ2 PLCs.
Using a USB relay cable greatly improves
debugging at equipment startup.
Use a USB relay cable to enable performing
maintenance from in front of the control panel.
Screen data
CX-Programmer
CX-Designer
USB relay cable
(IP65 oil-proof type)
(sold separately:
NS-USBEXT-1M) NS
Easy Automatic Connection
A search is automatically made for the PLCs
connected to the PT and the results are displayed
using the automatic online connection function in the
CX-Programmer. Just select a PLC from the list to
connect. This function is also supported for PLCs over
network layers.
Commercially
available USB
cable
CX-Programmer
28
Note 1: SPMA can be used in CS/CJ-series PLCs with lot number
030201 or later.
Note 2: SPMA via a PLC is not supported when a CP-series PLC is
connected. (SPMA via an NS-series PT is supported with a
CP-series PLC.)
Note 3: CX-Programmer version 8.2 and higher support automatic
online connection via the PT. NS system version 8.2 or higher is
required.
Automatic
search
PLCs registered to the PT are automatically searched for.
Make the connection simply by selecting from the PLC list.
Design
Startup/Operation
PLC Data Trace
The PLC data trace function can be
used without a computer.
Maintenance
The PLC Data Trace function is built into the PT in
addition to the Ladder Monitor and Device Monitor. A
bit's status and operation can be viewed in a time
chart just by setting the desired PLC bit's address in
the PT. It is also now possible to display word data,
save data in CSV files, and save time chart screens in
BMP files.
NS-Runtime
Note 1: There are differences between this Data Trace function and the
CX-Programmer's Data Trace function. Refer to the NS-series
Programmable Terminal Programming Manual (Cat. No. V073) for
details.
Note 2: The PLC data trace function cannot be used with the 5.7-inch
model.
Note 3: The PLC data trace function is not supported for connection with a
CP1E PLC.
Data Trace
CS/CJ/CP-series PLC
Hand-held PT
Operating log
What Was Touched When? can be recorded.
Features
Functionality has been improved with the addition of a log to record operators’ use of the panels. It
is now possible to record and display the time, date, and operation details for buttons (i.e.,
hardware switches) pressed on the control panel in addition to operations on the touch panel. The
operation log can be saved in a CSV file on a Memory Card mounted in the NS-series PT.
Network
Multiple operation log
files can be saved on a
Memory Card with date
and time data.
System Configuration
Memory Card
Operat_080520_
173000.csv
Ordering Information
Operat_080521_
173000.csv
Operat_080522_
173000.csv
Switch directly from
m the user screen
to the log operationn display screen.
A comment of up to 32 characters can be set and displayed
for each operation to provide easy-to-understand information
about what type of operation was performed.
The files can be opened in Excel.
Specifications
For example, with a control panel comprised
of the NS-series PT, hardware switches, and
an emergency
stop button, you can even record and display
operation of the emergency stop button.
29
Ladder Monitor
The ladder program can be monitored
without a computer.
Ladder programs with I/O comments can be
monitored on the PT's screen and the ladder program
can also be edited with the Programming Console
function.
Operation screen
CS/CJ/CP-series PLC
Also meets the requirements of users
who need to display devices onsite
Switch Box Function
Device Monitor Function
Switch Box Function
The operator can check the PLC status by displaying just
the I/O comments and status.
Device Monitor Function
Displays the device's contents, allowing settings to be input
and checked and making startup operations more efficient.
so no extra work to show I/O
comments
Select Read I/O Comment
Reading from the Menu.
The I/O comments
are displayed.
Read I/O comments directly from the PLC. I/O
comments do not have to be stored in a Memory
Card.
Easy checking the alarm bit and
shortens searching time.
ALARM
When an alarm occurs, touch the message to
automatically search for the alarm bit (output bit) for
the alarm. This enables you to quickly check the
alarm address and investigate why the bit turned ON.
Found it!
30
Design
Startup/Operation
“Find Back”, “Find Next”, useful Function Supported by the NS-series.
Reduced Time to Investigate Which Output or Input Is Causing the Problem.
Function
Operationn with NS-series PT.
CX-Programmer
Find the address at specified by the cursor.
Next
“N” Key
uble-cliick
Double-click
Return to the previous search position.
Maintenance
Find the output from the input bit or find the
input bit from the output at the cursor.
“Space” Key
“B” Key
Backk
NS-Runtime
1.Why is this output
not turning ON?
2.Is this input the cause?
What output corresponds
to this input?
4.Which of these two
inputs is the cause? Let’s
look at CIO 21.00 first.
3.Why is this
output not turning ON?
Hand-held PT
5.There’s no problem
with input CIO 21.00.
Let’s go back to the
previous program section.
Features
6.So is it input CIO
21.01 after all?
Back
Yes, the
problem
is here!
Locations that have been force-set are displayed in pink and can be checked at a
glance.
2. Select the address
by touching the panel.
1.Select the input bit for which the output will be forced ON.
Network
Force-setting and force-resetting are possible
3. Select the Forced Set Option and
then press the Update Button.
Change
System Configuration
4. Forced ON
Minor changes in values of timers or counters can be made without Support Software.
Ordering Information
Check and Change I/O While You View the Ladder Diagram on the I/O Monitor
Display and change the present value by specifying the address. It is also possible
to force-set/reset bits with the I/O monitor.
Specifications
Make the selection with
the I/O monitor by touching
the screen.
Changing the present value
of the address selected with
the Change Value Button
Note: The Ladder Monitor function is not supported by the 5.7-inch models.
31
NS-Runtime
NS-NSRCL (NS-Runtime)
Achieve machine/line monitoring and data logging on
your office computer.
Machine Viewer
Displaying Maintenance
Information (PDF File)
Monitoring Device Alarms
Machine monitoring in an office environment.
There is no need to create complex host applications.
Moreover, when an alarm occurs, a PDF file can be
displayed as maintenance information. NS Series
screens can be reused on the computer, and screens
can be also newly created independently of touch
panels at the production site.
To Maintenance screen
Ethernet
Wide Screen
MAX 3840pixel
Computer output can be displayed on another
wide-screen monitor. XGA (1,024 x 768 dots) and up
to a a maximum screen size of 3,840 x 2,400 is
supported. Alarms occurring in devices or the line can
be monitored.
MAX
2400pixel
Monitor output
Note: The resolution that can be displayed depends
on the computer. An input function for
displaying the computer screen is required at
the display monitor.
Data Logger
Log large amounts of data using a personal
computer. Data can be logged through background
processing, with up to 160,000 points stored in one
file. The logged data is stored in CSV format, and
data can be displayed on data log graphs.
CSV
format
Stored Data
Example: 160,000 Points
Data can be logged for approximately 7.4 days, assuming data is logged every two seconds for 12 hours a
day. By using automatic file saving, data logging can be continued even longer than 7.4 days.
32
Design
Startup/Operation
Recipe Handling
Maintenance
NS-Runtime
Checking machine data or switching processes from
a host computer is easy. Parameter groups in the PLC
can be transferred together to a computer, and the
transferred data can be checked and edited in CSV
format, e.g., using Excel. The edited data can then be
transferred together back to the PLC.
CSV
format
Hand-held PT
Recipe data
Easy Installation
NS-Runtime
Screen Data
Features
To get started, just install the NS-Runtime in the
computer and place the screen data in the applicable
folder. NS/NSJ-series screens and NS-Runtime
screens can all be managed using one single tool.
Note: The NS-Runtime will operate in a computer environment even if the
CX-Designer installed is not installed. The hardware key (USB
dongle) that is supplied with the NS-Runtime is required for
operation.
Application Startup Function
Network
To PLC
Screen designer: CX-Designer (CX-One)
NS-Runtime
System Configuration
User applications can be started from NS-Runtime.
Applications can be started simply by pressing
buttons on the screen.
Started
ted
Ordering Information
For example, to start an
application by pressing a button…
Use the EXEC( ) macro.
Example: EXEC("C:ProgramFiles\Micros..\EXCEL.EXEC:\..\
TEST2.xls…..);
Note: As much as possible, keep applications closed that are
not required for operation.
User application
on
Specifications
Note 1: If the screen data is converted for the NS Series, NS-Series PT system versions must be 8.1 or earlier. The screen data of system version 8.2 can not be converted for the NS-Runtime.
Note 2: Do not use this product for 24-hour operation in an FA environment. OMRON shall not be responsible if the computer or application does not operate properly due to noise or other causes.
OMRON shall not be responsible for any problems that may be caused by any applications other than OMRON products.
33
NSH5 Series
A hand-held version of the NS5 is now available to perform operations at the production site. The
NS-series PT's have a complete set of functions that can be used at the production site, such as
the SAP Library, multi-language support, and Programming Console functions.
Function Switches
Use the ten functions
switches.
F1, F2, F6, F7: Wired outputs
F3 to F5, F8 to F10:
Communications outputs
Memory Card Interface and
USB Slave Connector.
Easily transfer screens or save logs at high
speed using a USB connection.
Emergency Stop Switch.
3PST-NC Structure
DPST-NC: Increase safety (wired outputs).
SPST-NC: Input to internal NSH5 memory,
output to a lamp for emergency stop switch
operation, or output via communications,
e.g., to a PLC.
Water Resistance to IP65
The water-resistant structure is equivalent
to IP65 on all surfaces. The PT may not be
suitable for use in environments with
long-term water exposure.
3-Position
Enable Switch
Increased safety with
DPST-NO structure (wired
outputs).
Precautions for Emergency
Stop Switches
When using a hand-held NSH5 that will be installed
and removed from a control panel or Removable Box,
always use the specified Stop Switch
(Gray/NSH5-SQG10B-V2) to conform to Safety
Standards (EN 60204-1).
Options
Removable Box
A separate external circuit is not required because the
Removable Box has been configured so that the
emergency stop switch line will not turn OFF (i.e., so that
the emergency stop circuit will operate) even when the
NSH5 is removed.
Visor
Use when the NSH5 is in direct sunlight.
Mounting Bracket
Use to attach the NSH5 to a control panel.
34
PT and Cable Sold Separately
Select the Cable according to the
application (RS-232C/RS-422A).
Connector-loose wires,
UL connector,
3 m or 10 m.
Programmable Terminals
NS Series
Even Simpler Equipment Operation with Outstanding Synergy.
5.7 inches
10.4 inches
15 inches
12.1 inches
8.4 inches
Color TFT
Color TFT
Color TFT
Color TFT
Color TFT
STN monochrome
Features
• 5.7 to 12.1 inch sizes are available.
• A hand-held version of the NS5 is now available to perform operations at the production site. The NS-series PT's
have a complete set of functions that can be used at the production site.
• The Smart Active Parts(SAP Library) makes it easy to connect to OMRON PLCs and components,
OMRON provides a development environment that requires with no programming and no screen designing.
• When an error occurs in a Unit in the OMRON PLCs, the Troubleshooter SAP Library provides an easy-tounderstand explanation of the cause of the error as well as the countermeasures.
• Ladder Monitor come as a Standard Feature. The ladder program can be monitored onsite without a laptop!
Ladder monitor lets you monitor PLC program status, search for addresses or instructions, monitor multiple I/O
points, and much more.
• Provides the FA integrated tool package "CX-One" for a Screen Design Software Integrated Simulation come as a
Standard Feature. The integrated simulation function simulates ladder programs and screen data simultaneously
even without the actual hardware.
• Screens support 42 languages and the Support Software supports eight. System messages can be displayed in
eight languages.
• Single Port Multi Access (SPMA) come as a Standard Feature. The ladder program and screen data can be
transferred from a single port!
• Connectable PLCs and devices appear one after another.
Has become connectable with the PLCs of Mitsubishi Electric Corporation and the Inverters of OMRON
Corporation.
Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products.
Windows is registered trademarks of Microsoft Corporation in the USA and other countries.
EtherCAT is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.
1
NS Series
Network
Provides serial NT Link communications supporting both 1:1 and 1:N connections. The NT Link has more efficient communications than Host Link
and its capabilities are especially apparent in applications with multiple PTs connect to the PLC. The NS-series PTs can also support
communications with multiple PLCs and multiple NS-series PTs through Controller Link and Ethernet connections, so the network can be
configured freely to match the requirements and scale of the application. In addition, using the NS-Runtime makes it possible to monitor machine
status and log data from the host.
Software for Machine Monitoring and
Data Logging
[Example NS-series Network
Configuration]
1
EtherNet/IP (Tag access)
4
(sold separately)
Personal computer
EtherNet/IP, Ethernet
CS/CJ-series
PLC
3
Controller Link
NS-series PT
2 Serial connection
5 Connections
across network
levels
NS-series PT
CS/CJ-series PLC
NS-series PT
NS-series PT
2 Serial
CS/CJ-series
PLC
CS/CJ-series
PLC
connection
Configuration of CJ2 series, NJ series and NX series
1 EtherNet/IP Connection (Tag accesses)
If an Ethernet-compatible NS-series PT is used, the PT can connect to a Controller with built-in EtherNet/IP and an Option Unit is not needed to
connect at the PT.
NS-series PT
Personal computer
Controller
2
Controller
NS-series PT
Controller
NS Series
Configuration of CS series, CJ series and CP series
2 Serial connection
1:1 NT Link or Host Link
NS:PLC = 1:1
NS:PLC = 1:2
Connecting with the PLC through port A or port B
NS-series PT
NS-series PT
PLC
PLC
PLC
1:N NT Link
NS:PLC ratio = 8:1 max. Up to 8 NS-series PTs can be connected to each of the PLC's RS-232C/RS-422A ports.
NS-series
PT
NS-series
PT
NS-series
PT
PLC
NS-AL002 Converter
(Converts between
RS-232C and RS-422A.)
3 Controller Link Connection
The PT can be connected to an OMRON Controller Link network by mounting a Controller Link Interface Unit.
NS-CLK21
NS Series
PT
If a Controller Link connection
is used, data links can be set
between PLCs and multiple
PLCs can be monitored/set
from the NS-series PT's screen.
PLC
PLC
PLC
Baud rate
2 Mbps (500 m max.)
1 Mbps (800 m max.)
500 kbps (1 km max.)
Max. number of nodes: 32 nodes
4 EtherNet/IP or Ethernet Connection
If an Ethernet-compatible NS-series PT is used, the PT can connect to a PLC with an Ethernet Unit and an Option Unit is not needed to connect at the PT.
NS Series PT
Personal computer
PLC
PLC
NS Series PT
PLC
5 Connections Over Network Levels
The NS-series PTs can connect to a variety of devices in the network, through as many as 3 network levels.
For example, if SAP (Smart Active Parts) are being used, an NS-series PT connected by Ethernet can be used to monitor the information in a PLC
connected through Controller Link as well as the information in the DeviceNet Slaves connected to that PLC.
NS Series
PT
NS Series
PT
Ethernet
PLC
Seamless and
Program-less
Seamless and
Program-less
Controller Link
PLC
PLC
DeviceNet
3
NS Series
System Configuration
NS5/NS8/NS10/NS12/NS15
OMRON
Memory Card
Memory Card
Interface
Ethernet
port
USB
Slave
RS-422A Conversion Unit
CJ1W-CIF11
NS-AL002
Note: A Conversion Unit is not required to connect to the RS-422A/485 serial
interface of the NS15.
USB RS-232C RS-232C
Master
port
port
OMRON PLC
PT-to-PLC Connecting Cable
XW2Z-200T (Length: 2 m)
XW2Z-500T (Length: 5 m)
RS-232C
Bar Code Reader
Recommended: OMRON
V520-RH21-6
Screen transfer cable
XW2Z-S002 (Length: 2 m)
Screen transfer cable
XW2Z-S002 (Length: 2 m)
RS-232C
USB Serial Conversion Cable
CS1W-CIF31
USB
Personal computer
Memory link connection
Micro-computer board,
personal computer, etc.
CompoWay/F connection
Temperature
Controller
Modbus (MEMOBUS)-RTU connection
RS-422A
OMRON
PLC
Inverter
Standard USB cable
Commercially available.
Standard USB cable
Commercially available.
Standard USB cable
Commercially available.
PictBridge
PictBridge-compatible printer
USB
Personal computer
Wireless
WE70
USB
WE70
Ethernet
OMRON
PLC
Ethernet
OMRON
PLC
EtherNet / IP
OMRON
Controller
Ethernet
Personal computer
4
NS Series
Expansion Bus Interface
Any one of the following Units can be mounted to
the expansion bus interface.
Controller Link Interface Unit
NS-CLK21
Video Input Unit
NS-CA001
RGB/Video Input Unit
NS-CA002
Expansion bus
interface
Controller Link
PLC
NTSC/PAL
Vision
Sensor
NTSC/PAL
RGB output
Note: Video Input Units and RGB Video Input Units cannot be used with some models.
Personal computer
Multi-vendor
Computer Link Unit
Mitsubishi A-series PLC
Function Extension Board or Mitsubishi
FX-series PLC Communications Adapter
Mitsubishi FX-series PLC
Serial Communications Unit
Mitsubishi QnA-series PLC
Serial Communications Unit
RS-232C
port
RS-232C
port
Mitsubishi Q-series PLC
RS-232C
Computer Link Module
Yokogawa’s FA-M3(R) Series
SIMATIC S7 HMI Adapter
Siemens S7-300-series PLC
RS-422A
Conversion Unit
CJ1W-CIF11
NS-AL002
Note: A Conversion Unit
is not required to
connect to the
RS-422A/485
serial interface of
the NS15.
RS-422A/485 (See note.)
Serial Communications Module
Screen transfer cable
XW2Z-S002 (Length: 2 m)
Yaskawa MP-series PLC
Rockwell (Allen-Bradley)
SLC500/Micrologix/ControlLogix/
CompactLogix/PLC-5-series PLC
Modbus device (RTU mode)
Computer Link Unit
Mitsubishi A-series PLC
Function Extension Board or Mitsubishi
FX-series PLC Communications Adapter
Mitsubishi FX-series PLC
Serial Communications Unit
Mitsubishi QnA-series PLC
Serial Communications Unit
Mitsubishi Q-series PLC
Computer Link Module
Yokogawa’s FA-M3(R) Series
Serial Communications Module
Yaskawa MP-series PLC
Rockwell (Allen-Bradley)
PLC-5-series PLC
Modbus device (RTU mode)
Note: Whether an RS-422A or RS-485 connection is supported depends on the device that you are connecting to.
For details, refer to the Connectable Devices page or NS-Series Programmable Terminals HOST CONNECTION MANUAL Multivendor
Connection (Cat.V092).
5
NS Series
NSH5 Hand-held PT
USB
Commercially available USB cable.
USB Slave
Memory
Card interface
OMRON
Memory Card
NSH5 PT
RS-232C
cable
RS-422A
cable
RS-232C
cable
UL-listed Cables
RS-422A
cable
RS-232C Connecting Cable for the NSH5
NSH5-232CW-3M (Length: 3 m)
RS-232C
PLC
RS-422A
PLC
RS-232C
PLC
RS-232C Connecting Cable for the NSH5
NSH5-232CW-10M (Length: 10 m)
RS-422A Connecting Cable for the NSH5
NSH5-422CW-10M (Length: 10 m)
RS-232C Connecting Cable for the NSH5
NSH5-232UL-3M (Length: 3 m)
RS-232C Connecting Cable for the NSH5
NSH5-232UL-10M (Length: 10 m)
RS-422A Connecting Cable for the NSH5
NSH5-422UL-10M (Length: 10 m)
PLC
RS-422A
USB
Commercially available USB cable.
USB Slave
Personal computer
Memory
Card interface
OMRON
Memory Card
NSH5 PT
Personal computer
Removable Box Connected
RS-232C
cable
Removable Box
RS-232C Connecting Cable for the NSH5
NSH5-232CN-3M (Length: 3 m)
RS-422A
PLC
RS-232C Connecting Cable for the NSH5
NSH5-232CN-10M (Length: 10 m)
System Configuration
(Removable Box Connected)
Up to eight NSH5s can be
connected at a time.
NSH5 (See note.)
PLC
RS-232C connection
(Cable length: 3 or 10 m)
Removable
Box
Control panel
RS-422A connection (Total cable length: 500 m max.)
Up to 15 Removable Boxes
can be connected.
Note: Before removing the NSH5 from the Removable Box,
be sure to first turn OFF the power supply key on the Removable Box.
6
NS Series
Ordering Information
International Standards
• The standards are availabled as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus
(Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
• Contact your OMRON representative for further details and applicable conditions for these standards.
Programmable Terminals
Product name
Specifications
Effective display area
Number of dots
Ethernet
No
5.7-inch *2
TFT color
LED backlight
Yes
320 × 240 dots
NS5-V2 *1
5.7-inch *2
High-luminance
TFT color
LED backlight
8.4-inch *2
TFT
LED backlight
NS8-V2
10.4-inch *2
TFT
LED backlight
NS10-V2
12.1-inch *2
TFT
LED backlight
NS12-V2
15-inch
TFT
NS15-V2
NSH5-V2 *1
Hand-held
5.7-inch
TFT
No
Yes
No
640 × 480 dots
Yes
No
640 × 480 dots
Yes
No
800 × 600 dots
Yes
1,024 × 768 dots
320 × 240 dots
Yes
No
Model
Case color
Ivory
NS5-SQ10-V2
Black
NS5-SQ10B-V2
Ivory
NS5-SQ11-V2
Black
NS5-SQ11B-V2
Ivory
NS5-TQ10-V2
Black
NS5-TQ10B-V2
Ivory
NS5-TQ11-V2
Black
NS5-TQ11B-V2
Ivory
NS8-TV00-V2
Black
NS8-TV00B-V2
Ivory
NS8-TV01-V2
Black
NS8-TV01B-V2
Ivory
NS10-TV00-V2
Black
NS10-TV00B-V2
Ivory
NS10-TV01-V2
Black
NS10-TV01B-V2
Ivory
NS12-TS00-V2
Black
NS12-TS00B-V2
Ivory
NS12-TS01-V2
Black
NS12-TS01B-V2
Silver
NS15-TX01S-V2
Black
NS15-TX01B-V2
Black (Emergency stop
button: Red)
NSH5-SQR10B-V2
Black
(Stop button: Gray)
NSH5-SQG10B-V2
Standards
UC1, CE,
N, L,
UL Type4
UC1, CE,
N, L
UC1, CE,
N, L,
UL Type4
UC, CE
*1. As of July 2008, the image memory has been increased to 60 MB.
*2. Lot No. 15Z0 or later of NS5 color-type models, Lot No. 28X1 or later of NS8 models, Lot No. 11Y1 or later of NS10 models, Lot No. 14Z1 or
later of NS12 models, LotNo.31114K or later of NS15 models.
NS-Runtime
Product name
Specifications
Media
1license
NS-Runtime
NS-Runtime Installer, PDF manual, hardware key (See note.)
3 licenses
10 licenses
Model
Standards
NS-NSRCL1
CD
NS-NSRCL3
---
NS-NSRCL10
Note: A hardware key (USB dongle) is required for NS-Runtime operation.
●System Requirements
Item
Specifications
OS
Windows XP (Service Pack 3 or higher), Vista, 7 or 8 (Support 64-bit version for Windows 7 and Windows 8.)
CPU
Celeron, 1.3 GHz or higher (Recommended)
Memory size
HDD: 50 MB min., RAM: 512 MB min. (Windows 7: 1 GB min.).
50 MB is required for the Runtime alone. (An additional 280 MB is required if CX-Server is not already installed.)
7
NS Series
Software
●How to Select Required Support Software for Your Controller
The required Support Software depends on the Controller to connect. Please check the following table when purchasing the Support Software.
Item
Omron PLC System
Omron Machine Automation Controller System
Controller
CS, CJ, CP, and other series
NJ-series and NX-series
Programmable Terminals
NS-series
NS-series with an Ethernet port
Software
FA Integrated Tool Package CX-One
Automation Software Sysmac Studio
●FA Integrated Tool Package CX-One
Product name
Specifications
Number of
licenses
Media
1 license *
DVD
Model
Standards
CXONE-AL01D-V4
---
The CX-One is a comprehensive software package that integrates Support
Software for OMRON PLCs and components.
FA Integrated
Tool Package
CX-One Ver.4.@
CX-One runs on the following OS.
Windows XP (Service Pack 3 or higher, 32-bit version) / Windows Vista (32-bit/
64-bit version) / Windows 7 (32-bit/64-bit version) / Windows 8 (32-bit/64-bit
version) / Windows 8.1 (32-bit/64-bit version) / Windows 10 (32-bit/64-bit
version)
CX-One Version 4.@ includes CX-Designer Ver.3.@.
For details, refer to the CX-One catalog (Cat. No. R134)
* Multi licenses (3, 10, 30, or 50 licenses) and DVD media without licenses are also available for the CX-One.
●Automation Software Sysmac Studio
Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available
individually. Each model of licenses does not include any DVD.
Specifications
Product name
The Sysmac Studio provides an integrated development environment to set up,
program, debug, and maintain NJ/NX Series Controllers and other Machine
Automation Controllers, as well as EtherCAT slaves.
Sysmac Studio
Standard Edition
Ver.1.@
Model
Standards
Number of
licenses
Media
- (Media only)
DVD
SYSMAC-SE200D
---
1 license *
---
SYSMAC-SE201L
---
Sysmac Studio runs on the following OS.
Windows XP (Service Pack 3 or higher, 32-bit version) / Windows Vista (32-bit
version) / Windows 7 (32-bit/64-bit version) / Windows 8 (32-bit/64-bit version) /
Windows 8.1 (32-bit/64-bit version) / Windows 10 (32-bit/64-bit version)
The Sysmac Studio Standard Edition DVD includes Support Software to set up
EtherNet/IP Units, DeviceNet slaves, Serial Communications Units, and
Support Software for creating screens on HMIs (CX-Designer).
For details, refer to the Sysmac Integrated Catalogue (P072).
Note: To connect the NJ5 Controller, NS system version 8.5 or higher is required. CX-Designer version 3.3 or higher is also required.
To connect the NJ1/NJ3 Controller, NS system version 8.61 or higher is required. CX-Designer version 3.4 or higher is also required.
To connect the NX7 Controller, NS system version 8.9 or higher is required. CX-Designer version 3.64 or higher is also required.
* Multi licenses are available for the Sysmac Studio (3, 10, 30, or 50 licenses).
8
NS Series
Cable
Product name
Cable *1
NSH5 Cables
UL-compliant
NSH5 Cable
PT-to-PLC
Connecting Cable *2
NSH5 Removable Box
Cable
Specifications
Model
Screen transfer cable for DOS/V (CX-Designer ↔ PT)
Length: 2 m
XW2Z-S002
USB-Serial Conversion Cable
Length: 0.5 m
CS1W-CIF31
USB relay cable
Length: 1 m
NS-USBEXT-1M
RS-422A cable (loose wires + D-Sub 9-pin)
Length: 10 m
NSH5-422CW-10M
RS-232C cable (loose wires + D-Sub 9-pin)
Length: 3 m
NSH5-232CW-3M
RS-232C cable (loose wires + D-Sub 9-pin)
Length: 10 m
NSH5-232CW-10M
RS-422A cable (loose wires)
Length: 10 m
NSH5-422UL-10M
RS-232C cable (loose wires + relay cable)
Length: 3 m
NSH5-232UL-3M
RS-232C cable (loose wires + relay cable)
Length: 10 m
NSH5-232UL-10M
PT connection: 9 pins
PLC connection: 9 pins
Length: 2 m
XW2Z-200T
Length: 5 m
XW2Z-500T
PT connection: 9 pins
PLC peripheral port
Length: 2 m
XW2Z-200T-2
RS-232C Cable (connectors)
Length: 5 m
XW2Z-500T-2
Length: 3 m
NSH5-232CN-3M
Length: 10 m
NSH5-232CN-10M
NSH5 Removable Box
---
NSH5-AL001
NSH5 Wall-mounting
Bracket
---
NSH5-ATT02
NSH5 Visor
---
NSH5-ATT01
Standards
--N
---
CU
---
*1. Use a standard USB Type A male to Type B type male Cable to connect the NS series PT to a personal computer (CX-Designer).
Use a standard USB cable to connect the NS series PT to a PictBridge-compatible printer. USB cable type depends on the printer.
*2. To connect the NS series PT to NJ series Controller, using a commercially available 10/100-BASE-TX twisted-pair cable.
For detail, refer to the NS series SETUP MANUAL (Cat. No.V083).
9
NS Series
Options
Product name
Video
Input
Unit
Specifications
Model
Inputs: 4 channels
Signal type: NTSC/PAL
Standards
NS-CA001
UC1, CE
Input channels: 2 video channels and 1 RGB channel *1
Signal type: NTSC/PAL
NS-CA002
For Controller Link Communications
NS-CLK21
Transmission distance: 500 m total length
Note: Use this model when connecting PT models without a V@ suffix.
Note: PT models with the V@ suffix can also be connected.
NS-AL002
Transmission distance: 50 m total length
Note: Only PT models with a suffix of V@ are connectable.
Use the NS-AL002 to connect models without a V@ suffix.
CJ1W-CIF11
Controller Link Interface
Unit
RS-422A
Adapter
Anti-reflection Sheets
(5 surface sheets)
Sheet/Cover *2
Protective Covers (5 pack)
(anti-reflection coating)
Protective Covers
(1 cover included)
(Transparent)
Protective Covers
(5 covers included)
(Transparent)
NS15-KBA04
NS12/10
NS12-KBA04
NS8
NS7-KBA04
NS5
NT30-KBA04
NS12/10
NS12-KBA05
NS8
NS7-KBA05
NS5
NT31C-KBA05
NS15
NS15-KBA05N
NS12/10
NS12-KBA05N
NS8
NS7-KBA05N
NS5
NT31C-KBA05N
NT625C/631/631C Series to NS12/10 Series
NS12-ATT01
NT625C/631/631C Series to NS12/NS10 Series (Black)
NS12-ATT01B
NT610C Series to NS12/10 Series
NS12-ATT02
NT620S/620C/600S Series to NS8 Series
NS8-ATT01
NT600M/600G/610G/612G Series to NS8 Series
NS8-ATT02
128 MB
HMC-EF183
256 MB
HMC-EF283
512 MB
HMC-EF583
Memory Card Adapter
---
HMC-AP001
Replacement Battery
Battery life: 5 years (at 25°C)
CJ1W-BAT01
Bar Code Reader
CCD handheld bar code reader (RS-232C interface)
V520-RH21-6
Attachment
Memory
Card
*1. One screen cannot display two video inputs simultaneously.
*2. A Chemical-resistant Cover (NT30-KBA01) is available only for the NS5.
10
NS15
UC1, CE
---
UC1, N,
L, CE
---
CE
---
NS Series
General Specifications
NS5/NS8/NS10/NS12/NS15
Series
Rated power supply
voltage
NS5-V2
NS8-V2
NS10-V2
NS12-V2
NS15-V2
24 VDC
Allowable voltage range 20.4 to 27.6 VDC (24 VDC ±15%)
Power consumption
15 W max.
Ambient operating
temperature
0 to 50 °C (See note on the next page.)
Note: The ambient operating temperature is subject to the following restrictions according to
the mounting angle.
Mounting angle of 0 to 30° to the horizontal:
• When no Expansion Units are mounted, the operating temperature range is 0 to 45°C.
• When a Video Input Unit or a Controller Link Interface Unit is mounted, the ambient
operating temperature is 0 to 35°C.
Mounting angle of 30 to 90° to the horizontal: Operating temperature range of 0 to 50°C
25 W max.
45 W max.
Storage temperature
−20 to 60 °C *1
Ambient operating
humidity
35 to 85% (0 to 40 °C), 35 to 60% (40 to 50 °C) (with no condensation)
Operating environment
No corrosive gases.
Noise immunity
Conforms to IEC61000-4-4, 2 kV (power lines).
90°
5 to 8.4 Hz, 3.5 mm single
amplitude, 8.4 to 150 Hz,
9.8 m/s2 10 min times
each in X, Y, and Z
directions
10 to 57 Hz, 0.075 mm amplitude, 57 to 150 Hz, 9.8 m/s2 30 min each in X, Y, and Z directions
Shock resistance
(during operation)
147 m/s2 3 times each in direction of X, Y, and Z
Weight
1.0 kg max.
Degree of protection
Front operating panel: IP65 oil-proof type and NEMA4 UL type 4. *2
Note: May not be applicable in locations with long-term exposure to oil.
Ground
Ground to 100 Ω or less.
Battery life
5 years (at 25 °C): Replace battery within 5 days after the battery runs low (indicator lights orange).
Applicable standards
Certified for conformance to UL 508, UL 1604, EMC Directive, NK, and LR Standards.
2.3 kg max.
2.5 kg max.
*1. Operate the PT within the temperature and humidity ranges shown in the right diagram.
*2. Support for NS5, NS10, NS12 and NS15.
4.2 kg max.
Operation
Storage
50
Temperature (°C)
0
−20 0
NSH5 Hand-held PT
Series
30°
Horizontal 0°
Vibration resistance
(during operation)
2.0 kg max.
e
ac
urf
ys
pla
Dis
10
20
40
30
Humidity (%RH)
95% 80%
60
60%
40%
35%
20%
10%
10 20 30 40 50 60 70 80
Temperature (°C)
NSH5-V2
Type
5.7-inch Color TFT (Hand-held Version)
Case color
Black
Built-in Ethernet port
No
Model
NSH5-SQR10B-V2 (Emergency stop button: Red)
Rated power supply
voltage
24 VDC
NSH5-SQG10B-V2 (Stop button: Gray)
Allowable voltage range 20.4 to 27.6 VDC (24 VDC ±15%)
Power consumption
10 W max.
Ambient operating
temperature
0 to 40°C
Storage temperature
−20 to 60°C
Ambient operating
humidity
35% to 85% (0 to 40°C) with no condensation
Operating environment
No corrosive gases.
Noise immunity
Common mode: 1,000 Vp-p (between power supply terminals and panel)
Normal mode: 300 Vp-p
Pulse width: 100 ns to 1 μs, Rise time: 1-ns pulse
Vibration resistance
(during operation)
10 to 57 Hz, 0.075 mm amplitude, 57 to 150 Hz, 9.8 m/s2 30 min each in X, Y, and Z directions
Shock resistance
(during operation)
147 m/s2 3 times each in direction of X, Y, and Z
Weight
1 kg max.
Degree of protection
Equivalent to IP65.
Ground
Ground to 100 Ω or less.
Battery life
5 years (at 25°C): Replace battery within 5 days after the battery runs low (indicator lights orange).
Applicable standards
Certified for conformance to UL 508, EMC Directive, and EN 60204-1.
11
NS Series
Performance/Specifications
NS5
Series
NS5-V2
Model
NS5-SQ10-V2
NS5-SQ11-V2
NS5-SQ10B-V2
NS5-SQ11B-V2
NS5-TQ10-V2
NS5-TQ11-V2
NS5-TQ10B-V2
NS5-TQ11B-V2
Built-in Ethernet port
No
Yes
No
Yes
No
Yes
No
Yes
Case color
Ivory
Display device
TFT color LCD
Effective display area
Width 117.2 × height 88.4 mm (5.7 inches)
Display colors
256 colors
Number of dots
320 dot horizontal × 240 dot vertical
View angle
Left/right: 80°, Top: 80°, Bottom: 60° *5
Screen data capacity
60 Mbytes
Image data
(BMP or JPG images)
32,768 colors
Memory Card
Supported
Ladder Monitor function
Not supported
Video Input Unit support
Not supported
Controller Link Interface
Unit (Wired) support
Not supported
Black
Ivory
Black
Color High-luminance TFT *1
Service life * 3 75,000 hours min.
Backlight *2
Brightness
adjustment
Three-level or 32-level brightness adjustment from the touch panel screen. * 4
Backlight
error
detection *5
Error is detected automatically, and the RUN indicator flashes green as notification.
Method
Matrix resistive membrane
Number of
Touch panel switches/
(matrix
resolution
type)
Input
Display text
300 (20 horizontal × 15 vertical) 16 × 16 dots for each switch
Pressure-sensitive
Service life
1,000,000 touch operations.
Labels
Can be specified in CX-Designer. Font, style, and size can be specified.
Numerals,
alarms, and
character
strings
Scalable Gothic: Magnification: 6 to 255 points
Rough:
Magnification: 1×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8
Standard:
Magnification: 1×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8
Fine:
Magnification: 1×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8
7-segment display: Can display only numerals, dates, and times.
Scalable Gothic, rough, standard, and fine can be used for 42 languages.
Japanese, simplified Chinese, traditional Chinese, Korean, English, French, German, Italian, Portuguese, Spain, Swedish, Dutch,
Supported
Finnish, Norwegian, Basque, Catalan, Danish, Albanian, Croatian, Czech, Hungarian, Polish, Romanian, Slovak, Slovenian,
languages
(42 languages) Bulgarian, Belarusian, Russian, Serbian, Macedonian, Ukrainian, Georgian, Icelandic, Afrikaans, Faroese, Indonesian, Greek,
Turkish, Estonian, Latvian, Lithuanian, Thai (supported only with scalable Gothic font)
Text
attributes
Flicker
Color
256 colors
Font style
(only when
vector font is
specified)
Bold or italic
Vertical
alignment
Top, center, or bottom
Horizontal
alignment
Left-justified, centered, or right-justified
Objects
supporting
flicker
Functional objects: Select from up to 10 types of registered flicker settings. The flicker speed and flicker range can be set.
Fixed objects:
Select from three flicker types.
Numeral units and scale
settings
1.000 max.
Alarm/event settings
5,000 max.
Expansion interface
For Expansion Interface Units
*1. NS5-TQ series (high luminance TFT) luminance is better than that of NS5-SQ series by about 110 cd/m2.
*2. Contact your nearest OMRON representative to replace the backlight.
*3. This is the estimated time before brightness is reduced by half at room temperature and humidity. It is not a guaranteed value.
The service life will be dramatically shortened if PT is used at low temperatures. For example, using the PT at temperatures of 0°C will reduce
the service life to approximately 10,000 hours (reference value).
*4. Lot No. 15Z0 or later of NS5 models.
*5. This function does not indicate that the service life has been reached. It detects when the backlight is not lit due to a disconnection or other
errors.
Backlight error detection indicates that all backlights (2) are OFF.
12
NS Series
NS8/NS10/NS12/NS15
Series
NS8-V2
NS8NS8TV01- TV00B
V2
-V2
Yes
No
Black
Display device
High-definition TFT color LCD
High-definition TFT color LCD
High-definition TFT color LCD
Effective display area
Width 170.9 × height 128.2 mm
(8.4 inches)
Width 215.2 × height 162.4 mm
(10.4 inches)
Width 246.0 × height 184.5 mm
(12.1 inches)
Display colors
256 colors
Number of dots
640 dot horizontal × 480 dot vertical
Left/right: 70°, Top: 65°,
Bottom: 65° *3
800 dot horizontal × 600 dot
vertical
Left/right: 80°, Top: 80°,
Bottom: 80° *3
View angle
Screen data capacity
Image data
(BMP or JPG images)
Memory Card
Ladder Monitor function
Left/right: 80°, Top: 80°,
Bottom: 60° *3
60 Mbytes
NS10TV00V2
No
Ivory
NS12TS01B
-V2
Yes
NS15-V2
NS15NS15TX01STX01BV2
V2
Yes
Yes
Silver
Black
High-definition TFT
color LCD
Width 304.1 × height
228.1 mm
(15 inches)
1,024 dot horizontal
× 768 dot vertical
Left/right: 80°, Top:
70°, Bottom: 60°
Supported
Supported
Supported (Image displayed via video input is 260,000 colors)
Controller Link Interface
Unit (Wired) support
Service life * 2
Brightness
adjustment
Backlight *1
Backlight
error
detection *4
Not supported
Number of
Touch panel switches/
(matrix type) resolution
Input
Service life
Labels
NS12TS00V2
No
Ivory
32,768 colors
Video Input Unit support
Method
NS10TV01B
-V2
Yes
NS12-V2
NS12- NS12TS01- TS00B
V2
-V2
Yes
No
Black
Built-in Ethernet port
Case color
Model
NS8TV01B
-V2
Yes
NS10-V2
NS10- NS10TV01- TV00B
V2
-V2
Yes
No
Black
NS8TV00V2
No
Ivory
(Only RGB input is
enabled.)
Supported
50,000 hours min.
Three-level or 32-level brightness adjustment from the touch panel screen. * 3
Error is detected automatically, and the RUN indicator flashes green as notification.
Matrix resistive membrane
768 (32 horizontal × 24 vertical)
20 × 20 dots for each switch
1,200 (40 horizontal × 30 vertical)
16 × 16 dots for each switch
1,900 (50 horizontal × 38 vertical)
16 × 16 dots for each switch
Analog resistive
membrane *5
Resolution: 1,024
(horizontal) × 1,024
(vertical)
Pressure-sensitive
1,000,000 touch operations.
Can be specified in CX-Designer. Font, style, and size can be specified.
Scalable Gothic:
Magnification: 6 to 255 points
Numerals,
Rough: Magnification: 1×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8
alarms, and
Standard: Magnification: 1×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8
character
Fine: Magnification:
1×1, 1×2, 2×1, 2×2, 3×3, 4×4, 8×8
strings
Display text
7-segment display:
Can display only numerals, dates, and times.
Scalable Gothic, rough, standard, and fine can be used for 42 languages.
Supported
Japanese, simplified Chinese, traditional Chinese, Korean, English, French, German, Italian, Portuguese, Spain, Swedish, Dutch,
languages
Finnish, Norwegian, Basque, Catalan, Danish, Albanian, Croatian, Czech, Hungarian, Polish, Romanian, Slovak, Slovenian,
(42 languages) Bulgarian, Belarusian, Russian, Serbian, Macedonian, Ukrainian, Georgian, Icelandic, Afrikaans, Faroese, Indonesian, Greek,
Turkish, Estonian, Latvian, Lithuanian, Thai (supported only with scalable Gothic font)
Color
256 colors
Font style
(only when
Bold or italic
vector font is
Text
specified)
attributes
Vertical
Top, center, or bottom
alignment
Horizontal
Left-justified, centered, or right-justified
alignment
Objects
Functional objects: Select from up to 10 types of registered flicker settings. The flicker speed and flicker range can be set.
supporting
Flicker
Fixed objects:
Select from three flicker types.
flicker
Numeral units and scale
1.000 max.
settings
Alarm/event settings
5,000 max.
Expansion interface
For Expansion Interface Units
*1. Contact your nearest OMRON representative to replace the backlight.
*2. This is the estimated time before brightness is reduced by half at room temperature and humidity. It is not a guaranteed value.
The service life will be dramatically shortened if PT is used at low temperatures. For example, using the PT at temperatures of 0 °C will reduce
the service life to approximately 10,000 hours (reference value).
*3. Lot No. 28X1 or later of NS8 models, Lot No. 11Y1 or later of NS10 models, Lot No. 14Z1 or later of NS12 models, Lot No. 31114K or later of
NS15 models.
*4. This function does not indicate that the service life has been reached. It detects when the backlight is not lit due to a disconnection or other errors.
Backlight error detection indicates that all backlights (2) are OFF.
*5. An analog touch panel is used with the NS15. Do not press the touch panel in two or more places simultaneously.
If the touch panel is pressed in two or more places simultaneously, it may activate a switch between the points that are pressed.
13
NS Series
Communications
NS5/NS8/NS10/NS12/NS15
Memory Card
Interface
One ATA-Compact Flash interface slot
Functions
Used to transfer and store screen data, store logging data, and store history data. (Alarm/Event History, Operation
Log, and Error Log generated during Macro execution).
Connector
Conforms to EIA RS-232C. D-Sub female 9-pin connector 5-V output (250 mA max.) through pin 6.
The 5-V outputs of serial ports A and B cannot be used at the same time.
Functions
Host (PLC) access: 1:N NT Links (connections with CS/CJ/CP-series PLCs and C200HX/HG/HE(-Z) PLCs),
1:1 NT Links, or Host Link (connections with C Series or CVM1/CV-series PLCs)
Direct access to Temperature Controllers using Smart Active Parts:
CompoWay / F and bar code reader connections (Read directly from display.)
Connector
Conforms to EIA RS-232C. D-Sub female 9-pin connector. 5-V output (250 mA max.) through pin 6.
The 5-V outputs of serial ports A and B cannot be used at the same time.
Functions
Host (PLC) access: 1:N NT Links (connections with CS/CJ/CP-series PLCs and C200HX/HG/HE(-Z) PLCs) or
1:1 NT Links (connections with C Series or CVM1/CV-series PLCs)
Direct access to Temperature Controllers using Smart Active Parts:
CompoWay / F and bar code reader connections (Read directly from display.)
USB rating
USB1.1
Connector
TYPE-B (Slave)
Functions
Connection with the CX-Designer (for screen data transfers) Connecting to a PictBridge-compatible Printer
Recommended printers: EPSON: PM-G4500, PX-G5300, PX-5600, EP-901F
Canon: PIXUS MX7600, PIXUS iP100, PIXUS iX5000
USB rating
USB1.1
Connector
TYPE-A (Host)
Functions
Connection with a printer (for hard copies)
Recommended printers: EPSON: PX-G930
Conformance
standards
Conforms to IEEE 802.3/Ethernet (10 Base-T/100 Base-TX).
Functions
Host (PLC) access and connection with the CX-Designer (for screen data transfers)
Baud rate
2 M/1 M/500 K bps
Transmission
path
Shielded twisted-pair cable (special cable)
Functions
Host (PLC) access and data links
Resolution
NS-CA001: 320×240, 640×480, 800×600 dots
NS-CA002: User-defined size
Input signal
NS-CA001: NTSC composite video or PAL
NS-CA002: NTSC composite video or PAL
Number of
video inputs
NS-CA001: Number of cameras: 4 max.
NS-CA002: 2 cameras + RGB
Port A
Serial
Communications
Port B
USB
SLAVE
Specifications
USB HOST
Specifications *1
Built-in Ethernet
Specifications *2
Controller Link (Wiredtype)
Specifications *3
Video Input Specifications
*4
*1. Except NS5.
*2. NS@-@@@1-V2 only.
*3. Except NS5 and NS8.
*4. Except NS5 and NS15. NS15 provides RGB input. (NS-CA002)
14
NS Series
Connectable Devices
Supported OMRON PLCs
PLC series
C Series
CVM1/CV
Series
CS Series
CJ Series
CP Series
PLC model name
RS-232C *1
1:1 NT Link
Ethernet
1:N NT Link
Host Link
FINS *2
EtherNet/IP *3
Controller Link *4
CQM1
Yes
No
Yes
No
No
No
CQM1H
Yes
Yes
Yes
No
No
Yes
CPM1
Yes
No
Yes
No
No
No
CPM1A
Yes
No
No
No
No
No
CPM2A
Yes
No
Yes
No
No
No
CPM2C
Yes
No
Yes
No
No
No
C200HS
Yes
No
Yes
No
No
No
C200HE (-Z)
Yes
Yes
Yes
No
No
Yes
C200HG (Z)
Yes
Yes
Yes
No
No
Yes
C200HX (-Z)
Yes
Yes
Yes
No
No
Yes
CV500/1000/2000
Yes
No
Yes
Yes
No
Yes
CVM1
Yes
No
Yes
Yes
No
Yes
CS1H
No
Yes
Yes
Yes
Yes
Yes
CS1G
No
Yes
Yes
Yes
Yes
Yes
CS1D
No
Yes
Yes
Yes
Yes
Yes
CJ1H
No
Yes
Yes
Yes
Yes
Yes
CJ1G
No
Yes
Yes
Yes
Yes
Yes
CJ1M
No
Yes
Yes
Yes
Yes
Yes
CJ2H
No
Yes
Yes
Yes
Yes
Yes
CJ2M
No
Yes
Yes
Yes
Yes
Yes
CP1H
No
Yes
Yes
Yes
Yes
No
CP1L
No
Yes
Yes
Yes
No
No
CP1E
No
Yes
Yes
No
No
No
Yes *5
Yes *5
Yes *5
No
Yes *6
No
No
No
No
No
Yes
No
NJ Series
NJ5/NJ3/NJ1
NX Series
NX7
Note: Including models whose production were discontinued.
*1. To connect a NS with a PLC via a RS-422A connection, OMRON's NS-AL002, or CJ1W-CIF11 RS-232C/RS-422A Converter can be used to
convert the RS-232C port on the NS to RS-422A.
*2. A NS with Ethernet port is necessary.
When connecting a PLC with the NS, an Ethernet port is necessary on the PLC, too. Use a PLC CPU Unit with a built-in Ethernet port, or add
an Ethernet Unit.
*3. A NS with Ethernet port is necessary.
When connecting a PLC with the NS, an EtherNet/IP port is necessary on the PLC, too. Use a PLC CPU Unit with a built-in EtherNet/IP port,
or add an EtherNet/IP Unit.
*4. Install a Controller Link Interface Unit on the NS. A Controller Link Unit is necessary for the PLC.
*5. Mount a Serial Communications Unit on the NJ-series Controller. A NS can access only to the Controller's memory used for CJ-series unit.
*6. When using a EtherNet/IP Unit to connect the NJ-series Controller, NJ Troubleshooter is not supported.
15
NS Series
Function Comparison
PLC series
C series
CVM1/CV
series
PLC model name
Ladder
Monitor
Device Monitor/
Switch Box
PLC Data
Trace
SPMA
SAP
NJ
EtherNet/IP
Troubleshooter/
Tag access
PLC
Integrated
(Network
Troubleshooter
NS-series PT
symbols)
simulation *4
CQM1
No
No
No
No
No
No
No
CQM1H
No
No
No
No
No
No
No
No
CPM1
No
No
No
No
No
No
No
No
CPM1A
No
No
No
No
No
No
No
No
CPM2A
No
No
No
No
No
No
No
No
CPM2C
No
No
No
No
No
No
No
No
C200HS
No
No
No
No
No
No
No
No
C200HE (-Z)
No
No
No
No
No
No
No
No
C200HG (-Z)
No
No
No
No
No
No
No
No
C200HX (-Z)
No
No
No
No
No
No
No
No
CV500/1000/2000
No
No
No
No
No
No
No
No
CVM1
No
No
No
No
No
No
No
No
CS1H
Yes
Yes
Yes
Yes
Yes
No
Yes
No
CS1G
Yes
Yes
Yes
Yes
Yes
No
Yes
No
CS1D
Yes
Yes
Yes
Yes
Yes
No
Yes
No
CJ1H
Yes
Yes
Yes
Yes
Yes
No
Yes
No
CJ1G
Yes
Yes
Yes
Yes
Yes
No
Yes
No
CJ1M
Yes
Yes
Yes
Yes
Yes
No
Yes
No
CJ2H
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
CJ2M
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
CP1H
Yes
Yes
Yes
Yes *1
Yes
No
No
No
CP series
CP1L
Yes
Yes
Yes
Yes *1
Yes
No
No
No
CP1E
No
No
No
Yes *1
Yes
No
No
No
NJ series
NJ5/NJ3/NJ1
No
Yes *2
No
No
Yes *3
Yes
No
Yes
NX Series
NX7
No
No
No
No
No
Yes
No
Yes
CS series
CJ series
Note: Including models whose production were discontinued.
*1. The SPMA relaying a PLC is not supported.
*2. Only Device Monitor function is supported. Monitoring function that uses tags (variables) is not supported.
*3. The SAP for CJ-series Special I/O Units and CPU Bus Units that can be used with NJ-series Controller is supported.
*4. Sysmac Studio version 1.02 or higher (CX-Designer version 3.41 or higher) is required.
16
No
NS Series
Connectable Inverters
Series
3G3MX2-V1
Communication Unit
Connection
(Use the RS-485 terminal on the Inverter)
3G3JX
(Use the RS-485 connector on the Inverter)
3G3RX-V1
(Use the RS-485 terminal on the Inverter)
RS-485 (2-wire)
1:N
Connectable Temperature Controllers
The following Temperature Controllers can be connected directly to an NS-series PT*.
Unit name
Series
Model
Modular Temperature Controller
EJ1
EJ1-EDU End Unit
Modular Temperature Controller
E5ZN
E5ZN-SCT24S Terminal Unit
E5AR
E5AR-@@@@@@@@@-FLK
E5ER
E5ER-@@@@@@@@@-FLK
Digital Controller
Remarks
E5CN-@@@@@T-FLK Multi-input
(Thermocouple/Resistance Thermometer) Type
E5CN-@@@@@L-FLK Analog Input Type
E5AN/E5EN/E5CN
(Basic Model)
E5EN-@@@@@T-FLK Multi-input
(Thermocouple/Resistance Thermometer) Type
E5EN-@@@@@L-FLK Analog Input Type
SAP screens are
available.
E5AN-@@@@@T-FLK Multi-input
(Thermocouple/Resistance Thermometer) Type
Temperature Controller
(Digital Controller)
E5AN-@@@@@L-FLK Analog Input Type
E5AN-H/E5EN-H/
E5CN-H
(Advanced Model)
E5GN
E5CN-H@@@@@@@-FLK Universal-input Model
E5EN-H@@@@@@@@-FLK Universal-input Model
E5AN-H@@@@@@@@-FLK Universal-input Model
E5GN-@@@TC-FLK Thermocouple Input Type
E5GN-@@@P-FLK Resistance Thermometer Input Type
Note: Including models whose production were discontinued.
* The NS-Runtime cannot be connected directly to a Temperature Controller.
17
NS Series
Connecting to Another Company’s PLC
Manufacturer
Series
A Series
FX Series
Mitsubishi Electric
Q/QnA Series
CPU
Computer Link Unit
A1SJ71UC24-R@
A1SJ71UC24-PRF
A2ACPU
Computer Link Unit
AJ71UC24
FX0N
FX1S
FX1N
FX1NC
FX2N
FX3UC
FX3G
Communication special adapter
FX3U-232-ADP
FX2NC-232ADP
FX0N-232-ADP
Connection diagram
RS-232C,
RS422A/485 *1
1:1
RS-232C,
RS422A/485 *1
1:1
RS-232C
1:1
RS-232C,
RS-485 (4-wire) *2
1:N
Communication expansion board
FX@@-232-BD
Q00CPU
Q01CPU
RS-232C port on the CPU Module
Q00CPU
Q01CPU
Q00JCPU
Q02CPU
Q02HCPU
Q06HCPU
Q12HCPU
Q25HCPU
Q03UDCPU
Q06UDHCPU
Q13UDHCPU
Serial Communications Module
QJ71C24N-R2
QJ71C24N-R4
QJ71C24N
Q2ASCPU
Q2ASCPU-S1
Q2ASHCPU
Q2ASHCPU-S1
Serial Communications Module
A1SJ71QC24N
CPU built-in RS-232C port
RS-232C
Personal Computer Link Module
F3LC11-1F
F3LC12-1F
F3LC11-2F
RS-232C, RS-422A/485 *1
CPU313
CPU315-2DP
CPU317-2PN/DP
SIMATIC S7 HMI Adapter
6ES7 972-0CA1@-0XA0
RS-232C
1:1
SLC5/03
SLC5/04
SLC5/05
RS-232C port on the CPU Module
RS-232C
1:1
1:1
Yokogawa
Electric
FA-M3(R) Series
F3SC23-1F
F3SP21-0N
F3SP28-3S
F3SP58-6S
F3SP67-6S
Siemens
S7-300 Series
SLC500
Rockwell
(Allen-Bradley)
Communication Unit/Adapter/Board
A1SHCPU
A2USCPU
A2USHCPU-S1
MicroLogix
MicroLogix 1500
RS-232C port on the CPU Module
RS-232C
ControlLogix
Logix5555
RS-232C port on the CPU Module
RS-232C
1:1
CompactLogix
1769-L31
RS-232C port on the CPU Module
RS-232C
1:1
PLC-5
PLC-5/20
RS-232C port or RS-485 port on the
CPU Module
RS-232C/RS-485 (4-wire)
1:N
*1. To connect using RS-422A/485, an RS-232C/422A converter (e.g. NS-AL002, CJ1W-CIF11) is required.
*2. To connect using RS-485, an RS-232C/422A converter (e.g. NS-AL002, CJ1W-CIF11) is required.
Up to 32 sequencers can be connected when using RS-485.
18
1:1
NS Series
Component Names and Options
NS15
RS-422A/485 Serial Interface
Memory Card interface
Memory Card
Note:
Colors shown
in photographs and
product names may
differ from actual
colors and names.
Expansion interface
Battery
Analog RGB Output
RS-232C serial port A
RS-232C serial port B
A bar code reader can be connected to the serial port.
Recommended bar code reader: V520-RH21-6
Connector for
Brightness Adjustment
Ethernet (10 Base-T or 100 Base-TX)
Power Supply (24 VDC)
USB SLAVE (For transferring screens and connecting a PictBridge-compatible printer)
USB HOST (for printer)
NS12/10
Memory Card interface
Memory Card
Note:
Colors shown
in photographs and
product names may
differ from actual
colors and names.
Expansion interface
Battery
RS-232C serial port A
RS-232C serial port B
Power Supply (24 VDC)
A bar code reader can be connected to the serial port.
Recommended bar code reader: V520-RH21-6
Ethernet (10 Base-T or 100 Base-TX)
USB SLAVE (For transferring screens and connecting a PictBridge-compatible printer)
USB HOST (for printer)
NS8
Memory Card interface
Expansion interface
Memory Card
Battery
RS-232C serial port A
RS-232C serial port B
Power Supply
(24 VDC)
Note:
Colors shown in photographs
and product names may
differ from actual colors and
names.
A bar code reader can be connected to the serial port.
Recommended bar code reader: V520-RH21-6
Ethernet (10 Base-T or 100 Base-TX)
USB SLAVE (For transferring screens and connecting a PictBridge-compatible printer)
USB HOST (for printer)
19
NS Series
NS5
Memory Card interface
Memory Card
Note:
Colors shown
in photographs and
product names may
differ from actual
colors and names.
Expansion interface
Ethernet (10 Base-T or 100 Base-TX)
USB SLAVE (For transferring screens and
connecting a PictBridge-compatible printer)
Battery
Power Supply (24 VDC)
RS-232C serial port A
RS-232C serial port B
A bar code reader can be connected to the serial port.
Recommended bar code reader: V520-RH21-6
NSH5
USB Port
Enable Switch
Memory Card interface
LED
Emergency Stop Switch
Function Switches
Hand Strap
Cable
Optional Products
Video Input Unit
NS-CA001 (with Cover)
RGB/Video Input Unit
NS-CA002 (with Cover)
Controller Link Interface Unit RS-422A Adapter
NS-CLK21 (with Cover)
CJ1W-CIF11
Communications Cable
XW2Z-S002
Protective Cover/Anti-reflection
Sheet for NS-series PT
NS-KBA0 (N)
NT30/NT31C-KBA05 (N)
USB Serial Conversion Cable USB relay cable
CS1W-CIF31
(IP65 oil-proof type)
NS-USBEXT-1M
20
RS-232C/RS-422A
Conversion Unit
NS-AL002
NS Series
Dimensions
(Units: mm)
NS15
170
Mounting Panel
Mounting Bracket
79.54
13.95
94.8
RUN
RDA
RDB
SDA
46
SDB
27.4
282
304.5
304
71.8
RSA
RSB
57.31
3.8
86.83
85.6
8
405
37.9 (min.)
41.1 (max.)
39.4
84.1
70
75.8
Recommended Panel Cutout Dimensions
15.5
340
383
405.5
+1
282.5 −0
383.5 +1
−0
NS12/10
Recommended Panel Cutout
Dimensions
140 241
228 +1
−0
SW
227 249
RESET
121
24V
DC
PORT B
HOST
134
PORT A
SLAVE
ETHERNET
15.5
264
315
323
7.5
39 (min.)
48.5 42 (max.)
3.8
49
302 +1
−0
13.7
49.9
23
90.4
301
NS8
NS5
39.83
165 188
177
27.3
15.5
5
48.5
153.3
130.5
RUN
142
44.55
180
232
195
39 (min.)
42 (max.)
15.5
5
145
90
49
53.8
206.3
220
34 (min.)
38 (max.)
54.8
183.5
Recommended Panel
Cutout Dimensions
Recommended Panel
Cutout Dimensions
SW
131 +0.5
−0
RESET
24V
DC
120.5
PORT B
PORT A
68.48
165.5 +0.5
−0
107.6
ETHERNET
HOST
ETHERNET
21
51.7
19.1
220.5 +0.5
−0
26.6
9.6
19.5
184 +0.5
−0
77
44.1 50.1
63.4
21
NS Series
Hand-held NS5
16.5
223
70.5
75
50
176
75
81.3
9.6
164
(169)
9.6
164
(169)
(1.9)
127.3
50.3
68.3
86.3
104.3
9.7
20.4
11
(102.7)
151.5
(183)
21.4
5
(22.3)
10.6
81.3
(102.7)
21.4
(1.9)
NS-CLK21
Controller Link Interface Unit
NS-CA002
Video Input Unit
NS-CA001
Video Input Unit
31.5
9.7
(22.3)
11.1
5
5
164
20.4
11
(1.9)
39.3
57.3
82.8
118.3
(169)
10.8
(33.9)
32
11
95.6
Related Manuals
Cat. No.
V083
22
Model
Manual
NS15/NS12/NS10/NS8/NS5
NS-Series Programmable Terminals SETUP MANUAL
NS-Series Programmable Terminals PROGRAMMING MANUAL
V073
NS15/NS12/NS10/NS8/NS5
V099
NS-CXDC1-V3
CX-Designer Ver.3.@ USER'S MANUAL
V082
NS
NS-Series Ladder Monitor OPERATION MANUAL (Ladder Monitor I/O Comment Extracting Tool)
V086
NS-CA002
NS-Series RGB and Video Input Unit OPERATION MANUAL
V090
NSH5
NSH5-Series Hand-held Programmable Terminal OPERATION MANUAL
NS-Series Programmable Terminals HOST CONNECTION MANUAL (Host Link) OPERATION MANUAL
V098
NS15/NS12/NS10/NS8/NS5
V085
NS15/NS12/NS10/NS8/NS5
NS-Series Programmable Terminals HOST CONNECTION MANUAL
V092
NS15/NS12/NS10/NS8/NS5
NS-Series Programmable Terminals HOST CONNECTION MANUAL Multivendor Connection
V075
NS15/NS12/NS10/NS8/NS5
NS-Series Programmable Terminals Macro Reference
V093
NS-NSRCL@@
NS-NSRCL@@ NS-Runtime Software USERS MANUAL
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions
or comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT
THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the
customer's application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to
the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end
product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all
possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines,vehicles,
safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY
RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may
represent the result of OMRONÅfs test conditions, and the users must correlate it to actual application requirements. Actual performance is subject
to the OMRON Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Industrial Automation Company
Authorized Distributor:
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
© OMRON Corporation 2011 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
CSM_11_5_0516
Cat. No. V405-E1-14
0712 (1206)