UL Report for MSP_Contactor Combinations_3RA.pdf

File E156943
Project 00ME17885
December 18, 2000
REPORT
on
COMBINATION CONTROLLERS
Siemens AG
Amberg, Germany
Copyright © 2000 Underwriters Laboratories Inc.
Underwriters Laboratories Inc. authorizes the above-named company to reproduce
this Report provided it is reproduced in its entirety.
File E156943
Vol. 1
Sec. 14
and Report
Page 1
Issued:
Revised:
2000-12-18
2005-07-03
DESCRIPTION
PRODUCT COVERED:
USL, CNL - Combination motor controllers, Type No. 3RA followed by 11 or 12,
followed by 2, 3 or 4, followed by 0, 1, 2, 3, 4, 5, or 9 followed by a *number
and a letter, followed by A or B, followed by 23, 24, 25, 26, 34, 35, 36, 44, 45
or 46, followed by a combination of four letters and numbers.
USL, CNL - Combination motor controllers with fastbus backplate, Type No.
3RA followed by 11 or 12, followed by 1 or 2, followed by 0, 1, 2, 3, 4, 5, or 9
followed by a number and a letter, followed by C or D, followed by 15, 16, 17, 23,
24, 25 or 26, followed by a combination of four letters and numbers.
*
Link modules, Type Nos. 3RA1921-1A, 3RA1921-1B, 3RA1921-1D, 3RA1931-1A,
3RA1931-1B, 3RA1941-1A or 3RA1941-1B, may be followed by A00.
Mounting Adapter, Type Nos. 3RA1922-1A, 3RA1932-1A, 3RA1942-1A or 3RA19021B.
Line Terminal Adapter, Type Nos. 3RV1928-1H, 3RV1925-5EB or 3RT1946-4GA07
Assembly Sets, Type Nos. 3RA19, followed by 13, 23, 33 or 43, followed by –
1B, -1C or –1C.
GENERAL:
These devices are open type 3-pole combination motor controllers Type F,
reversing and non-reversing, for use in industrial applications. They consist of
Listed Self-Protected manual Combination Controllers connected to Listed magnetic
motor controllers (contactors.)
Combination
adapters cat. No.
Combination motor
adapters cat. No.
motor controllers, Type 3RA1.2 must be used with line terminal
3RV1928-1H or 3RV1925-5EB except 3RA1.2 with fastbus backplate.
controllers, Type 3RA1.4 must be used with line terminal
3RT1946-4GA07. The adapters may be factory or field-installed.
ENGINEERING CONSIDERATIONS (NOT FOR UL REPRESENTATIVE USE):
USL – Indicates investigation according to UL 508, 17th edition.
CNL - Indicates investigated to Canadian National Standards C22.2 No. 14M95.
Note - CNL - Canadian National Standards - Listed.
USL - United States Standards - Listed.
*
File E156943
Vol. 1
Sec. 14
and Report
Page 2
Issued:
Revised:
2000-12-18
2005-07-03
RATINGS:
The horsepower ratings for the combination motor controllers 3RA1 are the same as
for the contactors 3RT10. For details refer to File E31519 Vol.8, Sec. 1 and 2;
Vol. 11 Sec. 1 and 2.
Short-circuit ratings: These devices have the following short-circuit ratings
(RMS symmetrical amperes):
*
Controller
3RA111
3RA121
3RA112
3RA122
3RA113
3RA123
3RA114
3RA124
Size
Voltage [V]
/
S00
/
S0
/
S2
/
S3
480
600
480
600
480
600
480
600
Short Circuit
Current rms
[kA]
65
10
65
25
65
30
65
30
File E156943
Vol. 1
Sec. 14
and Report
Page 4A
Issued:
New:
2000-12-18
2005-07-03
NOMENCLATURE BREAKDOWN:
3RA
I
11
II
1
III
0
IV
0A
V
A
VI
I.
Basic Type 3RA - Basic Device
II.
Type of controller
15
VII
1AB0
VIII
11 - contactor
12 - reversing contactor
III.
Size, and self-protected combination motor controller (3RV10)
size provided.
1
2
3
4
–
–
Size
Size
Size
Size
S00, with 3RV1011
S0, with 3RV1021
S2, with 3RV1031
S3, with 3RV1041
IV.
Auxiliary contact arrangement
0 - None provided
1 – 1 normally open and 1 normally closed, side mounted
2 – 2 normally open, side mounted
3 – 2 normally closed, side mounted
4 – 1 changeover contact
5 - 1 provided on 3RV10 device
9 – Custome’s determination
V.
Current setting range of 3RV10
Indicates current setting range of 3RV10
VI.
Type of Backplate and terminals
A - No Backplate, Screw Terminals
B - Din Rail Backplate, Screw Terminals
C – Fastbus Backplated 40mm system, screw terminals
D - Fastbus Backplate 60mm system, screw terminals
VII.
Catalog number of controller provided
15 - 3RT1015 contactor or 3RA1315 reverser
16 - 3RT1016 contactor or 3RA1316 reverser
23 - 3RT1023 contactor or 3RA1323 reverser
24 - 3RT1024 contactor or 3RA1324 reverser
25 - 3RT1025 contactor or 3RA1325 reverser
26 - 3RT1026 contactor or 3RA1326 reverser
*
34 - 3RT1034 contactor or 3RA1334 reverser
35 - 3RT1035 contactor or 3RA1335 reverser
36 - 3RT1036 contactor or 3RA1336 reverser
44 - 3RT1044 contactor or 3RA1344 reverser
45 - 3RT1045 contactor or 3RA1345 reverser
46 - 3RT1046 contactor or 3RA1346 reverser
*VIII.
Indicates coil voltages
File E156943
Vol. 1
Sec. 14
and Report
Page 4B
Issued:
New:
2000-12-18
2005-07-03
3RA1921-1A, 3RA1921-1B, 3RA1921-1D, 3RA1931-1A, 3RA1931-1B, 3RA1941-1A, 3RA1941-1B:
Link modules to connect 3RV10 to 3RT contactors.
3RA1922-1A, 3RA1932-1A, 3RA1942-1A:
3RA19 13
I
II
Adapters for standard din rail mounting.
-1C
III
I.
Basic Type 3RA19 – Assembly Sets for reversing starters consists of mounting
adapter or fastbus backplate and wiring connectors for reversing starters.
II.
Size
13
23
33
43
III.
–
–
–
–
For
For
For
For
3RA
3RA
3RA
3RA
with
with
with
with
contactors
contactors
contactors
contactors
3RT1.1
3RT1.2
3RT1.3
3RT1.4
Type of backplate
-1B – Din Rail backplate
-1C - Fastbus backplate 40mm system
-1D - Fastbus backplate 60mm system
File E156943
Vol. 1
Sec. 14
and Report
Page 5A
Issued:
2000-12-18
New: 2005-07-03
MARKINGS:
Paper adhesive label on the device including the manufacturer’s name, type
and electrical ratings.
For Link modules only: Paper adhesive label on the package including the
manufacturer’s name and type.
The markings for the electrical ratings are identical to those of the basic
contactors and self-protected combination motor controllers.
The terminal tightening torque must be marked on the device.
do not pertain to control circuits.
These markings
For Combination motor controllers with fastbus backplate, Type No. 3RA, the
following statement is also marked on the device:
“Combination motor controllers with fastbus backplate, Type No. 3RA…C or 3RA…D may
be used as a combination motor controller only if in the end use spacings on the
line side between bare live parts of opposite polarity and between bare live parts
and grounded metal parts are not less than 1 in (25.4 mm) measured through air or
2 in (50.4 mm) measured over the surface of insulating material.”
File E156943
Vol. 1
TYPE 3RA1120/3RA1220
(REPRESENTS ALL MODELS)
Sec. 14
and Report
Page 6
Issued:
Revised:
2000-12-18
2005-07-03
FIG. 1 (M0017282.P00)
FIG. 2 (M0017284.P00)
General - These devices consist of a Listed self-protected combination
controller, a Listed contactor or reversing contactor, a connecting element, and a
mounting adapter (as indicated in the Nomenclature item VII.