Download

Digital Controllers
E5AR
CSM_E5AR_DS_E_3_3
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5digit, 3-row LCD display for high visual
clarity.
• A short sampling period of 50 ms enables use in applications requiring high-speed response.
• PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
• Multiloop control, cascade control, and proportional control are
possible with a single Controller.
• When using models with CompoWay/F communications, initial
settings can be downloaded and settings can be masked using
Support Software (CX-Thermo version 4.0 or higher).
• Equipped with calculation functions as a standard (e.g., square
root calculation and broken-line approximation).
• DeviceNet Communications
Data setting and monitoring can be performed without special
programming.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Refer to Safety Precautions for All E5@R
Models.
Refer to E5AR/E5ER Operation for operating
procedures.
Model Number Structure
■ Model Number Legend
E5AR-@@@@@@@@@-@@@
1 2 3 4 5 6 7 8 9
10
1. Constant Values/Program
None: Constant value
2. Control Method
Blank:Standard or heating/cooling control
P:
Position proportional control
3. Output 1
R:
DPST-NO relay outputs
Q:
Pulse voltage and pulse voltage/current outputs
C:
Current and current outputs
4. Output 2
Blank:None
R:
Relay outputs
Q:
Pulse voltage and pulse voltage/current outputs
C:
Current and current outputs
Note: When your order, specify the power supply voltage.
5. Auxiliary Outputs
Blank:None
4:
4PST-NO relay outputs
T:
2 transistor outputs
6. Optional Function 1
Blank:None
3:
RS-485 communications
7. Optional Function 2
Blank:None
D:
4 event inputs
8. Input 1
B:
Universal-input and 2 event inputs
F:
Universal-input and FB
W:
Universal-input and universal-input
9. Input 2
Blank:None
W:
Universal-input and universal-input
10.Communications Method
Blank:None
FLK: CompoWay/F
DRT: DeviceNet
Note: The above model number legend is intended as a functional description of models. Not all possible combinations of functions are available.
Confirm model availability in Ordering Information when ordering.
The CX-Thermo Support Software (version 4.0 or higher) can be used to easily set parameters in conversational form.
Note: Be sure to read the precautions for correct use and other precautions in the following user's manual before using the Digital
Controller.
E5AR/E5ER Digital Controller User’s Manual (Cat. No. Z182)
E5AR/E5ER Digital Controller DeviceNet Communication User’s Manual (Cat. No. H124)
1
E5AR
Ordering Information
■ Digital Controllers
When your order, specify the power supply voltage.
Standard Controllers (100 to 240 VAC)
Size
Control type
Control mode
Outputs
(control/transfer)
96 × 96 Basic control Single-loop standard control
2 points: Pulse voltmm
(1 loop)
Single-loop heating and cooling control age and Pulse voltage/current
Optional functions
Auxiliary
outputs
(SUB)
4
Event
inputs
2
No
2 points: Current and
Current
RS-485
2 points: Current and
Current
4-loop control 4-loop standard control
2-loop heating and cooling control
6
E5AR-Q43DB-FLK
2 points: Current and
Current
E5AR-C43DB-FLK
4 points: Pulse voltage and Pulse voltage/current and
Current (2 points)
E5AR-QC43DB-FLK
2 points: Pulse voltage and Pulse voltage/current
4
4
RS-485
E5AR-Q43DW-FLK
2 points: Current and
Current
E5AR-C43DW-FLK
4 points: Pulse voltage (2 points) and
Pulse voltage/current
(2 points)
E5AR-QQ43DW-FLK
4 points: Current out- 4
put (4 points)
4
RS-485
4 points: Pulse voltage (2 points) and
Pulse voltage/current
(2 points)
Position-pro- Single-loop position-proportional control
portional con- (See note.)
trol
(1 loop)
E5AR-Q43B-FLK
E5AR-C43B-FLK
2 points: Pulse voltage and Pulse voltage/current
2-loop standard control
2-loop heating and cooling control
Single-loop cascade control
Single-loop control with remote SP
Single-loop proportional control
E5AR-Q4B
E5AR-C4B
2 points: Pulse voltage and Pulse voltage/current
2-loop control 2-loop standard control
Single-loop heating and cooling control
Single-loop cascade control
Single-loop control with remote SP
Single-loop proportional control
Model
Serial
communications
Relay output
(1 open, 1 close)
Relay output
(1 open, 1 close) and
1 current (transfer)
output
E5AR-CC43DWWFLK
E5AR-QQ43DWWFLK
4
4
No
E5AR-PR4DF
RS-485
E5AR-PRQ43DF-FLK
Note: Can be switched between close control and floating control.
2
E5AR
Standard Controllers (24 VAC/DC)
Size
Control type
Control mode
Outputs
(control/transfer)
96 × 96 Basic control Single-loop standard control
2 points: Pulse voltmm
(1 loop)
Single-loop heating and cooling control age and Pulse voltage/current
Optional functions
Auxiliary
outputs
(SUB)
4
Event
inputs
2
Model
Serial
communications
No
2 points: Current and
Current
E5AR-Q4B
E5AR-C4B
4 points: Pulse voltage and Pulse voltage/current and
Current (2 points)
6
RS-485
E5AR-QC43DB-FLK
2-loop control 2-loop standard control
2-loop heating and cooling control
Single-loop cascade control
Single-loop control with remote SP
Single-loop proportional control
4 points: Pulse volt- 4
age (2 points) and
Pulse voltage/current
(2 points)
4
RS-485
E5AR-QQ43DW-FLK
4-loop control 4-loop standard control
2-loop heating and cooling control
4 points: Current out- 4
put (4 points)
4
RS-485
E5AR-CC43DWWFLK
Position-pro- Single-loop position-proportional control
portional con- (See note.)
trol
(1 loop)
Relay output
(1 open, 1 close)
4
No
E5AR-PR4DF
RS-485
E5AR-PRQ43DF-FLK
4
Relay output
(1 open, 1 close) and
1 current (transfer)
output
Note: Can be switched between close control and floating control.
DeviceNet-compatible Controllers (100 to 240 VAC)
Size
96 × 96
mm
Control type
Control mode
Outputs
(control/transfer)
Basic control 1 loop for standard control
2 points: Pulse volt(1 loop)
Single-loop heating and cooling control age and Pulse voltage/current
Optional functions
Auxiliary Event
outputs inputs
(SUB)
4
2
Model
DeviceNet
communications
Yes
E5AR-Q4B-DRT
2 points: Current and
Current
E5AR-C4B-DRT
4 points: Pulse voltage and Pulse voltage/current and
Current (2 points)
E5AR-QC4B-DRT
2-loop control 2-loop standard control
2-loop heating and cooling control
Single-loop cascade control
Single-loop control with remote SP
Single-loop proportional control
4 points: Pulse voltage (2 points) and
Pulse voltage/current (2 points)
4
None
Yes
E5AR-QQ4W-DRT
4-loop control 4-loop standard control
2-loop heating and cooling control
4 points: Current
(4 points)
4
None
Yes
E5AR-CC4WW-DRT
Position-pro- Single-loop position-proportional conportional con- trol (See note.)
trol
(1 loop)
Relay output
(1 open, 1 close)
4
None
Yes
E5AR-PR4F-DRT
Relay output
(1 open, 1 close) and
1 current (transfer)
output
E5AR-PRQ4F-DRT
Note: Can be switched between close control and floating control.
3
E5AR
DeviceNet-compatible Controllers (24 VAC/DC)
Size
96 × 96
mm
Control type
Control mode
Outputs
(control/transfer)
Basic control 1 loop for standard control
2 points: Pulse volt(1 loop)
Single-loop heating and cooling control age and Pulse voltage/current
Optional functions
Auxiliary Event
outputs inputs
(SUB)
4
2
Model
DeviceNet
communications
Yes
E5AR-Q4B-DRT
2 points: Current and
Current
E5AR-C4B-DRT
4 points: Pulse voltage and Pulse voltage/current and
Current (2 points)
E5AR-QC4B-DRT
2-loop control 2-loop standard control
2-loop heating and cooling control
Single-loop cascade control
Single-loop control with remote SP
Single-loop proportional control
4 points: Pulse voltage (2 points) and
Pulse voltage/current (2 points)
4
None
Yes
E5AR-QQ4W-DRT
4-loop control 4-loop standard control
2-loop heating and cooling control
4 points: Current
(4 points)
4
None
Yes
E5AR-CC4WW-DRT
Position-pro- Single-loop position-proportional conportional con- trol (See note.)
trol
(1 loop)
Relay output
(1 open, 1 close)
4
None
Yes
E5AR-PR4F-DRT
Relay output
(1 open, 1 close) and
1 current (transfer)
output
E5AR-PRQ4F-DRT
Note: Can be switched between close control and floating control.
Inspection Results
■ Accessories (Order Separately)
The Inspection Report can be ordered at the same time as the Digital
Controller using the following model number.
Terminal Cover (Sold Separately)
Inspection Report (Sold Separately)
Descriptions
Inspection Report for E5AR
Model
E5AR-K
Descriptions
Terminal Cover for E5AR
Model
E53-COV14
Unit Label Sheet
Model
Y92S-L1
Rubber Packing
Model
Y92S-P4
Note: The Rubber Packing is provided with the Digital Controller.
4
E5AR
Specifications
■ Ratings
Item
Supply voltage
(See note 1.)
100 to 240 VAC, 50/60 Hz
24 VAC, 50/60 Hz; 24 VDC
Operating voltage range
85% to 110% of rated supply voltage
Power consumption
22 VA max. (with maximum load)
Sensor input (See note 2.)
Thermocouple: K, J, T, E, L, U, N, R, S, B, W
Platinum resistance thermometer: Pt100
Current input: 4 to 20 mA DC, 0 to 20 mA DC (including remote SP input)
Voltage input: 1 to 5 VDC, 0 to 5 VDC, 0 to 10 VDC (including remote SP input)
(Input impedance: 150 Ω for current input, approx. 1 MΩ for voltage input)
Control output
15 VA/10 W max. (with maximum load)
Voltage (pulse) output 12 VDC, 40 mA max. with short-circuit protection circuit (E5AR-QQ@WW-@: 21 mA max.)
Current output
0 to 20 mA DC, 4 to 20 mA DC; load: 500 Ω max. (including transfer output)
(Resolution: Approx. 54,000 for 0 to 20 mA DC; Approx. 43,000 for 4 to 20 mA DC)
Relay output
Position-proportional control type (open, closed)
N.O., 250 VAC, 1 A (including inrush current)
Auxiliary output
Relay Output
N.O., 250 VAC, 1 A (resistive load)
100 Ω to 2.5 kΩ
Potentiometer input
Event input
Contact
Input ON: 1 kΩ max.; OFF: 100 kΩ min.
No-contact
Input ON: Residual voltage of 1.5 V max.; OFF: Leakage current of 0.1 mA max.
Short-circuit: Approx. 4 mA
Remote SP input
Refer to the information on sensor input.
Transfer output
Refer to the information on control output.
Control method
2-PID or ON/OFF control
Setting method
Digital setting using front panel keys or setting using serial communications
Indication method
7-segment digital display and single-lighting indicator
Character Height
PV: 12.8 mm; SV: 7.7 mm; MV: 7.7 mm
Other functions
Depends on model.
Ambient operating temperature
−10 to 55°C (with no icing or condensation)
For 3 years of assured use: −10 to 50°C (with no icing or condensation)
Ambient operating humidity
25% to 85%
Storage temperature
−25 to 65°C (with no icing or condensation)
Note 1: The supply voltage (i.e., 100 to 240 VAC or 24 VAC/VDC) depends on the model. Be sure to specify the required type when ordering.
2: The Controller is equipped with multiple sensor input. Temperature input or analog input can be selected with the input type setting switch. There is basic
insulation between power supply and input terminals, power supply and output terminals, and input and output terminals.
3: Do not use an inverter output as the power supply. (Refer to Safety Precautions for All E5@R Models.)
■ Input Ranges
Platinum Resistance Thermometer, Thermocouple, Current, or Voltage Input
Input type
Name
Temperature
Range
(°C)
Thermocouple
Platinum
Resistance
Thermometer
Pt100
2300
1800
1300
900
800
700
600
400
200
100
0
−100
−200
Setting
K
J
T
E
U
N
R
S
B
1700.0
1700.0
1800.0
W
⎛W/Re ⎞
⎝ 5-26 ⎠
Voltage
[mA]
[V]
2300.0
1300.0
1300.0
850.0
850.0
850.0
500.0
600.0
400.0
400.0
400.0
150.00
20 to
4
20 to
0
5 to
1
5 to
0
10 to
0
15
16
17
18
19
100.0
0.0
−200.0
0
−150.00 −200.0
1
2
−20.0
−100.0
−20.0
3
4
5
−100.0
−200.0
6
7
Minimum setting unit
0.1°C 0.01°C
(SP and alarm)
Input type setting switch
L
Current
8
0.1°C
−200.0
−200.0
9
10
0.0
0.0
11
12
0.0
13
14
(Depends on scaling and
number of decimal places.)
TC.PT
TC.PT
Set to TC.PT.
IN1
TYPE
ANALOG
Set to ANALOG.
IN1
TYPE
ANALOG
The shaded area indicates the setting status at the time of purchase.
5
E5AR
■ Characteristics
Indication accuracy
Thermocouple input with cold junction compensation: (±0.1% of PV or ±1°C, whichever is greater) ±1 digit max. (See note 1.)
Thermocouple input without cold junction compensation: (±0.1% FS or ±1°C, whichever is smaller) ±1 digit (See note 2.)
Analog input: ±0.1% FS ±1 digit max.
Platinum resistance thermometer input: (±0.1% of PV or ±0.5°C, whichever is greater) ±1 digit max.
Position-proportional potentiometer input: ±5% FS ±1 digit max.
Control mode
Standard control (heating or cooling control), heating/cooling control, standard control with remote SP (2-input models only), heating/cooling control with remote SP (2-input models only), cascade standard control (2-input models only), cascade heating/cooling control (2-input
models only), proportional control (2-input models only), position-proportional control (control-valve control models only)
Influence of temperature
Influence of EMS.
(at EN61326-1)
Thermocouple input (R, S, B, W): (±1% of PV or ±10°C, whichever is greater) ±1 digit max.
Other thermocouple input: (±1% of PV or ±4°C, whichever is greater) ±1 digit max.
∗K-type thermocouple at −100°C max.: ±10°C max.
Platinum resistance thermometer: (±1% of PV or ±2°C, whichever is greater) ±1 digit max.
Analog input: (±1%FS) ±1 digit max.
Control period
0.2 to 99.0 s (in units of 0.1 s) for time-proportioning control output
Proportional band (P)
0.00% to 999.99% FS (in units of 0.01% FS)
Integral time (I)
0.0 to 3,999.9 s (in units of 0.1 s)
Derivative time (D)
0.0 to 3,999.9 s (in units of 0.1 s)
Hysteresis
0.01% to 99.99% FS (in units of 0.01% FS)
Manual reset value
0.0% to 100.0% (in units of 0.1% FS)
Alarm setting range
−19,999 to 99,999 EU (See note 3.) (The decimal point position depends on the input type and the decimal point position setting.)
Input sampling period
50 ms
Insulation resistance
20 MΩ min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min (between charged terminals of different polarities)
Vibration resistance
10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions
Shock resistance
100 m/s2, 3 times each in X, Y, and Z directions
Inrush current
100 to 240-VAC models: 50 A max.
24 VAC/VDC models: 30 A max.
Weight
Controller only: Approx. 450 g; Mounting bracket: Approx. 60 g; Terminal cover: Approx. 30 g
Degree of protection
Front panel: NEMA4X for indoor use (equivalent to IP66); Rear case: IP20; Terminals: IP00
Memory protection
Non-volatile memory (number of writes: 100,000)
Applicable standards
UL61010C-1, CSA C22.2 No. 1010-1
EN61010-1 (IEC61010-1): Pollution degree 2/overvoltage category 2
EMC
EMI: EN61326-1 (See note 5.)
Radiated Interference Electromagnetic Field Strength: EN55011 Group 1 Class A
Noise Terminal Voltage:
EN55011 Group 1 Class A
Influence of voltage
EMS: EN61326-1 (See note 5.)
ESD Immunity: EN61000-4-2:
4 kV contact discharge (level 2)
8 kV air discharge (level 3)
10 V/m (amplitude-modulated, 80 MHz to 1 GHz, 1.4 GHz to 2 GHz) (level 3)
2 kV power line (level 3)
2 kV output line (relay output) (level 4)
1 kV measurement line, I/O signal line (level 4)
1 kV communications line (level 3)
Conducted Disturbance Immunity: EN61000-4-6:
3 V (0.15 to 80 MHz) (level 3)
Surge Immunity: EN61000-4-5:
1 kV line to line (power line, output line (relay output)) (level 2)
2 kV line to ground (power line, output line (relay output)) (level 3)
Power Frequency Magnetic Field Immunity: EN61000-4-8: 30 A/m (50 Hz) continuous field
Voltage Dip/Interrupting Immunity: EN61000-4-11:
0.5 cycle, 100% (rated voltage)
Electromagnetic Immunity: EN61000-4-3:
Burst Noise Immunity: EN61000-4-4:
Note 1: K-, T-, or N-type thermocouple at −100°C max.: ±2°C ±1 digit max.
U- or L-type thermocouple: ±2°C ±1 digit max.
B-type thermocouple at 400°C max.: No accuracy specification.
R- or S-type thermocouple at 200°C max.: ±3°C ±1 digit max.
W-type thermocouple: (±0.3% of PV or ±3°C, whichever is greater) ±1 digit max.
2: U- or L-type thermocouple: ±1°C ±1 digit
R- or S-type thermocouple at 200°C max.: ±1.5°C ±1 digit
3: “EU” (Engineering Unit) represents the unit after scaling. If a temperature sensor is used it is either °C or °F.
4: Conditions: Ambient temperature from −10 to 23 to 55°C and voltage of −15% to 10% of rated voltage.
5: Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
6
E5AR
■ Communications Specifications
Transmission path connection
Multiple points
Communications method
RS-485 (two-wire, half duplex)
Synchronization method
Start-stop synchronization
Baud rate
9,600, 19,200, or 384,000 bps
Transmission code
ASCII
Data bit length
7 or 8 bits
Stop bit length
1 or 2 bits
Error detection
Vertical parity (none, even, odd)
Block check character (BCC): CompoWay/F
CRC-16: Modbus
Flow control
None
Interface
RS-485
Retry function
None
Communications buffer
217 bytes
Communications response send wait time 0 to 99 ms, Default: 20 ms
DeviceNet
Item
Specifications
Communications protocol
Conforms to DeviceNet
Communications
functions
Remote I/O
communications
• Master-slave connections (polling, bit-strobe, COS, or cyclic)
• Conform to DeviceNet specifications.
I/O allocations
• Can allocate any I/O data from the Configurator.
• Can allocate any data, such as parameters specific to the DeviceNet and the Digital Controller
variable area.
• Up to 2 blocks for the IN Area, up to a total of 100 words.
• One block for the OUT Area, up to 100 words (first word is always allocated to Output Enable
Bits).
Message
communications
• Explicit message communications
• CompoWay/F communications commands can be sent (commands are sent in explicit message format).
Connection format
Combination of multidrop and T-branch connections (for trunk and drop lines)
Baud rate
DeviceNet: 500, 250, or 125 kbps, or automatic detection of master baud rate
Communications media
Special 5-wire cable (2 signal lines, 2 power lines, and 1 shield line)
Communications distance
Baud rate
Network length
Drop line length
Total drop line length
500 kbps
100 m max. (100 m max.)
6 m max.
39 m max.
250 kbps
250 m max. (100 m max.)
6 m max.
78 m max.
125 kbps
500 m max. (100 m max.)
6 m max.
156 m max.
The values in parentheses apply when Thin Cables are used.
Supply voltage
DeviceNet power supply: 24 VDC
Allowable voltage range
DeviceNet power supply: 11 to 25 VDC
Current consumption
50 mA max. (24 VDC)
Maximum number of nodes that can be
connected
64 (includes Configurator when used)
Maximum number of slaves that can be
connected
63
Error control
CRC error detection
Power supply
Power supplied from DeviceNet communications connector.
7
E5AR
Wiring Terminals
■ E5AR Standard Controller Connections
E5AR-Q4B
E5AR-C4B
A
E5AR-A4B-500
24 VAC/DC 100-240 VAC
+
-
B C D E
2
+
-
3
4
5
6
1
Input power supply
depends on the
model.
100 to 240 VAC
or 24 VAC/DC
(no polarity)
E5AR-A4B-500
24 VAC/DC 100-240 VAC
+
-
E5AR-A4B-500
Auxiliary outputs
B (Relay outputs)
1
2
1
COM
2
SUB1
3
SUB2
4
5
6
COM
Input power supply
depends on the
model.
100 to 240 VAC
or 24 VAC/DC
(no polarity)
SUB3
SUB4
1
COM
2
SUB1
3
SUB2
5
6
1
4
5
6
COM
1
J K
F G H I
E53-ARCC
1
COM
3
PT
4
5
6
K
+
-
-
+
+
I
V
OUT2
Current output
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
(Switch using
output type setting.)
OUT1
Current output
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
(Switch using output
type setting.)
2
EV2
TC
(Current) (Voltage)
(Thermocouple)
(Resistance thermometer)
E5AR-Q43B-FLK
100-240 VAC
B(+)
RS-485
A(-)
2
OUT2
+
Voltage output
3
12 V 40 mA
4
OUT1
+
Voltage output
5
12 V 40 mA or
Current output
6
4-20 mA DC, 500 Ω max.
F
0-20 mA DC, 500 Ω max.
(Switch using output type setting.)
SUB4
1
+
+
-
J K
E5AR-A4B-500
Event inputs
EV1
1
2
EV2
2
3
COM
3
+
4
5
6
F
-
-
-
+
I
+
V
PT
TC
4
5
6
K
(Current) (Voltage)
(Thermocouple)
(Resistance thermometer)
E5AR-C43B-FLK
E5AR-A4B-500
E53-ARQC3
SUB3
2
5
6
E5AR-A4B-500
Event inputs
EV1
E5AR-A4B-500
Auxiliary outputs
B (Relay outputs)
3
4
5
6
2
OUT2
Voltage output 12 V + 3
40 mA
4
OUT1
Voltage output 12 V +
5
40 mA or
Current output
6
4-20 mA DC, 500 Ω max.
F
0-20 mA DC, 500 Ω max.
(Switch using output type setting.)
1
-
3
4
F G H I
B C D E
2
+
3
4
E53-ARQC
+
A
1
A
B C D E
E5AR-A4B-500
Auxiliary outputs
B (Relay outputs)
E5AR-A4B-500
100-240 VAC
A
B C D E
E5AR-A4B-500
Auxiliary outputs
B (Relay outputs)
1
1
COM
1
1
COM
2
2
SUB1
2
2
SUB1
3
4
3
SUB2
SUB2
COM
3
4
3
4
5
6
4
5
6
COM
5
6
1
SUB3
SUB4
5
6
1
2
2
3
4
3
4
5
6
5
6
F G H I
F G H I
J K
E5AR-A4B-500
Event inputs
EV1
EV2
2
COM
3
PT
4
5
6
K
+
-
-
I
+
V
1
+
TC
(Current) (Voltage)
(Thermocouple)
(Resistance thermometer)
E53-ARCC3
+
B(+)
RS-485
A(-) OUT2
Current output
+
4-20mA DC, 500 Ω max.
0-20mA DC, 500 Ω max. (Switch using output
+
type setting.)
OUT1
Current output
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
(Switch using output
type setting.)
1
SUB3
SUB4
J K
E5AR-A4B-500
Event inputs
EV1
1
2
EV2
2
3
COM
3
4
5
6
F
+
-
-
I
+
V
-
PT
+
TC
4
5
6
K
(Current) (Voltage)
(Thermocouple)
(Resistance thermometer)
8
E5AR
E5AR-Q43DB-FLK
E5AR-C43DB-FLK
E5AR-A4B-500
100-240 VAC
E53-ARQC3
+
1
B(+)
RS-485
A(-)
2
OUT2
+
Voltage output
3
12 V 40 mA
4
OUT1
+
Voltage output
5
12 V 40 mA or
Current output
6
4-20 mA DC, 500 Ω max.
F
0-20 mA DC, 500 Ω max.
(Switch using output type setting.)
A
B C D E
E5AR-A4B-500
Auxiliary outputs
B (Relay outputs)
E5AR-A4B-500
100-240 VAC
A
B C D E
E5AR-A4B-500
Auxiliary outputs
B (Relay outputs)
1
1
COM
1
1
COM
2
2
SUB1
2
2
SUB1
3
4
3
SUB2
SUB2
COM
3
4
3
4
5
6
4
5
6
COM
5
6
1
2
3
4
5
6
SUB3
SUB4
E53-ARB4
Event inputs
E
1
EV3
2
EV4
3
EV5
4
5
6
EV6
F G H I
J K
COM
E5AR-A4B-500
Event inputs
EV1
2
COM
3
PT
4
5
6
K
+
-
-
I
+
V
+
TC
2
3
4
5
6
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
(Switch using output
type setting.)
(Current) (Voltage)
(Thermocouple)
(Resistance thermometer)
SUB3
SUB4
E53-ARB4
Event inputs
E
1
EV3
2
EV4
3
EV5
4
5
6
EV6
F G H I
E53-ARCC3
+
B(+)
RS-485
A(-) OUT2
Current output
+
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max. (Switch using output
type setting.)
+
OUT1
Current output
1
EV2
5
6
1
1
J K
COM
E5AR-A4B-500
Event inputs
EV1
1
2
EV2
2
3
COM
3
4
5
6
F
+
-
-
I
+
V
-
PT
+
TC
4
5
6
K
(Current) (Voltage)
(Thermocouple)
(Resistance thermometer)
E5AR-QC43DB-FLK
E5AR-A4B-500
24 VAC/DC 100-240 VAC
+
+
Input power supply depends
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
E53-ARQC3
B(+)
RS-485
+
1
-
A(-)
2
OUT2
+
Voltage output
3
12 V 40 mA
4
OUT1
+
Voltage output
5
12 V 40 mA or
6
Current output
4-20 mA DC, 500 Ω max. F
0-20 mA DC, 500 Ω max.
(Switch using output type setting.)
A
B C D E
E5AR-A4B-500
Auxiliary outputs
B (Relay outputs)
1
1
COM
2
2
SUB1
3
4
3
SUB2
4
5
6
COM
5
6
1
2
3
4
5
6
SUB4
E53-ARB4
Event inputs
E
1
EV3
2
EV4
3
EV5
4
5
6
EV6
F G H I
E53-ARCC
OUT4
Current output
4-20 mA DC, 500 max.
0-20 mA DC, 500 max.
(Switch using output
type setting.)
OUT3
Current output
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
(Switch using output
type setting.)
SUB3
1
+
+
-
J K
COM
E5AR-A4B-500
Event inputs
EV1
1
2
EV2
2
3
COM
3
4
5
6
G
+
-
-
I
+
V
-
PT
+
TC
4
5
6
K
(Current) (Voltage)
(Thermocouple)
(Resistance thermometer)
9
E5AR
E5AR-Q43DW-FLK (2-loop Control)
RS-485
A(-)
2
+
OUT2
3
Voltage output
12 V 40 mA
4
OUT1
+
5
Voltage output
12 V 40 mA or 6
Current output
4-20 mA DC, 500 Ω max. F
0-20 mA DC, 500 Ω max.
(Switch using output type setting.)
F G H I J K
SUB1
3
SUB2
4
5
6
COM
SUB3
SUB4
E53-ARB4
Event inputs
E
1
EV3
2
EV4
3
EV5
4
5
6
EV6
COM
E5AR-A4W-500
+
1
-
-
I
V
-
PT
-
2
3
+
TC
4
5
6
K
-
+
-
Input 1
+
I
V
E53-ARCC3
+
B(+)
RS-485
A(-) OUT2
Current output
+
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max. (Switch using output
type setting.)
+
OUT1
Current output
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
(Switch using output
type setting.)
1
2
3
4
5
6
F
B C D E
F G H I J K
1
COM
2
SUB1
3
SUB2
4
5
6
COM
SUB3
SUB4
E53-ARB4
Event inputs
E
1
EV3
2
EV4
3
EV5
4
5
6
EV6
COM
E5AR-A4W-500
Input 2
+
A
1
2
3
4
5
6
1
2
3
4
5
6
PT
+
TC
(Current) (Voltage)
(Thermocouple)
(Resistance thermometer)
1
-
-
2
+
+
TC
3
Input 2
I
V
PT
-
-
1
COM
2
-
+
1
E5AR-A4W-500
Auxiliary outputs
B (Relay outputs)
100-240 VAC
+
B(+)
B C D E
1
2
3
4
5
6
1
2
3
4
5
6
E5AR-A4W-500
+
A
E53-ARQC3
E5AR-C43DW-FLK (2-loop Control)
E5AR-A4W-500
Auxiliary outputs
B (Relay outputs)
E5AR-A4W-500
100-240 VAC
-
Input 1
+
I
V
PT
+
TC
4
5
6
K
(Current) (Voltage)
(Thermocouple)
(Resistance thermometer)
E5AR-QQ43DW-FLK (2-loop Control)
E5AR-A4W-500
Auxiliary outputs
B (Relay outputs)
E5AR-A4W-500
24 VAC/DC 100-240 VAC
+
-
A
+
Input power supply depend
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
1
2
OUT2
+
3
Voltage output
12 V 40 mA
4
OUT1
+
Voltage output
5
12 V 40 mA or 6
Current output
4-20 mA DC, 500 Ω max. F
0-20 mA DC, 500 Ω max.
(Switch using output type setting.)
F G H I J K
COM
2
SUB1
3
SUB2
4
5
6
COM
SUB3
SUB4
E53-ARB4
Event inputs
E
1
EV3
2
EV4
3
EV5
4
5
6
EV6
COM
E53-ARQC
E5AR-A4W-500
2
OUT4
+
Voltage output
3
12 V 40 mA
4
OUT3
+
Voltage output 12 V
5
40 mA or
Current output
6
4-20 mA DC, 500 Ω max.
G
0-20 mA, DC 500 Ω max.
(Switch using output type setting.)
1
-
-
2
+
TC
3
Input 2
I
+
V
PT
-
-
1
+
A(-)
+
-
-
B(+)
RS-485
1
+
E53-ARQC3
B C D E
1
2
3
4
5
6
1
2
3
4
5
6
-
Input 1
+
I
V
PT
+
TC
4
5
6
K
(Current) (Voltage)
(Thermocouple)
(Resistance thermometer)
10
E5AR
E5AR-CC43DWW-FLK (4-loop Control)
B C D E
3
4
5
6
F
F G H I J K
SUB1
3
SUB2
4
5
6
COM
SUB3
E53-ARQC3
SUB4
B(+)
RS-485
E53-ARB4
Event inputs
E
1
EV3
2
EV4
3
EV5
4
5
6
EV6
COM
E53-ARCC
+
-
-
+
I
-
V
PT
-
+
-
Input 1(K)
Input 3(J)
+
-
Input power supply
depends
on the model.
100 to 240 VAC
or 24 VAC/DC
(no polarity)
V
+
TC
3
-
4
5
6
PT
(Current) (Voltage)
(Thermocouple)
(Resistance thermometer)
A
B C D E
J, K
E5AR-PA4F-500
Auxiliary outputs
B (Relay outputs)
1
1
COM
2
2
SUB1
3
4
3
SUB2
4
5
6
COM
2
3
4
5
6
SUB4
E53-ARB4
Event inputs
E
1
EV3
2
EV4
3
EV5
4
5
6
J K
COM
E5AR-PA4F-500
Potentiometer
O
E53-ARRR
1
OUT1
3
4
5
6
F
COM
2
SUB1
3
SUB2
4
5
6
COM
SUB3
SUB4
E53-ARB4
Event inputs
E
1
EV3
2
EV4
3
EV5
4
5
6
EV6
COM
E5AR-A4WW-500
2
OUT4
+
Voltage output
3
12 V 21 mA
OUT3
4
Voltage output 12 V
+
5
21 mA or
Current output
6
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max. G
(Switch using output type setting.)
W
Relay outputs
250 VAC 1 A
C
+
Closed
-
-
Open
-
+
I
V
+
PT
E5AR-PA4F-500
24 VAC/DC 100-240 VAC
+
+
Input power supply depends
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
SUB3
EV6
F G H I
OUT2
F G H I J K
1
Input 2(K)
Input 4(J)
1
+
I
V
PT
-
Input 1(K)
Input 3(J)
+
I
V
PT
-
2
+
TC
3
-
4
5
6
+
TC
(Current) (Voltage)
(Thermocouple)
(Resistance thermometer)
J, K
E5AR-PRQ43DF-FLK
5
6
1
2
2
1
2
+
TC
+
I
B C D E
E53-ARQC
E5AR-PR4DF
E5AR-PA4F-500
24 VAC/DC 100-240 VAC
+
-
1
1
1
Input 2(K)
Input 4(J)
A(-)
+
+
OUT2
3
Voltage output
12 V 21 mA
4
OUT1
+
5
Voltage output
12 V 21 mA or 6
Current output
4-20 mA DC, 500 Ω max. F
0-20 mA DC, 500 Ω max.
(Switch using output type setting.)
E5AR-A4WW-500
OUT4
Current output
2
4-20 mA DC, 500 Ω max. +
3
0-20 mA DC, 500 Ω max.
(Switch using output
4
type setting.)
+
5
OUT3
Current output
6
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max. G
(Switch using output type setting.)
A
1
2
3
4
5
6
1
2
3
4
5
6
-
2
COM
2
+
1
1
E5AR-A4WW-500
Auxiliary outputs
B (Relay outputs)
100-240 VAC
-
1
2
3
4
5
6
1
2
3
4
5
6
E5AR-A4WW-500
+
A
+
Input power supply depends
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
E53-ARCC3
+
B(+)
RS-485
A(-) OUT2
Current output
+
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max. (Switch using output
+
type setting.)
OUT1
Current output
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
(Switch using output
type setting.)
E5AR-QQ43DWW-FLK (4-loop Control)
E5AR-A4WW-500
Auxiliary outputs
B (Relay outputs)
E5AR-A4W-500
24 VAC/DC 100-240 VAC
+
-
TC
E53-ARQC
A
B C D E
1
1
COM
2
2
SUB1
3
4
3
SUB2
4
5
6
COM
5
6
1
1
2
OUT4
+
Voltage output
3
12 V 40 mA
4
OUT3
Voltage output
+
5
12 V 40 mA or
Current output
6
4-20 mA DC, 500 Ω max.
G
0-20 mA DC, 500 Ω max.
(Switch using output type setting.)
2
B(+)
RS-485
A(-)
3
4
5
6
K
(Current) (Voltage)
(Thermocouple)
(Resistance thermometer)
OUT2
OUT1
SUB3
SUB4
E53-ARB4
Event inputs
E
1
3
4
EV3
2
EV4
3
5
6
EV5
4
5
6
2
EV6
F G H I
E53-ARRR3
1
E5AR-PA4F-500
Auxiliary outputs
B (Relay outputs)
J K
COM
E5AR-PA4F-500
Potentiometer
O
1
2
3
4
5
6
F
W
Relay output
250 VAC 1 A
Closed
C
+
-
-
Open
I
+
V
+
PT
TC
1
2
3
4
5
6
K
(Current) (Voltage)
(Thermocouple)
(Resistance thermometer)
11
E5AR
■ E5AR DeviceNet-compatible Controller Connections
E5AR-Q4B-DRT
E5AR-C4B-DRT
E5AR-A4B-500
24 VAC/DC 100-240 VAC
+
+
Input power supply depends
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
E53-ARQC
1
2
+
OUT2
3
Voltage output
12 V 40 mA
4
OUT1
+
5
Voltage output
12 V 40 mA or 6
Current output
4-20 mA DC, 500 Ω max. F
0-20 mA DC, 500 Ω max.
(Switch using output type setting.)
A
B C D E
E5AR-A4B-500
Auxiliary outputs
B (Relay outputs)
1
1
COM
2
2
SUB1
3
4
3
SUB2
4
5
6
COM
5
6
1
5
6
F G H I
J K
E5AR-A4B-500
Event inputs
EV1
EV2
2
COM
3
+
-
-
I
+
V
1
+
TC
PT
4
5
6
K
(Current) (Voltage)
(Thermocouple)
(Resistance thermometer)
B C D E
E5AR-A4B-500
Auxiliary outputs
B (Relay outputs)
1
1
COM
2
2
SUB1
3
4
3
SUB2
4
5
6
COM
2
3
2
4
5
6
F
3
4
1
OUT2
Current output
+
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max. (Switch using output
type setting.)
+
OUT1
Current output
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
(Switch using output
type setting.)
A
5
6
1
E53-ARCC
SUB4
DeviceNet Connector
Red (V+)
White (CAN H)
−
(Shield)
Blue (CAN L)
Black (V−)
3
4
+
Input power supply depends
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
SUB3
E53-ARDRT
2
E5AR-A4B-500
24 VAC/DC 100-240 VAC
+
SUB3
SUB4
E53-ARDRT
DeviceNet Connector
Red (V+)
White (CAN H)
−
(Shield)
Blue (CAN L)
Black (V−)
5
6
F G H I
J K
E5AR-A4B-500
Event inputs
EV1
2
COM
3
+
-
-
I
+
V
1
EV2
-
PT
+
TC
4
5
6
K
(Current) (Voltage)
(Thermocouple)
(Resistance thermocouple)
E5AR-QC4B-DRT
E5AR-A4B-500
24 VAC/DC 100-240 VAC
+
+
Input power supply depends
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
E53-ARQC
1
2
+
OUT2
3
Voltage output
12 V 40 mA
4
OUT1
+
5
Voltage output
12 V 40 mA or 6
Current output
4-20 mA DC, 500 Ω max. F
0-20 mA DC, 500 Ω max.
(Switch using output type setting.)
A
B C D E
E5AR-A4B-500
Auxiliary outputs
B (Relay outputs)
1
1
COM
2
2
SUB1
3
4
3
SUB2
4
5
6
COM
5
6
1
SUB3
SUB4
E53-ARDRT
2
DeviceNet Connector
Red (V+)
White (CAN H)
−
(Shield)
Blue (CAN L)
Black (V−)
3
4
5
6
F G H I
E53-ARCC
OUT4
Current output
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max. +
(Switch using output
type setting.)
OUT3
+
Current output
4-20 mA DC, 500 Ω max. 0-20 mA DC, 500 Ω max.
(Switch using output
type setting.)
1
J K
E5AR-A4B-500
Event inputs
EV1
1
2
EV2
2
3
COM
3
4
5
6
G
+
-
-
I
+
V
-
PT
+
TC
4
5
6
K
(Current) (Voltage)
(Thermocouple)
(Resistance thermometer)
12
E5AR
E5AR-QQ4W-DRT (2-loop Control)
E5AR-CC4WW-DRT (4-loop Control)
E5AR-A4W-500
Auxiliary outputs
B (Relay outputs)
B C D E
2
+
OUT2
3
Voltage output
12 V 40 mA
4
OUT1
+
5
Voltage output
12 V 40 mA or 6
Current output
4-20 mA DC, 500 Ω max. F
0-20 mA DC, 500 Ω max.
(Switch using output type setting.)
SUB1
3
SUB2
4
5
6
COM
SUB4
E53-ARQC
DeviceNet Connector
Red (V+)
White (CAN H)
−
(Shield)
Blue (CAN L)
Black (V−)
+
1
-
-
-
2
+
TC
3
Input 2
+
+
I
V
PT
-
-
2
OUT4
+
Voltage output
3
12 V 40 mA
OUT3
4
Voltage output 12 V
+
5
40 mA or
Current output
6
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max. G
(Switch using output type setting.)
4
5
6
K
-
Input 1
+
I
V
+
TC
PT
(Current) (Voltage)
(Thermocouple)
(Resistance thermometer)
E5AR-PR4F-DRT
E5AR-PA4F-500
24 VAC/DC 100-240 VAC
+
+
-
Input power supply
depends on the model.
100 to 240 VAC
or 24 VAC/DC
(no polarity)
A
B C D E
E5AR-PA4F-500
Auxiliary outputs
B (Relay outputs)
1
1
COM
2
2
SUB1
3
4
3
SUB2
4
5
6
COM
5
6
1
SUB4
DeviceNet Connector
Red (V+)
White (CAN H)
−
(Shield)
Blue (CAN L)
Black (V−)
5
6
F G H I
J K
E5AR-PA4F-500
Potentiometer
O
E53-ARRR
1
OUT1
3
4
5
6
F
3
4
5
6
F
COM
2
SUB1
3
SUB2
4
5
6
COM
SUB3
SUB4
E53-ARDRT
F G H I J K
DeviceNet Connector
Red (V+)
White (CAN H)
−
(Shield)
Blue (CAN L)
Black (V−)
E5AR-A4WW-500
1
1
OUT4
Current output
2
4-20 mA DC, 500 Ω max. +
3
0-20 mA DC, 500 Ω max.
(Switching by output 4
type setting)
+
5
OUT3
Current output
6
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max. G
(Switch using output type setting.)
W
Relay output
250 VAC 1 A
C
+
Closed
-
-
Open
-
+
I
V
+
PT
E5AR-PA4F-500
24 VAC/DC 100-240 VAC
+
+
Input power supply depends
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
SUB3
E53-ARDRT
3
4
OUT2
2
1
Input 2(K)
Input 4(J)
+
I
V
PT
-
Input 1(K)
Input 3(J)
+
I
V
PT
-
2
+
TC
3
-
4
5
6
+
TC
(Current) (Voltage)
(Thermocouple)
(Resistance thermometer)
J, K
E5AR-PRQ4F-DRT
2
2
1
E53-ARCC
E5AR-A4W-500
1
E53-ARCC
OUT2
Current output
+
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max. (Switch using output
+
type setting.)
OUT1
Current output
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
(Switch using output
type setting.)
B C D E
1
2
3
4
5
6
1
2
3
4
5
6
SUB3
E53-ARDRT
F G H I J K
A
+
Input power supply depends
on the model.
100 to 240 VAC or 24 VAC/DC
(no polarity)
-
1
COM
2
+
4
5
6
1
2
3
4
5
6
E53-ARQC
1
E5AR-A4WW-500
Auxiliary outputs
B (Relay outputs)
-
A
+
Input power supply depends 1
on the model.
2
100 to 240 VAC
3
or 24 VAC/DC (no polarity)
E5AR-A4WW-500
24 VAC/DC 100-240 VAC
+
+
E5AR-A4W-500
24 VAC/DC 100-240 VAC
+
-
TC
E53-ARQC
A
B C D E
1
1
COM
2
2
SUB1
3
4
3
SUB2
4
5
6
COM
5
6
1
1
2
OUT4
+
Voltage output
3
12 V 40 mA
4
OUT3
Voltage output
+
5
12 V 40 mA or
Current output
6
4-20 mA DC, 500 Ω max.
G
0-20 mA DC, 500 Ω max.
(Switch using output type setting.)
5
6
F G H I
2
2
3
3
(Current) (Voltage)
(Thermocouple)
(Resistance thermometer)
J K
E5AR-PA4F-500
Potentiometer
O
1
OUT1
SUB4
DeviceNet Connector
Red (V+)
White (CAN H)
−
(Shield)
Blue (CAN L)
Black (V−)
3
4
E53-ARRR
OUT2
SUB3
E53-ARDRT
2
1
4
5
6
K
E5AR-PA4F-500
Auxiliary outputs
B (Relay outputs)
4
5
6
F
W
Relay output
250 VAC 1 A
Closed
C
+
-
-
Open
I
+
V
+
PT
TC
1
2
3
4
5
6
K
(Current) (Voltage)
(Thermocouple)
(Resistance thermometer)
13
E5AR
Nomenclature
E5AR
DeviceNet-compatible Controllers, Rear Panel
Operation
Indicators
Channel
Indicator
MS/NS indicators
Top: MS
Bottom: NS
No. 1 Display
No. 2 Display
Bar Graph
DeviceNet communications
connector
Used to connect the
DeviceNet communications
cables.
The DeviceNet
communications power is
also supplied through this
connector.
The connector included with
the DeviceNet-compatible
Controllers is the FKC
2.5/5-STF-5.08 AU M
(PHOENIX CONTACT).
No. 3 Display
Function Key 1/
Auto/Manual Key
Function Key 2/
Channel Key
Level Key
Mode Key
Down Key
Up Key
Dimensions
Note: All units are in millimeters unless otherwise indicated.
E5AR
110
95 (99)*
11.5
96
3
Terminal cover (E53-COV14; sold separately)
2
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
111
96
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
Crimp terminal size: M3
Mounting Bracket (Accessory)
Panel Cutouts
* The value in parentheses is for
DeviceNet-compatible Controllers.
92+0.8
0
110 min.
92+0.8
0
120 min.
• Recommended panel thickness is 1 to 8 mm.
• Group mounting is not possible. (Maintain the
specified mounting space between Controllers.)
• When two or more Controllers are mounted,
make sure that the surrounding temperature
does not exceed the allowable operating
temperature specified in the specifications.
14
E5AR
■ Accessories (Order Separately)
Terminal Cover
E53-COV14 (for E5AR)
95
95
28.5
10.1
Unit Label Sheet
Y92S-L1
11.8
4.8
Rubber Packing
Y92S-P4 (for DIN96 × 96)
Order the Rubber Packing separately if it becomes lost or damaged. (Refer to page 4.)
The Rubber Packing can be used to achieve an IP66 degree of protection.
(Deterioration, shrinking, or hardening of the rubber packing may occur depending on the operating environment.
Therefore, periodic replacement is recommended to ensure the level of waterproofing specified in NEMA4. The time for
periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider one year
a rough standard. OMRON shall not be liable for the level of water resistance if the customer does not perform periodic
replacement.)
The Rubber Packing does not need to be attached if a waterproof structure is not required.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
15
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2015.8
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2015 All Right Reserved.