Download

Datasheet
USI 16
M i d g e t F u s e Te r m i n a l s
Weidmuller offers DIN rail mounted terminal
blocks for the popular 13/32” x 1½” midget fuses.
Compact and touch safe, these terminals meet
CSA, UL and IEC requirements.
NEW
Features:
• CSA certified for 600V, 30A max.
• UL rated 600V, 30A max.
(terminals without indication only)
• 1, 2, 3, and 4 pole versions available
• metal foot for secure mounting on
35mm DIN rail
• only 17.5mm wide per pole
• lever mechanism for quick and safe fuse
replacement
• vented housing to reduce internal heating
and extend fuse life
• optional fuse failure indication available
United States
Canada
Mexico
Weidmuller Inc.
Weidmuller Ltd.
Weidmuller, S.A. de C.V.
821 Southlake Blvd.
10 Spy Court
5 Sur No. 4311
Richmond, Virginia 23236
Markham, Ontario L3R 5H6
Col. Huexotitla
Telephone: (800) 849-9343
Telephone: (800) 268-4080
72534 Puebla, Pue. Mexico
Facsimile: (804) 379-2593
Facsimile: (905) 475-2798
Telephone: (22) 37 2549
Email: [email protected]
Email: [email protected]
Facsimile: (22) 43 1981
Website: www.weidmuller.com
Website: www.weidmuller.ca
Email: [email protected]
USI 16
Specifications:
Dimensions (LxWxH)
Moulding material
Wire Size
Mounting
Rating
86mm x 17.5mm x 66mm
polyamide, UL94 -V2
18 - 6 AWG
TS35 (35mm) DIN rail
CSA 600V 30A
UL 600V 30A max.
13
/32” x 1½” midget fuses, including “CC” types
Fuse Size
NOTE: Disconnect fuse terminals are NOT designed to be operated under load
Ordering Data:
Catalog Numbers
without indication
with LED indication*
1
2
3
4
991073
991074
991075
991076
991077
991078
991079
991080
pole
pole
pole
pole
with neon indication
for 120-600V
990975
991627
991770
-
* Indicator is flashing LED which illuminates if the fuse blows. A unique feature of the indicator circuitry is that under some circumstances it is possible to get a fuse failure indication even when the load is disconnected. This is accomplished by capacitively coupling the indicator signal to the system neutral or, in the case of 3 phase circuits, to another phase. The rate of flash of the
indicator is proportional to the line voltage and whether the load is connected or not. Typical flash rates and indicator current
draws are as follows:
120Vac, load
load
220Vac, load
load
connected:
open:
connected:
open:
50µA,
10µA,
125µA,
20µA,
100 per minute
20 per minute
150 per minute
40 per minute
The indicator is optimised for 220Vac operation and may be dim at other voltages. An alternative would be Weidmuller’s VM8
voltage monitor (consult factory for details.)
Dimensional drawing:
71mm
80mm
66mm
60mm
44mm
64mm
40mm
68mm to bottom of rail
45mm
17.5mm
DIN rail 35x7.3mm
80mm
86mm max
2