SAK-Series SAK-Series Appendix SAK-Series TS 35 A SAK-Series TS 32 B SAK-Series combination foot TS 35 + TS 32 C SAK-Series for special applications D AKZ-Series TS 15 E Multi-pole terminal strips F KLBÜ shielded connection G Busbars / Terminal rails H Accessories I Tools and ferrules J Marking systems K Technical appendix W Index X Search according to type or order number, Addresses worldwide I SAK – The Classic “SAK – A real classic that became synonymous with connection technology” Or “Once upon a time there was a company called Weidmüller that created the best terminals in the world using plastic and metal”. Weidmüller has an interesting story to tell about SAK terminals. SAK (German abbreviation for „side-by-side mountable termi nals“) is the designation for a terminal that has proven itself on the market for more than 55 years. Using the side-by-side mounting principal, electrical terminals made of plastic replaced breakable porcelain constructions in switchgear cabinets. One could as a result say: „SAK was the first family of terminals in the world that helped the electrical industry make a technological breakthrough”. Further developments of the terminals and passive connection technology form the Weidmüller group‘s traditional core business. SAK wire connections – synonymous with reliable connections and product variety. This long-term experience in the market enabled many improvements to be made. Nobody can claim that any other terminal on this earth has had as much know-how put into it as the SAK. A great deal of know-how has been put into the inconspicuous insulating body with „clamping function” for electrical wires. This is because terminals have to withstand all kinds of unfavourable conditions. The connections system is chosen according to the respective application. When looked at more closely, the demands made of an allegedly trivial component such as a terminal are considerable. Appropriately, the EN 60 947-7-1 defines terminals and cable connectors as equipment for connecting and joining electrical wires. Terminals can be mounted side-by-side or staggered, have two or several, independently functioning connection points, and are insulated both from one another and their mountings. They are mounted, for example, onto mounting rails. II As well as joining the wiring, terminals are also equipped with further functions: when fitted with markers, terminals make it possible to clearly arrange „electrical installations”. Moreover, they create a defined connection point that can be extended as required. From this point, the wiring is routed to individual devices in the switchgear cabinet or from the switchgear cabinet to the devices. Terminal blocks increase serviceability, because electrical measurements can be carried out on them, targeted circuits can be opened or protected with appropriate protective elements. Furthermore, cross-connections can be used to distribute potentials. A clamping yoke system is used for securing the wiring in SAK terminals (see figure 1). The tension clamp system optimally combines the specific features of steel and copper. This system has proven itself millions of times over in electrical installations: in rough and aggressive industrial atmospheres, in power stations, ships and railway vehicles as well as in building automation. The clamping yoke and the terminal screw used in Weidmüller’s clamping yoke system are made from case-hardened steel. The clamping yoke unit with a highstrength terminal screw produces the required contact force and presses the conductor against the busbar, which is made either of copper or high-quality brass. The latter being tin coated. Figure 1 SAK – The Classic High contact forces with the patented connection system Plastics for terminals – thermoplastics and thermosetting plastics Thermal plastics are a polyamide (PA), and are one of the most frequently used technical plastics. The advantage of this material is its good electrical and mechanical characteristics, its flexibility and its lack of fracture susceptibility. In addition, this material offers good fire resistance due to its chemical structure without the need for added flameproofing substances. Engineers speak of a so-called „inherent flame protection”. The continuous operating temperature of the SAK range is 100 °C, and at the same time offering V2 fire resistance according to UL 94. This ensures a „close fitting” and permanent contact with a low contact resistance. A gas-tight, vibration-resistant connection is created between the conductor and the busbar. Because even a very good electrically conducting material is only as good as the contact force applied. Weidmüller’s patented connection system guarantees high contact forces. This means that it is predestined for use in corrosion-promoting environments; in addition, it is maintenance free. A further aspect is mounting and maintenance on an international scale, made possible by the world-renowned screw connection. One decisive factor for a perfect terminal is the insulating material. In order to meet the demands placed on terminals, it is necessary to use different insulating materials that are tailor-made for the application – thermoplastic or thermosetting plastic. All insulating materials used by Weidmüller are free from noxious substances and contain no paint pigments based on cadmium. The SAK family especially offers the option of specifically coordinating the terminals with material requirements in mind. In this case, Weidmüller offers the same construction with different insulation materials. Thermosetting plastics possess high dimensional stability, absorb a negligible amount of water, have a very high tracking resistance and excellent fire resistance. The continuous operating temperature is higher in comparison with that of thermoplastics. With increased thermal load, the dimensional stability of thermosetting plastics is better than that of thermoplastics. Their disadvantage: Thermosetting plastics have less flexibility in comparison with thermoplastics. A further advantage of the SAK family is the large choice of different locking mechanisms. Its mounting rail designs (MR) offer the user the highest possible degree of convenience: TS 35 and TS 32 as well as a combi foot. Technical background to the screw connection A spring element forms the basis for Weidmüller’s clamping yoke. Turning the terminal screw expands the upper flank of thread slightly, and in so doing locks itself in position. This construction efficiently compensates all expansions in the diameter of the wire (temperature fluctuations). This has the following advantages: of course the terminals age when in use; nevertheless, the terminal point does not yield. Consequently, it is not necessary to retighten the terminal screw at a later date nor does the wire become loose: it is resistant to vibration. The voltage drop remains consistently low. Weidmüller’s technology is completely maintenance free. Separating the electrical and mechanical functions means that we use steel for a high contact force, and the good electrical conducting properties of copper for a low voltage drop. III SAK – The Classic PS STB TSch BS BS VL2 QL VHQ VH BSK AD4 DEK AP EW 35 TS 35 TW The construction of the clamping yoke has been designed in such a manner to ensure that the connection between the wire and the busbar is gas-tight. The surface of the connection must make up at least 75 % of the surface as a whole. Electricity is conducted with 100 % efficiency at these points, because in creased resistances due to soiling of the connection points do not arise. The SAK family is designed for wire cross-sections from 0.08 mm2 to 240 mm2. Legend PS STB TSch BS QL VH Q EW 35 TS 35 VL BSK AD 4 DEK AP TW Test plug Test socket screw Small partition Fixing srew Cross-connection link Connection sleeve End brackets Mounting rail Connection link Fixing srew Cover Markers End plate Partition A rundown on the SAK: • PA 6.6, KrG Two different materials that can be used, depending on the application, at 100 °C or 130 °C. • Three different types of clip-on foot for mounting rail designs 32, 35 or a combination of both. • Maintenance free and vibration-resistant There is no need to check the terminal point, because the patented clamping yoke construction ensures that the screws remain captive in the terminal. Separating the tasks completed by the components offers the following advantages: • Low voltage drop and gas-tight enclosed (electrical components). Perfect busbars in combination with a special surface treatment in conjunction with a high interference-fit at the terminal point. • High contact forces, not reliant on the cross-section (mechanical components). The clamping yoke is made of casehardened steel that, due to its design, can compensate any dimensional instability of the electrical wire. IV SAK-Series SAK-Series The advantages of all SAK modular terminals: • Separation of electrical and mechanical functions: – steel clamping yoke for the mechanical function – copper busbar for the electrical function • Maintenance-free and vibration-proof screw connection • Low voltage drop and gas-tight contact point • High contact forces, not reliant on the cross-section • Three different clip-on foot designs available • Various insulation materials • Large selection of special terminals with diverse connection systems • Large range of accessories available PA 6.6 material Cross-sections from 0.5 mm2 to 35 mm2 Combination foot TS 32 and TS 35 rail in one Cross-sections from 0.5 mm2 to 95 mm2 Temperature ranges and materials 100 °C – PA 6.6 130 °C – KrG Special foot for TS 35 Special foot for TS 32 Product range Clamp type Rated cross-section 2.5 mm2 4 mm2 6 mm2 10 mm2 16 mm2 35 mm2 Modular feed-through terminals PA 6.6 / TS 32 • • • • • • KRG / TS 32 PA 6.6 / TS 35 KRG / TS 35 PA 6.6 / comb. foot PA 6.6 / TS 15 • • • • • • • • • • • • • • • • • • • • • • • • • • • Push-on connection Spring connection Solder connection • • • • • • • • • • • • • Modular 2-tier terminals Modular PE terminals PA 6.6 / TS 32 • • PA 6.6 / TS 35 • • PA 6.6 / TS 15 Modular fuse terminals PA 6.6 / TS 32 • • PA 6.6 / TS 35 KrG / TS 32 KrG / TS 35 PA 6.6 / TS 15 Flat blade connection • • • • • • • • • • • • • • PA 6.6 / comb. foot Modular 2-tier fuse terminals PA 6.6 / TS 32 • PA 6.6 / TS 35 • PA 6.6 / comb. foot Modular disconnect terminals TS 35 • • • PA 6.6 / TS 15 Modular 2-tier disconnect terminals Modular ceramic terminals • • • • • • V VI SAK-Series TS 35 Contents SAK-Series TS 35 SAK-Series TS 35 Feed-through modular terminals TS 35 / PA A.2 TS 35 / KrG A.7 Terminals with spring-loaded cable clamps TS 35 / PA A.11 Two-tier modular terminals TS 35 / PA A.12 Modular PE terminals TS 35 / PA A.14 Disconnect terminals TS 35 / PA A.18 TS 35 / KrG A.20 Fuse terminals TS 35 / PA A.22 TS 35 / KrG A.24 Fuse inserts and gauge rings for Weidmüller fuse terminals A.28 Installation terminals TS 35 / PA A.30 Test-disconnect terminals TS 35 / KrG A.32 Terminals for temperature measuring circuits TS 35 / PA A.34 Terminals with screw-less connections With tab connection TS 35 / PA A.36 With solder connection TS 35 / PA A.40 Special terminals – SAKG TS 35 / KrG A.42 Stud Terminal – KST TS 35 / PA A.48 Terminals with electronic components TS 35 / PA A.50 Earth conductor isolating terminals A.57 A.1 A SAK-Series TS 35 Feed-through modular terminals A SAKD 2.5/35 TS 35 / PA 2.5 mm² SAK 2.5 2.5 mm² In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data 5 x 44 x 38 30 / 4 0.33...4 6.1 x 44.5 x 40 41 / 6 0.13...6 IEC 60947-7-1 Rated data Rated voltage V Rated current A Rated cross-section mm² Rated impulse voltage / Pollution severity kV/Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded mm² flexible / Stranded wire with end ferrules mm² Tightening torque range (clamping screw) Stripping length / Blade size mm/2 conductors with same cross-section (H05V/H07V) solid / stranded mm² flexible / Stranded wire with end ferrules mm² Note IEC 500 24 2.5 IEC 60947-7-1 UL CSA 300 300 20 20 AWG 22...12 AWG 22...12 6/3 A2 / V2 Ex e II IEC 800 24 2.5 T II 2 G D UL CSA EN 60079-7 600 600 550 20 25 21 AWG 22...12 AWG 26...10 2.5 8/3 A3 / V2 KEMA 97ATEX1798 U ?ru#i~a Rated connection 0.5...6 / 0.5...4 0.5...4 / 0.5...4 0.4...0.6 Nm (M 2.5) 10 / 0.6 x 3.5 mm ru#a Rated connection 0.5...4 / 0.5...4 0.5...4 / 0.5...2.5 0.4...0.6 Nm (M 2.5) 10 / 0.6 x 3.5 mm 0.5...0.75 0.5...0.75 / 0.5...0.75 With twin ferrules ZH 0.5 to ZH 1.5, rated voltage is 690 V. With twin ferrules ZH 0.5 to ZH 1.5, rated voltage is 690 V. Type Qty. Order No. Type Qty. Order No. SAKD 2.5/35 100 0268860000 SAK 2.5/35 100 0380460000 SAKD 2.5/35 BL 100 0268880000 SAK 2.5/35 BL 100 0380480000 Ordering data Version beige Blue Note Accessories Screwable cross-connection current Qty. Order No. Type current Qty. 2-pole Type Q 2 SAKD2.5N 24 A 50 0367800000 Q 2 SAK2.5 41 A 50 0337000000 Order No. 3-pole Q 3 SAKD2.5N 24 A 50 0367900000 Q 3 SAK2.5 41 A 50 0337100000 4-pole Q 4 SAKD2.5N 24 A 50 0368000000 Q 4 SAK2.5 41 A 50 0337200000 10-pole Q 10 SAKD2.5N 24 A 20 0368100000 Q 10 SAK2.5 41 A 20 0368700000 20 0180400000 PS 2.3 RT 20 0180400000 50 0215700000 STB 8.5/5/2.3/M3 SAK2.5 50 0280600000 Connecting sleeve Mounting screw Lock washer Switchable link Switchable link Connecting sleeve Mounting screw Width Testing / Checking Test plug Socket PS 2.3 RT 5.4 mm STB 8.5/D4/2.3/M2.5 AKZ Width 5.4 mm End plate / Partition plate beige Blue beige Blue AP SAKD2.5N 1.5 mm 20 0150960000 AP SAK2.5 1.5 mm 20 0279560000 AP SAKD2.5N BL 1.5 mm 20 0150980000 AP SAK2.5 BL 1.5 mm 20 0279580000 TW SAKD2.5N 1.5 mm 20 0191860000 TW SAK2.5 2.5 mm 20 0302860000 TW SAKD2.5N BL 1.5 mm 20 0191880000 TW SAK2.5 BL 1.5 mm 20 0302880000 5 mm 100 0366860000 TSCH 1 2 mm 100 0319160000 50 0297900000 100 0128900000 Small partition Small partition TSCH 3 SAKD2.5 N Cover / warning label AD 3 SAK2.5 Cover / warning label BFSC M3X22 PA/RT Mounting screw (plastic) Marking systems (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.2 DEK 5/5 / SCHT 7 DEK 5/6 / SCHT 7 SAK 4 4 mm² SAK 6 6 mm² SAK 10 10 mm² SAK-Series TS 35 Feed-through modular terminals A 6.5 x 45 x 44 41 / 6 0.13...6 8 x 45 x 44 57 / 10 0.33...10 IEC 60947-7-1 Ex e II IEC 800 32 4 T II 2 G D UL CSA EN 60079-7 600 600 550 30 36 28 AWG 22...12 AWG 26...10 4 8/3 A4 / V2 KEMA 97ATEX1798 U ?ru#i~a Rated connection 0.5...6 / 0.5...4 0.5...4 / 0.5...4 0.5...1.0 Nm (M 3) 12 / 0.6 x 3.5 mm 10 x 45 x 51.5 76 / 16 1.5...16 IEC 60947-7-1 Ex e II IEC 800 41 6 T II 2 G D UL CSA EN 60079-7 600 600 550 40 47 36 AWG 22...8 AWG 20...8 6 8/3 A5 / V2 KEMA 97ATEX1798 U ?ru#i~a Rated connection 0.5...10 / 0.5...6 0.5...10 / 0.5...6 0.8...1.6 Nm (M 3.5) 12 / 4.0 x 0.8 mm IEC 60947-7-1 Ex e II IEC 800 57 10 T II 2 G D UL CSA EN 60079-7 600 600 550 60 65 50 AWG 14...6 AWG 16...6 10 8/3 B6 / V2 KEMA 97ATEX1798 U ?ru#i~a Rated connection 1.5...10 / 1.5...16 1.5...16 / 1.5...10 2.0...4.0 Nm (M 4) 12 / 1.0 x 5.5 mm 1.5...1.5 0.5...1.5 With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V. For AWG 8-7 and AWG 8-19, tightening torque is 1.21.4 Nm When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V. Type Qty. Order No. Type Qty. Order No. Type Qty. Order No. SAK 4/35 100 0443660000 SAK 6/35 PA 100 0380560000 SAK 10/35 100 0443760000 SAK 4/35 BL 100 0443680000 SAK 6/35 PA/BL 100 0380580000 SAK 10/35 BL 100 0443780000 Type With AWG 6 and H07V-R10 conductors, an increased MD torque of 1.4 to1.6 Nm should be used. A higher torque of 2 to 2.4 Nm is necessary when using H07V-R16 and AWG 6 conductors. current Qty. Order No. Type current Qty. Order No. Type current Qty. Q 2 SAK4 41 A 50 0336700000 Q 2 SAK6N 32 A 50 0456700000 Q 2 SAK10 57 A 50 0457100000 Q 3 SAK4 41 A 50 0336800000 Q 3 SAK6N 57 A 50 0456800000 Q 3 SAK10 57 A 50 0457200000 Q 4 SAK4 41 A 50 0336900000 Q 4 SAK6N 57 A 50 0456900000 Q 4 SAK10 57 A 50 0457300000 Q 10 SAK4 41 A 20 0368800000 Q 10 SAK6N 32 A 20 0457000000 Q 10 SAK10 57 A 20 0457400000 VL 2 SAK4 32 A 50 0197000000 VL 2 SAK6N/SAKT 32 A 50 0194700000 VL 2 SAK6/10/SAKB 32 A 50 0135900000 50 0285100000 VH 19/5/3.5 SAK4-16 50 0285100000 VH 19/5/3.5 SAK4-16 50 0285100000 100 0292500000 BFSC M3X25 100 0292500000 BFSC M3X25 100 0292500000 20 0299600000 50 0169900000 VH 19/5/3.5 SAK4-16 BFSC M3X25 Width PS 4 F.STB 4 7.6 mm STB 14/D5/2.3/M3 SAK2.5 Width 20 0299600000 PS 4 F.STB 4 50 0168600000 STB 14/D6/4/M3 SAK10 7.6 mm Order No. Width 20 0299600000 PS 4 F.STB 4 50 0169900000 STB 14/D6/4/M3 SAK10 7.6 mm AP SAK4-10 1.5 mm 20 0117960000 AP SAK4-10 1.5 mm 20 0117960000 AP SAK4-10 1.5 mm 20 0117960000 AP SAK4-10 BL 1.5 mm 20 0117980000 AP SAK4-10 BL 1.5 mm 20 0117980000 AP SAK4-10 BL 1.5 mm 20 0117980000 TW 4 SAK4-10 1.5 mm 20 0130160000 TW 4 SAK4-10 1.5 mm 20 0130160000 TW 4 SAK4-10 1.5 mm 20 0130160000 TW 4 SAK4-10 BL 1.5 mm 20 0130180000 TW 4 SAK4-10 BL 1.5 mm 20 0130180000 TW 4 SAK4-10 BL 1.5 mm 20 0130180000 2 mm 100 0319160000 TSCH 1 2 mm 100 0319160000 TSCH 1 2 mm 100 0319160000 50 0285300000 AD 4 SAK6N 50 0196600000 AD 4 SAK10 50 0178600000 100 0128900000 BFSC M3X22 PA/RT 100 0128900000 BFSC M3X22 PA/RT 100 0128900000 TSCH 1 AD 4 SAK4 BFSC M3X22 PA/RT DEK 5/6,5 / SCHT 7 DEK 5/8 / SCHT 7 DEK 5/5 When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V. A.3 SAK-Series TS 35 Feed-through modular terminals A SAK 16 TS 35 / PA 16 mm² SAK 35/35 35 mm² In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data 12 x 50 x 57.5 76 / 16 2.5...16 18 x 58 x 60 150 / 50 2.5...50 IEC 60947-7-1 Rated data Rated voltage V Rated current A Rated cross-section mm² Rated impulse voltage / Pollution severity kV/Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded mm² flexible / Stranded wire with end ferrules mm² Tightening torque range (clamping screw) Stripping length / Blade size mm/2 conductors with same cross-section (H05V/H07V) solid / stranded mm² flexible / Stranded wire with end ferrules mm² Note Ex e II IEC 1000 76 16 T II 2 G D UL CSA EN 60079-7 600 600 690 80 87 66 AWG 12...4 AWG 14...6 16 8/3 B6 / V2 KEMA 97ATEX1798 U ?ru#i~a Rated connection 2.5...16 / 4...16 4...16 / 4...16 2.0...4.0 Nm (M 4) 15 / 1.0 x 5.5 mm IEC 60947-7-1 Ex e II IEC 1000 125 35 T II 2 G D UL CSA EN 60079-7 600 600 550 105 145 109 AWG 12...2 AWG 12...2 35 8/3 B8 / V2 KEMA 97ATEX1798 U ru#i~a Rated connection 2.5...16 / 4...50 2.5...35 / 2.5...35 4.0...5.0 Nm (M 6) 18 / 6.5 x 1.2 mm 2.5...10 / 10...16 2.5...16 / 2.5...16 Twin wire end ferrules ZH 2.5 - ZH 16 can be used. The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stranded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used. Ordering data Version Type beige Blue Note Order No. Type SAK 16/35 PA Qty. 50 0380660000 SAK 35/35 Qty. 20 0380760000 Order No. SAK 16/35 PA/BL 50 0380680000 SAK 35/35 BL 20 0380780000 If QIs are aligned side by side, then a TW/AP must be used. It is possible to use twin ferrules with identical rated voltages (LAB 13090). Type Accessories current Qty. Order No. Type current Qty. 2-pole Q 2 SAK16 76 A 50 0457500000 QL 2 SAK35 110 A 20 0123600000 3-pole Q 3 SAK16 76 A 50 0457600000 QL 3 SAK35 110 A 20 0123700000 4-pole Q 4 SAK16 76 A 50 0457700000 QL 4 SAK35 110 A 20 0123800000 10-pole Q 10 SAK16 76 A 20 0457800000 QL 10 SAK35 110 A 20 0338600000 VH 17/8/5 SAK35 50 0267000000 BFSC M4X30 50 0267100000 100 0136400000 Screwable cross-connection Connecting sleeve Mounting screw SS M4 Lock washer D 128-A 4 Order No. Switchable link Switchable link Connecting sleeve Mounting screw VL 2 SAK16/SAKA 57 A VH 19/5/3.5 SAK4-16 BFSC M3X25 Testing / Checking 50 0135800000 VL 2 SAK35 50 0124000000 50 0285100000 VH 24.5/8/5 SAK35 50 0298700000 100 0292500000 BFSC M4X35 50 0298900000 20 0299600000 50 0140200000 Width Test plug Socket PS 4 F.STB 4 7.6 mm STB 14/D6/4/M3 SAK10 Width 20 0299600000 PS 4 F.STB 4 50 0169900000 STB 16/D7/4/M4 SAK35 7.6 mm End plate / Partition plate beige Blue AP SAK16 1.5 mm 20 0271160000 AP SAK35/TW SAK16 1.5 mm 10 0303660000 AP SAK16 BL 1.5 mm 20 0271180000 AP SAK35/TW SAK16 BL 1.5 mm 10 0303680000 TW SAK35 1.5 mm 20 0304360000 50 0178700000 100 0129100000 beige Blue Small partition Small partition TSCH 1 2 mm 100 0319160000 50 0518200000 AD 4 SAK35 100 0128900000 BFSC M4X32 PA/RT Cover / warning label Cover / warning label Mounting screw (plastic) Marking systems BFSC M3X22 PA/RT (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.4 AD 4 SAK16 DEK 5/5 DEK 5/5 / SCHT 7 If QIs are aligned side by side, then a TW/AP must be used. SAK 35/35/IK 35 mm² SAK 35N/35 35 mm² Hexagon socket head screw SAK 35N/35/IK 35 mm² Hexagon socket head screw SAK-Series TS 35 Feed-through modular terminals A 18 x 58 x 60 150 / 50 2.5...50 16 x 58 x 60 150 / 50 2.5...50 IEC 60947-7-1 Ex e II IEC 1000 125 35 T II 2 G D UL CSA EN 60079-7 600 600 550 105 145 109 AWG 12...2 AWG 12...2 35 8/3 B8 / V2 KEMA 97ATEX1798 U ru# Rated connection 2.5...16 / 4...50 2.5...35 / 2.5...35 4.0...6.0 Nm (M 6) 18 / S4 (DIN 6911) 16 x 58 x 60 150 / 50 2.5...50 IEC 60947-7-1 IEC 1000 125 35 IEC 60947-7-1 UL CSA 600 600 105 120 AWG 12...2 AWG 12...2 8/3 B8 / V2 IEC 1000 125 35 ru#a UL CSA 600 600 105 120 AWG 12...2 AWG 12...2 8/3 B8 / V2 ?ru#a Rated connection 2.5...16 / 4...50 2.5...35 / 1.5...35 4.0...5.0 Nm (M 6) 18 / 6.5 x 1.2 mm Rated connection 2.5...16 / 4...50 2.5...35 / 1.5...35 4.0...6.0 Nm (M 6) 18 / S4 (DIN 6911) 2.5...10 / 10...16 2.5...16 / 2.5...16 2.5...10 / 10...16 2.5...16 / 2.5...16 2.5...10 / 10...16 2.5...16 / 2.5...16 The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stranded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used. The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stranded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used. The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stranded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used. Type Order No. Type Order No. Type 0582460000 SAK 35N/35 0608260000 SAK 35N/35/IK Qty. SAK 35/35/IK 20 Qty. 20 Qty. 20 Order No. 0608360000 It is possible to use twin ferrules with identical rated voltages (LAB 13090). It is possible to use twin ferrules with identical rated voltages (LAB 13090). It is possible to use twin ferrules with identical rated voltages (LAB 13090). Type current Qty. Order No. Type current Qty. Order No. Type current Qty. QL 2 SAK35 99 A 20 0123600000 QL 2 SAK35N 110 A 50 0564900000 QL 2 SAK35N 99 A 50 0564900000 QL 3 SAK35 99 A 20 0123700000 QL 3 SAK35N 110 A 50 0565000000 QL 3 SAK35N 99 A 50 0565000000 QL 4 SAK35 99 A 20 0123800000 QL 4 SAK35N 110 A 50 0565100000 QL 4 SAK35N 99 A 50 0565100000 QL 10 SAK35 99 A 20 0338600000 QL 10 SAK35N 110 A 20 0565200000 QL 10 SAK35N 99 A 20 0565200000 VH 17/8/5 SAK35 50 0267000000 VH 17/8/5 SAK35 50 0267000000 VH 17/8/5 SAK35 50 0267000000 BFSC M4X30 50 0267100000 BFSC M4X30 50 0267100000 BFSC M4X30 50 0267100000 100 0136400000 SS M4 100 0136400000 SS M4 100 0136400000 20 0299600000 PS 4 F.STB 4 20 0299600000 50 0140200000 STB 16/D7/4/M4 SAK35 50 0140200000 SS M4 D 128-A 4 D 128-A 4 50 0124000000 VH 24.5/8/5 SAK35 50 0298700000 BFSC M4X35 50 0298900000 20 0299600000 PS 4 F.STB 4 50 0140200000 STB 16/D7/4/M4 SAK35 VL 2 SAK35 119 A Width PS 4 F.STB 4 7.6 mm STB 16/D7/4/M4 SAK35 D 128-A 4 Width 7.6 mm Order No. Width 7.6 mm AP SAK35/TW SAK16 1.5 mm 10 0303660000 AP SAK35/TW SAK16 1.5 mm 10 0303660000 AP SAK35/TW SAK16 1.5 mm 10 0303660000 AP SAK35/TW SAK16 BL 1.5 mm 10 0303680000 AP SAK35/TW SAK16 BL 1.5 mm 10 0303680000 AP SAK35/TW SAK16 BL 1.5 mm 10 0303680000 TW SAK35 1.5 mm 20 0304360000 TW SAK35 1.5 mm 20 0304360000 TW SAK35 1.5 mm 20 0304360000 50 0178700000 AD 4 SAK35N 50 0576700000 AD 4 SAK35N 50 0576700000 100 0129100000 BFSC M4X32 PA/RT 100 0129100000 BFSC M4X32 PA/RT 100 0129100000 AD 4 SAK35 BFSC M4X32 PA/RT DEK 5/5 DEK 5/5 DEK 5/5 If QIs are aligned side by side, then a TW/AP must be used. If QIs are aligned side by side, then a TW/AP must be used. If QIs are aligned side by side, then a TW/AP must be used. A.5 SAK-Series TS 35 Feed-through modular terminals A SAK 70/35 TS 35 / PA 70 mm² In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data 22 x 75 x 87 192 / 70 16...70 IEC 60947-7-1 Rated data Rated voltage V Rated current A Rated cross-section mm² Rated impulse voltage / Pollution severity kV/Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded mm² flexible / Stranded wire with end ferrules mm² Tightening torque range (clamping screw) Stripping length / Blade size mm/2 conductors with same cross-section (H05V/H07V) solid / stranded mm² flexible / Stranded wire with end ferrules mm² Note IEC 1000 192 70 UL CSA 600 600 150 150 AWG 4...2/0 AWG 4...2/0 8/3 B11 / V2 ru#a Rated connection 16...16 / 16...70 16...70 / 16...35 6.0...12 Nm (M 8) 24 / S6 (DIN 6911) Tightening torque for 70 mm² stranded = 12 Nm. Ordering data Version Type beige Qty. SAK 70/35 Order No. 0139160000 10 Blue Note Accessories Screwable cross-connection current Qty. 2-pole Type QL 2 SAK70 192 A 20 0345300000 Order No. 3-pole QL 3 SAK70 192 A 5 0167000000 VH 30.5/11/5.5 SAK70 20 0345500000 BFSC M5X45 20 0345600000 SS M5 50 0346100000 20 0299600000 50 0385400000 10 0340960000 AD 3 SAK70 10 0344300000 BFSC M5X45 PA/NA 50 0344400000 4-pole 10-pole Connecting sleeve Mounting screw Lock washer D 128-A 5 Switchable link Switchable link Connecting sleeve Mounting screw Testing / Checking Width Test plug Socket PS 4 F.STB 4 7.6 mm STB 16/D7/4/M5 SAK70 End plate / Partition plate beige AP SAK70/35 2 mm Blue beige Blue Small partition Small partition Cover / warning label Cover / warning label Mounting screw (plastic) Marking systems (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.6 DEK 5/5 SAK 2.5 TS 35 / KrG 2.5 mm² SAK 4 4 mm² A In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data 6.1 x 49.5 x 40 32 / 6 0.13...6 6.5 x 45 x 44 41 / 6 0.13...6 IEC 60947-7-1 Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size V A mm² kV/- mm² mm² mm/- Note Ex e II IEC 800 24 2.5 T II 2 G D UL CSA EN 60079-7 600 600 550 20 25 21 AWG 22...12 AWG 26...10 2.5 8/3 A3 / 5VA KEMA 97ATEX1798 U ru#i~a Rated connection 0.5...6 / 0.5...4 0.5...4 / 0.5...2.5 0.4...0.6 Nm (M 2.5) 10 / 0.6 x 3.5 mm IEC 60947-7-1 Ex e II IEC 800 32 4 T II 2 G D UL CSA EN 60079-7 600 600 550 30 36 28 AWG 22...12 AWG 26...10 4 8/3 A4 / 5VA KEMA 97ATEX1798 U ?r#ia Rated connection 0.5...6 / 0.5...4 0.5...4 / 0.5...4 0.5...1.0 Nm (M 3) 12 / 0.6 x 3.5 mm With twin ferrules ZH 0.5 to ZH 1.5, rated voltage is 690 V. With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V. Type Qty. Order No. Type Qty. Order No. SAK 2.5/35 KRG 100 0380420000 SAK 4/35 KRG 100 0443620000 SAK 2.5/35 KRG/BL 100 0380470000 SAK 4/35 KRG/BL 100 0443670000 Ordering data Version Medium yellow Blue Note Accessories Screwable cross-connection current Qty. Order No. Type current Qty. 2-pole Type Q 2 SAK2.5 41 A 50 0337000000 Q 2 SAK4 41 A 50 0336700000 3-pole Q 3 SAK2.5 41 A 50 0337100000 Q 3 SAK4 41 A 50 0336800000 4-pole Q 4 SAK2.5 41 A 50 0337200000 Q 4 SAK4 41 A 50 0336900000 10-pole Q 10 SAK2.5 41 A 20 0368700000 Q 10 SAK4 41 A 20 Order No. 0368800000 VL 2 SAK4 32 A 50 0197000000 50 0285100000 100 0292500000 20 0180400000 50 0168600000 Connecting sleeve Mounting screw Lock washer Switchable link Switchable link VH 19/5/3.5 SAK4-16 Connecting sleeve Mounting screw BFSC M3X25 Testing / Checking Width Test plug Socket PS 2.3 RT 5.4 mm STB 8.5/5/2.3/M3 SAK2.5 Width 20 0180400000 PS 2.3 RT 50 0280600000 STB 14/D5/2.3/M3 SAK2.5 5.4 mm End plate / Partition plate Medium yellow Blue Medium yellow Blue AP SAK2.5 KRG 1.5 mm 20 0279520000 AP SAK4-10 KRG 1.5 mm 20 0117920000 AP SAK2.5 KRG BL 1.5 mm 20 0279570000 AP SAK4-10 KRG/BL 1.5 mm 20 0117970000 TW SAK2.5 KRG 2.5 mm 20 0302820000 TW SAK4-10 KRG 2.5 mm 20 0130120000 TW SAK2.5 KRG/BL 2.5 mm 20 0302870000 TW SAK4-10 KRG/BL 2.5 mm 20 0130170000 2 mm 100 0319160000 TSCH 1 2 mm 100 0319160000 50 0303400000 AD 4 SAK4 50 0285300000 100 0128900000 BFSC M3X22 PA/RT 100 0128900000 Small partition Small partition TSCH 1 Cover / warning label Cover / warning label Mounting screw (plastic) Marking systems AD 4 AKZ4 BFSC M3X22 PA/RT (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section SAK-Series TS 35 Feed-through modular terminals DEK 5/6 / SCHT 7 DEK 5/6,5 / SCHT 7 A.7 SAK-Series TS 35 Feed-through modular terminals A SAK 6 TS 35 / KrG 6 mm² SAK 10 10 mm² In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data 8 x 45 x 44 57 / 10 0.33...10 10 x 45 x 51.5 76 / 16 1.5...16 IEC 60947-7-1 Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size V A mm² kV/- mm² mm² mm/- Note Ex e II IEC 800 41 6 T II 2 G D UL CSA EN 60079-7 600 600 550 40 47 36 AWG 22...8 AWG 20...8 6 8/3 A5 / 5VA KEMA 97ATEX1798 U ru#i~a Rated connection 0.5...10 / 0.5...6 0.5...10 / 0.5...6 0.8...1.6 Nm (M 3.5) 12 / 4.0 x 0.8 mm IEC 60947-7-1 Ex e II IEC 800 57 10 T II 2 G D UL CSA EN 60079-7 600 600 550 60 65 50 AWG 14...6 AWG 16...6 10 8/3 B6 / 5VA KEMA 97ATEX1798 U ru#i~a Rated connection 1.5...10 / 1.5...16 1.5...16 / 1.5...10 2.0...4.0 Nm (M 4) 12 / 1.0 x 5.5 mm For AWG 8-7 and AWG 8-19, tightening torque is 1.21.4 Nm When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V. Type Qty. Order No. Type Qty. Order No. SAK 6/35 KRG 100 0380520000 SAK 10/35 KRG 100 0443720000 SAK 6/35 KRG/BL 100 0380570000 SAK 10/35 KRG/BL 100 0443770000 Ordering data Version Medium yellow Blue Note With AWG 6 and H07V-R10 conductors, an increased MD torque of 1.4 to1.6 Nm should be used. A higher torque of 2 to 2.4 Nm is necessary when using H07V-R16 and AWG 6 conductors. Type Accessories Screwable cross-connection current Qty. Order No. Type current Qty. 2-pole Q 2 SAK6N 57 A 50 0456700000 Q 2 SAK10 57 A 50 0457100000 Order No. 3-pole Q 3 SAK6N 57 A 50 0456800000 Q 3 SAK10 57 A 50 0457200000 4-pole Q 4 SAK6N 57 A 50 0456900000 Q 4 SAK10 57 A 50 0457300000 10-pole Q 10 SAK6N 57 A 20 0457000000 Q 10 SAK10 57 A 20 0457400000 VL 2 SAK6N/SAKT 50 0194700000 VL 2 SAK6/10/SAKB 32 A 50 0135900000 VH 19/5/3.5 SAK4-16 50 0285100000 VH 19/5/3.5 SAK4-16 50 0285100000 100 0292500000 BFSC M3X25 100 0292500000 20 0299600000 50 0169900000 Connecting sleeve Mounting screw Lock washer Switchable link Switchable link Connecting sleeve Mounting screw BFSC M3X25 Testing / Checking Width Test plug Socket PS 4 F.STB 4 7.6 mm STB 14/D6/4/M3 SAK10 Width 20 0299600000 PS 4 F.STB 4 50 0169900000 STB 14/D6/4/M3 SAK10 7.6 mm End plate / Partition plate Medium yellow Blue Medium yellow Blue AP SAK4-10 KRG 1.5 mm 20 0117920000 AP SAK4-10 KRG 1.5 mm 20 0117920000 AP SAK4-10 KRG/BL 1.5 mm 20 0117970000 AP SAK4-10 KRG/BL 1.5 mm 20 0117970000 TW SAK4-10 KRG 2.5 mm 20 0130120000 TW SAK4-10 KRG 2.5 mm 20 0130120000 TW SAK4-10 KRG/BL 2.5 mm 20 0130170000 TW SAK4-10 KRG/BL 2.5 mm 20 0130170000 2 mm 100 0319160000 TSCH 1 2 mm 100 0319160000 50 0196600000 AD 4 SAK10 50 0178600000 100 0128900000 BFSC M3X22 PA/RT 100 0128900000 Small partition Small partition TSCH 1 Cover / warning label Cover / warning label Mounting screw (plastic) Marking systems BFSC M3X22 PA/RT (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.8 AD 4 SAK6N DEK 5/8 / SCHT 7 When used with twin ferrules ZH 0.5 - ZH 4, the rated voltage is 690 V. DEK 5/5 SAK 16 16 mm² SAK 35N/35 35 mm² SAK 35N/35/IK 35 mm² Hexagon socket head screw SAK-Series TS 35 Feed-through modular terminals A 12 x 50 x 57.5 76 / 16 2.5...16 16 x 58 x 60 125 / 50 2.5...50 IEC 60947-7-1 Ex e II IEC 1000 76 16 T II 2 G D UL CSA EN 60079-7 600 600 690 80 87 66 AWG 12...4 AWG 14...6 16 8/3 B6 / 5VA KEMA 97ATEX1798 U ru#ia Rated connection 2.5...16 / 4...16 4...16 / 4...16 2.0...4.0 Nm (M 4) 15 / 1.0 x 5.5 mm Twin wire end ferrules ZH 2.5 - ZH 16 can be used. Type Qty. SAK 16/35 KRG 50 16 x 58 x 60 125 / 50 2.5...50 IEC 60947-7-1 IEC 1000 125 35 IEC 60947-7-1 UL CSA 600 600 105 120 AWG 12...2 AWG 12...2 8/3 B8 / 5VA IEC 1000 125 35 ru#a UL CSA 600 600 105 120 AWG 12...2 AWG 12...2 8/3 B8 / 5VA ru#a Rated connection 2.5...16 / 4...50 2.5...35 / 1.5...35 4.0...5.0 Nm (M 6) 18 / 6.5 x 1.2 mm Rated connection 2.5...16 / 4...50 2.5...35 / 1.5...35 4.0...6.0 Nm (M 6) 18 / S4 (DIN 6911) The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stranded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used. The tightening torque is 4.5 Nm for 16 - 50 mm² and AWG 6 - 2/7 stranded conductors. Twin wire end ferrules ZH 2.5 - ZH 16 can be used. Order No. Type Order No. Type 0380620000 SAK 35N/35 KRG 0608220000 SAK 35N/35/IK KRG 20 0608320000 SAK 35N/35/IK KRG/BL 20 0608370000 Qty. 20 Qty. Order No. If QIs are aligned side by side, then a TW/AP must be used. It is possible to use twin ferrules with identical rated voltages (LAB 13090). It is possible to use twin ferrules with identical rated voltages (LAB 13090). Type current Qty. Order No. Type current Qty. Order No. Type current Qty. Q 2 SAK16 76 A 50 0457500000 QL 2 SAK35N 110 A 50 0564900000 QL 2 SAK35N 99 A 50 0564900000 Q 3 SAK16 76 A 50 0457600000 QL 3 SAK35N 110 A 50 0565000000 QL 3 SAK35N 99 A 50 0565000000 Q 4 SAK16 76 A 50 0457700000 QL 4 SAK35N 110 A 50 0565100000 QL 4 SAK35N 99 A 50 0565100000 Q 10 SAK16 76 A 20 0457800000 QL 10 SAK35N 110 A 20 0565200000 QL 10 SAK35N 99 A 20 0565200000 VH 17/8/5 SAK35 50 0267000000 VH 17/8/5 SAK35 50 0267000000 BFSC M4X30 50 0267100000 BFSC M4X30 50 0267100000 100 0136400000 SS M4 100 0136400000 20 0299600000 PS 4 F.STB 4 20 0299600000 50 0140200000 STB 16/D7/4/M4 SAK35 50 0140200000 SS M4 VL 2 SAK16/SAKA 57 A VH 19/5/3.5 SAK4-16 BFSC M3X25 D 128-A 4 50 0135800000 50 0285100000 100 0292500000 20 0299600000 PS 4 F.STB 4 50 0169900000 STB 16/D7/4/M4 SAK35 20 0271120000 AP SAK35 KRG 3 mm 10 0303620000 AP SAK35 KRG 3 mm 10 0303620000 AP SAK35 KRG/BL 3 mm 10 0303670000 AP SAK35 KRG/BL 3 mm 10 0303670000 TW SAK35 KRG 3 mm 20 0304320000 TW SAK35 KRG 3 mm 20 0304320000 50 0178700000 AD 4 SAK35N 50 0576700000 100 0128900000 BFSC M4X32 PA/RT 100 0129100000 Width PS 4 F.STB 4 7.6 mm STB 14/D6/4/M3 SAK10 AP SAK16 KRG 3 mm Width TW SAK16 KRG 3 mm 20 0281120000 TSCH 1 2 mm 100 0319160000 50 0518200000 AD 4 SAK35 100 0128900000 BFSC M3X22 PA/RT AD 4 SAK16 BFSC M3X22 PA/RT DEK 5/5 D 128-A 4 Order No. 7.6 mm Width 7.6 mm DEK 5/5 DEK 5/5 If QIs are aligned side by side, then a TW/AP must be used. If QIs are aligned side by side, then a TW/AP must be used. A.9 SAK-Series TS 35 Feed-through modular terminals A SAK 95/35 TS 35 / KrG 95 mm² In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data 28 x 87.9 x 96.5 269 / 120 16...120 IEC 60947-7-1 Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size V A mm² kV/- IEC 1000 232 95 UL CSA 600 600 190 200 AWG 6...4/0 AWG 6...4/0 8/3 B12 / 5VA r#a mm² mm² mm/- Note Rated connection 16...16 / 10...120 16...95 / 10...95 16...20 Nm (M 10) 30 / S8 (DIN 6911) Ribbon cable (segmented ribbon) can be connected ranging from 3 to 6 segments of 0.8x9 mm, up to 6 segments of 0.8x16 mm and up to 6 segments of 0.5x13 mm. Ordering data Version Type Medium yellow Qty. SAK 95/35 KRG Order No. 0662220000 10 Blue Note Accessories Screwable cross-connection current Qty. 2-pole Type QL 2 SAKG28 125 A 10 0551200000 Order No. 3-pole QL 3 SAKG28 232 A 5 0407600000 4-pole QL 4 SAKG28 125 A 5 0407700000 VH 35/11/5.5 SAK95 10 0551100000 KISC M5X50/26 SAK95 20 0630200000 SS M5 50 0346100000 20 0299600000 50 0385400000 10-pole Connecting sleeve Mounting screw Lock washer D 128-A 5 Switchable link Switchable link Connecting sleeve Mounting screw Testing / Checking Width Test plug Socket PS 4 F.STB 4 7.6 mm STB 16/D7/4/M5 SAK70 End plate / Partition plate Medium yellow Blue AP SAK95 KRG 3 mm 10 0550920000 AP SAK95 KRG/BL 3 mm 10 0550970000 ADP 3/HP3 1M 20 0485400000 BFSC M5X45 PA/NA 50 0344400000 Medium yellow Blue Small partition Small partition Cover / warning label Cover / warning label Mounting screw (plastic) Marking systems (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.10 DEK 5/5 / SCHT 7 Holder HP 3 0485760000 for the ADP 3-Profil. RSF 3/35 TS 35 / PA SAK-Series TS 35 Terminals with spring-loaded cable clamps 4 mm² A In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data 8 x 50 x 60 32 / 4 0.33...4 IEC 60947-7-1 Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size IEC 690 32 4 V A mm² kV/- UL CSA 600 600 20 25 AWG 22...12 AWG 22...12 6/3 / V2 # mm² mm² mm/- Rated connection 0.5...4 / 0.5...4 0.5...4 / 0.5...4 0.5...1.0 Nm (M 3) 12 / 0.6 x 3.5 mm Note Ordering data Version Type beige Qty. RSF 3/35 50 Order No. 9501160000 Note Accessories Screwable cross-connection current Qty. 2-pole Type QL 2 SAK6N 57 A 50 0194300000 Order No. 3-pole QL 3 SAK6N 57 A 50 0194400000 4-pole QL 4 SAK6N 57 A 50 0194500000 10-pole QL 10 SAK6N 57 A 20 0338300000 Connecting sleeve VH 13.5/4.9/3.3 SAK4 100 0248500000 Mounting screw KISC M3X20.5/10 EK4 100 0303000000 50 0164400000 VL 2 SAK6N/SAKT 50 0194700000 VH 21/5/3.5 SAK16-35 50 0309600000 BFSC M3X30 50 0296200000 20 0180400000 50 0168600000 Lock washer SS M3 D 128-A 3 Switchable link Switchable link Connecting sleeve Mounting screw Testing / Checking Width Test plug Socket PS 2.3 RT 5.4 mm STB 14/D5/2.3/M3 SAK2.5 End plate / Partition plate beige AP RSF3 3 mm 10 0270460000 beige TW AST1/PA HP/DBR/0.5 0.5 mm 20 0474700000 100 0319160000 36 0485300000 Small partition Small partition TSCH 1 2 mm Cover / warning label Cover / warning label Marking systems ADP 2/HP2 1M (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section DEK 5/5 A.11 SAK-Series TS 35 Two-tier modular terminals A DK 4/35 TS 35 / PA 4 mm² DK 4 Q/35 4 mm² In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data Rated data Rated voltage V Rated current A Rated cross-section mm² Rated impulse voltage / Pollution severity kV/Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded mm² flexible / Stranded wire with end ferrules mm² Tightening torque range (clamping screw) Stripping length / Blade size mm/2 conductors with same cross-section (H05V/H07V) solid / stranded mm² flexible / Stranded wire with end ferrules mm² Note 6 x 50 x 60.5 41 / 6 0.13...6 6 x 50 x 60.5 41 / 6 0.13...6 IEC 60947-7-1 IEC 60947-7-1 IEC 500 32 4 UL CSA 300 300 27 10 AWG 22...12 AWG 26...12 6/3 A3 / V2 IEC 500 32 4 rua UL CSA 300 300 27 10 AWG 22...12 AWG 26...12 6/3 A3 / V2 ?ru~a Rated connection 0.5...6 / 0.5...4 0.5...4 / 0.5...2.5 0.5...0.8 Nm (M 3) 8 / 0.6 x 3.5 mm Rated connection 0.5...6 / 0.5...4 0.5...4 / 0.5...2.5 0.5...0.8 Nm (M 3) 8 / 0.6 x 3.5 mm 0.5...1.5 0.5...1.5 / 0.5...1.5 0.5...1.5 0.5...1.5 / 0.5...1.5 With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V. With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V. Type Qty. Order No. Type Qty. Order No. DK 4/35 100 0527660000 DK 4Q/35 100 0590160000 DK 4/35 BL 100 0527680000 DK 4Q/35 BL 100 0590180000 Ordering data Version beige Blue Note Accessories Screwable cross-connection current Qty. Order No. Type current Qty. 2-pole Type Q 2 AKZ4 32 A 50 0336400000 Q 2 AKZ4 32 A 50 0336400000 3-pole Q 3 AKZ4 32 A 50 0336500000 Q 3 AKZ4 32 A 50 0336500000 4-pole Q 4 AKZ4 32 A 50 0336600000 Q 4 AKZ4 32 A 50 0336600000 10-pole Q 10 AKZ4 32 A 20 0368600000 Q 10 AKZ4 32 A 20 0368600000 20 0180400000 50 0215700000 Testing / Checking Width Test plug Socket PS 2.3 RT 5.4 mm STB 8.5/D4/2.3/M2.5 AKZ Order No. Width 20 0180400000 PS 2.3 RT 50 0215700000 STB 8.5/D4/2.3/M2.5 AKZ 5.4 mm End plate / Partition plate beige Blue Dark beige Wemid AP DK4 1.5 mm 20 0359260000 AP DK4Q 1.5 mm 20 1397160000 AP DK4 BL 1.5 mm 20 0359280000 AP DK4Q BL 1.5 mm 20 1397180000 WTW EN 3 mm 20 1058800000 WTW EN 3 mm 20 1058800000 TSCH 6 DKI S4 5 mm 100 0190260000 TSCH 6 DKI S4 5 mm 100 0190260000 50 0297900000 AD 3 SAK2.5 50 0297900000 100 0303300000 BFSC M2.5X18 PA/RT 100 0303300000 Small partition Small partition Cover / warning label Cover / warning label Mounting screw (plastic) Marking systems BFSC M2.5X18 PA/RT (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.12 AD 3 SAK2.5 DEK 5/6 DEK 5/6 DK 4 QV/35 SAK-Series TS 35 Two-tier modular terminals 4 mm² A 6 x 54 x 40.5 41 / 6 0.13...6 IEC 60947-7-1 IEC 500 32 4 UL CSA 300 300 27 10 AWG 22...12 AWG 26...12 6/3 A3 / V2 ?ru~a Rated connection 0.5...6 / 0.5...4 0.5...4 / 0.5...2.5 0.5...0.8 Nm (M 3) 8 / 0.6 x 3.5 mm 0.5...1.5 0.5...1.5 / 0.5...1.5 With twin ferrules ZH 0.5 to ZH 2.5, rated voltage is 690 V. Type Qty. Order No. DK 4QV/35 100 0363660000 DK 4QV/35 BL 100 0363680000 Type current Qty. Q 2 AKZ4 32 A 50 0336400000 Order No. Q 3 AKZ4 32 A 50 0336500000 Q 4 AKZ4 32 A 50 0336600000 Q 10 AKZ4 32 A 20 0368600000 20 0180400000 50 0215700000 Width PS 2.3 RT 5.4 mm STB 8.5/D4/2.3/M2.5 AKZ AP DK4Q 1.5 mm 20 1397160000 AP DK4Q BL 1.5 mm 20 1397180000 WTW EN 3 mm 20 1058800000 TSCH 6 DKI S4 5 mm 100 0190260000 50 0303400000 100 0303300000 AD 4 AKZ4 BFSC M2.5X18 PA/RT DEK 5/6 A.13 SAK-Series TS 35 Modular PE terminals A EK 2.5/35 TS 35 / PA 2.5 mm² EK 4/35 4 mm² In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data 6 x 56.5 x 40 /6 0.33...6 PE IEC 60947-7-2 Rated data Rated cross-section Rated voltage to adjacent terminal Rated impulse withstand voltage to adjacent terminal Short-time withstand current Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Tightening torque range (fixing screw) Stripping length / Blade size mm² V kV IEC 2.5 800 8 6.5 x 56.5 x 44 /6 0.33...6 IEC 60947-7-2 UL AWG 22...12 CSA AWG 26...10 IEC 4 800 8 UL AWG 22...12 480 A (4 mm²) 3 A3 / V2 mm/- CSA AWG 26...10 720 A (6 mm²) 3 A4 / V2 r#ia mm² mm² PE r#ia Rated connection 0.5...6 / 0.5...4 0.5...4 / 0.5...2.5 0.4...0.6 Nm (M 2.5) 0.4...0.6 Nm 10 / 0.6 x 3.5 mm Rated connection 0.5...6 / 0.5...4 0.5...4 / 0.5...4 0.5...1.0 Nm (M 3) 0.5...1.0 Nm 12 / 0.6 x 3.5 mm Note Ordering data Version green/yellow Type Qty. Order No. Type Qty. Order No. EK 2.5/35 100 0661060000 EK 4/35 100 0661160000 Order No. Type Width Qty. 0494920000 SH 2 40 mm 10 Note Accessories Rail support Marking systems Width Qty. SH 2 40 mm 10 (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.14 Type DEK 5/6 DEK 5/6,5 Order No. 0494920000 EK 6/35 6 mm² EK 10 10 mm² EK 16 16 mm² SAK-Series TS 35 Modular PE terminals A 8 x 56.5 x 44 / 10 0.5...10 PE IEC 60947-7-2 IEC 6 800 8 10 x 56 x 45 / 10 0.5...10 PE IEC 60947-7-2 UL AWG 22...8 CSA AWG 20...8 IEC 10 800 8 12 x 56 x 50 / 16 2.5...16 PE IEC 60947-7-2 UL AWG 14...6 720 A (6 mm²) 3 A5 / V2 CSA AWG 14...6 IEC 16 800 8 UL AWG 10...6 1200 A (10 mm²) 3 B6 / V2 r#a 1920 A (16 mm²) 3 B6 / V2 r#a Rated connection 0.5...10 / 1.5...6 0.5...10 / 0.5...6 0.8...1.6 Nm (M 3.5) 0.5...1.0 Nm 12 / 4.0 x 0.8 mm CSA AWG 10...4 r#a Rated connection 0.5...10 / 1.5...6 0.5...10 / 0.5...10 1.2...2.4 Nm (M 4) 0.5...1.0 Nm 12 / 1.0 x 5.5 mm Rated connection 2.5...16 / 2.5...16 2.5...16 / 4...16 2.0...4.0 Nm (M 4) 0.5...1.0 Nm 16 / 1.0 x 5.5 mm For AWG 8-7 and AWG 8-19, tightening torque is 1.21.4 Nm Type Qty. Order No. Type Qty. Order No. Type EK 6/35 100 0661260000 EK 10/35 100 0661360000 EK 16/35 Order No. Type Width Qty. Order No. Type Width Qty. 0494920000 SH 2 40 mm 10 0494920000 SH 2 40 mm 10 Type Width Qty. SH 2 40 mm 10 DEK 5/8 DEK 5/5 Qty. 50 Order No. 0190160000 Order No. 0494920000 DEK 5/5 A.15 SAK-Series TS 35 Modular PE terminals A EK 35/35 TS 35 / PA 35 mm² EK 95/35 95 mm² In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data 16 x 58 x 60 / 50 6...50 PE IEC 60947-7-2 Rated data Rated cross-section Rated voltage to adjacent terminal Rated impulse withstand voltage to adjacent terminal Short-time withstand current Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Tightening torque range (fixing screw) Stripping length / Blade size mm² V kV IEC 35 800 8 25 x 76.5 x 90.5 / 120 10...120 IEC 60947-7-2 UL AWG 6...2 CSA AWG 12...2 IEC 95 mm/- CSA 11400 A (95 mm²) 3 B12 / --- r#a Note UL 8 4200 A (35 mm²) 3 B9 / V2 mm² mm² PE Rated connection 6...16 / 16...50 10...35 / 10...35 4.0...6.0 Nm (M 6) 1.2...2.4 Nm 20 / 6.5 x 1.2 mm Rated connection 10...16 / 10...95 16...95 / 10...95 10...20 Nm (M 10) 1.2...2.4 Nm 27 / Use the TS 35x15/2.3 for 35 - 50 mm² conductors. For AWG 2/7 and H07V-R50, torque is 6 Nm. Tightening torque for stranded conductors of 35 mm² and larger = 16 Nm Type Ordering data Version green/yellow Qty. EK 35/35 20 Order No. Type 0661460000 EK 95/35/1ZB BK Qty. Order No. Type Width Qty. 0494920000 SH 2 40 mm 10 10 Order No. 0535300000 Note Accessories Rail support Marking systems Width Qty. SH 2 40 mm 10 Order No. 0494920000 (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.16 Type DEK 5/5 To fix the terminals use the copper rail TS35 order no. 0270100000. SAKE 70/35 SAK-Series TS 35 Modular PE terminals 70 mm² A 18 x 94 x 59.5 / 70 10...70 PE IEC 60947-7-2 IEC 70 UL CSA B10 / --- # Rated connection 10...16 / 10...70 10...70 / 10...70 6.0...12 Nm (M 8) 2.0...4.0 Nm 25 / When connecting with stranded conductors ≥ 50 mm² and 12 Nm tightening torque. Test current 8.4 kA to IK carried out via copper terminal rail Type Qty. EK 70/35/M.2ZB O.IK 10 Type Width Qty. SH 2 40 mm 10 Order No. 1338300000 Order No. 0494920000 Use the steel TS 35x15/2.3 for 35 - 50 mm² conductors. Use the TS 35x15/2.3 CU for 70 mm² conductors. A.17 SAK-Series TS 35 Disconnect terminals A SAKR TS 35 / PA 4 mm² SAKR-D 4 mm² In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size 6.5 x 42 x 40.5 10 / 4 0.13...4 6.5 x 46 x 38 10 / 4 0.13...4 IEC 60947-7-1 IEC 60947-7-1 IEC 400 10 4 V A mm² kV/- UL CSA 300 300 10 10 AWG 22...12 AWG 22...12 6/3 A3 / V2 IEC 250 10 4 # mm² mm² mm/- Note UL CSA 300 300 10 10 AWG 26...12 AWG 22...12 6/3 A3 / V2 r# Rated connection 0.5...4 / 1.5...4 0.5...4 / 0.5...2.5 0.5...1.0 Nm (M 3) 8 / 0.6 x 3.5 mm Rated connection 0.5...4 / 1.5...4 0.5...4 / 0.5...2.5 0.5...1.0 Nm (M 3) 8 / 0.6 x 3.5 mm Torque for SAKR with socket: 0.5 - 0.7 Nm. Tightening torque via the sockets is 0.5 - 0.7 Nm. Ordering data Version beige Blue Note Type Qty. Order No. Type SAKR/35 100 0172160000 SAKRD/35 SAKR/35 BL 100 0172180000 Qty. 50 Order No. 0185760000 SAKR/35 2 StB order no. 0183360000 Accessories External cross-connection current Qty. Order No. Type current Qty. 2-pole Type QB 2 WI RA6 IS 27 A 50 0482700000 QB 2 WI RA6 IS 27 A 50 0482700000 3-pole QB 3 WI RA6 IS 27 A 50 0482800000 QB 3 WI RA6 IS 27 A 50 0482800000 4-pole QB 4 WI RA6 IS 27 A 50 0482900000 QB 4 WI RA6 IS 27 A 50 0482900000 Testing / Checking Width Test plug Socket PS 2.3 RT 5.4 mm STB 6/D3.7/2.3/M3 SAKR Order No. Width 20 0180400000 PS 2.3 RT 100 0379400000 STB 6/D3.7/2.3/M3 SAKR 5.4 mm 20 0180400000 100 0379400000 End plate / Partition plate Marking systems beige AP SAKR BE 1.5 mm 20 0211360000 AP SAKR BE 1.5 mm 20 0211360000 Blue AP SAKR BL 1.5 mm 20 0211380000 AP SAKR BL 1.5 mm 20 0211380000 (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.18 DEK 5/6,5 DEK 5/6,5 QB 25 blank, refer to „Accessories“ section. Note that max. conductor connection with QB = 2.5 mm². Twin wire-end ferrules ZH 0.5 - ZH 1.5 Twin wire-end ferrules ZH 0.5 - ZH 1.5 can be used. DKT 4 4 mm² DKT 4 V SAK-Series TS 35 Disconnect terminals 4 mm² Without separated busbar A 6 x 65 x 56.5 10 / 4 0.13...4 6 x 65 x 56.5 10 / 4 0.13...4 IEC 60947-7-1 IEC 400 10 4 IEC 60947-7-1 UL CSA IEC 400 10 4 6/3 A3 / V2 UL CSA 6/3 A3 / V2 r#a # Rated connection 0.2...4 / 1.5...4 0.2...4 / 0.5...2.5 0.5...1.0 Nm (M 3) 9 / 0.6 x 3.5 mm Rated connection 0.5...4 / 1.5...4 0.5...4 / 0.5...2.5 0.5...1.0 Nm (M 3) 9 / 0.6 x 3.5 mm Type Qty. Order No. Type Qty. Order No. DKT 4/35 100 0687460000 DKT 4V/35 2STB 100 1304960000 DKT 4/35 2 StB Order No. 0327960000 Type current Qty. Order No. Type current Qty. QB 2 WI RA6 IS 27 A 50 0482700000 QB 2 WI RA6 IS 27 A 50 0482700000 QB 3 WI RA6 IS 27 A 50 0482800000 QB 3 WI RA6 IS 27 A 50 0482800000 QB 4 WI RA6 IS 27 A 50 0482900000 QB 4 WI RA6 IS 27 A 50 0482900000 Width Order No. Width PS 2.3 RT 5.4 mm 20 0180400000 PS 2.3 RT 5.4 mm 20 0180400000 AP DKT4 PA 1.5 mm 20 0687560000 AP DKT4 PA 1.5 mm 20 0687560000 DEK 5/6 DEK 5/6 A.19 SAK-Series TS 35 Disconnect terminals A SAKC 4/35 TS 35 / KrG 4 mm² SAKC 10/35 10 mm² In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size 6.5 x 49.5 x 59.5 25 / 6 0.33...6 12 x 65 x 48.5 27 / 10 0.5...10 IEC 60947-7-1 IEC 60947-7-1 IEC 400 25 4 V A mm² kV/- UL CSA 300 300 25 25 AWG 22...12 AWG 22...10 6/3 A4 / 5VA IEC 500 27 10 r# mm² mm² mm/- Note UL CSA 300 600 25 25 AWG 22...8 AWG 20...10 6/3 B6 / 5VA r#a Rated connection 0.5...6 / 1.5...4 0.5...4 / 0.5...4 0.5...1.0 Nm (M 3) 12 / 0.6 x 3.5 mm Rated connection 0.5...10 / 1.5...10 0.5...10 / 0.5...10 1.2...2.4 Nm (M 4) 12 / 1.0 x 5.5 mm *UNDEFINED TEXT* Connections for stranded conductors from 10 mm² require a tightening torque of 2 Nm. Ordering data Version Medium yellow Note Type Qty. Order No. Type SAKC 4/35 100 0357520000 SAKC 10/35 1STB4 KRG SAKC 4/35 2 StB order no. 0340620000. Tightening torque via the sockets is 0.5 - 0.7 Nm. Qty. 50 Order No. 1404520000 SAKC 10/35 2 StB4 Order No. 1404620000 Tightening torque via the sockets is 1.2 Nm. Accessories Screwable cross-connection current Qty. 2-pole Type Qty. Order No. Type QL 2 SAKA10 47 A 50 0135500000 3-pole QL 3 SAKA10 47 A 50 0135600000 4-pole QL 4 SAKA10 47 A 50 0135700000 50 0299700000 BFSC M4X20 100 0362800000 SS M4 100 0136400000 20 0299600000 50 0147100000 3 mm 20 0146720000 1.5 mm 20 0242960000 3 mm 20 0242920000 VH 13.6/7/4.2 SAKA10 Connecting sleeve Mounting screw Lock washer D 128-A 4 Order No. current External cross-connection 2-pole QB 2 WI RA6 IS 27 A 50 0482700000 3-pole QB 3 WI RA6 IS 27 A 50 0482800000 4-pole QB 4 WI RA6 IS 27 A 50 0482900000 20 0180400000 Testing / Checking Width Test plug PS 2.3 RT 5.4 mm Width Socket PS 4 F.STB 4 7.6 mm STB 17/D6/4/M4 SAKC10 End plate / Partition plate Medium yellow Blue AP SAK4-10 KRG 1.5 mm 20 0117920000 AP SAK4-10 KRG/BL 1.5 mm 20 0117970000 TW SAK4-10 KRG 2.5 mm 20 0130120000 TW SAK4-10 KRG/BL 2.5 mm 20 0130170000 TW SAKB/C/T1 beige Medium yellow Blue Marking systems TW SAKB-C-T (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.20 AP SAKB/C/T KRG DEK 5/6,5 DEK 5/6,5 Dummy plug and pull out tool see chapter accessories Pull out force look under Accessories. A A.21 SAK-Series TS 35 SAK-Series TS 35 Fuse terminals A KSKM 1 TS 35 / PA 10 mm² 5 x 20 KSKM 2 10 mm² 1“ x 1/4“ In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² 13 x 69 x 63 6.3 / 16 0.13...16 13 x 69 x 63 13 / 16 0.13...16 Technical data Rated data Rated voltage V Rated current A Rated cross-section mm² Rated impulse voltage / Pollution severity kV/Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded mm² flexible / Stranded wire with end ferrules mm² Tightening torque range (clamping screw) Stripping length / Blade size mm/2 conductors with same cross-section (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules - IEC 250 6.3 10 UL 600 10 AWG 26...8 CSA IEC 250 13 10 UL 600 15 AWG 26...8 B6 / V-0 CSA B6 / V-0 #a #a Rated connection 0.5...16 0.5...10 1.2...2.4 Nm (M 4) 12 / 1.0 x 5.5 mm Rated connection 0.5...16 0.5...10 1.2...2.4 Nm (M 4) 12 / 1.0 x 5.5 mm Note Ordering data Version Type Qty. KSKM 1/35 G20 20 Type Qty. Order No. Type 9509600000 KSKM 2/35 GZ 1X1/4 Order No. Type Qty. Order No. 20 9509610000 Qty. Order No. Note Accessories G-fuse cartridge, 5 x 20mm (IEC 60127-2) 0,10 A G 20/0.10A/F 10 0430300000 0,20 A G 20/0.20A/F 10 0430400000 0,25 A fast G 20/0.25A/F 10 0430500000 0,50 A fast G 20/0.50A/F 10 0430600000 0,63 A G 20/0.63A/F 10 0439000000 1,00 A fast G 20/1.00A/F 10 0430700000 1,60 A G 20/1.60A/F 10 0430800000 2,00 A fast G 20/2.00A/F 10 0430900000 2,50 A G 20/2.50A/F 10 0431000000 3,15 A G 20/3.15A/F 10 0431100000 4,00 A G 20/4.00A/F 10 0431200000 5,00 A G 20/5.00A/F 10 0431300000 6,30 A G 20/6.30A/F 10 0431400000 10 0446100000 Width G25 with indicator / imperial (inch) fuse 1,00 A 0,50 A medium slow / 2 A 1,00 A medium slow / 3 A Contact sleeve SBL/1912 Marking systems (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.22 SBL/2111 DEK 5/5 DEK 5/5 Fuse 1“ x 1/4“ aren‘t available by Weidmüller. 10 0446200000 KSKM 3 10 mm² KDKS 1/35 SAK-Series TS 35 Fuse terminals 4 mm² 1 1/4“ x 1/4“ A 13 x 69 x 63.2 10 / 16 0.33...16 8 x 73.5 x 55.6 6.3 / 4 0.33...4 IEC 60947-7-3 IEC 440 10 10 UL 600 15 AWG 22...8 CSA IEC 500 6.3 4 B6 / V-0 #a UL CSA 300 10 AWG 22...12 6/3 A3 / V2 #a Rated connection 0.5...16 0.5...10 1.2...2.4 Nm (M 4) 12 / 1.0 x 5.5 mm Rated connection 0.5...4 / 1.5...4 0.5...4 / 0.5...4 0.5...0.8 Nm (M 3) 9 / 0.6 x 3.5 mm Note: max. conductor size = 2.5 mm² when using the cross-connection. Type Qty. KSKM 3/35 GZ 1 1/4X1/4 20 Order No. Type 9509620000 KDKS 1/35 Qty. 50 Order No. 9503310000 Max. power loss (1.6 W) at the cartridge fuse limits the rated current. Type Width Qty. Order No. GZ 1.0A/F 10 0525500000 GZ 2.0A 10 0294500000 GZ 3.0A 10 0295700000 SBL/2489 10 0446300000 Type Qty. Order No. G 20/0.10A/F 10 0430300000 G 20/0.20A/F 10 0430400000 G 20/0.25A/F 10 0430500000 G 20/0.50A/F 10 0430600000 G 20/1.00A/F 10 0430700000 G 20/1.60A/F 10 0430800000 G 20/2.00A/F 10 0430900000 G 20/2.50A/F 10 0431000000 G 20/3.15A/F 10 0431100000 G 20/4.00A/F 10 0431200000 G 20/5.00A/F 10 0431300000 100 0553300000 Width KOHUE ASK1 DEK 5/5 DEK 5/8 A.23 SAK-Series TS 35 Fuse terminals A SAKS 1/35 5x20 TS 35 / KrG 10 mm² SAKS 1/35 5x20 10 mm² With LED or glow lamp In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² 13 x 54 x 61 10 / 16 0.13...16 13 x 54 x 61 6.3 / 16 0.5...16 Technical data Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size V A mm² kV/- IEC 500 10 10 UL CSA 600 600 6.3 10 AWG 22...10 AWG 26...10 6/3 B6 / 5VA IEC 500 6.3 10 ?ru#~a mm² mm² mm/- Note UL CSA AWG 22...8 AWG 26...10 4/ B6 / 5VA # Rated connection 0.5...16 / 1.5...10 0.5...10 / 0.5...10 1.2...2.4 Nm (M 4) 12 / 1.0 x 5.5 mm Rated connection 0.5...16 / 1.5...10 0.5...10 / 0.5...10 1.2...2.4 Nm (M 4) 12 / 1.0 x 5.5 mm Connections for 10-mm² stranded conductors require a tightening torque of 2 Nm. Connections for 10-mm² stranded conductors require a tightening torque of 2 Nm. Type Type Ordering data Version 500 V AC/DC Qty. SAKS 1/35/G20 20 Order No. Qty. Order No. 0501620000 With GL 230 V AC/DC SAKS 1/35 G20 GL 230VAC 10 0199920000 With GL 115 V AC/DC SAKS 1/35 G20 GL 115VAC 10 8068330000 With LED 48 V AC SAKS 1/35 G20 LD 48VAC 10 0214020000 With LED 24 V AC SAKS 1/35 G20 LD 24VAC 10 1111320000 With LED +- 24 V DC SAKS 1/35 G20 LD 24VDC 10 0225820000 Type Qty. Order No. 500 V AC/DC Note Accessories current Qty. 2-pole Type QL 2 SAKS1 36 A 50 0191400000 3-pole QL 3 SAKS1 36 A 50 0191500000 4-pole QL 4 SAKS1 36 A 20 0191600000 10-pole QL 10 SAKS1 36 A 20 0338800000 20 0191320000 Screwable cross-connection End plate / Partition plate Width Medium yellow Marking systems AP SAKS1+3 KRG 3 mm Width AP SAKS1+3 KRG (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.24 Order No. DEK 5/5 An M 3 x 6 mm screw, with order no. 0346200000, should be used for the cross-connection. DEK 5/5 3 mm 20 0191320000 SAKS 1/35 5x25 10 mm² SAKS 1/35 5x25 10 mm² SAKS 3/35 10 mm² With glow lamp SAK-Series TS 35 Fuse terminals A 13 x 54 x 61 10 / 16 0.13...16 IEC 500 10 10 13 x 54 x 61 6.3 / 16 0.5...16 UL CSA 300 600 6.3 10 AWG 22...8 AWG 26...10 6/3 B6 / 5VA IEC 500 6.3 10 ?ru#~a 13 x 54 x 61 10 / 16 0.33...16 UL CSA IEC 500 10 10 AWG 22...8 AWG 26...10 4/ B6 / 5VA # Rated connection 0.5...16 / 1.5...10 0.5...10 / 0.5...10 1.2...2.4 Nm (M 4) 12 / 1.0 x 5.5 mm ?ru#~a Rated connection 0.5...16 / 1.5...10 0.5...10 / 0.5...10 1.2...2.4 Nm (M 4) 12 / 1.0 x 5.5 mm Rated connection 0.5...16 / 1.5...10 0.5...10 / 0.5...10 1.2...2.4 Nm (M 4) 12 / 1.0 x 5.5 mm Connections for 10-mm² stranded conductors require a tightening torque of 2 Nm. Connections for 10-mm² stranded conductors require a tightening torque of 2 Nm. Type Type Qty. SAKS 1/35/G25 20 Order No. UL CSA 300 600 10 10 AWG 22...8 AWG 22...10 6/3 B6 / 5VA Qty. Order No. 0501520000 SAKS 1/35 G25 GL 230VAC 10 Type Qty. Order No. SAKS 3/35 G/5X30 500V 20 0328920000 SAKS 3/35 GZ/6.3X32 20 0667520000 0198620000 SAKS 3 1‘‘x1/4‘‘ with a red cap available under 0667420000. Type current Qty. QL 2 SAKS1 36 A 50 0191400000 Order No. QL 3 SAKS1 36 A 50 0191500000 QL 4 SAKS1 36 A 20 0191600000 QL 10 SAKS1 36 A 20 0338800000 20 0191320000 Type Width AP SAKS1+3 KRG 3 mm Qty. Order No. Type 0191320000 AP SAKS1+3 KRG Width DEK 5/5 AP SAKS1+3 KRG DEK 5/5 3 mm Qty. Order No. Width 20 3 mm 20 0191320000 DEK 5/5 An M 3 x 6 mm screw, with order no. 0346200000, should be used for the cross-connection. A.25 SAK-Series TS 35 Fuse terminals A SAKS 2/35 TS 35 / KrG 10 mm² SAKS 4/35 10 mm² D 01-fuses In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data 27.6 x 80 x 75 10 / 16 0.33...16 24 x 75 x 66 16 / 16 0.33...16 IEC 60947-7-3 Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size V A mm² kV/- IEC 500 10 10 IEC 60947-7-3 UL CSA 600 25 AWG 22...8 6/3 B6 / 5VA IEC 400 16 10 ?ru#m mm² mm² mm/- Note UL CSA 600 30 AWG 22...8 6/3 B6 / 5VA ru#~ Rated connection 0.5...16 / 0.5...10 0.5...10 / 0.5...10 1.2...2.4 Nm (M 4) 12 / 1.0 x 5.5 mm Rated connection 0.5...16 / 1.5...10 0.5...10 / 0.5...10 1.2...2.4 Nm (M 4) 14 / 1.0 x 5.5 mm Connections for stranded conductors from 10 mm² and 7-wire AWG conductors require a tightening torque of 2 Nm. Connections for stranded conductors from 10 mm² and 7-wire AWG conductors require a tightening torque of 2 Nm. Type Ordering data Version Without LED Qty. SAKS 2/35 20 Order No. Type 1368720000 SAKS 4/35 Qty. 20 Order No. 0501820000 Note Accessories current Qty. Order No. Type current Qty. 2-pole Type QL 2 SAKS2 47 A 20 0207800000 QL 2 SAKS4 36 A 20 0328000000 3-pole QL 3 SAKS2 47 A 20 0207900000 QL 3 SAKS4 36 A 20 0328100000 4-pole QL 4 SAKS2 47 A 20 0208000000 QL 4 SAKS4 36 A 20 0328200000 10-pole QL 10 SAKS2 47 A 20 0338900000 QL 10 SAKS4 36 A 20 0339000000 Mounting screw BFSC M4X9T 100 0103300000 BFSC M4X9T 100 0103300000 SS M4 100 0136400000 SS M4 100 0136400000 Screwable cross-connection Lock washer D 128-A 4 D 128-A 4 Width Screw cover cap SK Order No. Width 25 0284110000 SK E14 SAKS4 20 0339410000 P 16/10 RT SAKS2 100 0208900000 P 14/2 D01 RS SAKS4 50 0138000000 P 16/16 GR SAKS2 100 0209000000 P 14/4 D01 BR SAKS4 50 0138100000 P 16/20 BL SAKS2 100 0209100000 P 14/10 D01 RT SAKS4 50 0328700000 P 14/6 D01 GN SAKS4 50 0328600000 SK E16/SAKS2 Gauge rings Fuse cartridges Marking systems 25 0208500000 E 14/2A RS 10 0137400000 E 16/16A GR TNDZ 25 0208600000 E 14/4A BR 10 0137500000 E 16/20A BL TNDZ 25 0208700000 E 14/6A GN 10 0328300000 E 16/25A GE TNDZ 25 0208800000 E 14/10A RT 10 0328400000 E 14/16A GR 10 0328500000 (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.26 E 16/10A RT TNDZ DEK 5/5 DEK 5/5 SAKS 4/35 USA 10 mm² 1 1/4“ x 1/4“ SAKS 5/35 SAK-Series TS 35 Fuse terminals 16 mm² D 02 - fuse A 24 x 75 x 73 30 / 16 0.5...16 28 x 80 x 66 63 / 16 1.5...16 IEC 60947-7-3 IEC 400 16 10 UL CSA 600 600 30 30 AWG 20...8 AWG 22...8 6/3 B6 / 5VA IEC 400 63 16 r#a UL CSA 600 600 40 63 AWG 14...6 AWG 14...6 6/3 B7 / 5VA ru#~a Rated connection 0.5...16 / 1.5...10 0.5...10 / 0.5...10 1.2...2.4 Nm (M 4) 14 / 1.0 x 5.5 mm Rated connection 1.5...16 / 1.5...16 1.5...16 / 1.5...16 1.2...2.4 Nm (M 4) 13 / 1.0 x 5.5 mm Connections for stranded conductors from 10 mm² and 7-wire AWG conductors require a tightening torque of 2 Nm. Connections for stranded conductors from 10 mm² and 7-wire AWG conductors require a tightening torque of 2 Nm. Type Qty. SAKS 4/35 USA Type 20 Order No. Type 0178220000 SAKS 5/35 Qty. 20 Order No. 0502120000 current Qty. Order No. Type current Qty. QL 2 SAKS4 36 A 20 0328000000 QL 2 SAKS2 47 A 20 0207800000 QL 3 SAKS4 36 A 20 0328100000 QL 3 SAKS2 47 A 20 0207900000 QL 4 SAKS4 36 A 20 0328200000 QL 4 SAKS2 47 A 20 0208000000 QL 10 SAKS4 36 A 20 0339000000 QL 10 SAKS2 47 A 20 0338900000 BFSC M4X9T 100 0103300000 BFSC M4X9T 100 0103300000 SS M4 100 0136400000 SS M4 100 0136400000 SK E18 SAKS5 20 0359310000 P 18/20 D02 BL SAKS5 50 0361800000 P 18/25 D02 GE SAKS5 50 0361900000 P 18/35 D02 SW SAKS5 50 0362000000 P 18/50 D02 WS SAKS5 50 0362100000 E 18/20A BL 10 0361300000 E 18/25A GE 10 0361400000 E 18/50A WS 10 0361600000 E 18/63A KU 10 0361700000 D 128-A 4 D 128-A 4 Width SK E14 SAKS4 USA DEK 5/5 Order No. Width 1 2012790000 DEK 5/5 Partition wall TW HP (2.0) order no. 0607000000 only for TS 32 A.27 SAK-Series TS 35 Fuse inserts and gauge rings for Weidmüller fuse terminals Fuse inserts Order data Technical data for terminal type SAKS 1 SAKS 7 ASK 1 WSI 6 G fuse inserts 5 x 20 without indicator acc. to IEC 60127-2 (VDE 0820 T.2 Bl 1) Size (mm) Rated voltage (V) Rated current (A) Type 0.1 (F) G 20/0.10A/F 5 x 20 Breaking capacity 1500 A (at 250 V, 50 Hz, cos, cos : 0.7) A 250 0.2 0.25 0.5 0.63 1.0 1.6 2.0 2.5 3.15 4.0 5.0 6.3 (F) (F) (F) (F) (F) (F) (F) (F) (F) (F) (F) (F) G 20/0.20A/F G 20/0.25A/F G 20/0.50A/F G 20/0.63A/F G 20/1.00A/F G 20/1.60A/F G 20/2.00A/F G 20/2.50A/F G 20/3.15A/F G 20/4.00A/F G 20/5.00A/F G 20/6.30A/F Qty. Order No. 10 0430300000 10 10 10 10 10 10 10 10 10 10 10 10 0430400000 0430500000 0430600000 0439000000 0430700000 0430800000 0430900000 0431000000 0431100000 0431200000 0431300000 0431400000 (M) = medium-delayed action (F) = fast SAKS 1 SAKS 7 WSI 6 G fuse inserts 5 x 25 with indicator acc. to DIN 41576 1) 0.25 5 x 25 m. K.1) Breaking capacity 80 A 0.5 (at 250 V, 50 Hz, cos : = 1) 0.8 250 1 10 2 4 6.3 (M) G 25/0.25A/M 10 0546900000 (M) (M) (M) (M)5) G 25/0.50A/M G 25/0.80A/M G 25/1.00A/M G 25/10.0A/M 10 10 10 10 (F) (F) (F) G 25/2.00A/F G 25/4.00A/F G 25/6.30A/F 10 10 10 0510300000 0646400000 0265800000 0193100000 0192700000 0192800000 0192900000 GZ 0.5A/F 10 0533800000 GZ 1.0A/F GZ 2.0A GZ 3.0A GZ 5.0A GZ 7.0A GZ 10.0A GZ 12.5A/FF 10 10 10 10 10 10 10 0525500000 0294500000 0295700000 0294600000 0295800000 0293900000 0245400000 E 16/10A RT 25 0208500000 E 16/16A GR E 16/20A BL E 16/25A GE 25 25 25 0208600000 0208700000 0208800000 10 0137400000 10 10 10 10 10 10 10 10 10 0137500000 0328300000 0328400000 0328500000 0361300000 0361400000 0361500000 0361600000 0361700000 M) = medium-delayed action (F) = fast SAKS 32) SAKS 6 Fuse inserts 1¼" x ¼" without indicator acc. to BS 88 0.5 33 kA Breaking capacity 33 kA fast E 0.5A 1 E 1 A 440 2 E 2 A 3 E 3 A 5 E 5 A 7 E 7 A 10 E 10 A 12.5 (F) = fast SAKS 2 D fuse inserts E 16 with indicator acc. to DIN 49360 (diazed) 10 E 10 A E 16 A 16 E 20 A 500 20 E 25 A 25 F) = fast SAKS 4 4) SAKS 5 (M) = medium-delayed action D fuse inserts E 14 Size D 01 and E 18 size D 02 with indicator acc. to DIN 49522 (neozed)3) 2 E 14/2A RS E 14/2 E 14/4 4 E 14/4A BR E 14/6 400 6 E 14/6A GN E 14/10 10 E 14/10A RT E 14/16 16 E 14/16A GR 20 E 18/20A BL E 18/20 25 E 18/25A GE E 18/25 400 35 E 18/35A SW E 18/35 50 E 18/50A WS E 18/50 E 18/63 63 E 18/63A KU (F) = fast Note: A.28 (M) = miedium-delayed action (M) = medium-delayed action ) The SIBA company also supplies 5 x 25 G fuse inserts with indicators in a shipbuilding model for 450 V AC. ) 5 x 30 (500 V AC) fuse inserts for SAKS 3 are available from the WICKMANN company ) The LINDNER company also supplies neozed fuse cartridges in an additional shipbuilding mode for 440 V AC. 4 ) Fuse cartridges with the dimensions 1“x1/4“ c 25.4x6.35 mm and 13/32“x11/2“ c 10.3x38.1 mm are not included in product line. 5 ) Only for SAKS 1 and SAKS 7. 1 2 3 Gauge rings Technical data Order data for terminal type Gauge ring type Amp. SAKS 4 and 4/35 P 14/2 2 P 14/4 P 14/6 P 14/1 4 6 10 Colour Type Qty. Order No. pink P 14/2D01 RS 50 0138000000 brown green red P 14/4D01 BR P 14/6D01 GN P 14/10D01 RT 50 50 50 0138100000 0328600000 0328700000 SAK-Series TS 35 Fuse inserts and gauge rings for Weidmüller fuse terminals A SAKS 5 and 5/35 P 18/20 P 18/25 P 18/35 P 18/50 20 25 35 50 blue yellow black white P 18/20D02 BL P 18/25D02 GE P 18/35D02 SW P 18/50D02 WS 50 50 50 50 0361800000 0361900000 0362000000 0362100000 SAKS 2 and 2/35 P 16/10 P 16/16 P 16/20 10 16 20 red grey blue P 16/10 RT P 16/16 GR P 16/20 BL 100 100 100 0208900000 0209000000 0209100000 A.29 SAK-Series TS 35 Installation terminals A NT 2.5/35 TS 35 / PA 2.5 mm² NT 6/35 6 mm² These NT modular terminals are prescribed for insulation measurements without detaching the conductors according to VDE standards for places of public assembly. In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data 6 x 45 x 44 24 / 4 0.33...4 8 x 49 x 44 41 / 10 0.5...10 NT IEC 60947-7-1 Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size IEC 400 24 2.5 V A mm² kV/- IEC 60947-7-1 UL CSA 300 300 20 25 AWG 22...12 AWG 22...12 6/3 A3 / V2 IEC 400 41 6 r#a mm² mm² mm/- Note NT UL CSA 300 300 40 40 AWG 22...8 AWG 20...10 6/3 A5 / 5VA r#a Rated connection 0.5...4 / 0.5...4 0.5...0.5 / 0.5...2.5 0.5...0.8 Nm (M 2.5) 10 / 0.6 x 3.5 mm Rated connection 0.5...10 / 0.5...10 0.5...10 / 0.5...6 0.8...1.4 Nm (M 3.5) 12 / 0.8 x 4 mm Tightening torque via disconnector is 0.5 ... 0.8 Nm. Tightening torque via disconnector is 0.5 ... 0.8 Nm. Ordering data Version Blue Type Qty. Order No. Type Qty. Order No. NT 2.5/35 10X3 BL 100 0471780000 NT 6/35 10X3 KRG/BL 100 0501470000 Note Accessories Support bracket for 10 x 3 (required every 20 cm) Type Blue Width Qty. Order No. Type Width Qty. HP NT2.5 BL 1.5 mm 20 0352080000 HP NT6/10 BL 1.5 mm 20 0352880000 Order No. SSCH 10X3X1000 CU/SN 10 mm 1 0348900000 SSCH 10X3X1000 CU/SN 10 mm 1 0348900000 ZB 4 5.6 mm 50 0316500000 ZB 4 5.6 mm 50 0316500000 ZB 16 ZKSC 10 mm 50 0316600000 ZB 16 ZKSC 10 mm 50 0316600000 ZB 35/M6X16 14 mm 20 0266500000 ZB 35/M6X16 14 mm 20 0266500000 Busbar 10 x 3 (140 A) OK, Busbar up to OK, TS35 = 25,5 mm Clamping yoke for power supply to 10 x 3 busbars Rigid / flexible 0,5 - 6 / 4 mm² rigid / flexible 6 - 16 mm² Flexible 16 - 35 mm² Marking systems (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.30 DEK 5/6 DEK 5/6 Refer to the „Accessories“ section for PEN bridges and additional clamping-yoke versions. Use of twin wire-end ferrules on request. Refer to the „Accessories“ section for PEN bridges and additional clamping-yoke versions. Use of twin wire-end ferrules on request. NT 10/35 10 mm² NT 16/35 SAK-Series TS 35 Installation terminals 16 mm² A 10 x 45 x 44 57 / 16 0.5...16 12 x 59.5 x 58 76 / 16 2.5...16 NT IEC 60947-7-1 IEC 400 57 10 NT IEC 60947-7-1 UL CSA 300 300 50 50 AWG 14...8 AWG 14...8 6/3 B6 / V2 IEC 400 76 16 r#a UL CSA 300 300 65 70 AWG 16...6 AWG 12...6 6/3 B6 / V2 r#a Rated connection 0.5...16 / 0.5...10 0.5...10 / 0.5...10 1.2...1.6 Nm (M 4) 12 / 1.0 x 5.5 mm Rated connection 2.5...16 / 2.5...10 2.5...16 / 2.5...2.5 1.2...1.6 Nm (M 4) 12 / 1.0 x 5.5 mm Tightening torque via disconnector is 0.5 ... 0.8 Nm. Fix 10 mm² stranded connection with 2 Nm tightening torque. Isolator can accommodate 0.8..1.4 Nm. 10 and 16 mm² stranded and AWG 8/7 connections are to be fixed with 2.4 Nm tightening torque. Type Qty. NT 10/35 10X3 BL Type 50 Order No. Type 0471880000 NT 16/35 10X3 BL Qty. Order No. 0499280000 50 Width Qty. Order No. Type Width Qty. HP NT6/10 BL 1.5 mm 20 0352880000 HP NT16/10X3 2 mm 20 1266380000 Order No. SSCH 10X3X1000 CU/SN 10 mm 1 0348900000 SSCH 10X3X1000 CU/SN 10 mm 1 0348900000 ZB 4 5.6 mm 50 0316500000 ZB 4 5.6 mm 50 0316500000 ZB 16 ZKSC 10 mm 50 0316600000 ZB 16 ZKSC 10 mm 50 0316600000 ZB 35/M6X16 14 mm 20 0266500000 ZB 35/M6X16 14 mm 20 0266500000 DEK 5/6 DEK 5/5 Refer to the „Accessories“ section for PEN bridges and additional clamping-yoke versions. Use of twin wire-end ferrules on request. Refer to the „Accessories“ section for PEN bridges and additional clamping-yoke versions. Use of twin wire-end ferrules on request. A.31 SAK-Series TS 35 Test-disconnect terminals A SAKT 1/LT TS 35 / KrG 6 mm² SAKT 1/DU1 6 mm² In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data 8 x 65 x 52.5 57 / 10 0.13...10 8 x 65 x 52.5 57 / 10 0.13...10 IEC 60947-7-1 Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Tightening torque range Stripping length / Blade size V A mm² kV/- IEC 400 41 6 IEC 60947-7-1 UL CSA 300 300 25 25 AWG 22...8 AWG 26...8 6/3 A5 / 5VA IEC 400 41 6 r#a mm² mm² mm/- Note UL CSA 300 300 25 25 AWG 22...8 AWG 26...8 6/3 A5 / 5VA r#a Rated connection 0.5...10 / 1.5...10 0.5...6 / 0.5...6 0.8...1.6 Nm (M 3.5) 0.5...0.8 Nm 12 / 4.0 x 0.8 mm Rated connection 0.5...10 / 1.5...10 0.5...6 / 0.5...6 0.8...1.6 Nm (M 3.5) 12 / 4.0 x 0.8 mm 10 mm² stranded and AWG 8/7 connections are to be fixed with 1.6 Nm tightening torque. 10 mm² stranded and AWG 8/7 connections are to be fixed with 1.6 Nm tightening torque. Type Type Ordering data Version Without socket Qty. Order No. SAKT 1/35/LT 50 0105420000 SAKT 1/35/LT STB 50 0105620000 With open rear wall for cross-connection With 2 sockets Qty. SAKT 1/35/DU1 50 Order No. 0105820000 With 4 sockets Note Accessories Screwable cross-connection current Qty. Order No. Type current Qty. 2-pole Type QL 2 SAK6N 57 A 50 0194300000 QL 2 SAK6N 32 A 50 0194300000 3-pole QL 3 SAK6N 57 A 50 0194400000 QL 3 SAK6N 57 A 50 0194400000 4-pole QL 4 SAK6N 57 A 50 0194500000 QL 4 SAK6N 57 A 50 0194500000 10-pole QL 10 SAK6N 57 A 20 0338300000 QL 10 SAK6N 32 A 20 0338300000 VH 12/4.9/3.3 SAK6N 100 0249000000 VH 12/4.9/3.3 SAK6N 100 0249000000 KISC M3X20 SAK10 CU5 100 0377100000 KISC M3X20 SAK10 CU5 100 0377100000 Connecting sleeve Mounting screw End plate / Partition plate Width Medium yellow beige AP SAKB/C/T KRG TW SAKB/C/T1 Order No. Width 3 mm 20 0146720000 AP SAKB/C/T KRG 1.5 mm 20 0242960000 TW SAKB/C/T1 0.6 mm 100 0353660000 TSCH 2 3 mm 20 0146720000 1.5 mm 20 0242960000 0.6 mm 100 0353660000 Small partition Small partition TSCH 2 Cross-connection slider current current 2-pole QVS 2 SAKT1+2 20 0307300000 QVS 2 SAKT1+2 41 A 20 0307300000 3-pole QVS 3 SAKT1+2 20 0329300000 QVS 3 SAKT1+2 41 A 20 0329300000 4-pole QVS 4 SAKT1+2 20 0307400000 QVS 4 SAKT1+2 41 A 20 0307400000 VH 19/6/4.2 SAKT1 50 0318000000 VH 19/6/4.2 SAKT1 50 0318000000 BS 25 O.IH SAKT1 50 0334700000 BS 25 O.IH SAKT1 50 0334700000 20 0299600000 50 0169900000 100 0531760000 20 0270960000 Connecting sleeve for QVS Mounting screw for QVS Testing / Checking Width Test plug Socket PS 4 F.STB 4 STB 14/D6/4/M3 SAK10 7.6 mm Width 20 0299600000 PS 4 F.STB 4 50 0169900000 STB 14/D6/4/M3 SAK10 100 0531760000 SSP 3 SAKT1 20 0270960000 QS 2/8/4 7.6 mm Miscellaneous accessories Lockout device Short-circuit plug, 2-pole Marking systems QS 2/8/4 (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.32 SSP 3 SAKT1 DEK 5/6,5 DEK 5/6,5 To safe the test sockets use the SDIZ-blade (see chapter Tools) or bits with pilots! To safe the test sockets use the SDIZ-blade (see chapter Tools) or bits with pilots! SAKT 1/QT 6 mm² SAKT 2/LT 6 mm² SAKT 4/35/LT 4 mm² SAK-Series TS 35 Test-disconnect terminals A 8 x 65 x 52.5 57 / 10 0.13...10 8 x 82 x 52.5 46 / 10 0.5...10 IEC 60947-7-1 IEC 400 41 6 6 x 57.2 x 40 41 / 6 0.13...6 IEC 60947-7-1 UL CSA 300 300 25 25 AWG 22...8 AWG 26...8 6/3 A5 / 5VA IEC 125 41 6 r#a IEC 60947-7-1 UL CSA 300 25 AWG 22...8 6/3 A5 / 5VA IEC 400 32 4 r#a Rated connection 0.5...10 / 1.5...10 0.5...6 / 0.5...6 0.8...1.6 Nm (M 3.5) 0.5...0.8 Nm 12 / 4.0 x 0.8 mm UL CSA 300 300 20 20 AWG 22...12 AWG 26...10 6/3 A3 / 5VA # Rated connection 0.5...10 / 1.5...10 0.5...6 / 0.5...6 1.2...1.6 Nm (M 3.5) 0.5...0.8 Nm 12 / 4.0 x 0.8 mm Rated connection 0.5...6 / 1.5...4 0.5...4 / 0.5...4 0.4...0.7 Nm (M 2.5) 0.4...0.7 Nm 10 / 0.6 x 3.5 mm 10 mm² stranded and AWG 8/7 connections are to be fixed with 1.6 Nm tightening torque. 10 mm² stranded and AWG 8/7 connections are to be fixed with 1.6 Nm tightening torque. Two conductors with the same cross-section can be accommodated. 1.5 mm² solid and 0.5...1.5 mm² flexible Type Type Type Qty. Order No. SAKT 1/35/QT2 50 0124620000 SAKT 1/35/QT1 50 0105720000 Type Qty. Order No. SAKT 2/35/LT/STB 50 0105920000 SAKT 2/35/LT 4STB 50 0106020000 Qty. Order No. SAKT 4/35/LT O.STB 50 1272420000 SAKT 4/35/LT STB2.0 50 1272520000 current Qty. Order No. Type current Qty. Order No. Type current Qty. Order No. QL 2 SAK6N 57 A 50 0194300000 QL 2 SAK6N 32 A 50 0194300000 QL 2 SAK2.5 41 A 100 0155900000 QL 3 SAK6N 57 A 50 0194400000 QL 3 SAK6N 57 A 50 0194400000 QL 3 SAK2.5 41 A 100 0156000000 QL 4 SAK6N 57 A 50 0194500000 QL 4 SAK6N 57 A 50 0194500000 QL 4 SAK2.5 41 A 50 0156100000 QL 10 SAK6N 57 A 20 0338300000 QL 10 SAK6N 32 A 20 0338300000 QL 10 SAK2.5 41 A 20 0338100000 VH 12/4.9/3.3 SAK6N 100 0249000000 VH 12/4.9/3.3 SAK6N 100 0249000000 VH 8/4.9/3.3 SAK2.5 100 0266700000 KISC M3X20 SAK10 CU5 100 0377100000 KISC M3X15/6 SAK2.5 CU5 100 0377200000 3 mm 20 0146720000 1.5 mm 20 0242960000 TW SAKT2 20 0474700000 0.6 mm 100 0353660000 TSCH 2 100 0353660000 QVS 2/4 SAKT4 20 1319260000 TW SAKB/C/T1 TSCH 2 Width Width Width AP SAKB/C/T KRG current 2.5 mm 20 0351820000 TW AST1/PA HP/DBR/0.5 0.5 mm 0.6 mm 100 0353660000 TSCH 2 0.6 mm current current QVS 2 SAKT1+2 20 0307300000 QVS 2 SAKT1+2 41 A 20 0307300000 QVS 3 SAKT1+2 20 0329300000 QVS 3 SAKT1+2 41 A 20 0329300000 QVS 4 SAKT1+2 20 0307400000 QVS 4 SAKT1+2 41 A 20 0307400000 VH 19/6/4.2 SAKT1 50 0318000000 VH 19/6/4.2 SAKT1 50 0318000000 VH 16/5/3.5 SAK10-35 50 0309700000 BS 25 O.IH SAKT1 50 0334700000 BS 25 O.IH SAKT1 50 0334700000 BFSC M3X22 SAKT4 50 1319900000 Width PS 4 F.STB 4 STB 14/D6/4/M3 SAK10 SSP 3 SAKT1 QS 2/8/4 7.6 mm Width Width 20 0299600000 PS 4 F.STB 4 50 0169900000 STB 14/D6/4/M3 SAK10 100 0531760000 SSP 3 SAKT1 20 0270960000 QS 2/8/4 7.6 mm 20 0299600000 PS 2.0 OR 20 0293800000 50 0169900000 STB 8.5/D4.5/2/M3 SAKT4 50 0244600000 100 0531760000 SSP 4 SAKT4 20 1319360000 20 0270960000 5.4 mm DEK 5/6,5 DEK 5/6,5 DEK 5/6,5 To safe the test sockets use the SDIZ-blade (see chapter Tools) or bits with pilots! To safe the test sockets use the SDIZ-blade (see chapter Tools) or bits with pilots! To safe the test sockets use the SD-blade or bits with pilots! A.33 SAK-Series TS 35 Terminals for temperature measuring circuits A DK 4 Q/TC TS 35 / PA 4 mm² Busbars made from thermocouple materials according to DIN IEC 584 In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data 6 x 54 x 59.5 /4 ...4 Weidmüller thermocouple terminals are specially designed for the transmission of very small voltages in temperature measuring circuits. Special current bars ensure that no false signals are transmitted within the terminal when temperature differences between the positive and negative paths exist. This high measuring precision is required, for example, in aircraft engine test rigs, complicated chemical processes, controllers, etc. IEC 60947-7-1 / IEC 60584 Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size IEC V A mm² kV/- UL CSA 4 • Material of current bar corresponds to thermal and compensating conductors A3 / V2 # mm² mm² mm/- Rated connection 0.5...4 / 1.5...4 0.5...4 / 0.5...2.5 0.5...1.0 Nm (M 3) 9 / 0.6 x 3.5 mm • Clear thermocouple marking • 2-pole blocks per thermocouple • Modular width 10 mm Note Configuration of a temperature measuring circuit Ordering data 1 Version Type Qty. Order No. (NiCr - Ni) type K DK 4Q/35/TC TYP K 100 1284160000 (Cu - CuNi) type T DK 4Q/35/TC TYP T 100 1285660000 (Fe-CuNi) type J DK 4Q/35/TC TYP J 100 1284060000 Note 2 3 End plate / Partition plate Type Width Qty. 1.5 mm 20 1397160000 TW SAKS2 HP/DBR/2 2 mm 20 0607000000 WTW EN 3 mm 20 1058800000 beige AP DK4Q beige Dark beige Wemid Order No. 5 6 CH AL 1 Thermocouple (sensor) 2 Thermocouple terminals 3 Compensating conductor Accessories 4 4 Reference junction 5 Supply and return conductors 6 Measuring instrument The thermocouple terminals shown in this measuring circuit are used for the thermoelectrical transmission of the thermoelectric voltage from the thermocouple to the reference junction and the indicator unit via the compensating conductor. Thermocouple terminals are required for constructing a temperature measuring circuit. Technical data Thermocouples to IEC 584 (DIN 43 710) Terminal a) Type J Fe (positive leg) CuNi (negative leg) b) Type T Cu (positive leg) CuNi (negative leg) Marking systems (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.34 c) Type K NiCr (positive leg) Ni (negative leg) DEK 5/6 Busbar material trade name Iron Constantan Copper Constantan Chromel Alumel A A.35 SAK-Series TS 35 SAK-Series TS 35 Terminals with screw-less connections A With tab connection TS 35 / PA AST 1 / 35 2.5 mm² AST 3/35 2.5 mm² In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data 6.5 x 58 x 46 20 / 2.5 0.5...2.5 6,3 6,3 2,8 2,8 6,3 6,3 2,8 2,8 IEC 60947-7-1 / IEC 61210 Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size V A mm² kV/- IEC 500 20 2.5 6,3 2,8 6,3 2,8 IEC 60947-7-1 / IEC 61210 UL 600 13 CSA 300 16 IEC 500 20 2.5 UL 300 13 6/3 / V2 CSA 300 16 6/3 / V2 ru#a r#a Rated connection mm² mm² 6.5 x 40 x 40.1 20 / 2.5 ...2.5 Rated connection 0.5...2.5 0.5...2.5 The rated voltage is 800 V when using a cable-lug (flat) connector with IH 6.3 insulating sleeves. Cable-lug connections should be fitted with insulating sleeves. 20 A with F 6.3 or 2 x F 2.8 Type mm/- Note Ordering data Version Order No. Type Qty. Order No. Slotted AST 1/35 6.3/2.8 50 0699660000 AST 3/35 6.3/2.8 100 0460360000 Not slit AST 1/35 6.3 50 0664860000 AST 3/35 6.3 100 0479360000 Note Qty. Cable-lug connections should be connected with insulating sleeves. 20 A with F 6.3 or 2 x F 2.8 Accessories Screwable cross-connection current Qty. Order No. Type current Qty. 2-pole Type Q 2 SAK4 41 A 50 0336700000 Q 2 SAK4 41 A 50 0336700000 3-pole Q 3 SAK4 41 A 50 0336800000 Q 3 SAK4 41 A 50 0336800000 4-pole Q 4 SAK4 41 A 50 0336900000 Q 4 SAK4 41 A 50 0336900000 10-pole Q 10 SAK4 41 A 20 0368800000 Q 10 SAK4 41 A 20 0368800000 Plug-in adapter Order No. Width 2-pole STA 2.5/2 100 0165860000 3-pole STA 2.5/3 50 0165960000 4-pole STA 2.5/4 50 0190360000 5-pole STA 2.5/5 50 0166060000 8-pole STA 2.5/8 50 0166160000 End plate / Partition plate Width beige 1.5 mm 20 0266400000 TW SAKS2 HP/DBR/2 2 mm 20 0607000000 TW 4 SAK4-10 TSCH 1 2 mm 100 0319160000 TSCH 1 5.4 mm 20 0180400000 PS 2.3 RT 50 0168600000 STB 14/D5/2.3/M3 SAK2.5 AP AST1+5 DB Medium yellow beige AP AST3+4 KRG 3 mm 20 0298120000 1.5 mm 20 0130160000 2 mm 100 0319160000 5.4 mm 20 0180400000 50 0168600000 Small partition Small partition Testing / Checking Test plug Socket PS 2.3 RT STB 14/D5/2.3/M3 SAK2.5 Insulating sleeve Marking systems 2,8 IH 2.8 DB 100 0386060000 IH 2.8 DB 100 0386060000 6,3 IH 6.3 WEM GE 100 0386260000 IH 6.3 WEM GE 100 0386260000 (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.36 DEK 5/6 DEK 5/6 Pluggable adapter STA 2,5/2 - STA 2,5/8 only for PA - Version. AST 4/35 2.5 mm² AST 5/35 4 mm² SAK 4 S/35 4 mm² SAK-Series TS 35 Terminals with screw-less connections A 6.2 x 40 x 40.1 20 / 4 0.2...4 6,3 2,8 IEC 60947-7-1 / IEC 61210 IEC 500 20 2.5 6.5 x 58 x 46 20 / 6 0.2...6 6,3 2,8 6,3 2,8 6,3 2,8 IEC 60947-7-1 / IEC 61210 UL CSA 300 300 13 16 AWG 22...12 AWG 24...12 6/3 A3 / V2 IEC 500 20 4 ru#a 6,3 2,8 6,3 2,8 IEC 60947-7-1 / IEC 61210 UL CSA 300 300 13 16 AWG 22...12 AWG 24...12 6/3 A4 / V2 IEC 500 20 4 ru#a Rated connection 0.5...4 / 1.5...2.5 0.5...2.5 / 0.5...2.5 0.4...0.7 Nm (M 2.5) 9 / 0.6 x 3.5 mm 6.5 x 40 x 49.5 20 / 6 0.13...6 UL CSA 600 300 13 13 AWG 26...12 AWG 26...12 6/3 A4 / V2 ru#a Rated connection 0.5...6 / 1.5...2.5 0.5...4 / 0.5...4 0.5...1.0 Nm (M 3) 12 / 0.6 x 3.5 mm Rated connection 0.5...6 / 1.5...4 0.5...4 / 0.5...4 0.5...1.0 Nm (M 3) 12 / 0.6 x 3.5 mm The rated voltage is 800 V when using a cable-lug (flat) connector with IH 6.3 insulating sleeves. The rated voltage is 800 V when using a cable-lug (flat) connector with IH 6.3 insulating sleeves. The rated voltage is 800 V when using a cable-lug (flat) connector with IH 6.3 insulating sleeves. Type Qty. Order No. Type Order No. Type Qty. Order No. AST 4/35 SF 6.3/2.8 100 0460460000 AST 5/35 SF 6.3/2.8 0664960000 SAK 4 S/35 6.3/2.8 100 0630360000 AST 4/35 SF 6.3 100 0479460000 Qty. 50 Cable-lug connections should be connected with insulating sleeves. 20 A with F 6.3 or 2 x F 2.8 Cable-lug connections should be connected with insulating sleeves. 20 A with F 6.3 or 2 x F 2.8 Cable-lug connections should be connected with insulating sleeves. 20 A with F 6.3 or 2 x F 2.8 Type current Qty. Order No. Type current Qty. Order No. Type current Qty. Order No. Q 2 SAK4 41 A 50 0336700000 Q 2 SAK4 41 A 50 0336700000 QL 2 SAK4 32 A 100 0130600000 Q 3 SAK4 41 A 50 0336800000 Q 3 SAK4 41 A 50 0336800000 QL 3 SAK4 32 A 100 0130700000 Q 4 SAK4 41 A 50 0336900000 Q 4 SAK4 41 A 50 0336900000 QL 4 SAK4 32 A 50 0130800000 Q 10 SAK4 41 A 20 0368800000 Q 10 SAK4 41 A 20 0368800000 QL 10 SAK4 32 A 20 0338200000 STA 2.5/2 100 0165860000 STA 2.5/3 50 0165960000 STA 2.5/4 50 0190360000 STA 2.5/5 50 0166060000 STA 2.5/8 50 0166160000 Width Width Width AP SAK2.5/35 + AST3+4 1.5 mm 20 0460560000 AP AST1+5 DB 1.5 mm 20 0266400000 AP SAK4-10 1.5 mm 20 0117960000 TW 4 SAK4-10 1.5 mm 20 0130160000 TW AST1/PA HP/DBR/0.5 0.5 mm 20 0474700000 TW 4 SAK4-10 1.5 mm 20 0130160000 2 mm 100 0319160000 5.4 mm 20 0180400000 PS 2.3 RT 20 0180400000 PS 2.3 RT 5.4 mm 20 0180400000 50 0168600000 STB 14/D5/2.3/M3 SAK2.5 50 0168600000 STB 14/D5/2.3/M3 SAK2.5 50 0168600000 IH 2.8 DB 100 0386060000 IH 2.8 DB 100 0386060000 IH 2.8 DB 100 0386060000 IH 6.3 WEM GE 100 0386260000 IH 6.3 WEM GE 100 0386260000 IH 6.3 WEM GE 100 0386260000 TSCH 1 PS 2.3 RT STB 14/D5/2.3/M3 SAK2.5 DEK 5/6 DEK 5/6,5 5.4 mm DEK 5/6,5 Pluggable adapter STA 2,5/2 - STA 2,5/8 only for PA - Version. A.37 SAK-Series TS 35 Terminals with screw-less connections A With tab connection TS 35 / PA SAK 4 SS/35 2.5 mm² DK 4 SS/35 2.5 mm² In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data 6.5 x 40 x 49.5 20 / 2.5 0.5...2.5 6,3 2,8 6,3 2,8 6,3 2,8 6,3 2,8 IEC 60947-7-1 / IEC 61210 Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size V A mm² kV/- IEC 500 20 2.5 6,3 2,8 6,3 2,8 6,3 2,8 6,3 2,8 IEC 60947-7-1 / IEC 61210 UL CSA 600 300 13 13 AWG 26...12 AWG 26...12 6/3 / V2 IEC 400 20 2.5 ?ru#a UL CSA 300 300 10 10 AWG 22...12 AWG 22...12 4/3 / V2 ru#~a Rated connection mm² mm² 6 x 54 x 60.5 20 / 2.5 0.5...2.5 Rated connection 0.5...2.5 0.5...2.5 The rated voltage is 800 V when using a cable-lug (flat) connector with IH 6.3 insulating sleeves. Cable-lug connections should be fitted with insulating sleeves. 20 A with F 6.3 and 2 x F 2.8 Type Qty. Order No. Type Qty. Order No. SAK 4 SS/35 6.3/2.8 100 0630460000 DK 4SS/35 FF 4X6.3/2.8 100 0217160000 mm/- Note Ordering data Version Slotted Not slit Note Cable-lug connections should be connected with insulating sleeves. 20 A with F 6.3 or 2 x F 2.8 Accessories Screwable cross-connection current Qty. Order No. Type current Qty. 2-pole Type QL 2 SAK4 32 A 100 0130600000 Q 2 AKZ4 32 A 50 0336400000 Order No. 3-pole QL 3 SAK4 32 A 100 0130700000 Q 3 AKZ4 32 A 50 0336500000 4-pole QL 4 SAK4 32 A 50 0130800000 Q 4 AKZ4 32 A 50 0336600000 10-pole QL 10 SAK4 32 A 20 0338200000 Q 10 AKZ4 32 A 20 0368600000 AP SAK4-10 1.5 mm 20 0117960000 AP DK4S 20 0631360000 TW 4 SAK4-10 1.5 mm 20 0130160000 5 mm 100 0190260000 5.4 mm 20 0180400000 50 0215700000 Plug-in adapter 2-pole 3-pole 4-pole 5-pole 8-pole End plate / Partition plate Width beige Width Medium yellow beige Small partition Small partition TSCH 6 DKI S4 Testing / Checking Test plug PS 2.3 RT Socket STB 8.5/D4/2.3/M2.5 AKZ Insulating sleeve Marking systems 2,8 IH 2.8 DB 100 0386060000 IH 2.8 DB 100 0386060000 6,3 IH 6.3 WEM GE 100 0386260000 IH 6.3 WEM GE 100 0386260000 (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.38 DEK 5/6,5 DEK 5/6 DK 4 S SAK-Series TS 35 Terminals with screw-less connections 4 mm² A 6 x 54 x 59.5 20 / 4 0.33...4 6,3 2,8 6,3 2,8 IEC 60947-7-1 / IEC 61210 IEC 400 10 4 UL CSA 300 300 10 10 AWG 22...12 AWG 22...12 6/3 A3 / V2 ru#~a Rated connection 0.5...4 / 1.5...4 0.5...4 / 0.5...2.5 0.5...0.8 Nm (M 3) 8 / 0.6 x 3.5 mm Cable-lug connections should be fitted with insulating sleeves. 20 A supplied via F 6.3 or 2 x F 2.8. Type Qty. Order No. DK 4S/35 SF 6.3/2.8 100 0686660000 Type current Qty. Q 2 AKZ4 32 A 50 0336400000 Order No. Q 3 AKZ4 32 A 50 0336500000 Q 4 AKZ4 32 A 50 0336600000 Q 10 AKZ4 32 A 20 0368600000 20 0631360000 5 mm 100 0190260000 5.4 mm 20 0180400000 50 0215700000 IH 2.8 DB 100 0386060000 IH 6.3 WEM GE 100 0386260000 Width AP DK4S TSCH 6 DKI S4 PS 2.3 RT STB 8.5/D4/2.3/M2.5 AKZ DEK 5/6 A.39 SAK-Series TS 35 Terminals with screw-less connections A with solder connection TS 35 / PA SAK 2.5 LL 1.5 mm² solder connection both sides In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data 6 x 55 x 46.5 17.5 / 1.5 0.13...1.5 IEC 60947-7-1 / IEC 60068-2-20 Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size IEC 250 17.5 1.5 V A mm² kV/- UL CSA 300 10 AWG 26...12 4/3 / V2 # mm² mm² Rated connection 0.5...1.5 0.5...1.5 mm/- Note Solder connection both sides with max. 1.5 mm² conductor Ordering data Version beige Type Qty. Order No. SAK 2.5/35 LL 100 0567260000 Note Accessories Screwable cross-connection current Qty. 10-pole Type Q 10 SAK2.5 41 A 20 0368700000 2-pole Q 2 SAK2.5 41 A 50 0337000000 3-pole Q 3 SAK2.5 41 A 50 0337100000 4-pole Q 4 SAK2.5 41 A 50 0337200000 Testing / Checking Order No. Width Socket Test plug 50 0280600000 PS 2.3 RT 5.4 mm 20 0180400000 AP SAK2.5 1.5 mm 20 0279560000 AP SAK2.5 BL 1.5 mm 20 0279580000 TW SAK2.5 2.5 mm 20 0302860000 TW SAK2.5 HP/TF/GE/1 1 mm 20 0297100000 TSCH 1 2 mm 100 0319160000 50 0303400000 100 0128900000 STB 8.5/5/2.3/M3 SAK2.5 End plate / Partition plate beige Blue beige Tropical applications Small partition Small partition Cover / warning label Cover / warning label Mounting screw (plastic) Marking systems BFSC M3X22 PA/RT (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.40 AD 4 AKZ4 DEK 5/6 A A.41 SAK-Series TS 35 SAK-Series TS 35 Special terminals - SAKG A SAKG 32 I TS 35 / KrG 50 mm² In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data 32 x 87 x 84.5 192 / 70 10...70 IEC 60947-7-1 Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size V A mm² kV/- IEC 1000 150 50 UL CSA 600 600 165 170 AWG 6...3/0 AWG 1...2/0 8/3 B11 / 5VA ?ru#a mm² mm² mm/- Rated connection 10...16 / 10...70 10...70 / 10...70 6.0...12 Nm (M 8) 26 / Note Ordering data Version Type Medium yellow Qty. SAKG 32/35 I Order No. 0637120000 10 Note Accessories Screwable cross-connection current Qty. 2-pole Type QL 2 SAKG32+70 150 A 5 0194000000 3-pole QL 3 SAKG32+70 150 A 5 0441500000 4-pole QL 4 SAKG32+70 150 A 5 0441600000 End plate / Partition plate Order No. Width dark brown Tropical applications dark brown Tropical applications EP 2 SAKG46/35 HP/DBR 2 mm 10 0180700000 EP 2 SAKG46/35 HP/TF/GE 2 mm 10 0180800000 TW SAKG46 HP/DBR/2 2 mm 10 0177100000 TW SAKG46 HP/TF/GE/2 2 mm 10 0179900000 30 mm 5 0326760000 Cover / warning label Cover / warning label Marking systems (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.42 AH 32 SAKG32 DEK 5/5 SAKG 32 II TS 35 / KrG 50 mm² SAKG 32 II G 50 mm² A In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data 32 x 80 x 53 192 / 70 10...70 32 x 80 x 53 192 / 70 10...70 IEC 60947-7-1 Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size V A mm² kV/- IEC 1000 150 50 IEC 60947-7-1 UL CSA 600 600 200 170 AWG 6...3/0 AWG 1...2/0 8/3 / 5VA IEC 1000 150 50 ?ru#a UL CSA 600 600 200 170 AWG 6...3/0 AWG 1...2/0 8/3 / 5VA ?ru#a Rated connection Rated connection mm² mm² 6.0...12 Nm (M 8) 6.0...12 Nm (M 8) Conductor connection with cable lugs according to DIN 46234 and DIN 46235, from 10 .. 70 mm² Conductor connection with cable lugs according to DIN 46234 and DIN 46235, from 10 .. 70 mm² Type mm/- Note Ordering data Version Medium yellow Qty. SAKG 32/35 II 10 Order No. Type 0637320000 SAKG 32/35 II/GW Qty. Order No. 0637420000 10 Note Accessories Screwable cross-connection current Qty. Order No. Type current Qty. 2-pole Type QL 2 SAKG32+70 150 A 5 0194000000 QL 2 SAKG32+70 150 A 5 0194000000 3-pole QL 3 SAKG32+70 150 A 5 0441500000 QL 3 SAKG32+70 150 A 5 0441500000 4-pole QL 4 SAKG32+70 150 A 5 0441600000 QL 4 SAKG32+70 150 A 5 0441600000 End plate / Partition plate Width dark brown Tropical applications dark brown Tropical applications Order No. Width EP 2 SAKG46/35 HP/DBR 2 mm 10 0180700000 EP 1 SAKG32/35 HP/DBR 2 mm 10 0180500000 EP 2 SAKG46/35 HP/TF/GE 2 mm 10 0180800000 EP 1 SAKG32/35 HP/TF/GE 2 mm 10 0180600000 TW SAKG46 HP/DBR/2 2 mm 10 0177100000 TW SAKG28 HP/DBR/2 2 mm 10 0151400000 TW SAKG46 HP/TF/GE/2 2 mm 10 0179900000 TW SAKG28 HP/TF/GE/2 2 mm 10 0164600000 30 mm 5 0326760000 AH 32 SAKG32 30 mm 5 0326760000 Cover / warning label Cover / warning label Marking systems AH 32 SAKG32 (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section SAK-Series TS 35 Special terminals - SAKG DEK 5/5 DEK 5/5 A.43 SAK-Series TS 35 Special terminals - SAKG A SAKG 32 III TS 35 / KrG 50 mm² SAKG 70 II G 70 mm² In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size V A mm² kV/- 32 x 94 x 84.5 192 / 70 10...70 32 x 84 x 51.4 192 / 95 10...95 IEC 60947-7-1 IEC 60947-7-1 IEC 1000 150 50 UL CSA 600 600 165 185 AWG 6...3/0 AWG 1...2/0 8/3 B11 / 5VA IEC 1000 192 70 ?r#a mm² mm² mm/- Note UL CSA 600 200 AWG 6...3/0 AWG 2/0...4/0 8/3 / 5VA ?ru#a Rated connection 10...16 / 10...70 10...70 / 10...70 6.0...12 Nm (M 8) 26 / Rated connection 10...16 6.0...12 Nm (M 8) A tightening torque of 12 Nm must be applied to 50 - 70 mm² stranded and AWG 2 - 3/0 7-core connections. Conductor connection with cable lugs according to DIN 46234 with 16..95 mm² and DIN 46235 with 10 .. 50 mm² Type Ordering data Version Medium yellow Order No. Type SAKG 32/35 III Qty. 10 0637220000 SAKG 70/35 II/GW Type Qty. Order No. Type Qty. Order No. 0636620000 10 Note Accessories Screwable cross-connection current Qty. 2-pole QL 2 SAKG32+70 150 A 5 0194000000 3-pole QL 3 SAKG32+70 150 A 5 0441500000 4-pole QL 4 SAKG32+70 150 A 5 0441600000 End plate / Partition plate Width dark brown Tropical applications dark brown Tropical applications Order No. Width EP 2 SAKG46/35 HP/DBR 2 mm 10 0180700000 EP 1 SAKG32/35 HP/DBR 2 mm 10 0180500000 EP 2 SAKG46/35 HP/TF/GE 2 mm 10 0180800000 EP 1 SAKG32/35 HP/TF/GE 2 mm 10 0180600000 TW SAKG46 HP/DBR/2 2 mm 10 0177100000 TW SAKG28 HP/DBR/2 2 mm 10 0151400000 TW SAKG46 HP/TF/GE/2 2 mm 10 0179900000 TW SAKG28 HP/TF/GE/2 2 mm 10 0164600000 30 mm 5 0326760000 AH 32 SAKG32 30 mm 5 0326760000 Cover / warning label Cover / warning label Marking systems (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.44 AH 32 SAKG32 DEK 5/5 DEK 5/5 SAKG 40 I 95 mm² SAKG 40 II 95 mm² SAKG 40 II GW 95 mm² SAK-Series TS 35 Special terminals - SAKG A 40 x 94 x 84.5 232 / 95 10...95 40 x 90 x 53 232 / 95 10...95 IEC 60947-7-1 IEC 60947-7-1 IEC 1000 232 95 UL CSA 600 600 195 250 AWG 2/0...4/0 AWG 2/0...4/0 8/3 B12 / 5VA IEC 1000 232 95 ?ru#a 40 x 90 x 53 232 / 95 10...95 IEC 60947-7-1 UL CSA 600 600 230 250 AWG 1...4/0 AWG 2/0...4/0 8/3 / 5VA IEC 1000 232 95 ?ru#a Rated connection 10...16 / 10...95 10...95 / 10...95 10...20 Nm (M 10) 25 / UL CSA 600 600 230 250 AWG 1...4/0 AWG 2/0...4/0 8/3 / 5VA ?ru#a Rated connection ...16 Rated connection ...16 10...20 Nm (M 10) 10...20 Nm (M 10) Conductor connection with cable lugs acc. to DIN 46234 from 10 .. 95 mm² Conductor connection with cable lugs according to DIN 46234, from 10 .. 95 mm² Conductor connection with cable lugs according to DIN 46234, from 10 .. 95 mm² Type Qty. SAKG 40/35 I Type 5 Order No. Type 0637520000 SAKG 40/35 II Qty. 5 Order No. Type 0637720000 SAKG 40/35 II/GW Qty. Order No. 0637820000 5 current Qty. Order No. Type current Qty. Order No. Type current Qty. QL 2 SAKG40/35 232 A 5 0211400000 QL 2 SAKG40/35 232 A 5 0211400000 QL 2 SAKG40/35 232 A 5 0211400000 QL 3 SAKG40/35 232 A 5 0444900000 QL 3 SAKG40/35 232 A 5 0444900000 QL 3 SAKG40/35 232 A 5 0444900000 QL 4 SAKG40/35 232 A 5 0445000000 QL 4 SAKG40/35 232 A 5 0445000000 QL 4 SAKG40/35 232 A 5 0445000000 Width Width Order No. Width EP 2 SAKG46/35 HP/DBR 2 mm 10 0180700000 EP 2 SAKG46/35 HP/DBR 2 mm 10 0180700000 EP 2 SAKG46/35 HP/DBR 2 mm 10 0180700000 EP 2 SAKG46/35 HP/TF/GE 2 mm 10 0180800000 EP 2 SAKG46/35 HP/TF/GE 2 mm 10 0180800000 EP 2 SAKG46/35 HP/TF/GE 2 mm 10 0180800000 TW SAKG46 HP/DBR/2 2 mm 10 0177100000 TW SAKG46 HP/DBR/2 2 mm 10 0177100000 TW SAKG46 HP/DBR/2 2 mm 10 0177100000 TW SAKG46 HP/TF/GE/2 2 mm 10 0179900000 TW SAKG46 HP/TF/GE/2 2 mm 10 0179900000 TW SAKG46 HP/TF/GE/2 2 mm 10 0179900000 38 mm 5 0326860000 AH 40 SAKG40 38 mm 5 0326860000 AH 40 SAKG40 38 mm 5 0326860000 AH 40 SAKG40 DEK 5/5 DEK 5/5 DEK 5/5 A.45 SAK-Series TS 35 Special terminals - SAKG A SAKG 40 III TS 35 / KrG 95 mm² SAKG 46 II 150 mm² In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size V A mm² kV/- 40 x 98 x 84.5 232 / 95 10...95 46 x 106 x 57 353 / 185 10...185 IEC 60947-7-1 IEC 60947-7-1 IEC 1000 232 95 UL CSA 600 600 195 230 AWG 1...4/0 AWG 2/0...4/0 8/3 B12 / 5VA IEC 1000 309 150 ?ru#a mm² mm² mm/- UL CSA 600 600 285 365 AWG 4/0...300 AWG 4...300 8/3 / 5VA ?ru#a Rated connection 10...16 / 10...95 10...95 / 10...95 16...20 Nm (M 10) 25 / Rated connection 10...16 14...31 Nm M 12 Note Conductor connection with cable lugs according to DIN 46234, from 10 .. 185 mm² and DIN 46235, from 25 .. 150 mm² Ordering data Version Type Medium yellow Qty. SAKG 40/35 III 5 Order No. Type 0637620000 SAKG 46/35 II Order No. Type Qty. Order No. 0637920000 5 Note Accessories Screwable cross-connection current Qty. 2-pole Type QL 2 SAKG46 309 A 5 0247000000 3-pole QL 3 SAKG46 309 A 5 0444400000 4-pole QL 4 SAKG46 309 A 5 0444500000 End plate / Partition plate Qty. Width dark brown Tropical applications dark brown Tropical applications Order No. Width EP 2 SAKG46/35 HP/DBR 2 mm 10 0180700000 EP 2 SAKG46/35 HP/DBR 2 mm 10 0180700000 EP 2 SAKG46/35 HP/TF/GE 2 mm 10 0180800000 EP 2 SAKG46/35 HP/TF/GE 2 mm 10 0180800000 TW SAKG46 HP/DBR/2 2 mm 10 0177100000 TW SAKG46 HP/DBR/2 2 mm 10 0177100000 TW SAKG46 HP/TF/GE/2 2 mm 10 0179900000 TW SAKG46 HP/TF/GE/2 2 mm 10 0179900000 38 mm 5 0326860000 AH 46 SAKG46 46 mm 5 0326960000 Cover / warning label Cover / warning label Marking systems (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.46 AH 40 SAKG40 DEK 5/5 DEK 5/5 SAKG 46 II GW 150 mm² SAKG 54 II 240 mm² SAKG 54 II GW 240 mm² SAK-Series TS 35 Special terminals - SAKG A 46 x 106 x 57 353 / 185 10...185 54 x 122 x 60.5 415 / 240 10...240 54 x 122 x 60.5 415 / 240 10...240 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 1000 309 150 IEC 1000 415 240 UL CSA 600 600 285 365 AWG 4/0...kcmil 300 AWG 1...300 8/3 / 5VA ?ru#a UL CSA 600 600 380 600 kcmil 300...kcmil 500 kcmil 300...kcmil 500 8/3 / 5VA IEC 1000 415 240 ?ru#a Rated connection 10...16 UL CSA 600 600 380 600 kcmil 300...kcmil 500 kcmil 300...kcmil 500 8/3 / 5VA ?ru#a Rated connection Rated connection 14...31 Nm M 12 25...60 Nm M 16 25...60 Nm M 16 Conductor connection with cable lugs according to DIN 46234, from 10 .. 185 mm² and DIN 46235, from 25 .. 150 mm² Conductor connection with cable lugs according to DIN 46234 and DIN 46235, from 70 .. 240 mm² Conductor connection with cable lugs according to DIN 46234 and DIN 46235, from 70 .. 240 mm² Type Qty. SAKG 46/35 II/GW Type 5 Order No. Type 0638020000 SAKG 54/35 II Qty. 5 Order No. Type 0638120000 SAKG 54/35 II/GW Qty. Order No. 0638220000 5 current Qty. Order No. Type current Qty. Order No. Type current Qty. QL 2 SAKG46 309 A 5 0247000000 QL 2 SAKG54 415 A 5 0264400000 QL 2 SAKG54 415 A 5 0264400000 QL 3 SAKG46 309 A 5 0444400000 QL 3 SAKG54 415 A 5 0408000000 QL 3 SAKG54 415 A 5 0408000000 QL 4 SAKG46 309 A 5 0444500000 QL 4 SAKG54 415 A 5 0247400000 QL 4 SAKG54 415 A 5 0247400000 Width Width Order No. Width EP 2 SAKG46/35 HP/DBR 2 mm 10 0180700000 EP 2 SAKG46/35 HP/DBR 2 mm 10 0180700000 EP 2 SAKG46/35 HP/DBR 2 mm 10 0180700000 EP 2 SAKG46/35 HP/TF/GE 2 mm 10 0180800000 EP 2 SAKG46/35 HP/TF/GE 2 mm 10 0180800000 EP 2 SAKG46/35 HP/TF/GE 2 mm 10 0180800000 TW SAKG46 HP/DBR/2 2 mm 10 0177100000 TW SAKG46 HP/DBR/2 2 mm 10 0177100000 TW SAKG46 HP/DBR/2 2 mm 10 0177100000 TW SAKG46 HP/TF/GE/2 2 mm 10 0179900000 TW SAKG46 HP/TF/GE/2 2 mm 10 0179900000 TW SAKG46 HP/TF/GE/2 2 mm 10 0179900000 46 mm 5 0326960000 AH 46 SAKG46 DEK 5/5 DEK 5/5 DEK 5/5 A.47 SAK-Series TS 35 Stud Terminal - KST A KST 5/35 TS 35 / PA 10 mm² KST 6/35 16 mm² In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range 24 x 62.5 x 49.5 57 / 24 x 60 x 54.5 76 / ... mm² Technical data Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals IEC 1000 57 10 V A mm² kV/- UL CSA 600 600 50 65 AWG 12...6 AWG 8...2 8/3 / V2 IEC 1000 76 16 # r#a Rated connection 2.0...4.0 Nm Tightening torque range (clamping screw) UL CSA 600 600 65 80 AWG 12...6 AWG 12...6 8/3 / V2 Rated connection 3.0...6.0 Nm Note Ordering data Version Type Qty. Order No. TS 35 x 7,5 TS 35 x 15/2,3 Type Qty. KST 6/35 M6X22 KST 5/35 M5X18 25 9528300000 Type Qty. Order No. Order No. 9506940000 25 Note Accessories Screwable cross-connection 2-pole QL 2 KST6 Partition plate Marking systems Width current Qty. 76 A 5 9501350000 Order No. Width left TW KST5-12 LI/NO 160/HM 10 1752800000 TW KST5-12 LI/NO 160/HM 10 1752800000 right TW KST5-12 RE/NO 160/HM 10 1718530000 TW KST5-12 RE/NO 160/HM 10 1718530000 (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.48 Type DEK 5/5 DEK 5/5 KST 8/35 35 mm² KST 10/35 70 mm² KST 12/35 95 mm² SAK-Series TS 35 Stud Terminal - KST A 24 x 62.5 x 72 125 / ... IEC 1000 125 35 34 x 60 x 82 192 / ... UL CSA 600 600 115 130 AWG 12...2 AWG 12...2 8/3 / V2 IEC 1000 232 70 r#a 34 x 60 x 74.5 232 / ... UL CSA 600 600 175 200 AWG 12...2/0 AWG 12...2/0 8/3 / V2 IEC 1000 232 95 r#a Rated connection 6.0...12 Nm # Rated connection Type Rated connection 14...31 Nm Order No. Type Order No. Type KST 8/35 M8X30 25 9506950000 KST 10/35 M10X39 20 9506960000 KST 12/35 M12X37 20 9506970000 KST 8/35 M8X30 25 9528320000 KST 10/35 M10X39 20 9528330000 KST 12/35 M12X37 20 9528340000 Type Qty. UL CSA 600 600 200 250 AWG 12...3 ...0000 8/3 / V2 current Qty. Order No. Type 125 A 5 9501360000 QL 2 KST10 TW KST5-12 LI/NO 160/HM 10 1752800000 TW KST5-12 RE/NO 160/HM 10 1718530000 QL 2 KST8 Order No. Type 5 9501370000 QL 2 KST12 TW KST5-12 LI/NO 160/HM 10 1752800000 TW KST5-12 RE/NO 160/HM 10 1718530000 Width DEK 5/5 Qty. current Qty. Order No. current Qty. 232 A 5 9501380000 TW KST5-12 LI/NO 160/HM 10 1752800000 TW KST5-12 RE/NO 160/HM 10 1718530000 Width DEK 5/5 Qty. Order No. Width DEK 5/5 A.49 SAK-Series TS 35 Terminals with electronic components A With electronic components TS 35 / PA DK 4 LD/1 4 mm² DC voltage indicator DK 4 LD/2 4 mm² DC voltage indicator In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Technical data 6 x 50 x 52.5 10 / 4 0.5...4 6 x 50 x 52.5 10 / 4 0.5...4 IEC 60947-7-1 Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Electronic fixtures Diode reverse voltage / Diode current Operating voltage for display, min. / Current Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size V A mm² kV/- IEC 24 10 4 IEC 60947-7-1 UL CSA IEC 24 10 4 1/3 A3 / V2 mm² mm² mm/- CSA 1/3 A3 / V2 r# V/mA UL r# 24 / 5 Rated connection 0.5...4 / 0.5...4 0.5...4 / 0.5...4 0.5...1.0 Nm (M 3) 9 / 0.6 x 3.5 mm 24 / 5 Rated connection 0.5...4 / 0.5...4 0.5...4 / 0.5...4 0.5...1.0 Nm (M 3) 9 / 0.6 x 3.5 mm Note Ordering data Version Type Qty. Order No. Type 0395460000 DK 4/35 LD GR 24VDC Qty. Order No. Red LED Green LED DK 4/35 LD GR 24VDC 25 25 0395760000 Neon lamp Note Accessories Screwable cross-connection current Qty. Order No. Type current Qty. 2-pole Type Q 2 AKZ4 32 A 50 0336400000 Q 2 AKZ4 32 A 50 0336400000 Order No. 3-pole Q 3 AKZ4 32 A 50 0336500000 Q 3 AKZ4 32 A 50 0336500000 4-pole Q 4 AKZ4 32 A 50 0336600000 Q 4 AKZ4 32 A 50 0336600000 2-pole QB 2 WI RA6 IS 27 A 50 0482700000 QB 2 WI RA6 IS 27 A 50 0482700000 3-pole QB 3 WI RA6 IS 27 A 50 0482800000 QB 3 WI RA6 IS 27 A 50 0482800000 4-pole QB 4 WI RA6 IS 27 A 50 0482900000 QB 4 WI RA6 IS 27 A 50 0482900000 Switchable link VL 2 AKZ4/DK4 50 0446700000 VL 2 AKZ4/DK4 50 0446700000 VH 10/4/2.8 AKZ4 50 0446600000 VH 10/4/2.8 AKZ4 50 0446600000 100 0266800000 BFSC M2.5X14 SAKD2.5N 100 0266800000 20 0180400000 50 0215700000 1.5 mm 20 0359260000 6 mm 100 0363360000 10-pole External cross-connection Switchable link Connecting sleeve Mounting screw BFSC M2.5X14 SAKD2.5N Testing / Checking Width Test plug Socket PS 2.3 RT Width 20 0180400000 PS 2.3 RT 50 0215700000 STB 8.5/D4/2.3/M2.5 AKZ 1.5 mm 20 0359260000 AP DK4 6 mm 100 0363360000 TSCH 4 AKZ4 5.4 mm STB 8.5/D4/2.3/M2.5 AKZ 5.4 mm End plate / Partition plate beige AP DK4 Small partition Small partition Marking systems (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.50 TSCH 4 AKZ4 DEK 5/6 DEK 5/6 DK 4 LD/3 4 mm² DC voltage indicator DK 4 LD/4 4 mm² DC voltage indicator DK 4 LD/5 4 mm² AC voltage indicator SAK-Series TS 35 Terminals with electronic components A 6 x 50 x 52.5 10 / 4 0.5...4 6 x 50 x 52.5 10 / 4 0.5...4 IEC 60947-7-1 IEC 24 10 4 6 x 50 x 52.5 10 / 4 0.5...4 IEC 60947-7-1 UL CSA IEC 24 10 4 IEC 60947-7-1 UL 1/3 A3 / V2 IEC 24 10 4 24 / 5 Rated connection 0.5...4 / 0.5...4 0.5...4 / 0.5...4 0.5...1.0 Nm (M 3) 9 / 0.6 x 3.5 mm # 24 / 5 Rated connection 0.5...4 / 0.5...4 0.5...4 / 0.5...4 0.5...1.0 Nm (M 3) 9 / 0.6 x 3.5 mm Qty. Order No. 24 / 5 Rated connection 0.5...4 / 0.5...4 0.5...4 / 0.5...4 0.5...1.0 Nm (M 3) 9 / 0.6 x 3.5 mm Type DK 4/35 LD ROT 24VDC 25 0210260000 DK 4/35 LD GR 24VDC 25 0210460000 DK 4/35 LD GR 24VDC CSA 1/3 A3 / V2 # Type UL 1/3 A3 / V2 # Type CSA Qty. Order No. Type Qty. DK 4/35 LD 1D ROT 24VAC 25 25 Order No. 0395960000 0210060000 current Qty. Order No. Type current Qty. Order No. Type current Qty. Q 2 AKZ4 32 A 50 0336400000 Q 2 AKZ4 32 A 50 0336400000 Q 2 AKZ4 32 A 50 0336400000 Q 3 AKZ4 32 A 50 0336500000 Q 3 AKZ4 32 A 50 0336500000 Q 3 AKZ4 32 A 50 0336500000 Q 4 AKZ4 32 A 50 0336600000 Q 4 AKZ4 32 A 50 0336600000 Q 4 AKZ4 32 A 50 0336600000 QB 2 WI RA6 IS 27 A 50 0482700000 QB 2 WI RA6 IS 27 A 50 0482700000 QB 2 WI RA6 IS 27 A 50 0482700000 QB 3 WI RA6 IS 27 A 50 0482800000 QB 3 WI RA6 IS 27 A 50 0482800000 QB 3 WI RA6 IS 27 A 50 0482800000 QB 4 WI RA6 IS 27 A 50 0482900000 QB 4 WI RA6 IS 27 A 50 0482900000 QB 4 WI RA6 IS 27 A 50 0482900000 VL 2 AKZ4/DK4 32 A 50 0446700000 VL 2 AKZ4/DK4 32 A 50 0446700000 VL 2 AKZ4/DK4 32 A 50 0446700000 50 0446600000 VH 10/4/2.8 AKZ4 50 0446600000 VH 10/4/2.8 AKZ4 50 0446600000 100 0266800000 BFSC M2.5X14 SAKD2.5N 100 0266800000 BFSC M2.5X14 SAKD2.5N 100 0266800000 20 0180400000 50 0215700000 1.5 mm 20 0359260000 6 mm 100 0363360000 VH 10/4/2.8 AKZ4 BFSC M2.5X14 SAKD2.5N Width PS 2.3 RT 20 0180400000 PS 2.3 RT 50 0215700000 STB 8.5/D4/2.3/M2.5 AKZ 1.5 mm 20 0359260000 AP DK4 6 mm 100 0363360000 TSCH 4 AKZ4 5.4 mm STB 8.5/D4/2.3/M2.5 AKZ AP DK4 TSCH 4 AKZ4 DEK 5/6 Width DEK 5/6 Width 20 0180400000 PS 2.3 RT 50 0215700000 STB 8.5/D4/2.3/M2.5 AKZ 1.5 mm 20 0359260000 AP DK4 6 mm 100 0363360000 TSCH 4 AKZ4 5.4 mm Order No. 5.4 mm DEK 5/6 A.51 SAK-Series TS 35 Terminals with electronic components A With electronic components TS 35 / PA DK 4 GL I 4 mm² Current indicator In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² 6 x 50 x 52.5 /4 0.33...4 Technical data Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Electronic fixtures Diode reverse voltage / Diode current Operating voltage for display, min. / Current Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size IEC 250 10 4 V A mm² kV/- UL CSA 1/3 A3 / V2 # V/A mm² mm² mm/- 3/1 Rated connection 0.5...4 / 0.5...4 0.5...4 / 0.5...4 0.5...1.0 Nm (M 3) 9 / 0.6 x 3.5 mm Note Ordering data Version Type Qty. Order No. Red LED Green LED Neon lamp DK 4/35 GL 1D I1,0A 25 1111160000 Note Accessories Screwable cross-connection current Qty. 2-pole Type Q 2 AKZ4 32 A 50 0336400000 Order No. 3-pole Q 3 AKZ4 32 A 50 0336500000 4-pole Q 4 AKZ4 32 A 50 0336600000 10-pole Q 10 AKZ4 32 A 20 0368600000 2-pole QB 2 WI RA6 IS 27 A 50 0482700000 3-pole QB 3 WI RA6 IS 27 A 50 0482800000 4-pole QB 4 WI RA6 IS 27 A 50 0482900000 Switchable link VL 2 AKZ4/DK4 32 A 50 0446700000 50 0446600000 100 0266800000 20 0180400000 50 0215700000 1.5 mm 20 0359260000 6 mm 100 0363360000 External cross-connection Switchable link Connecting sleeve Mounting screw VH 10/4/2.8 AKZ4 BFSC M2.5X14 SAKD2.5N Testing / Checking Width Test plug Socket PS 2.3 RT 5.4 mm STB 8.5/D4/2.3/M2.5 AKZ End plate / Partition plate beige AP DK4 Small partition Small partition Marking systems (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.52 TSCH 4 AKZ4 DEK 5/6 With electronic components TS 35 / PA DK 4 D/1 4 mm² Diode terminal, e.g. as reverse polarity protection DK 4 D/2 4 mm² Suppressor circuit for contactor and solenoid valve (DC voltage) A In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² 6 x 50 x 52.5 10 / 4 0.33...4 6 x 50 x 52.5 10 / 4 0.33...4 Technical data Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Electronic fixtures Diode reverse voltage / Diode current Operating voltage for display, min. / Current Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size IEC 380 10 4 V A mm² kV/- UL CSA 300 10 AWG 22...12 /3 A3 / V2 IEC 380 10 4 # A -/A mm² mm² mm/- Note UL CSA 300 10 AWG 22...12 /3 A3 / V2 r# 1000 / 1 1000 / 1 Rated connection 0.5...4 / 0.5...4 0.5...4 / 0.5...4 0.5...0.8 Nm (M 3) 9 / 0.6 x 3.5 mm Rated connection 0.5...4 / 0.5...4 0.5...4 / 0.5...4 0.5...0.8 Nm (M 3) 9 / 0.6 x 3.5 mm Diode current: max 1A. (1 N 4007) Diode current: max 1A. (1 N 4007) Ordering data Version Type Qty. Order No. DK 4/35 1D GET.SCH. 25 Type Qty. Order No. DK 4/35 1D A1 25 0538960000 0396360000 DK 4/35 1D A1 BL 25 0538980000 Red LED Green LED Note Accessories Screwable cross-connection current Qty. Order No. Type current Qty. 2-pole Type Q 2 AKZ4 32 A 50 0336400000 Q 2 AKZ4 32 A 50 0336400000 3-pole Q 3 AKZ4 32 A 50 0336500000 Q 3 AKZ4 32 A 50 0336500000 4-pole Q 4 AKZ4 32 A 50 0336600000 Q 4 AKZ4 32 A 50 Order No. 0336600000 2-pole QB 2 WI RA6 IS 27 A 50 0482700000 QB 2 WI RA6 IS 27 A 50 0482700000 3-pole QB 3 WI RA6 IS 27 A 50 0482800000 QB 3 WI RA6 IS 27 A 50 0482800000 4-pole QB 4 WI RA6 IS 27 A 50 0482900000 QB 4 WI RA6 IS 27 A 50 0482900000 Switchable link VL 2 AKZ4/DK4 32 A 50 0446700000 VL 2 AKZ4/DK4 50 0446700000 50 0446600000 VH 10/4/2.8 AKZ4 50 0446600000 100 0266800000 BFSC M2.5X14 SAKD2.5N 100 0266800000 20 0180400000 50 0215700000 1.5 mm 20 0359260000 6 mm 100 0363360000 External cross-connection Switchable link Connecting sleeve Mounting screw VH 10/4/2.8 AKZ4 BFSC M2.5X14 SAKD2.5N Testing / Checking Width Test plug Socket PS 2.3 RT Width 20 0180400000 PS 2.3 RT 50 0215700000 STB 8.5/D4/2.3/M2.5 AKZ 1.5 mm 20 0359260000 AP DK4 6 mm 100 0363360000 TSCH 4 AKZ4 5.4 mm STB 8.5/D4/2.3/M2.5 AKZ 5.4 mm End plate / Partition plate beige AP DK4 Small partition Small partition Marking systems TSCH 4 AKZ4 (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section SAK-Series TS 35 Terminals with electronic components DEK 5/6 DEK 5/6 A.53 SAK-Series TS 35 Terminals with electronic components A With electronic components TS 35 / PA DK 4 D/3 4 mm² Suppressor circuit for contactor and solenoid valve (DC voltage) DK 4 D/4 4 mm² Diode terminal for lamp test circuits In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² 6 x 50 x 52.5 10 / 4 0.33...4 6 x 50 x 52.5 10 / 4 0.33...4 Technical data Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Electronic fixtures Diode reverse voltage / Diode current Operating voltage for display, min. / Current Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size V A mm² kV/- IEC 380 10 4 UL CSA 300 10 IEC 380 10 4 /3 A3 / V2 mm² mm² mm/- Note CSA 300 10 /3 A3 / V2 r# A -/A UL # 1000 / 1 1000 / 1 Rated connection 0.5...4 / 0.5...4 0.5...4 / 0.5...4 0.5...0.8 Nm (M 3) 9 / 0.6 x 3.5 mm Rated connection 0.5...4 / 0.5...4 0.5...4 / 0.5...4 0.5...0.8 Nm (M 3) 9 / 0.6 x 3.5 mm Diode current: max 1A. (1 N 4007) Diode current: max 1A. (1 N 4007) Ordering data Version Type Red LED Qty. DK 4/35 1D A2 25 Order No. Type 0538860000 DK 4/35 2D GET.SCH. A1 Qty. 25 Order No. 0396660000 Green LED Note Accessories Screwable cross-connection current Qty. Order No. Type current Qty. 2-pole Type Q 2 AKZ4 32 A 50 0336400000 Q 2 AKZ4 32 A 50 0336400000 Order No. 3-pole Q 3 AKZ4 32 A 50 0336500000 Q 3 AKZ4 32 A 50 0336500000 4-pole Q 4 AKZ4 32 A 50 0336600000 Q 4 AKZ4 32 A 50 0336600000 2-pole QB 2 WI RA6 IS 27 A 50 0482700000 QB 2 WI RA6 IS 27 A 50 0482700000 3-pole QB 3 WI RA6 IS 27 A 50 0482800000 QB 3 WI RA6 IS 27 A 50 0482800000 4-pole QB 4 WI RA6 IS 27 A 50 0482900000 QB 4 WI RA6 IS 27 A 50 0482900000 Switchable link VL 2 AKZ4/DK4 50 0446700000 VL 2 AKZ4/DK4 32 A 50 0446700000 VH 10/4/2.8 AKZ4 50 0446600000 VH 10/4/2.8 AKZ4 50 0446600000 100 0266800000 BFSC M2.5X14 SAKD2.5N 100 0266800000 20 0180400000 50 0215700000 1.5 mm 20 0359260000 6 mm 100 0363360000 External cross-connection Switchable link Connecting sleeve Mounting screw BFSC M2.5X14 SAKD2.5N Testing / Checking Width Test plug Socket PS 2.3 RT Width 20 0180400000 PS 2.3 RT 50 0215700000 STB 8.5/D4/2.3/M2.5 AKZ 1.5 mm 20 0359260000 AP DK4 6 mm 100 0363360000 TSCH 4 AKZ4 5.4 mm STB 8.5/D4/2.3/M2.5 AKZ 5.4 mm End plate / Partition plate beige AP DK4 Small partition Small partition Marking systems (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.54 TSCH 4 AKZ4 DEK 5/6 DEK 5/6 DK 4 D/5 4 mm² Diode terminal for lamp test circuits DK 4 D/6 4 mm² Diode terminal for lamp test circuits DK 4 D/7 4 mm² Diode terminal for lamp test circuits, with protective resistor SAK-Series TS 35 Terminals with electronic components A 6 x 50 x 52.5 10 / 4 0.33...4 IEC 380 10 4 6 x 50 x 52.5 10 / 4 0.33...4 UL CSA 300 10 IEC 380 10 4 6 x 50 x 52.5 10 / 4 0.33...4 UL /3 A3 / V2 CSA 300 10 IEC 24 10 4 UL /3 A3 / V2 # CSA 300 10 /3 A3 / V2 # # 1000 / 1 1000 / 1 /1 Rated connection 0.5...4 / 0.5...4 0.5...4 / 0.5...4 0.5...0.8 Nm (M 3) 9 / 0.6 x 3.5 mm Rated connection 0.5...4 / 0.5...4 0.5...4 / 0.5...4 0.5...0.8 Nm (M 3) 9 / 0.6 x 3.5 mm Rated connection 0.5...4 / 0.5...4 0.5...4 / 0.5...4 0.5...0.8 Nm (M 3) 9 / 0.6 x 3.5 mm Diode current: max 1A. (1 N 4007) Diode current: max 1A. (1 N 4007) Diode current: max 1A. (1 N 4007) Type Qty. DK 4/35 2D GET.SCH. A2 Type 25 Order No. Type 0396860000 DK 4/35 2D GET.SCH. A1 Qty. 25 Order No. Type 0396760000 DK 4/35 1D 1K5 GET.SCH Qty. 25 Order No. 0396960000 current Qty. Order No. Type current Qty. Order No. Type current Qty. Q 2 AKZ4 32 A 50 0336400000 Q 2 AKZ4 32 A 50 0336400000 Q 2 AKZ4 32 A 50 0336400000 Q 3 AKZ4 32 A 50 0336500000 Q 3 AKZ4 32 A 50 0336500000 Q 3 AKZ4 32 A 50 0336500000 Q 4 AKZ4 32 A 50 0336600000 Q 4 AKZ4 32 A 50 0336600000 Q 4 AKZ4 32 A 50 0336600000 QB 2 WI RA6 IS 27 A 50 0482700000 QB 2 WI RA6 IS 27 A 50 0482700000 QB 2 WI RA6 IS 27 A 50 0482700000 QB 3 WI RA6 IS 27 A 50 0482800000 QB 3 WI RA6 IS 27 A 50 0482800000 QB 3 WI RA6 IS 27 A 50 0482800000 QB 4 WI RA6 IS 27 A 50 0482900000 QB 4 WI RA6 IS 27 A 50 0482900000 QB 4 WI RA6 IS 27 A 50 0482900000 VL 2 AKZ4/DK4 32 A 50 0446700000 VL 2 AKZ4/DK4 32 A 50 0446700000 VL 2 AKZ4/DK4 50 0446700000 50 0446600000 VH 10/4/2.8 AKZ4 50 0446600000 VH 10/4/2.8 AKZ4 50 0446600000 100 0266800000 BFSC M2.5X14 SAKD2.5N 100 0266800000 BFSC M2.5X14 SAKD2.5N 100 0266800000 20 0180400000 50 0215700000 1.5 mm 20 0359260000 6 mm 100 0363360000 VH 10/4/2.8 AKZ4 BFSC M2.5X14 SAKD2.5N Width PS 2.3 RT 20 0180400000 PS 2.3 RT 50 0215700000 STB 8.5/D4/2.3/M2.5 AKZ 1.5 mm 20 0359260000 AP DK4 6 mm 100 0363360000 TSCH 4 AKZ4 5.4 mm STB 8.5/D4/2.3/M2.5 AKZ AP DK4 TSCH 4 AKZ4 DEK 5/6 Width DEK 5/6 Width 20 0180400000 PS 2.3 RT 50 0215700000 STB 8.5/D4/2.3/M2.5 AKZ 1.5 mm 20 0359260000 AP DK4 6 mm 100 0363360000 TSCH 4 AKZ4 5.4 mm Order No. 5.4 mm DEK 5/6 A.55 SAK-Series TS 35 Terminals with electronic components A With electronic components TS 35 / PA DK 4 RC 4 mm² DK 4 PT 100 4 mm² Diode terminal for central control and communication system Terminal with RC combination In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² 18 x 50 x 52.5 /4 0.33...4 6 x 65 x 53.5 10 / 4 0.33...4 Technical data Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Electronic fixtures Diode reverse voltage / Diode current Operating voltage for display, min. / Current Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size IEC 230 10 4 V A mm² kV/- UL CSA IEC 400 10 4 UL CSA /3 A3 / V2 # # -/A mm² mm² mm/- Rated connection 0.5...4 / 0.5...4 0.5...4 / 0.5...4 0.5...0.8 Nm (M 3) 9 / 0.6 x 3.5 mm Rated connection 0.5...4 / 0.5...4 0.5...4 / 0.5...2.5 0.4...0.7 Nm (M 2.5) 6 / 0.6 x 3.5 mm Note Ordering data Version Type Red LED Qty. DK 4/35 RC 220R/220N 5 Order No. Type 0053160000 DKT 4/35 PT100 Qty. 10 Order No. 8014720000 Note Accessories Screwable cross-connection current Qty. Order No. Type current Qty. 2-pole Type Q 2 AKZ4 32 A 50 0336400000 Q 2 AKZ4 32 A 50 0336400000 Order No. 3-pole Q 3 AKZ4 32 A 50 0336500000 Q 3 AKZ4 32 A 50 0336500000 4-pole Q 4 AKZ4 32 A 50 0336600000 Q 4 AKZ4 32 A 50 0336600000 10-pole Q 10 AKZ4 32 A 20 0368600000 2-pole QB 2 WI RA6 IS 27 A 50 0482700000 3-pole QB 3 WI RA6 IS 27 A 50 0482800000 4-pole QB 4 WI RA6 IS 27 A 50 0482900000 20 0180400000 50 0215700000 20 0687560000 External cross-connection Switchable link Switchable link Connecting sleeve Mounting screw VL 2 AKZ4/DK4 32 A VH 10/4/2.8 AKZ4 BFSC M2.5X14 SAKD2.5N Testing / Checking 50 0446700000 50 0446600000 100 0266800000 20 0180400000 PS 2.3 RT 50 0215700000 STB 8.5/D4/2.3/M2.5 AKZ AP DKT4 PA Width Test plug Socket PS 2.3 RT 5.4 mm STB 8.5/D4/2.3/M2.5 AKZ Width 5.4 mm End plate / Partition plate beige AP DK4 1.5 mm 20 0359260000 EW 35 8.5 mm 50 0383560000 End bracket Dark beige Wemid Marking systems (see assortment in catalogue 7) Marking tags For detailed information on other accessories and applications, refer to the „Accessories“ section A.56 DEK 6 End plate AP DK4: 0359260000 DEK 5/6 1.5 mm SAKT E/35 SAK-Series TS 35 Earth conductor isolating terminals 6 mm² neon lamp A In hazardous area applications, the installation instructions and the rated data specifications for accessories given in the technical appendix must be followed. Width/Length/height with TS35x7.5 mm max. current / max. cond. cross-section A/mm² Max. clamping range mm² Operating mode 16 x 65 x 52.5 27 / 10 0.5...10 SAKT E Technical data Rated data Rated voltage Rated current Rated cross-section Rated impulse voltage / Pollution severity Gauge to IEC 60947-1 / UL94 Flammability class Approvals Clamped conductors (H05V/H07V) solid / stranded flexible / Stranded wire with end ferrules Tightening torque range (clamping screw) Stripping length / Blade size V A mm² kV/- mm² mm² mm/- IEC 115 27 6 UL CSA /3 A5 / 5VA • Slide link is closed • Auxiliary circuit is earthed Rated connection 0.5...10 0.5...6 / 0.5...6 0.8...1.6 Nm (M 3.5) 12 / 4.0 x 0.8 mm • Display is illuminated green Test position When measuring insulation resistance with voltages greater than UNom, the earth connection must first be disconnected. Note Ordering data Version Type Qty. Order No. 20...30 V~ SAKT E/35 2LD 30VAC 5 1166820000 40...60V~ SAKT E/35 2LD 60VAC 5 0197920000 80...120 V~ SAKT E/35 2LD 120VAC 5 0198220000 115 V~ SAKT E/35 2GL 115VAC 5 0198020000 230 V~ SAKT E/35 2GL 230VAC 5 0198120000 SAKT E Note Accessories • Slide link is opened End bracket Type Dark beige Wemid EW 35 Width Qty. 8.5 mm 50 Order No. • Auxiliary circuit is not earthed 0383560000 • No earth fault • Display illuminated green and red with reduced intensity • Disconnected earth connection -> When measuring insulation resistance with voltages greater than UNom, the earth connection must be disconnected. Operational malfunction SAKT E • Slide link is opened • Auxiliary circuit is not earthed • Earth fault • Display is illuminated red (see assortment in catalogue 7) For detailed information on other accessories and applications, refer to the „Accessories“ section To safe the test sockets use the SD-blade or bits with pilots! A.57 A A.58 SAK-Series TS 35