View detail for ATF750C Reliability Qualification Report

PAGE 1 OF 6
ATMEL CORPORATION
Tel:(408)441-0311
Fax:(408)436-4200
AT-F750C(L) FLASH RELIABILITY DATA
- 150°C RETENTION BAKE
- 125°C DYNAMIC OPERATING LIFETEST
- EXTENDED TEMPERATURE CYCLE
- 131°C/85% RELATIVE HUMIDITY HAST TEST
- 121°/15PSI PRESSURE POT TEST
OCTOBER 2007
2325 Orchard Parkway San Jose CA. 95131
PAGE 2 OF 6
AT-F750C(L)
150°C RETENTION BAKE
LOT
NUMBER
DATE
CODE
SAMPLE
SIZE
8B2923
8B2921-2
9A3233-1
9D2672-2
1B0285-1
1B0288-1
1B3016
1B0285-2
4E2170
6H0919-4
6H0919-5
6H5308-1
7F2232-1
8B9909
8B9834
9A9921
9D0033
1B0123
1B0145
1B0251
1B0334
4E0510
6H0646
6H0646
6H0651
7F0725
300
50
50
60
395
50
150
50
50
80
77
80
80
TOTAL NUMBER
HOURS (K)
300.0
50.0
50.0
60.0
395.0
50.0
150.0
50.0
50.0
80.0
77.0
80.0
80.0
NUMBER OF
FAILURES
0
0
0
0
0
0
0
0
0
0
0
0
0
FAILURE RATE
TOTAL DEVICE HOURS
BEST ESTIMATE
1,392,000 DEVICE HOURS
λ
50°C AMBIENT
CONFIDENCE ESTIMATE
= 0.05% PER 1,000 HOURS
EXTRAPOLATION TO 50°C VIA
ARRHENNIUS EQUATION AND
ACTIVATION ENERGY OF 0.5eV
λ
= 0.0007% PER 1,000 HOURS
(7 FITS)
λ
λ
60 = 0.001% PER 1,000 HOURS
60% CONFIDENCE (9 FITS)
90 = 0.002% PER 1,000 HOURS
90% CONFIDENCE (24 FITS)
PAGE 3 OF 6
AT-F750C(L)
125°C DYNAMIC OPERATING LIFETEST
LOT
NUMBER
DATE
CODE
SAMPLE
SIZE
TOTAL NUMBER
HOURS (K)
NUMBER OF
FAILURES
9A3233-1
9A9921
100
100.0
0
9B0424A
9B9946
120
120.0
0
9D2672-2
9D0033
100
100.0
0
1B0285-1
1B0123
100
100.0
0
1B0288-1
1B0145
100
100.0
0
1B3016
1B0251
150
150.0
0
1B0285-2
1B0334
100
100.0
0
4E2170
4E0510
100
100.0
0
6H0919-5
6H0646
100
100.0
0
6H5308-1
6H0651
80
80.0
0
7F2232-1
7F0725
80
80.0
0
FAILURE RATE
1,130,000 DEVICE HOURS
TOTAL DEVICE HOURS
BEST ESTIMATE
λ
= 0.06% PER 1,000 HOURS
λ
EXTRAPOLATION TO 50°C VIA
ARRHENNIUS EQUATION AND
ACTIVATION ENERGY OF 0.5eV
= 0.002% PER 1,000 HOURS (21 FITS)
50°C AMBIENT
CONFIDENCE ESTIMATE
λ
λ
60 = 0.003% PER 1,000 HOURS
60% CONFIDENCE (28 FITS)
90 = 0.007% PER 1,000 HOURS
90% CONFIDENCE (69 FITS)
PAGE 4 OF 6
AT-F750C(L)
EXTENDED TEMPERATURE CYCLE
-65°C to +150°C PLCC/TSOP/SOIC/PDIP
-55°C to +125°C CBGA
DATE
CODE
PACKAGE
TYPE
SAMPLE
SIZE
NUMBER OF
CYCLES
NUMBER OF
FAILURES
9A9921
24 PDIP
50
1000
0
9D0033
24 PDIP
50
1000
0
1B0123
24 PDIP
50
1000
0
1B0145
24 PDIP
50
1000
0
1B0251
24 SOIC
50
1000
0
1B0334
24 PDIP
50
1000
0
4E0432
24 PDIP
80
1000
0
4E0510
24 PDIP
50
1000
0
6H0646
24 PDIP
50
1000
0
PAGE 5 OF 6
AT-F750C(L)
131°C/85% RELATIVE HUMIDITY HAST TEST
LOT
NUMBER
DATE
CODE
PACKAGE
TYPE
SAMPLE
SIZE
NUMBER OF FAILURES
AT INDICATED HOURS
(100)
9A3233-1
9A9921
24 PDIP
50
0
9D2672-2
9D0033
24 PDIP
50
0
1B0285-1
1B0123
24 PDIP
50
0
1B0288-1
1B0145
24 PDIP
50
0
1B3016
1B0251
24 SOIC
50
0
1B0285-2
1B0334
24 PDIP
50
0
4E2170
4E0510
24 PDIP
50
0
6H0919-5
6H0646
24 PDIP
77
0
PAGE 6 OF 6
AT-F750C(L)
121°C/15PSI PRESSURE POT TEST
DATE
CODE
PACKAGE
TYPE
SAMPLE
SIZE
NUMBER OF FAILURES
AT INDICATED HOURS
(24) (48) (72) (96)
9A9921
24 PDIP
50
0
0
0
0
9D0033
24 PDIP
50
0
0
0
0
1B0123
24 PDIP
50
0
0
0
0
1B0145
24 PDIP
77
0
0
0
0
1B0251
24 SOIC
50
0
0
0
0
1B0334
24 PDIP
50
0
0
0
0
4E0510
24 PDIP
50
0
0
0
0
6H0646
24 PDIP
77
0
0
0
0