View detail for AT90S8515 Reliability Qualification Report

PAGE 1 OF 7
ATMEL CORPORATION
Tel: (408) 441-0311
Fax: (408) 436-4200
AT-90S8515 AVR MICROCONTROLLER RELIABILITY DATA
- 125°C RETENTION BAKE (PLASTIC)
- 125°C DYNAMIC OPERATING LIFE TEST (PLASTIC)
- 15 PSIG PRESSURE POT
- EXTENDED TEMPERATURE CYCLE
- 85°C/85% RELATIVE HUMIDITY OPERATING LIFETEST
- 131°C/85% RELATIVE HUMIDITY HAST TEST
JULY 2003
2325 Orchard Parkway San Jose CA. 95131
PAGE 2 OF 7
AT-90S8515
PLASTIC PACKAGE
125°C DYNAMIC OPERATING LIFE TEST
LOT
NUMBER
DATE
CODE
SAMPLE
SIZE
TOTAL
CKT-HRS(K)
NUMBER
OF FAILURES
7C3418
7C9749
100
100.0
0
0C2060
0C0031
100
100.0
0
1J3059A-1
1J0210
100
100.0
0
FAILURE RATE
TOAL DEVICE HOURS
BEST ESTIMATE
300,000 DEVICE HOURS
λ
= 0.2% PER 1,000 HOURS
λ
EXTRAPOLATION TO 50°C.VIA ARREHENNIUS
EQUATION AND ACTIVATION ENERGY OF 0.5eV
= 0.008% PER 1,000 HOURS (78 FITS)
50°C AMBIENT
CONFIDENCE ESTIMATE
λ
λ
60 = 0.01% PER
60% CONFIDENCE
90 = 0.03% PER
90% CONFIDENCE
1,000 HOURS
(104 FITS)
1,000 HOURS
(260 FITS)
PAGE 3 OF 7
AT-90S8515
PLASTIC PACKAGE
150°C RETENTION BAKE
LOT
NUMBER
DATE
CODE
SAMPLE
SIZE
24
HOURS TO FAILURES
168
500
1000
7C3418
7C9749
100
0
0
0
0
0C2060
0C0031
50
0
0
0
0
1J3059A-1
1J0210
50
0
0
0
0
FAILURE RATE
TOTAL DEVICE HOURS
BEST ESTIMATE
200,000 DEVICE HOURS
λ
= 0.3% PER 1000 HOURS
λ
EXTRAPOLATION TO 50°C VIA ARRHENNIUS
EQUATION AND ACTIVATION ENERGY OF 0.5eV
= 0.005% PER 1,000 HOURS (56 FITS)
50°C AMBIENT
CONFIDENCE ESTIMATE
λ
λ
60 = 0.007% PER 1000 HOURS
60% CONFIDENCE (66 FITS)
90 = 0.01% PER 1000 HOURS
90% CONFIDENCE (165 FITS)
PAGE 4 OF 7
AT-90S8515
PLASTIC PACKAGE
PRESSURE POT TEST
DATE
CODE
PACKAGE
TYPE
SAMPLE
SIZE
NUMBER OF FAILURES
AT INDICATED HOURS
(24)
7C9749
40 PDIP
50
(48)
0
(72)
0
(96)
0
0
0C0031
40 PDIP
50
0
0
0
0
1J0210
40 PDIP
50
0
0
0
0
PAGE 5 OF 7
AT-90S8515
PLASTIC PACKAGE
EXTENDED TEMPERATURE CYCLING
-65°C to +150°C PLCC/TSOP/SOIC/PDIP
-55°C to +125°C CBGA
DATE
CODE
PACKAGE
TYPE
SAMPLE
SIZE
77
NUMBER
OF CYCLES
NUMBER
OF FAILURES
7C9749
40 PDIP
1000
0
0C0031
40 PDIP
50
1000
0
1J0210
40 PDIP
50
1000
0
PAGE 6 OF 7
AT-90S8515
PLASTIC PACKAGE
85°C/85% RELATIVE HUMIDITY OPERATING LIFETEST
LOT
NUMBER
DATE
CODE
7C3418
7C9749
SAMPLE
SIZE
50
HOURS TO FAILURES
168
500
1000
0
0
0
PAGE 7 OF 7
AT-90S8515
PLASTIC PACKAGE
131°C/85% RELATIVE HUMIDITY HAST TEST
LOT
NUMBER
DATE
CODE
PACKAGE
TYPE
SAMPLE
SIZE
NUMBER OF FAILURES
AT INDICATED HOURS
(100)
0C2060
1J3059A-1
0C0031
40 PDIP
50
0
1J0210
40 PDIP
50 0