PAGE 1 OF 2 ATMEL CORPORATION Tel:(408)441-0311 Fax:(408)436-4200 AT-V750B EPLD RELIABILITY DATA* -125C OPERATING LIFE TEST * This report was generated from ATV750 reliability testing. This data is applicable to the following device types due to same technology grouping as defined in MIL-M-38535 Appendix A: AT-22V10B AT-V2500 OCTOBER 2008 2325 Orchard Parkway San Jose CA. 95131 PAGE 2 OF 2 AT-V750B 125C DYNAMIC OPERATING LIFE TEST LOT NUMBER DATE CODE SAMPLE SIZE TOTAL CKT-HRS(K) NUMBER OF FAILURES 3D0810 3B9343 79 79.0 0 4A0595 4A9425 433 1082.5 0 4D1499 4D9533 160 400.0 0 8A2319C 8A0813 80 80.0 0 FAILURE RATE TOTAL DEVICE HOURS BEST ESTIMATE 1,641,500 DEVICE HOURS = 0.04% PER 1,000 HOURS EXTRAPOLATION TO 50C VIA ARRHENNIUS EQUATION AND ACTIVATION ENERGY OF 0.5eV = 0.002% PER 1,000 HOURS (14 FITS) 50C AMBIENT CONFIDENCE ESTIMATE 60 = 0.002% PER 1,000 HOURS 60% CONFIDENCE (19 FITS) 90 = 0.005% PER 1,000 HOURS 90% CONFIDENCE (48 FITS)