View detail for ATMEGA163 Reliability Qualification Report

PAGE 1 OF 6
ATMEL CORPORATION
Tel:(408)441-0311
Fax:(408)436-4200
AT-MEGA163 RELIABILITY DATA
- 150°C RETENTION BAKE (PLASTIC)
- 125°C DYNAMIC LIFETEST (PLASTIC)
- 131°C/85% RELATIVE HUMIDITY HAST TEST
- EXTENDED TEMPERATURE CYCLE
- 121°C/15PSG PRESSURE POT TEST
JULY 2003
2325 Orchard Parkway San Jose CA. 95131
PAGE 2 OF 6
AT-MEGA163
PLASTIC PACKAGE
150°C RETENTION BAKE
LOT
NUMBER
DATE
CODE
SAMPLE
SIZE
TOTAL CKT
HOURS (K)
NUMBER OF
FAILURES
0H0056
0H0035
300
300.0
0
0H0059
0H0035
300
300.0
0
0H0061
0H0035
300
300.0
0
0J1744
0J0102
50
50.0
0
FAILURE RATE
TOTAL DEVICE HOURS
BEST ESTIMATE
950,000 DEVICE HOURS
λ
= 0.07% PER 1,000 HOURS
λ
EXTRAPOLATION TO 50°C VIA ARRHENNIUS
EQUATION AND ACTIVATION ENERGY OF 0.5eV
= 0.001% PER 1,000 HOURS (11 FITS)
50°C AMBIENT
CONFIDENCE ESTIMATE
λ
λ
60 = 0.001% PER 1,000 HOURS
60% CONFIDENCE (14 FITS)
90 = 0.004% PER 1,000 HOURS
90% CONFIDENCE (35 FITS)
PAGE 3 OF 6
AT-MEGA163
PLASTIC PACKAGE
125°C DYNAMIC LIFETEST
LOT
NUMBER
DATE
CODE
SAMPLE
SIZE
NUMBER OF FAILURES
AT INDICATED HOURS
(168)
(500) (1000)
0H0056
0H0035
100
0
0
0
0H0059
0H0035
78
0
0
0
0J1744
0J0102
100
0
0
0
FAILURE RATE
TOTAL DEVICE HOURS
BEST ESTIMATE
278,000 DEVICE HOURS
λ
= 0.4% PER 1,000 HOURS
λ
EXTRAPOLATION TO 50°C VIA ARRHENNIUS
EQUATION AND ACTIVATION ENERGY OF 0.5eV
= 0.004% PER 1,000 HOURS (36 FITS)
50°C AMBIENT
CONFIDENCE ESTIMATE
λ
λ
60 = 0.005% PER 1,000 HOURS
60% CONFIDENCE (47FITS)
90 = 0.01% PER 1,000 HOURS
90% CONFIDENCE (119 FITS)
PAGE 4 OF 6
AT-MEGA163
PLASTIC PACKAGE
131°C/85% RELATIVE HUMIDITY HAST TEST
LOT
NUMBER
DATE
CODE
PACKAGE
TYPE
SAMPLE
SIZE
NUMBER OF FAILURES
AT INDICATED HOURS
(100)
0J1744
OJ0102
44 TQFP
50
0
PAGE 5 OF 6
AT-MEGA163
PLASTIC PACKAGE
EXTENDED TEMPERATURE CYCLE
-65°C to +150°C TSOP/PLCC/SOIC/PDIP
-55°C to +125°C CBGA
DATE
CODE
PACKAGE
TYPE
SAMPLE
SIZE
NUMBER OF
CYCLES
NUMBER OF
FAILURES
0J0102
44 TQFP
50
1000
0
2H0316
44 TQFP
50
1000
0
PAGE 6 OF 6
AT-MEGA163
PLASTIC PACKAGE
121°C/15PSG PRESSURE POT TEST
DATE
CODE
PACKAGE
TYPE
SAMPLE
SIZE
NUMBER OF FAILURES
AT INDICATED HOURS
(24) (48) (72) (96)
0J0102
44 TQFP
46
0
0
0
0
2H0316
44 TQFP
50
0
0
0
0