View detail for AT90S2313 Reliability Qualification Report

PAGE 1 OF 6
ATMEL CORPORATION
Tel:(408)441-0311
Fax:(408)436-4200
AT-90S2313 FLASH RELIABILITY DATA
- 150°C RETENTION BAKE (PLASTIC)
- EXTENDED TEMPERATURE CYCLE
- 121°C/15PSG PRESSURE POT TEST
- 125°C DYNAMIC LIFETEST (PLASTIC)
- 131°/85% RELATIVE HUMIDITY HAST TEST
OCTOBER 2004
2325 Orchard Parkway San Jose CA. 95131
PAGE 2 OF 6
AT-90S2313
PLASTIC PACKAGE
150°C RETENTION BAKE
LOT
NUMBER
DATE
CODE
SAMPLE
SIZE
TOTAL
CKT-HRS(K)
NUMBER OF FAILURES
AT INDICATED HOURS
(168)(500) (1000)
8C2332-1
8C9848
50
50.0
0
0
0
0C0801C
0C0039
50
50.0
0
0
0
2H4432-2
2H0248
300
300.0
0
0
0
2H3800-2
2H0302
300
300.0
0
0
0
3H4890
3H0412
200
200.0
0
0
0
FAILURE RATE
TOTAL DEVICE HOURS
BEST ESTIMATE
900,000 DEVICE HOURS
λ
= 0.08% PER 1,000 HOURS
λ
λ
EXTRAPOLATION TO 50°C VIA
ARRHENNIUS EQUATION AND
ACTIVATION ENERGY OF 0.5eV
= 0.001% PER 1,000 HOURS (11 FITS)
60 = 0.002% PER 1,000 HOURS
60% CONFIDENCE (15 FITS)
90 = 0.004% PER 1,000 HOURS
90% CONFIDENCE (37 FITS)
50°C AMBIENT
1CONFIDENCE ESTIMATE
λ
PAGE 3 OF 6
AT-90S2313
PLASTIC PACKAGE
EXTENDED TEMPERATURE CYCLE
-65°C to +150°C PLCC/TSOP/SOIC/PDIP
-55°C to +125°C CBGA
DATE
CODE
PACKAGE
TYPE
SAMPLE
SIZE
NUMBER
OF CYCLES
NUMBER
OF FAILURES
8C9848
20 SOIC
50
1000
0
0C0039
20 SOIC
50
1000
0
2H0248
20 PDIP
50
1000
0
2H0302
20 SOIC
50
1000
0
3H0412
20 SOIC
77
1000
0
PAGE 4 OF 6
AT-90S2313
PLASTIC PACKAGE
121°C/15PSG PRESSURE POT TEST
DATE
CODE
PACKAGE
TYPE
SAMPLE
SIZE
NUMBER OF FAILS
AT INDICATED HOURS
(24) (48) (72) (96)
8C9848
20 SOIC
50
0
0
0
0
0C0039
20 SOIC
50
0
0
0
0
2H0248
20 PDIP
50
0
0
0
0
2H0302
20 SOIC
50
0
0
0
0
3H0412
20 SOIC
77
0
0
0
0
PAGE 5 OF 6
AT-90S2313
PLASTIC PACKAGE
125°C DYNAMIC LIFETEST
LOT
NUMBER
DATE
CODE
SAMPLE
SIZE
TOTAL
CKT HRS(K)
NUMBER OF
FAILURES
0C0801C
0C0039
100
100.0
0
2H4432-2
2H0248
100
100.0
0
2H3800-2
2H0302
150
150.0
0
3H4890
3H0412
100
100.0
0
FAILURE RATE
TOTAL DEVICE HOURS
BEST ESTIMATE
450,000 DEVICE HOURS
λ
50°C AMBIENT
λ
CONFIDENCE ESTIMATE
λ
λ
= 0.1% PER 1,000 HOURS
EXTRAPOLATION TO 50°C VIA
ARRHENNIUS EQUATION AND
ACTIVATION ENERGY OF 0.5eV
= 0.005% PER 1,000 HOURS (52 FITS)
60 = 0.007% PER 1,000 HOURS
60% CONFIDENCE (69 FITS)
90 = 0.01% PER 1,000 HOURS
90% CONFIDENCE (173 FITS)
PAGE 6 OF 6
AT-90S2313
PLASTIC PACKAGE
131°C/85% RELATIVE HUMIDITY HAST TEST
DATE
CODE
PACKAGE
TYPE
SAMPLE
SIZE
NUMBER OF FAILURES
AT INDICATED HOURS
(100)
0C0039
20 SOIC
50
0
2H0248
20 PDIP
50
0
2H0302
20 SOIC
50
0
3H0412
20 SOIC
77
0