FF-1319-13H

FF-1319-13H
This filter has been designed to operate with the Vicor
"VI- HAMD / BAMD harmonic attenuator modules" to
meet EN55022, class B.
This model is identical to the (-13) except for the form
factor of the enclosure.
Order P/N:
LINE
LOAD
BLUE
BLUE
BROWN
BROWN
FF-1319-13H
GRN / YEL
Operating Voltage = _________________DC to 250 Vac
Operating Current (Max) = ____________________ 13A
Operating Frequency = ___________________50/60 Hz
INSERTION LOSS vs. FREQUENCY
Temp. Range (Storage) = ______________-40 to 85°C
Temp. Range (Operating) (-13C) @ 13.0 A = -40 to 65ºC
Diel. Withstanding Voltage (Ph - Case) = ____ 1500 Vac
Diel. Withstanding Voltage (Ph - Ph) = ______1500 Vdc
Leakage Current @ 250 Vac, 60 HZ = _____2.5 mA Max
Discharge Voltage after 60 sec = ___________34 V Max
Calculated MTBF = __________________2,278,891 Hrs
USA
JMK Inc 15 Caldwell Dr. Amherst, NH 03031
PH: 603 886-4100
FX: 603 886-4115
email: [email protected]
PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884
EUR
JMK Inc Glasgow G13 1DN Scotland UK