LL-1319-13M Operating Voltage = DC to 250 Vac Operating Current (Max)= 13A Frequency = 50/60 HZ Temp. Range (Storage) = -40 to 85 C Temp Range (Operating) @ 12.6 A = -20 to 45 C Diel. Withstanding Voltage (Ph - Case) = 1500 Vac Diel Withstanding Voltage (Ph - Ph) = 1500 Vdc Leakage current @ 250 Vac, 60 HZ = 2.5 MA max. Discharge Voltage after 60 sec = 34 V max. Order P/N LL-1319-13M See page 2 for performance graph and other information on this filter. USA EUR JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115 email: [email protected] JMK Ltd Glasgow G13 1DN Scotland UK PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884 LL-1319-13M 90 80 When mated with the Vicor Harmonic Attenuator Module Driver and Harmonic Attenuator Module Booster (Part# VI-HAMD-IM, VI-BAMD-IM), the LL-1319-13M EMI filter is designed to meet the Conducted Emissions and Conducted Susceptibility requirements of MIL-STD-461E at the input connections for the following platforms: Surface Ships, Navy Aircraft and Army Ground. INSERTION LOSS (db) 70 CM 60 50 DM 40 30 20 10 0 .01 .04 .02 .1 .07 .4 .2 1 .7 4 2 10 7 40 20 100 70 FREQUENCY (MEGAHERTZ) Other Parameters: Thermal Shock MIL-STD-202, Method 107, Test Condition A, except Step 1 shall be –40 o C +0, -3 Mechanical Shock MIL-STD-202, Method 213B, Test Condition K Vibration MIL-STD-202, Method 204D, Test Condition B Moisture Resistance MIL-STD-202, Method 106G Seal MIL-STD-202, Test Condition D USA EUR JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115 email: [email protected] JMK Ltd Glasgow G13 1DN Scotland UK PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884