JMK LL-1319-13M

LL-1319-13M
Operating Voltage = DC to 250 Vac
Operating Current (Max)= 13A
Frequency = 50/60 HZ
Temp. Range (Storage) = -40 to 85 C
Temp Range (Operating) @ 12.6 A = -20 to 45 C
Diel. Withstanding Voltage (Ph - Case) = 1500 Vac
Diel Withstanding Voltage (Ph - Ph) = 1500 Vdc
Leakage current @ 250 Vac, 60 HZ = 2.5 MA max.
Discharge Voltage after 60 sec = 34 V max.
Order P/N LL-1319-13M
See page 2 for performance graph and other information on this filter.
USA
EUR
JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100
FX: 603 886-4115
email: [email protected]
JMK Ltd Glasgow G13 1DN Scotland UK PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884
LL-1319-13M
90
80
When mated with the Vicor Harmonic Attenuator Module
Driver and Harmonic Attenuator Module Booster
(Part# VI-HAMD-IM, VI-BAMD-IM), the LL-1319-13M
EMI filter is designed to meet the Conducted Emissions and
Conducted Susceptibility requirements of MIL-STD-461E at
the input connections for the following
platforms: Surface Ships, Navy Aircraft and Army Ground.
INSERTION LOSS (db)
70
CM
60
50
DM
40
30
20
10
0
.01
.04
.02
.1
.07
.4
.2
1
.7
4
2
10
7
40
20
100
70
FREQUENCY (MEGAHERTZ)
Other Parameters:
Thermal Shock MIL-STD-202, Method 107, Test Condition A, except Step 1 shall be –40 o C +0, -3
Mechanical Shock MIL-STD-202, Method 213B, Test Condition K
Vibration MIL-STD-202, Method 204D, Test Condition B
Moisture Resistance MIL-STD-202, Method 106G
Seal MIL-STD-202, Test Condition D
USA
EUR
JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100
FX: 603 886-4115
email: [email protected]
JMK Ltd Glasgow G13 1DN Scotland UK PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884