JMK Inc. This filter has been designed to operate with the Vicor "VI- HAMD / BAMD harmonic attenuator modules" to meet EN55022, class B. The filter will also function very well with most other switching regulators Order P/N: FF-1319-13 Unit Shipping weight: 2.4 lbs (1.09 Kg) FF-1319-13 Operating Voltage = DC to 250 Vac Operating Current (Max)= 13A Frequency = 50/60 HZ Temp. Range (Storage) = -40 to 100 C Temp Range (Operating) @ 13.0 A = -20 to 40 C Diel. Withstanding Voltage (Ph - Case) = 1500 Vac Diel Withstanding Voltage (Ph - Ph) = 1500 Vdc Leakage current @ 250 Vac, 60 HZ = 2.5 MA max. Discharge Voltage after 60 sec = 34 V max. 90 LINE LOAD BLUE BLUE 80 70 CM BROWN BROWN INSERTION LOSS (db) 60 50 DM 40 30 20 GRN / YEL 10 0 .01 .04 .02 .1 .07 .4 .2 1 .7 4 2 10 7 40 20 FREQUENCY (MEGAHERTZ) USA JMK Inc 15 Caldwell Dr. Amherst, NH 03031 EUR JMK Inc Glasgow G13 1DN Scotland UK PH: 603 886-4100 FX: 603 886-4115 email: [email protected] PH: 44-(0) 7785310729 FX: 44-(0) 141-589-1884 100 70