KK-1328-32 

KK-1328-32
This filter series is intended to provide common mode
and differential insertion loss for DC power systems.
This filter can be used for either commercial applications
or for applications involving MIL-STD -461D, E, or F.
If the older 461C spec is required, the circuit can be
rearranged to accommodate the C version.
If severe shock or vibration are required, please contact
our engineering department to discuss any necessary
modifications.
Operating Voltage = __________________ 18 - 36 VDC
Operating Current (max) = ________________ 32 Amps
INSERTION LOSS vs. FREQUENCY
Temperature range (storage) = ___________-55 to 85°C
Temperature range (operating)
32 A = -40 to 55°C
30 A = " 60°C
28 A = " 64°C
24 A = " 73°C
22 A = " 78°C
Calculated MTBF = ________7,386,888 Hrs GB @ 30°C
USA
JMK Inc 15 Caldwell Dr. Amherst, NH 03031
PH: 603 886-4100
FX: 603 886-4115
email: [email protected]
PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884
EUR
JMK Inc Glasgow G13 1DN Scotland UK