JMK. Inc. HH-1355-6.3 The HH-1355-6.3 filter has been designed to operate with the VICOR Harmonic Attenuator Module (HAM). This filter was specifically designed to allow the Vicor HAM and associated power converters to meet Mil-Std461C or Mil-Std-461D,E & F The enclosure mounting, and pin configuration are identical to the enclosure for the standard HAM filter. It will be necessary to add transient protection across the output of the filter to protect the HAM module. It is recommended that you use 5%, bipolar TVS diodes. 2 x 130V and 1 x 150V diodes connected in series. The HAM will meet Mil-Std-461C with the HH-1355-6.3. Additional circuitry is required on the input in order to meet Mil-Std-461D. The filter is available in both the standard model and a high temperature model. Order P/N: HH-1355-6.3 HH-1355-6.3HT (Hi Temp model) Operating voltage = 85 to 250 V~ Operating current = 6.3 Amp Operating frequency = 50/60 Hz Operating temperature = See temp. curve for the two models. Diel. withstanding (line - case) = 1500 Vac Diel. withstanding (line - line) = 1500 Vdc Leakage current = 2.5 ma at 220 Vac, 60 Hz Max residual voltage after 1 sec. = 34 Volts Applicable Specifications = Mil-Std-461C Mil-Std-461D MTBF = 1,789,641 hours GB USA JMK Inc 15 Caldwell Dr. Amherst, NH 03031 EUR JMK Inc Glasgow G13 1DN Scotland UK PH: 603 886-4100 FX: 603 886-4115 email: [email protected] PH: 44-(0) 7785310729 FX: 44-(0) 141-589-1884