KK-1328-40 This filter delivers high common mode and differential mode insertion loss for DC Power Systems. The filter can be used for either commercial applications or for applications involving MIL-STD-461D, E, or F. If the older MIL-STD– 461C is required, the circuit can be re-arranged to accommodate the “C” version. If severe shock and vibration is a requirement, contact our engineering department to discuss any possible mechanical modifications. Operating Voltage = ____________________0 to 63Vdc Operating Current = ______________________ 40 Amp Operating Temperature = 40 AMP = _____________________ (-20 - 50ºC) 37 AMP = _____________________ (-20 - 55ºC) 35 AMP = _____________________ (-20 - 60ºC) 30 AMP = _____________________ (-20 - 67ºC) 27 AMP = _____________________ (-20 - 72ºC) Storage Temperature = _______________-40ºC - 100ºC Diel. Withstanding (L-Case) = _____________ 1000 Vdc Diel. Withstanding (L-L) = ________________ 1000 Vdc Max Residual Volt after 1 sec = _____________34 Volts Weight = _________________________________1.9 lb Max Torque on Terminals = _________________25 in.lb INSERTION LOSS vs. FREQUENCY Calculated MTBF = _____________7,386,888 Hrs @ 30°C GB Failure Rate = _______________________________0.135375 USA JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115 email: [email protected] PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884 EUR JMK Inc Glasgow G13 1DN Scotland UK