KK-1328-40

KK-1328-40
This filter delivers high common mode and differential
mode insertion loss for DC Power Systems.
The filter can be used for either commercial applications
or for applications involving MIL-STD-461D, E, or F.
If the older MIL-STD– 461C is required, the circuit can be
re-arranged to accommodate the “C” version.
If severe shock and vibration is a requirement, contact
our engineering department to discuss any possible
mechanical modifications.
Operating Voltage = ____________________0 to 63Vdc
Operating Current = ______________________ 40 Amp
Operating Temperature =
40 AMP = _____________________ (-20 - 50ºC)
37 AMP = _____________________ (-20 - 55ºC)
35 AMP = _____________________ (-20 - 60ºC)
30 AMP = _____________________ (-20 - 67ºC)
27 AMP = _____________________ (-20 - 72ºC)
Storage Temperature = _______________-40ºC - 100ºC
Diel. Withstanding (L-Case) = _____________ 1000 Vdc
Diel. Withstanding (L-L) = ________________ 1000 Vdc
Max Residual Volt after 1 sec = _____________34 Volts
Weight = _________________________________1.9 lb
Max Torque on Terminals = _________________25 in.lb
INSERTION LOSS vs. FREQUENCY
Calculated MTBF = _____________7,386,888 Hrs @ 30°C GB
Failure Rate = _______________________________0.135375
USA
JMK Inc 15 Caldwell Dr. Amherst, NH 03031
PH: 603 886-4100
FX: 603 886-4115
email: [email protected]
PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884
EUR
JMK Inc Glasgow G13 1DN Scotland UK