AA-1355-13HT The AA-1355-13HT filter has been designed to operate with two VICOR Harmonic Attenuator Modules (HAM). This filter was specifically designed to allow the Vicor HAM and ass oc iated power conver ters to m eet Mil-Std-461D, E or F. This version of the filter is configured for those applications where a chassis mount for the filter is preferred. Ordering Information: P/N: AA-1355-13 (STD) P/N: AA-1355-13HT (High Temp) Operating Voltage = ___________________ 85 to 275 V Operating Current = ______________________ 13 Amp Operating Frequency = __________________50/400 Hz Max. Volt Drop @ 13 amps = _________________ 0.8 V INSERTION LOSS vs. FREQUENCY Operating Temperature, High = ________________60ºC Operating Temperature, Low = _______________ -40ºC Diel. Withstanding (line - case) = ___________1500 Vac Diel. Withstanding (line - line) = ____________1500 Vdc Leakage Current = ___________2.5 ma @ 220 V, 60 Hz Max Residual Voltage after 1 sec = _____________34 V Calculated MTBF = ________2,142,107 Hrs @ 30°C GB USA JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115 email: [email protected] PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884 EUR JMK Inc Glasgow G13 1DN Scotland UK