Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_2 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater control systems, and contributes to maintenance improvements by the user. • Main detection items: SSR short-circuits and SSR open-circuits • Alarm output possible to NPN/PNP-input devices. • The failure-detection function is built-in and power is supplied from the main circuit power supply making wiring simple. • Slim design (width: 22.5 mm) incorporating a heat sink. • In addition to screw mounting, DIN track mounting is also possible. • Certified by EC, UL, and CSA. Model Number Structure ■ Model Number Legend G3PC-@@@-@ 1 2 3 4 5 1. Basic Model Name G3PC: SSR with Failure Detection Function 2. Rated Load Power Supply Voltage 2: 100 to 240 VAC 3. Rated Load Current 20: 20 A (carry current) 4. Terminal Type B: Screw terminals 5. Certification VD: Certified by UL, CSA, and VDE Ordering Information ■ List of Models Insulation method Phototriac coupler Zero cross function Yes Indicators Yes (See page 5) Rated output load 20 A, 100 to 240 VAC (resistive load: AC, Class1) Model number G3PC-220B-VD Note: When ordering, specify the rated input voltage. ■ Accessories (Order Separately) Name Mounting Track Dimensions 50 cm (l) × 7.3 mm (t) Model number PFP-50N 1 m (l) × 7.3 mm (t) PFP-100N 1 m (l) × 16 mm (t) PFP-100N2 1 G3PC Specifications ■ Ratings (at an Ambient Temperature of 25°C) Detection Power Supply Main Circuit Rated power supply voltage 100 to 240 VAC (50/60 Hz) Rated load voltage 100 to 240 VAC (50/60 Hz) Operating voltage range 75 to 264 VAC (50/60 Hz) Operating voltage range 75 to 264 VDC (50/60 Hz) Current consumption 15 mA AC max. (at 200 VAC) Applicable load current 20 A (Ta = 40) Minimum load current 0.1 A Inrush current resistance (peak value) 220 A (60 Hz, 1 cycle) Operating Circuit 2 Input method Voltage input Permissible (I t) 260 A2s Applicable load (with Class-1 AC resistive load) 4 kW (at 200 VAC) Rated input voltage 12 to 24 VDC Operating input voltage range 9.6 to 30 VDC Must operate voltage 9.6 VDC max. Must release voltage 1 VDC min. Output OFF collector voltage 30 VDC max. Input current 7 mA DC max. (at rated input voltage) Maximum carry current 0.1 A Output form Independent NPN open collector Alarm Output ■ Characteristics Operate time 1/2 of load power source cycle + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Main circuit Alarm output Output ON voltage drop 1.6 V rms max. OFF leakage current 10 mA max. (at 200 VAC) Output ON voltage drop 1.5 V max. OFF leakage current 0.1 mA max. Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to10 Hz, 0.35-mm single amplitude Shock resistance Destruction: 294 m/s2 Ambient temperature Operating: −20 to 60°C (with no icing or condensation) Storage: −30 to 70°C (with no icing or condensation) Ambient humidity 45% to 85% Weight Approx. 300 g Certified standards UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3); Certified by VDE EMC Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 Engineering Data Ta = +25°C 8 The figure will be less than 1/2 the rated value for repetitive input. 25 20 Input impedance 6 15 4 One Cycle Surge Current: Non-repetitive Inrush current (A. Peak) 10 Load Current vs. Ambient Temperature Load current (A) Input impedance (kΩ) Input current (mA) Input Voltage vs. Input Current Input Voltage vs. Input Impedance 250 200 150 10 100 5 50 Input current 2 0 0 10 20 30 40 Input voltage (V) -20 0 20 40 60 80 100 Ambient temperature (°C) 0 10 30 50 100 300 500 1,000 3,000 5,000 Energized time (ms) 2 G3PC Operation ■ Failure Detection Function Conditions for SSR Failure Detection Failure mode (See note 1.) Operating input (between terminals A1 and A2) Detection time Alarm display (See note 3.) SSR short-circuit OFF 0.5 s max. (See note 2.) Red Open collector transistor output SSR half-wave short-circuit OFF SSR open-circuit Alarm display (between terminals X1 and X2) (See note 3.) ON SSR half-wave open-circuit ON Note: 1. The contents of each of the above failure modes is as follows: SSR short-circuit: SSR output circuit remains in the ON state. SSR half-wave short-circuit: SSR output circuit remains in the ON state in one direction. SSR open-circuit: SSR output circuit remains in the OFF state. SSR half-wave open-circuit: SSR output circuit remains in the OFF state in one direction. In addition to the failure modes listed above, detection of circuit disconnections for the load circuit is also possible. (As a rough guide, circuit disconnection will be detected if the load impedance is greater than or equal to 1 MΩ.) 2. The same power supply is used for both the detection and for the output circuit and so detection is not performed during power interruptions. 3. If power supply (terminal 3) is in the open state, the SSR will still turn ON and OFF in the same way but the failure detection function and alarm display will not operate properly. Connection Diagrams (Main Circuit) The following diagrams show the applicable load connection configurations for SSR failure detection. Single Phase 3-phase Star Connection G3PC G3PC 3-phase Delta Connection (3-phase, 2-wire Switching) G3PC G3PC G3PC G3PC 3-phase V Connection G3PC G3PC Heater er at er He at He er at He er er er at at at He He He Heater Heater Note: 1. With 3-phase connection, so that the power supply voltage is applied between the G3PC’s terminals 1/L1 and 3, connect the desired phase to terminal 3. 2. When grounding to a neutral point with a three-phase start connection, an overvoltage will be applied to the G3PC if the neutral point becomes disconnected, possibly causing product failure. Make sure the connection to the neutral point is secure. 3. Detection is not possible for the heater indicated with an asterisks with a three-phase delta connection. Timing Chart SSR failure detection SSR ON normally Main circuit power supply (load side) SSR OFF normally SSR short-circuit Reset (See note.) SSR open-circuit Circuit disconnection detection on the load side Reset (See note.) Load circuit disconnection Reset (See note.) Operating input (between terminals A1 and A2) Input LED (yellow) Load current RDY/ALM LED (Green: ; Red: ) Alarm output (between terminals X1 and X2) Note: After failure detection, if the detection conditions differ to the conditions given under Conditions for SSR Failure Detection, alarm output is reset. 3 G3PC Dimensions G3PC-220B-VD Mounting Holes 130 max. Terminal cover 114.4 22.5 max. Tow, 4.6 dia. 13 Three, 4.5 dia. or M4 13.5 68 100 max. 90±0.2 80 8.5x3 = 25.5 4.5 90±0.3 4.6x5.6 elliptic hole Note The above diagram is for when the terminal cover is open. 84.2 13±0.3 Note The above diagram is for when the terminal cover is closed. Accessories (Order Separately) Mounting Tracks PFP-100N, PFP-50N PFP-100N2 16 7.3±0.15 4.5 4.5 35±0.3 25 25 15 25 10 25 1,000(500) (500) 10 1,000 (see note) (see note) 27±0.15 15 (5) (see note) 35±0.3 27 24 15 25 10 25 25 1,000 10 25 15 1 29.2 1.5 Note Values in parentheses indicate dimensions for the PFP-50N. 4 G3PC Installation ■ External Specifications Appearance Terminal Arrangement Terminal name Terminal number Main circuit terminals 1/L1, 2/T1 (output) 1/L1 Screw size M4 3 RDY/ALM Detection power sup- 3 ply terminal (input) A1(IN+) Operating circuit terminals (input) A1, A2 Alarm output terminals (output) X1, X2 INPUT A2(IN−) M3.5 X1(ALM+) X2(ALM−) 2/T1 Indicators Name Status indicators Input indicator Symbol Color Meaning RDY Green SSR normal ALM Red SSR failure detection and circuit disconnection detection INPUT Yellow Operating Note: The same indicator is used as both the power supply indicator and the alarm indicator. ■ Connection Example (See note 1.) Display Labels L1 1 AC 3 Voltage output for Temperature Controller, sequencer A1 12 to 24 VDC IN A2 X1 Input for Temperature Controller, sequencer ALM X2 30 VDC min. 2 T1 (See note 2.) Heater Note: 1. If the detection power supply terminal (terminal 3) is not connected, failure detection is not performed and so be sure to connect this terminal. 2. If the load is connected to terminal 1/L1, failure detection may not operate correctly and so connect the load to terminal 2/T1. 3. With inductive loads (relay coil, etc.), connect back-current prevention diodes to both sides of the load. 5 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2009.1 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2009 All Right Reserved. Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2009.1 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2009 All Right Reserved.