OPTOTRONIC® OTe 10/220-240/700 PC 700mA Constant Current LED Power Supply with Phase Cut functionality 1. Technical Data Nominal Voltage 220 – 240 Vac Output Voltage Input Voltage 198 – 264 Vac Maximum Output Voltage Line Current, nominal 65mA @ 230 Vac Nominal Output Current Mains Frequency 50 / 60 Hz Typ.dimming range* Power Factor 0.95 @ 230 Vac Ambient Temperature Maximum Output Power Pmax 10 W Max. Case Temperature at tc IP Rating IP 20 Max. Output Cable Length * Suitable for use with electronic leading and trailing edge dimmer 7 – 14Vdc 25Vdc 700mA DC +/- 10% 10 - 100% -20°C to +55°C +80°C 2m 2. Connection Schemes 2.1 LED modules in series: + 220 - 240VAC OTe 10/220-240/700 PC LED Module 2 - LED modules should be connected in series. 2.2 Parallel connection on the secondary side is not allowed + OTe 10/220-240/700 PC 2 + 220-240VAC OTe 10/220-240/700 PC 2 - + LED-Module 700mA , 5W-10W LED-Module 700mA , 5W-10W 2 OTe 10/220-240/700 PC + 220-240VAC 2 OTe 10/220-240/700 PC + + 2 OTe 10/220-240/700 PC - LED-Module 700mA , 5W-10W + 220-240VAC 2 OTe 10/220-240/700 PC to LED 2 220-240VAC 2 - OTe 10/220-240/700 PC - + OTe 10/220-240/700 PC + to LED OTe 10/220-240/700 PC 2 - to LED OTe 10/220-240/700 PC - + 2 OTe 10/220-240/700 PC to LED - + 2 LED-Module 700mA, 30W + to LED - 2 Common Cathode prohibited OTe 10/220-240/700 PC to LED - Common Anode prohibited The installation of two or more OPTOTRONIC OTe 10/220-240/700 PC Power Supplies with common “-“ or “+” wiring by the intention to save wire to LED modules is prohibited, in order to avoid exceeding the maximum allowed system touch current levels on the accessible parts of the installation. OSRAM AG www.osram.com Steinerne Furt 62, 86167 Augsburg, Germany 2014-4-29 AA6268800DG No. 1, North Industrial Road 528000 Foshan Guangdong, P.R. China OPTOTRONIC® OTe 10/220-240/700 PC 700mA Constant Current LED Power Supply with Phase Cut functionality 3. Wire and Connection Ensure that the LED module load is within the range of rated voltage, current and power supply (see Technical data) The luminaries’ manufacturer is responsible for providing the required clearance and creepage distances and also for the protection against electrical shock, especially for the line and load wires. Wiring Preparation: 4. Earth Connection OTe 10/220-240/700 PC is a “Protection Class II” power supply, therefore ground connection is not required 5. Mounting and Environmental protection The control gear is a built in type for luminaire integration; an optional cable clamp is available for independent installation; proper cables should be used. Maximum permissible ambient temperature must not be exceeded. Make sure there is adequate space to avoid heat build-up. In critical installations, the temperature at tc point should not exceed the declared value. 6. General note Power supplies must be installed by qualified electrician Disconnected from mains supply before wiring work Hot plug-in or secondary switching of LEDs is not permitted, as it may cause a very high transient current to the LEDs For further information, please refer to “OPTOTRONIC -Technical guide” at www.osram.com Proper and safety usage and installation of the product shall comply with product datasheet and OPTOTRONIC Technical guide. The latest documents are available at www.osram.com OSRAM AG www.osram.com Steinerne Furt 62, 86167 Augsburg, Germany 2014-4-29 AA6268800DG No. 1, North Industrial Road 528000 Foshan Guangdong, P.R. China