1. Technical Data
Nominal Voltage
220 – 240 Vac
Output Voltage
Input Voltage
198 – 264 Vac
Maximum Output Voltage
Line Current, nominal
150mA @ 230 Vac
Nominal Output Current
Mains Frequency
50 / 60 Hz
Typ.dimming range*
Power Factor
0.95 @ 230 Vac
Ambient Temperature
Maximum Output Power Pmax 25 W
Max. Case Temperature at tc
IP Rating
IP 20
Max. Output Cable Length
* Suitable for use with electronic leading and trailing edge dimmer
18 – 36Vdc
50Vdc
700mA DC +/- 10%
10 - 100%
-20°C to +50°C
+75°C
2m
2. Connection Schemes
2.1 LED modules in series:
+
220 - 240VAC
OTe 25/220-240/700 PC
LED Module
2
-
LED modules should be connected in series.
2.2 Parallel connection on the secondary side is not allowed
+
OTe 25/220-240/700 PC
2
+
220-240VAC
OTe 25/220-240/700 PC
2
-
+
LED-Module
700mA , 12.5W-25W
LED-Module
700mA , 12.5W-25W
2
OTe 25/220-240/700 PC
+
220-240VAC
2
OTe 25/220-240/700 PC
+
+
OTe 25/220-240/700 PC
2
-
LED-Module
700mA , 12.5W-25W
+
220-240VAC
OTe 25/220-240/700 PC
2
to LED
2
OTe 25/220-240/700 PC
-
+
220-240VAC
2
-
OTe 25/220-240/700 PC
2
+
to LED
2
-
to LED
OTe 25/220-240/700 PC
-
+
2 OTe 25/220-240/700 PC
to LED
-
+
OTe 25/220-240/700 PC
LED-Module
700mA, 75W
+
to LED
-
2
Common Cathode prohibited
OTe 25/220-240/700 PC
to LED
-
Common Anode prohibited
The installation of two or more OPTOTRONIC OTe 25/220-240/700 PC Power Supplies with common
“-“ or “+” wiring by the intention to save wire to LED modules is prohibited, in order to avoid exceeding
the maximum allowed system touch current levels on the accessible parts of the installation.
OSRAM AG
www.osram.com
Steinerne Furt 62, 86167 Augsburg, Germany
2014-4-29
AA6117300DG
No. 1, North Industrial Road
528000 Foshan Guangdong, P.R. China
OPTOTRONIC®
OTe 25/220-240/700 PC
350mA Constant Current LED Power Supply with Phase Cut functionality
3. Wire and Connection



Ensure that the LED module load is within the range of rated voltage, current and power supply (see
Technical data)
The luminaries’ manufacturer is responsible for providing the required clearance and creepage distances
and also for the protection against electrical shock, especially for the line and load wires.
Wiring Preparation:
4. Earth Connection

OTe 25/220-240/700 PC is a “Protection Class II” power supply, therefore ground connection is not
required
5. Mounting and Environmental protection


The control gear is a built in type for luminaire integration; an optional cable clamp is available for
independent installation; proper cables should be used.
Maximum permissible ambient temperature must not be exceeded. Make sure there is adequate space to
avoid heat build-up. In critical installations, the temperature at tc point should not exceed the declared
value.
6. General note




Power supplies must be installed by qualified electrician
Disconnected from mains supply before wiring work
Hot plug-in or secondary switching of LEDs is not permitted, as it may cause a very high transient current
to the LEDs
For further information, please refer to “OPTOTRONIC -Technical guide” at www.osram.com
Proper and safety usage and installation of the product shall comply with product
datasheet and OPTOTRONIC Technical guide. The latest documents are
available at www.osram.com
OSRAM AG
www.osram.com
Steinerne Furt 62, 86167 Augsburg, Germany
2014-4-29
AA6117300DG
No. 1, North Industrial Road
528000 Foshan Guangdong, P.R. China