Features • • • • • • • • • • • • • 80C51 Compatible CPU Core High-speed Architecture X2 Speed Improvement Capability (6 Clocks/Machine Cycle) 16 MHz in Standard or X2 mode 256 Bytes RAM 256 Bytes XRAM 12K Bytes ROM/OTP Program Memory Two 16-bit Timer/Counters T0, T1 5 Channels Programmable Counter Array with High-speed Output, Compare/Capture, Pulse Width Modulation and Watchdog Timer Capabilities SPI Interface (Master and Slave mode) Interrupt Structure with: – 6 Interrupt Sources – 4 Interrupt Priority Levels Power Supply: 3 - 5.5V Temperature Range: Industrial (-40oC to 85oC), Automotive (-40oC to 125oC) Package: SSOP16, SSOP24 Description The AT8xC5103 is a high-performance ROM/OTP version of the 80C51 8-bit Microcontroller in 16 and 24-pin packages. Low-pin Count 8-bit Microcontroller AT87C5103 AT83C5103 The AT8xC5103 contains a standard C51 CPU core with 12 Kbytes ROM/OTP program memory, 256 bytes of internal RAM, 256 bytes of extended internal RAM, a 5sources 4-level interrupt system, two timer/counters and a SPI serial bus controller. The AT8xC5103 is also dedicated for analog interfacing applications. For this, it has a five channels Programmable Counter Array. In addition, the AT8xC5103 implements the X2 speed improvement mechanism. The X2 feature allows to keep the same CPU power at a divided by two oscillator frequency. The fully static design of the AT8xC5103 allows to reduce system power consumption by bringing the clock frequency down to any value, even DC, without loss of data. Rev. 4134D–8051–02/08 1 MISO MOSI SPSCK SS (1) (1) (1)(1)(3)(1) Vcc Vss ECI CEX0-4 Block Diagram XTAL1 XTAL2 Xtal Osc EXRAM RAM 256x8 256x8 C51 CORE ROM 12 K *8 SPI PCA IB-bus CPU Notes: Parallel I/O Ports Port 1Port 3 Port 4 P4 P3 (3) (3) P1 T0 T1 RST (3) (3) INT Ctrl INT0 INT1 Timer 0 Timer 1 1. Alternate function of Port 1. 2. Alternate function of Port 3. 2 4134D–8051–02/08 Pin Configurations P3.2/DIG0/INT0 P3.4/DIG1/T0 1 16 2 15 14 P1.7/CEX4/SS P1.6/CEX3 P1.5/CEX2 P1.4/CEX1 P1.3/CEX0 P1.2/ECI/DIG2 P3.6/SPICK VSS VCC RST/VPP 3 4 6 12 11 XTAL2 XTAL1 7 8 10 9 P1.1/MOSI P3.2/DIG0/INT0 1 2 3 4 5 6 7 8 24 23 22 21 20 P3.1 P3.0 P1.7/CEX4/SS P3.3/INT1 P3.4/DIG1/T0 P3.5/T1 P3.6/SPICK VSS 5 VCC RST/VPP XTAL2 9 XTAL1 10 P4.0 11 P4.1 12 SSOP16 SSOP24 13 19 18 17 16 15 14 13 P1.0/MISO P1.6/CEX3 P1.5/CEX2 P1.4/CEX1 P3.7 P1.3/CEX0 P1.2/ECI/DIG2 P4.2 P1.1/MOSI P1.0/MISO 3 4134D–8051–02/08 Pin Description Mnemonic Type Name and Function VSS I Ground: 0V reference VCC I Power Supply: 3.0V or 5.5V P1.0 - P1.7 I/O Port 1: Port 1 is an 8-bit programmable I/O port with internal pull-up Alternate functions for Port 1 include: I/O MISO (P1.0): Master IN, Slave OUT of the SPI controller I/O MOSI (P1.1): Master OUT, Slave IN of the SPI controller I/O DIG2 (P1.2): Programmable as Output with Push-pull ECI: External Clock for PCA I/O CEX0 (P1.3): Capture/Compare External I/O for PCA module 0 I/O CEX1 (P1.4): Capture/Compare External I/O for PCA module 1 I/O CEX2 (P1.5): Capture/Compare External I/O for PCA module 2 I/O CEX3 (P1.6): Capture/Compare External I/O for PCA module 3 I/O SS (P1.7): Slave select input of the SPI controller CEX4: Capture/Compare External I/O for PCA module 3 XTAL1 I Input to the inverting oscillator amplifier XTAL2 O Output from the inverting oscillator amplifier I RST: Negative Reset input A low on this pin for two machine cycles while the oscillator is running, resets the device. This pin will include a pull-down to reset the circuit if no external reset level is applied. VPP: High voltage input for OTP programming RST/VPP P3.0 - P3.7 P4.0-P4.2 I/O Port 3: Port 3 is a 8-bit programmable I/O port with internal pull-up. I/O P3.0: Programmable as Output with Push-pull. I/O P3.1: Programmable as Output with Push-pull. I/O DIG0 (P3.2): Programmable as Output with Push-pull. INT0: External Interrupt 0 I/O P3.3: Programmable as Output with Push-pull. INT1: External Interrupt 1 I/O DIG1 (P3.4): Programmable as Output with Push-pull. T0: Timer 0 external Input I/O P3.5: Programmable as Output with Push-pull. T1: Timer 1 external Input I/O SPICK (P3.6): Clock I/O of the SPI controller I/O P3.7: Programmable as Output with Push-pull. I/O Port 4: Port 4 is an 3-bit I/O port with internal pull-up 4 4134D–8051–02/08 Clock The Errata Sheet core needs only 6 clock periods per machine cycle. This feature, called ”X2”, provides the following advantages: • Divides frequency crystals by 2 (cheaper crystals) while keeping the same CPU power. • Saves power consumption while keeping the same CPU power (oscillator power saving). • Saves power consumption by dividing dynamic operating frequency by 2 in operating and idle modes. • Increases CPU power by 2 while keeping the same crystal frequency. In order to keep the original C51 compatibility, a divider-by-2 is inserted between the XTAL1 signal and the main clock input of the core (phase generator). This divider may be disabled by the software. Description The clock for the whole circuit and peripheral is first divided by 2 before being used by the CPU core and peripherals. This allows any cyclic ratio to be accepted on the XTAL1 input. In X2 Mode, as this divider is bypassed, the signals on XTAL1 must have a cyclic ratio between 40 to 60%. Figure 1. shows the clock generation block diagram. The X2 bit is validated on the XTAL1 ÷ 2 rising edge to avoid glitches when switching from the X2 to the STD mode. Figure 2 shows the mode switching waveforms. 5 4134D–8051–02/08 Figure 1. Clock CPU Generation Diagram PCON.0 IDL X2 CKCON.0 XTAL1 ÷2 FCLK_PERIPH FCPU 0 1 XTAL2 PD PCON.1 ÷2 1 FT0 Clock 0 ÷2 1 FT1 Clock 0 ÷2 1 FPCA Clock 0 ÷2 1 FSPI Clock 0 X2 CKCON0.0 Peripheral Clock Symbol PCAX2 T1X2 T0X2 CKCON0.7 CKCON0.6 CKCON0.5 CKCON0.4 CKCON0.3 CKCON0.2 CKCON0.1 SPIX2 CKCON1.7 CKCON1.6 CKCON1.5 CKCON1.4 CKCON1.3 CKCON1.2 CKCON1.1 CKCON1.0 6 4134D–8051–02/08 Figure 2. Mode Switching Waveforms XTAL1 XTAL2 X2 Bit CPU Clock STD Mode X2 Mode STD Mode The X2 bit in the CKCON register (See Table 1) allows switching from 12 clock cycles per instruction to 6 clock cycles and vice versa. At reset, the standard speed is activated (STD mode). Setting this bit activates the X2 feature (X2 Mode). Note: In order to prevent any incorrect operation while operating in the X2 Mode, users must be aware that all peripherals using the clock frequency as a time reference (timers, PCA, SPI) will have their time reference divided by 2. For example, a free running timer generating an interrupt every 20 ms will then generate an interrupt every 10 ms. 7 4134D–8051–02/08 Registers Table 1. CKCON0 Register CKCON0 (S:8Fh) Clock Control Register 7 6 5 4 3 PCAX2 Bit Number 2 1 0 T1X2 T0X2 X2 Bit Mnemonic Description 7 – Reserved The value read from this bit is indeterminate. Do not set this bit. 6 – Reserved The value read from this bit is indeterminate. Do not set this bit. 5 PCAX2 4 – Reserved The value read from this bit is indeterminate. Do not set this bit. 3 – Reserved The value read from this bit is indeterminate. Do not set this bit. 2 T1X2 Programmable Counter Array clock (1) Clear to select 6 clock periods per peripheral clock cycle. Set to select 12 clock periods per peripheral clock cycle. Timer1 Clock (1) Clear to select 6 clock periods per peripheral clock cycle. Set to select 12 clock periods per peripheral clock cycle. Timer0 Clock (1) 1 0 Note: T0X2 X2 Clear to select 6 clock periods per peripheral clock cycle. Set to select 12 clock periods per peripheral clock cycle. CPU Clock Clear to select 12 clock periods per machine cycle (STD mode) for CPU and all the peripherals. Set to select 6 clock periods per machine cycle (X2 Mode) and to enable the individual peripherals "X2" bits. 1. This control bit is validated when the CPU clock bit X2 is set; when X2 is low, this bit has no effect. Reset Value = XX0X X000b 8 4134D–8051–02/08 Table 2. CKCON1 Register CKCON1 (S:AFh) Clock Control Register 7 6 5 4 3 2 1 0 SPIX2 Bit Number Bit Mnemonic Description 7 – Reserved The value read from this bit is indeterminate. Do not set this bit. 6 – Reserved The value read from this bit is indeterminate. Do not set this bit. 5 – Reserved The value read from this bit is indeterminate. Do not set this bit. 4 – Reserved The value read from this bit is indeterminate. Do not set this bit. 3 – Reserved The value read from this bit is indeterminate. Do not set this bit. 2 – Reserved The value read from this bit is indeterminate. Do not set this bit. 1 – Reserved The value read from this bit is indeterminate. Do not set this bit. 0 SPIX2 SPI clock (1) Note: Clear to select 6 clock periods per peripheral clock cycle. Set to select 12 clock periods per peripheral clock cycle. 1. This control bit is validated when the CPU clock bit X2 is set; when X2 is low, this bit has no effect. Reset Value = XXXX XXX0b 9 4134D–8051–02/08 SFR Mapping The Special Function Registers (SFRs) of the AT8xC5103 belong to the following categories: • C51 core registers: ACC, B, DPH, DPL, PSW, SP, AUXR1 • I/O port registers: P1, P3, P4, P1M1, P1M2, P3M1, P3M2 • Timer registers: TCON, TH0, TH1, TMOD, TL0, TL1 • Power and clock control registers: CKCON0, CKCON1, PCON • Interrupt system registers: IE, IE1, IPL0, IPL1, IPH0, IPH1 • SPI: SPCON, SPSTA, SPDAT • PCA: CCAP0L, CCAP1L, CCAP2L, CCAP3L, CCAP4L, CCAP0H, CCAP1H, CCAP2H, CCAP3H, CCAP4H, CCAPM0, CCAPM1, CCAPM2, CCAPM3, CCAPM4, CL, CH, CMOD, CCON 10 4134D–8051–02/08 Table 3. SFR Addresses and Reset Values 0/8 F8h F0h 1/9 2/A 3/B 4/C 5/D 6/E CH 0000 0000 CCAP0H 0000 0000 CCAP1H 0000 0000 CCAP2H 0000 0000 CCAP3H 0000 0000 CCAP4H 0000 0000 7/F FFh B 0000 0000 F7h CL 0000 0000 E8h E0h ACC 0000 0000 D8h CCON 00X0 0000 D0h PSW 0000 0000 CCAP0L 0000 0000 CCAP1L 0000 0000 P1M2 0000 0000 CMOD 00XX X000 CCAPM0 X000 0000 CCAP2L 0000 0000 CCAP3L 0000 0000 CCAP4L 0000 0000 EFh P3M2 0000 0000 CCAPM1 X000 0000 E7h CCAPM2 X000 0000 CCAPM3 X000 0000 P1M1 P3M1 0000 0000 0000 0000 CCAPM4 X000 0000 DF h D7h CF h C8h C0h P4 XXXX X111 B8h IPL0 X0XX 0000 B0h P3 1111 1111 A8h IE0 00XX 0000 SPCON 0001 0100 SPSTA SPDAT 00X0 XXXX XXXX XXXX C7h BFh IE1 XXXX X0XX IPL1 XXXX X0XX IPH1 XXXX X0XX IPH0 X0XX 0000 B7h CKCON1 XXXX XXX0 AFh AUXR1 XXXXX0X0 A0h A7h 9Fh 98h 90h 88h P1 97h 1111 1111 TCON 0000 0000 80h 0/8 TMOD 0000 0000 TL0 0000 0000 TL1 0000 0000 SP 0000 0111 DPL 0000 0000 DPH 0000 0000 1/9 2/A 3/B TH0 0000 0000 TH1 0000 0000 CKCON0 XX0X X000b PCON XXX1 0000 4/C 5/D 6/E 8Fh 87h 7/F Reserved 11 4134D–8051–02/08 Ports The AT8xC5103 has 3 I/O ports, port 1, port 3 and port 4. Except RST, and port 4, all port 1 and port 3 I/O port pins on the AT8xC5103 may be software configured to one of four types on a bit-by-bit basis, as shown in Table 2 These are: quasi-bi-directional (standard 80C51 port outputs), push-pull, open drain, and input only. Two configuration registers for each port choose the output type for each port pin. PxM1.y BIt PxM2.y Bit Port Output Mode 0 0 Quasi bi-directional 0 1 Push-pull 1 0 Input Only (High Impedance) 1 1 Open Drain Port Types Quasi-Bi-directional Output Configuration The default port output configuration for standard AT8xC5103 I/O ports is the quasi-bidirectional output that is common on the 80C51 and most of its derivatives. This output type can be used as both an input and output without the need to reconfigure the port. This is possible because when the port outputs a logic high, it is weakly driven, allowing an external device to pull the pin low. When the pin is pulled low, it is driven strongly and able to sink a fairly large current. These features are somewhat similar to an open drain output except that there are three pull-up transistors in the quasi-bi-directional output that serve different purposes. One of these pull-ups, called the ‘very weak’ pull-up, is turned on whenever the port latch for the pin contains a logic 1. The very weak pull-up sources a very small current that will pull the pin high if it is left floating. A second pullup, called the ‘weak’ pull-up, is turned on when the port latch for the pin contains a logic 1 and the pin itself is also at a logic 1 level. This pull-up provides the primary source current for a quasi-bi-directional pin that is outputting a 1. If a pin that has a logic 1 on it is pulled low by an external device, the weak pull-up turns off, and only the very weak pullup remains on. In order to pull the pin low under these conditions, the external device has to sink enough current to overpower the weak pull-up and take the voltage on the port pin below its input threshold. The third pull-up is referred to as the ‘strong’ pull-up. This pull-up is used to speed up low-to-high transitions on a quasi-bi-directional port pin when the port latch changes from a logic 0 to a logic 1. When this occurs, the strong pull-up turns on for a brief time, two CPU clocks, in order to pull the port pin high quickly. Then it turns off again. The quasi-bi-directional port configuration is shown in Figure 3. 12 4134D–8051–02/08 Figure 3. Quasi-Bi-directional Output 2 CPU Clock Delay P Strong P Very Weak P Weak Pin Port latch Data N Input Data Open Drain Output Configuration The open-drain output configuration turns off all pull-ups and only drives the pull-down transistor of the port driver when the port latch contains a logic 0. To be used as a logic output, a port configured in this manner must have an external pull-up, typically a resistor tied to VDD. The pull-down for this mode is the same as for the quasi-bi-directional mode. The open drain port configuration is shown in Figure 4. Figure 4. Open Drain Output Pin Port latch Data N Input Data Push-Pull Output Configuration The push-pull output configuration has the same pull-down structure as both the open drain and the quasi-bi-directional output modes, but provides a continuous strong pullup when the port latch contains a logic 1. The push-pull mode may be used when more source current is needed from a port output. The push-pull port configuration is shown in Figure 5. Figure 5. Push-pull Output P Strong Pin Port Latch Data N Input Data 13 4134D–8051–02/08 Input Only Configuration The input only configuration is a pure input with neither pull-up nor pull-down. The input only configuration is shown in Figure 6. Figure 6. Input Only Input Data Pin Ports Description Ports P1 and P3 The inputs of each I/O port of the AT8xC5103 are TTL level Schmitt triggers with hysteresis. Registers Table 4. P1M1 Register P1M1 Address (D4h) 7 6 5 4 3 2 1 0 P1M1.7 P1M1.6 P1M1.5 P1M1.4 P1M1.3 P1M1.2 P1M1.1 P1M1.0 Bit Bit Number Mnemonic 0-7 P1M1.x Description Port Output configuration Bit See Table 2 for configuration definition Reset Value = 0000 0000 Table 5. P1M2 Register P1M2 Address (E2h) 7 6 5 4 3 2 1 0 P1M2.7 P1M2.6 P1M2.5 P1M2.4 P1M2.3 P1M2.2 P1M2.1 P1M2.0 Bit Number Bit Mnemonic 0-7 P1M2.x Description Port Output configuration bit See Table 2 for configuration definition Reset Value = 0000 0000 14 4134D–8051–02/08 Table 6. P3M1 Register P3M1 Address (D5h) 7 6 5 4 3 2 1 0 P3M1.7 P3M1.6 P3M1.5 P3M1.4 P3M1.3 P3M1.2 P3M1.1 P3M1.0 Bit Number Bit Mnemonic 0-7 P3M1.x Description Port Output configuration bit See Table 2 for configuration definition Reset Value = 0000 0000 Table 7. P3M2 Register P3M2 Address (E4h) 7 6 5 4 3 2 1 0 P3M2.7 P3M2.6 P3M2.5 P3M2.4 P3M2.3 P3M2.2 P3M2.1 P3M2.0 Bit Number Bit Mnemonic Description 0-7 P3M2.x Port Output configuration bit See Table 2 for configuration definition Reset Value = 0000 0000 15 4134D–8051–02/08 Dual-data Pointer Register (DPTR) The additional data pointer can be used to speed up code execution and reduce code size in a number of ways. The dual DPTR structure is a way by which the device will specify the address of an external data memory location. There are two 16-bit DPTR registers that address the external memory, and a single bit called DPS = AUXR1/bit0 (see Table 8) that allows the program code to switch between them (Refer to Figure 7). Figure 7. Use of Dual-data Pointer External Data Memory 7 0 DPS DPTR1 DPTR0 AUXR1(A2H) DPH(83H) DPL(82H) Table 8. AUXR1: Auxiliary Register 1 7 6 5 4 3 2 1 0 - - - - - 0 - DPS Bit Number Bit Mnemonic Description 7-3 - Reserved(1) The value read from this bit is indeterminate. Do not set this bit. 2 0 always stuck at 0 1 - Reserved The value read from this bit is indeterminate. Do not set this bit. 0 DPS Data Pointer Selection Clear to select DPTR0. Set to select DPTR1. Reset Value = XXXX X0X0 Note: 1. User software should not write 1s to reserved bits. These bits may be used in future 8051 family products to invoke new features. In that case, the reset value of the new bit will be 0, and its active value will be 1. The value read from a reserved bit is indeterminate. 16 4134D–8051–02/08 Application Software can take advantage of the additional data pointers to both increase speed and reduce code size, for example, block operations (copy, compare, search...) are well served by using one data pointer as a ’source’ pointer and the other one as a "destination" pointer. ASSEMBLY LANGUAGE ; Block move using dual data pointers ; Destroys DPTR0, DPTR1, A and PSW ; note: DPS exits opposite of entry state ; unless an extra INC AUXR1 is added ; 00A2 AUXR1 EQU 0A2H ; 0000 909000MOV DPTR,#SOURCE ; address of SOURCE 0003 05A2 INC AUXR1 ; switch data pointers 0005 90A000 MOV DPTR,#DEST ; address of DEST 0008 LOOP: 0008 05A2 INC AUXR1 ; switch data pointers 000A E0 MOVX A,@DPTR ; get a byte from SOURCE 000B A3 INC DPTR ; increment SOURCE address 000C 05A2 INC AUXR1 ; switch data pointers 000E F0 MOVX @DPTR,A ; write the byte to DEST 000F A3 INC DPTR ; increment DEST address 0010 70F6JNZ LOOP ; check for 0 terminator 0012 05A2 INC AUXR1 ; (optional) restore DPS INC is a short (2 bytes) and fast (12 clocks) way to manipulate the DPS bit in the AUXR1 SFR. However, note that the INC instruction does not directly force the DPS bit to a particular state, but simply toggles it. In simple routines, such as the block move example, only the fact that DPS is toggled in the proper sequence matters, not its actual value. In other words, the block move routine works the same whether DPS is “0” or “1” on entry. Observe that without the last instruction (INC AUXR1), the routine will exit with DPS in the opposite state. 17 4134D–8051–02/08 Serial Port Interface (SPI) The Serial Peripheral Interface module (SPI) which allows full-duplex, synchronous, serial communication between the MCU and peripheral devices, including other MCUs. Features Features of the SPI module include the following: Signal Description • Full-duplex, three-wire synchronous transfers • Master or Slave operation • Eight programmable Master clock rates • Serial clock with programmable polarity and phase • Master Mode fault error flag with MCU interrupt capability • Write collision flag protection Figure 8 shows a typical SPI Bus configuration using one Master controller and many Slave peripherals. The bus is made of three wires connecting all the devices. Figure 8. Typical SPI Bus Slave 1 MISO MOSI SCK SS MISO MOSI SCK SS VDD Slave 4 Slave 3 MISO MOSI SCK SS MISO MOSI SCK SS 0 1 2 3 MISO MOSI SCK SS PORT Master Slave 2 The Master device selects the individual Slave devices by using four pins of a parallel port to control the four SS pins of the Slave devices. Master Output Slave Input (MOSI) This 1-bit signal is directly connected between the Master device and a Slave device. The MOSI line is used to transfer data in series from the Master to the Slave. Therefore, it is an output signal from the Master, and an input signal to a Slave. A byte (8-bit word) is transmitted most significant bit (MSB) first, least significant bit (LSB) last. Master Input Slave Output (MISO) This 1-bit signal is directly connected between the Slave device and a Master device. The MISO line is used to transfer data in series from the Slave to the Master. Therefore, it is an output signal from the Slave, and an input signal to the Master. A byte (8-bit word) is transmitted most significant bit (MSB) first, least significant bit (LSB) last. SPI Serial Clock (SCK) This signal is used to synchronize the data movement both in and out the devices through their MOSI and MISO lines. It is driven by the Master for eight clock cycles which allows to exchange one byte on the serial lines. 18 4134D–8051–02/08 Slave Select (SS) Each Slave peripheral is selected by one Slave Select pin (SS). This signal must stay low for any message for a Slave. It is obvious that only one Master (SS high level) can drive the network. The Master may select each Slave device by software through port pins (Figure 8). To prevent bus conflicts on the MISO line, only one slave should be selected at a time by the Master for a transmission. In a Master configuration, the SS line can be used in conjunction with the MODF flag in the SPI Status register (SPSTA) to prevent multiple masters from driving MOSI and SCK (See Error Conditions). A high level on the SS pin puts the MISO line of a Slave SPI in a high-impedance state. The SS pin could be used as a general purpose if the following conditions are met: Baud Rate • The device is configured as a Master and the SSDIS control bit in SPCON is set. This kind of configuration can be found when only one Master is driving the network and there is no way that the SS pin will be pulled low. Therefore, the MODF flag in the SPSTA will never be set (1). • The Device is configured as a Slave with CPHA and SSDIS control bits set (2). This kind of configuration can happen when the system comprises one Master and one Slave only. Therefore, the device should always be selected and there is no reason that the Master uses the SS pin to select the communicating Slave device. In Master Mode, the baud rate can be selected from a baud rate generator which is controlled by three bits in the SPCON register: SPR2, SPR1 and SPR0. The Master clock is chosen from one of six clock rates resulting from the division of the internal clock by 4, 8, 16, 32, 64 or 128. Table 9 gives the different clock rates selected by SPR2:SPR1:SPR0: Table 9. SPI Master Baud Rate Selection SPR2:SPR1:SPR0 Clock Rate Baud Rate Divisor (BD) 000 Don’t Use No BRG 001 FCLK_PERIPH /4 4 010 FCLK_PERIPH/8 8 011 FCLK_PERIPH /16 16 100 FCLK_PERIPH /32 32 101 FCLK_PERIPH /64 64 110 FCLK_PERIPH /128 128 111 Don’t Use No BRG 1. Clearing SSDIS control bit does not clear MODF. 2. Special care should be taken not to set SSDIS control bit when CPHA = “0” because in this mode, the SS is used to start the transmission. 19 4134D–8051–02/08 Functional Description Figure 9 shows a detailed structure of the SPI module. Figure 9. SPI Module Block Diagram Internal Bus SPDAT Shift Register IntClk Clock Divider 7 /4 /8 /16 /32 /64 /128 6 5 4 3 2 1 0 Receive Data Register Pin Control Logic Clock Logic MOSI MISO M S Clock Select SCK SS SPR2 SPEN SSDIS MSTR CPOL CPHA SPR1 SPR0 SPCON SPI Interrupt Request SPI Control 8-bit bus 1-bit signal SPSTA SPIF WCOL Operating Modes - MODF - - - - The Serial Peripheral Interface can be configured as one of the two modes: Master Mode or Slave Mode. The configuration and initialization of the SPI module is made through one register: • The Serial Peripheral Control register (SPCON) Once the SPI is configured, the data exchange is made using: • SPCON • The Serial Peripheral Status register (SPSTA) • The Serial Peripheral Data register (SPDAT) During an SPI transmission, data is simultaneously transmitted (shifted out serially) and received (shifted in serially). A serial clock line (SCK) synchronizes shifting and sampling on the two serial data lines (MOSI and MISO). A Slave Select line (SS) allows individual selection of a Slave SPI device; Slave devices that are not selected do not interfere with SPI bus activities. When the Master device transmits data to the Slave device via the MOSI line, the Slave device responds by sending data to the Master device via the MISO line. This implies full-duplex transmission with both data out and data in synchronized with the same clock (Figure 10). 20 4134D–8051–02/08 Figure 10. Full-Duplex Master-Slave Interconnection 8-bit Shift Register SPI Clock Generator MISO MISO MOSI MOSI SCK SS Master MCU Master Mode 8-bit Shift Register SCK VDD SS VSS Slave MCU The SPI operates in Master Mode when the Master bit, MSTR (1), in the SPCON register is set. Only one Master SPI device can initiate transmissions. Software begins the transmission from a Master SPI module by writing to the Serial Peripheral Data Register (SPDAT). If the shift register is empty, the byte is immediately transferred to the shift register. The byte begins shifting out on MOSI pin under the control of the serial clock, SCK. Simultaneously, another byte shifts in from the Slave on the Master’s MISO pin. The transmission ends when the Serial Peripheral transfer data flag, SPIF, in SPSTA becomes set. At the same time that SPIF becomes set, the received byte from the Slave is transferred to the receive data register in SPDAT. Software clears SPIF by reading the Serial Peripheral Status register (SPSTA) with the SPIF bit set, and then reading the SPDAT. When the pin SS is pulled down during a transmission, the data is interrupted and when the transmission is established again, the data present in the SPDAT is resent. Slave Mode The SPI operates in Slave Mode when the Master bit, MSTR (2), in the SPCON register is cleared. Before a data transmission occurs, the Slave Select pin, SS, of the Slave device must be set to “0”. SS must remain low until the transmission is complete. In a Slave SPI module, data enters the shift register under the control of the SCK from the Master SPI module. After a byte enters the shift register, it is immediately transferred to the receive data register in SPDAT, and the SPIF bit is set. To prevent an overflow condition, Slave software must then read the SPDAT before another byte enters the shift register (3). A Slave SPI must complete the write to the SPDAT (shift register) at least one bus cycle before the Master SPI starts a transmission. If the write to the data register is late, the SPI transmits the data already in the shift register from the previous transmission. Transmission Formats Software can select any of four combinations of serial clock (SCK) phase and polarity using two bits in the SPCON: the Clock POLarity (CPOL (4) ) and the Clock PHAse (CPHA(4)). CPOL defines the default SCK line level in idle state. It has no significant effect on the transmission format. CPHA defines the edges on which the input data are sampled and the edges on which the output data are shifted (Figure 11 and Figure 12). The clock phase and polarity should be identical for the Master SPI device and the communicating Slave device. 1. The SPI module should be configured as a Master before it is enabled (SPEN set). Also the Master SPI should be configured before the Slave SPI. 2. The SPI module should be configured as a Slave before it is enabled (SPEN set). 3. The maximum frequency of the SCK for an SPI configured as a Slave is the bus clock speed. 4. Before writing to the CPOL and CPHA bits, the SPI should be disabled (SPEN = "0"). 21 4134D–8051–02/08 Figure 11. Data Transmission Format (CPHA = 0) 1 2 3 4 5 6 7 8 MSB bit6 bit5 bit4 bit3 bit2 bit1 LSB bit6 bit5 bit4 bit3 bit2 bit1 LSB SCK Cycle Number SPEN (Internal) SCK (CPOL = 0) SCK (CPOL = 1) MOSI (from Master) MISO (from Slave) MSB SS (to Slave) Capture Point Figure 12. Data Transmission Format (CPHA = 1) 1 2 3 4 5 6 7 8 MOSI (from Master) MSB bit6 bit5 bit4 bit3 bit2 bit1 LSB MISO (from Slave) MSB bit6 bit5 bit4 bit3 bit2 bit1 SCK Cycle Number SPEN (Internal) SCK (CPOL = 0) SCK (CPOL = 1) LSB SS (to Slave) Capture Point As shown in Figure 11, the first SCK edge is the MSB capture strobe. Therefore, the Slave must begin driving its data before the first SCK edge, and a falling edge on the SS pin is used to start the transmission. The SS pin must be toggled high and then low between each byte transmitted (Figure 13). Figure 13. CPHA/SS Timing MISO/MOSI Byte 1 Byte 2 Byte 3 Master SS Slave SS (CPHA = 0) Slave SS (CPHA = 1) Figure 12 shows an SPI transmission in which CPHA is “1”. In this case, the Master begins driving its MOSI pin on the first SCK edge. Therefore the Slave uses the first SCK edge as a start transmission signal. The SS pin can remain low between transmissions (Figure 13). This format may be preferable in systems having only one Master and only one Slave driving the MISO data line. 22 4134D–8051–02/08 Error Conditions The following flags in the SPSTA signal SPI error conditions. Mode Fault (MODF) Mode Fault error in Master Mode SPI indicates that the level on the Slave Select (SS) pin is inconsistent with the actual mode of the device. MODF is set to warn that there may have a multi-master conflict for system control. In this case, the SPI system is affected in the following ways: • An SPI receiver/error CPU interrupt request is generated. • The SPEN bit in SPCON is cleared. This disable the SPI. • The MSTR bit in SPCON is cleared. When SS DISable (SSDIS) bit in the SPCON register is cleared, the MODF flag is set when the SS signal becomes “0”. However, as stated before, for a system with one Master, if the SS pin of the Master device is pulled low, there is no way that another Master is attempting to drive the network. In this case, to prevent the MODF flag from being set, software can set the SSDIS bit in the SPCON register and therefore making the SS pin as a general-purpose I/O pin. Clearing the MODF bit is accomplished by a read of SPSTA register with MODF bit set, followed by a write to the SPCON register. SPEN Control bit may be restored to its original set state after the MODF bit has been cleared. Write Collision (WCOL) A Write Collision (WCOL) flag in the SPSTA is set when a write to the SPDAT register is done during a transmit sequence. WCOL does not cause an interruption, and the transfer continues uninterrupted. Clearing the WCOL bit is done through a software sequence of an access to SPSTA and an access to SPDAT. Overrun Condition An overrun condition occurs when the Master device tries to send several data bytes and the Slave device has not cleared the SPIF bit issuing from the previous data byte transmitted. In this case, the receiver buffer contains the byte sent after the SPIF bit was last cleared. A read of the SPDAT returns this byte. All others bytes are lost. This condition is not detected by the SPI peripheral. SS Error Flag (SSERR) A Synchronous Serial Slave Error occurs when SS goes high before the end of a received data in Slave Mode. SSERR does not cause in interruption, this bit is cleared by writing 0 to SPEN bit (reset of the SPI state machine). Interrupts Two SPI status flags can generate a CPU interrupt requests (See Table 10) Table 10. SPI Interrupts Flag Request SPIF (SP data transfer) SPI Transmitter Interrupt request MODF (Mode Fault) SPI Receiver/Error Interrupt Request (if SSDIS = "0") Serial Peripheral data transfer flag, SPIF: This bit is set by hardware when a transfer has been completed. SPIF bit generates transmitter CPU interrupt requests. Mode Fault flag, MODF: This bit becomes set to indicate that the level on the SS is inconsistent with the mode of the SPI. MODF with SSDIS reset, generates receiver/error CPU interrupt requests. Figure 14 gives a logical view of the above statements. 23 4134D–8051–02/08 Figure 14. SPI Interrupt Requests Generation SPIF SPI Transmitter CPU Interrupt Request MODF SPI CPU Interrupt Request SPI Receiver/Error CPU Interrupt Request SSDIS Registers There are three registers in the module that provide control, status and data storage functions. These registers are describes in the following paragraphs. Serial Peripheral Control Register (SPCON) The Serial Peripheral Control Register does the following: • Selects one of the Master clock rates • Configure the SPI module as Master or Slave • Selects serial clock polarity and phase • Enables the SPI module • Frees the SS pin for a general purpose Table 11 describes this register and explains the use of each bit. Table 11. SPCON Register: Serial Peripheral Control Register - SPCON (S:C3h) 7 6 5 4 3 2 1 0 SPR2 SPEN SSDIS MSTR CPOL CPHA SPR1 SPR0 Bit Number Bit Mnemonic 7 SPR2 R/W 6 SPEN R/W R/W Mode Description Serial Peripheral Rate 2 Bit with SPR1 and SPR0 define the clock rate Serial Peripheral Enable Clear to disable the SPI interface (internal reset of the SPI) Set to enable the SPI interface SS Disable 5 SSDIS R/W Clear to enable SS in both Master and Slave Modes Set to disable SS in both Master and Slave Modes. In Slave Mode, this bit has no effect if CPHA = "0" Serial Peripheral Master 4 MSTR R/W Clear to configure the SPI as a Slave Set to configure the SPI as a Master Clock Polarity 3 CPOL R/W Clear to have the SCK set to ‘0’ in idle state Set to have the SCK set to ’1’ in idle low Clock Phase 2 CPHA R/W Clear to have the data sampled when the SPSCK leaves the idle state (see CPOL) Set to have the data sampled when the SPSCK returns to idle state (see CPOL) Serial Peripheral Rate (SPR2:SPR1:SPR0) 000: N.A. 1 SPR1 R/W 001: FCLK PERIPH /4 010: FCLK PERIPH /8 011: FCLK PERIPH /16 24 4134D–8051–02/08 Bit Number Bit Mnemonic R/W Mode Description 100: FCLK PERIPH /32 0 SPR0 101: FCLK PERIPH /64 R/W 110: FCLK PERIPH /128 111: Don’t Use Reset Value = 00010100b Serial Peripheral Status Register (SPSTA) The Serial Peripheral Status Register contains flags to signal the following conditions: • Data transfer complete • Write collision • Inconsistent logic level on SS pin (mode fault error) Table 12 describes the SPSTA register and explains the use of every bit in the register. Table 12. SPSTA: Serial Peripheral Status and Control Register - SPSTA (S:C4h) 7 6 5 4 3 2 1 0 SPIF WCOL SSERR MODF - - - - Bit Number Bit Mnemonic R/W Mode Description Serial Peripheral Data Transfer Flag 7 SPIF R Clear by hardware to indicate data transfer is in progress or has been approved by a clearing sequence. Set by hardware to indicate that the data transfer has been completed. Write Collision Flag 6 WCOL R Cleared by hardware to indicate that no collision has occurred or has been approved by a clearing sequence. Set by hardware to indicate that a collision has been detected. Synchronous Serial Slave Error Flag 5 SSERR R Set by hardware when SS is deasserted before the end of a received data. Cleared by disabling the SPI (clearing SPEN bit in SPCON). Mode Fault 4 MODF R Cleared by hardware to indicate that the SS pin is at appropriate logic level, or has been approved by a clearing sequence. Set by hardware to indicate that the SS pin is at inappropriate logic level 3 - R/W Reserved The value read from this bit is indeterminate. Do not set this bit. 2 - R/W Reserved The value read from this bit is indeterminate. Do not set this bit. 1 - R/W Reserved The value read from this bit is indeterminate. Do not set this bit. 0 - R/W Reserved The value read from this bit is indeterminate. Do not set this bit. Reset Value = 00X0XXXXb 25 4134D–8051–02/08 Serial Peripheral Data Register (SPDAT) The Serial Peripheral Data Register (Table 13) is a read/write buffer for the receive data register. A write to SPDAT places data directly into the shift register. No transmit buffer is available in this model. A Read of the SPDAT returns the value located in the receive buffer and not the content of the shift register. Table 13. SPDAT (S:C5h): Serial Peripheral Data Register 7 6 5 4 3 2 1 0 R7 R6 R5 R4 R3 R2 R1 R0 Reset Value = XXXX XXXXb R7:R0: Receive data bits SPCON, SPSTA and SPDAT registers may be read and written at any time while there is no on-going exchange. However, special care should be taken when writing to them while a transmission is on-going: • Do not change SPR2, SPR1 and SPR0 • Do not change CPHA and CPOL • Do not change MSTR • Clearing SPEN would immediately disable the peripheral • Writing to the SPDAT will cause an overflow 26 4134D–8051–02/08 Timers/Counters The Errata Sheet implements two general-purpose, 16-bit Timers/Counters. They are identified as Timer 0 and Timer 1, and can be independently configured to operate in a variety of modes as a Timer or as an event Counter. When operating as a Timer, the Timer/Counter runs for a programmed length of time, then issues an interrupt request. When operating as a Counter, the Timer/Counter counts negative transitions on an external pin. After a preset number of counts, the Counter issues an interrupt request. The various operating modes of each Timer/Counter are described in the following sections. Timer/Counter Operations For instance, a basic operation is Timer registers THx and TLx (x = 0, 1) connected in cascade to form a 16-bit Timer. Setting the run control bit (TRx) in TCON register (see Figure 14) turns the Timer on by allowing the selected input to increment TLx. When TLx overflows it increments THx; when THx overflows it sets the Timer overflow flag (TFx) in TCON register. Setting the TRx does not clear the THx and TLx Timer registers. Timer registers can be accessed to obtain the current count or to enter preset values. They can be read at any time but TRx bit must be cleared to preset their values, other/wise the behavior of the Timer/Counter is unpredictable. The C/Tx# control bit selects Timer operation or Counter operation by selecting the divided-down peripheral clock or external pin Tx as the source for the counted signal. TRx bit must be cleared when changing the mode of operation, other/wise the behavior of the Timer/Counter is unpredictable. For Timer operation (C/Tx# = 0), the Timer register counts the divided-down peripheral clock. The Timer register is incremented once every peripheral cycle (6 peripheral clock periods). The Timer clock rate is FPER/6, i.e. FOSC/12 in standard mode or FOSC/6 in X2 Mode. For Counter operation (C/Tx# = 1), the Timer register counts the negative transitions on the Tx external input pin. The external input is sampled every peripheral cycles. When the sample is high in one cycle and low in the next one, the Counter is incremented. Since it takes 2 cycles (12 peripheral clock periods) to recognize a negative transition, the maximum count rate is FPER/12, i.e. FOSC/24 in standard mode or FOSC/12 in X2 Mode. There are no restrictions on the duty cycle of the external input signal, but to ensure that a given level is sampled at least once before it changes, it should be held for at least one full peripheral cycle. Timer 0 Timer 0 functions as either a Timer or event Counter in four modes of operation. Figure 15 through Figure 18 show the logical configuration of each mode. Timer 0 is controlled by the four lower bits of TMOD register (See Figure 15) and bits 0, 1, 4 and 5 of TCON register (see Figure 14). TMOD register selects the method of Timer gating (GATE0), Timer or Counter operation (T/C0#) and mode of operation (M10 and M00). TCON register provides Timer 0 control functions: overflow flag (TF0), run control bit (TR0), interrupt flag (IE0) and interrupt type control bit (IT0). For normal Timer operation (GATE0 = 0), setting TR0 allows TL0 to be incremented by the selected input. Setting GATE0 and TR0 allows external pin INT0# to control Timer operation. Timer 0 overflow (count rolls over from all 1s to all 0s) sets TF0 flag generating an interrupt request. It is important to stop Timer/Counter before changing mode. 27 4134D–8051–02/08 Mode 0 (13-bit Timer) Mode 0 configures Timer 0 as an 13-bit Timer which is set up as an 8-bit Timer (TH0 register) with a modulo 32 prescaler implemented with the lower five bits of TL0 register (see Figure 15). The upper three bits of TL0 register are indeterminate and should be ignored. Prescaler overflow increments TH0 register. Figure 15. Timer/Counter x (x = 0 or 1) in Mode 0 PERIPH CLOCK ÷6 0 THx (8 Bits) 1 TLx (5 Bits) Overflow TFx TCON Reg Tx Timer x Interrupt Request C/Tx# TMOD Reg INTx# GATEx TRx TMOD Reg TCON Reg Mode 1 (16-bit Timer) Mode 1 configures Timer 0 as a 16-bit Timer with TH0 and TL0 registers connected in cascade (see Figure 16). The selected input increments TL0 register. Figure 16. Timer/Counter x (x = 0 or 1) in Mode 1 PERIPH CLOCK ÷6 0 THx (8 Bits) 1 TLx (8 Bits) Overflow TFx TCON Reg Tx Timer x Interrupt Request C/Tx# TMOD Reg INTx# GATEx TRx TMOD Reg TCON Reg Mode 2 (8-bit Timer with AutoReload) Mode 2 configures Timer 0 as an 8-bit Timer (TL0 register) that automatically reloads from TH0 register (see Figure 17). TL0 overflow sets TF0 flag in TCON register and reloads TL0 with the contents of TH0, which is preset by software. When the interrupt request is serviced, hardware clears TF0. The reload leaves TH0 unchanged. The next reload value may be changed at any time by writing it to TH0 register. Figure 17. Timer/Counter x (x = 0 or 1) in Mode 2 PERIPH CLOCK ÷6 0 TLx (8 Bits) 1 Tx Overflow TFx TCON Reg Timer x Interrupt Request C/Tx# TMOD Reg INTx# GATEx TMOD Reg TRx THx (8 Bits) TCON Reg 28 4134D–8051–02/08 Mode 3 (Two 8-bit Timers) Mode 3 configures Timer 0 such that registers TL0 and TH0 operate as separate 8-bit Timers (see Figure 18). This mode is provided for applications requiring an additional 8bit Timer or Counter. TL0 uses the Timer 0 control bits C/T0# and GATE0 in TMOD register, and TR0 and TF0 in TCON register in the normal manner. TH0 is locked into a Timer function (counting FPER /6) and takes over use of the Timer 1 interrupt (TF1) and run control (TR1) bits. Thus, operation of Timer 1 is restricted when Timer 0 is in Mode 3. Figure 18. Timer/Counter 0 in Mode 3: Two 8-bit Counters PERIPH CLOCK ÷6 0 1 TL0 (8 Bits) Overflow TH0 (8 Bits) Overflow TF0 TCON.5 T0 Timer 0 Interrupt Request C/T0# TMOD.2 INT0# GATE0 TR0 TMOD.3 PERIPH CLOCK TCON.4 ÷6 TF1 TCON.7 Timer 1 Interrupt Request TR1 TCON.6 Timer 1 Timer 1 is identical to Timer 0 excepted for Mode 3 which is a hold-count mode. The following comments help to understand the differences: • Timer 1 functions as either a Timer or event Counter in three modes of operation. Figure 15 through Figure 17 show the logical configuration for modes 0, 1, and 2. Timer 1’s Mode 3 is a hold-count mode. • Timer 1 is controlled by the four high-order bits of TMOD register (see Figure 15) and bits 2, 3, 6 and 7 of TCON register (see Figure 14). TMOD register selects the method of Timer gating (GATE1), Timer or Counter operation (C/T1#) and mode of operation (M11 and M01). TCON register provides Timer 1 control functions: overflow flag (TF1), run control bit (TR1), interrupt flag (IE1) and interrupt type control bit (IT1). • Timer 1 can serve as the Baud Rate Generator for the Serial Port. Mode 2 is best suited for this purpose. • For normal Timer operation (GATE1 = 0), setting TR1 allows TL1 to be incremented by the selected input. Setting GATE1 and TR1 allows external pin INT1# to control Timer operation. • Timer 1 overflow (count rolls over from all 1s to all 0s) sets the TF1 flag generating an interrupt request. • When Timer 0 is in Mode 3, it uses Timer 1’s overflow flag (TF1) and run control bit (TR1). For this situation, use Timer 1 only for applications that do not require an interrupt (such as a Baud Rate Generator for the Serial Port) and switch Timer 1 in and out of Mode 3 to turn it off and on. • It is important to stop Timer/Counter before changing mode. 29 4134D–8051–02/08 Mode 0 (13-bit Timer) Mode 0 configures Timer 1 as a 13-bit Timer, which is set up as an 8-bit Timer (TH1 register) with a modulo-32 prescaler implemented with the lower 5 bits of the TL1 register (see Figure 15). The upper 3 bits of TL1 register are ignored. Prescaler overflow increments TH1 register. Mode 1 (16-bit Timer) Mode 1 configures Timer 1 as a 16-bit Timer with TH1 and TL1 registers connected in cascade (see Figure 16). The selected input increments TL1 register. Mode 2 (8-bit Timer with AutoReload) Mode 2 configures Timer 1 as an 8-bit Timer (TL1 register) with automatic reload from TH1 register on overflow (see Figure 17). TL1 overflow sets TF1 flag in TCON register and reloads TL1 with the contents of TH1, which is preset by software. The reload leaves TH1 unchanged. Mode 3 (Halt) Placing Timer 1 in Mode 3 causes it to halt and hold its count. This can be used to halt Timer 1 when TR1 run control bit is not available i.e. when Timer 0 is in Mode 3. Interrupt Each Timer handles one interrupt source that is the timer overflow flag TF0 or TF1. This flag is set every time an overflow occurs. Flags are cleared when vectoring to the Timer interrupt routine. Interrupts are enabled by setting ETx bit in IE0 register. This assumes interrupts are globally enabled by setting EA bit in IE0 register. Figure 19. Timer Interrupt System Timer 0 Interrupt Request TF0 TCON.5 ET0 IE0.1 Timer 1 Interrupt Request TF1 TCON.7 ET1 IE0.3 30 4134D–8051–02/08 Registers Table 14. TCON Register TCON (S:88h) Timer/Counter Control Register 7 6 5 4 3 2 1 0 TF1 TR1 TF0 TR0 IE1 IT1 IE0 IT0 Bit Number Bit Mnemonic Description 7 TF1 Timer 1 Overflow Flag Cleared by hardware when processor vectors to interrupt routine. Set by hardware on Timer/Counter overflow, when Timer 1 register overflows. 6 TR1 Timer 1 Run Control Bit Clear to turn off Timer/Counter 1. Set to turn on Timer/Counter 1. 5 TF0 Timer 0 Overflow Flag Cleared by hardware when processor vectors to interrupt routine. Set by hardware on Timer/Counter overflow, when Timer 0 register overflows. 4 TR0 Timer 0 Run Control Bit Clear to turn off Timer/Counter 0. Set to turn on Timer/Counter 0. 3 IE1 Interrupt 1 Edge Flag Cleared by hardware when interrupt is processed if edge-triggered (see IT1). Set by hardware when external interrupt is detected on INT1# pin. 2 IT1 Interrupt 1 Type Control Bit Clear to select low level active (level triggered) for external interrupt 1 (INT1#). Set to select falling edge active (edge triggered) for external interrupt 1. 1 IE0 Interrupt 0 Edge Flag Cleared by hardware when interrupt is processed if edge-triggered (see IT0). Set by hardware when external interrupt is detected on INT0# pin. 0 IT0 Interrupt 0 Type Control Bit Clear to select low level active (level triggered) for external interrupt 0 (INT0#). Set to select falling edge active (edge triggered) for external interrupt 0. Reset Value = 0000 0000b 31 4134D–8051–02/08 Table 15. TMOD Register TMOD (S:89h) Timer/Counter Mode Control Register 7 6 5 4 3 2 1 0 GATE1 C/T1# M11 M01 GATE0 C/T0# M10 M00 Bit Number Bit Mnemonic Description 7 GATE1 Timer 1 Gating Control Bit Clear to enable Timer 1 whenever TR1 bit is set. Set to enable Timer 1 only while INT1# pin is high and TR1 bit is set. 6 C/T1# Timer 1 Counter/Timer Select Bit Clear for Timer operation: Timer 1 counts the divided-down system clock. Set for Counter operation: Timer 1 counts negative transitions on external pin T1. 5 M11 4 M01 3 GATE0 Timer 0 Gating Control Bit Clear to enable Timer 0 whenever TR0 bit is set. Set to enable Timer/Counter 0 only while INT0# pin is high and TR0 bit is set. 2 C/T0# Timer 0 Counter/Timer Select Bit Clear for Timer operation: Timer 0 counts the divided-down system clock. Set for Counter operation: Timer 0 counts negative transitions on external pin T0. 1 M10 0 M00 Timer 1 Mode Select Bits M11 M01 Operating Mode 0 0 Mode 0: 8-bit Timer/Counter (TH1) with 5-bit prescaler (TL1). 0 1 Mode 1: 16-bit Timer/Counter. 1 0 Mode 2: 8-bit auto-reload Timer/Counter (TL1). Reloaded from TH1 at overflow. 1 1 Mode 3: Timer 1 halted. Retains count. Timer 0 Mode Select Bit M10 M00 Operating Mode 0 0 Mode 0: 8-bit Timer/Counter (TH0) with 5-bit prescaler (TL0). 0 1 Mode 1: 16-bit Timer/Counter. 1 0 Mode 2: 8-bit auto-reload Timer/Counter (TL0). Reloaded from TH0 at overflow. 1 1 Mode 3: TL0 is an 8-bit Timer/Counter. TH0 is an 8-bit Timer using Timer 1’s TR0 and TF0 bits. Reset Value = 0000 0000b Table 16. TH0 Register TH0 (S:8Ch) Timer 0 High Byte Register 7 Bit Number 7:0 6 5 4 3 2 1 0 Bit Mnemonic Description High Byte of Timer 0 Reset Value = 0000 0000b 32 4134D–8051–02/08 Table 17. TL0 Register TL0 (S:8Ah) Timer 0 Low Byte Register 7 6 Bit Number 5 4 3 2 1 0 3 2 1 0 3 2 1 0 Bit Mnemonic Description Low Byte of Timer 0 7:0 Reset Value = 0000 0000b Table 18. TH1 Register TH1 (S:8Dh) Timer 1 High Byte Register 7 6 Bit Number 5 Bit Mnemonic 4 Description High Byte of Timer 1 7:0 Reset Value = 0000 0000b Table 19. TL1 Register TL1 (S:8Bh) Timer 1 Low Byte Register 7 Bit Number 7:0 6 Bit Mnemonic 5 4 Description Low Byte of Timer 1 Reset Value = 0000 0000b 33 4134D–8051–02/08 Power Management Table 20. PCON Register PCON - Power Control Register (87h) 7 6 5 4 3 2 1 0 - - - - GF1 GF0 PD IDL Bit Bit Number Mnemonic 7 - Reserved The value read from this bit is indeterminate. Do not set this bit. 6 - Reserved The value read from this bit is indeterminate. Do not set this bit. 5 - Reserved The value read from this bit is indeterminate. Do not set this bit. 4 - Reserved The value read from this bit is indeterminate. Do not set this bit. 3 GF1 General-purpose Flag Cleared by user for general purpose usage. Set by user for general purpose usage. 2 GF0 General-purpose Flag Cleared by user for general purpose usage. Set by user for general purpose usage. 1 PD Power-Down Mode Bit Cleared by hardware when reset occurs. Set to enter Power-down Mode. 0 IDL Idle Mode Bit Cleared by hardware when interrupt or reset occurs. Set to enter Idle Mode. Description Reset Value = XXX1 0000b Not bit addressable Idle Mode An instruction that sets PCON.0 indicates that it is the last instruction to be executed before going into the Idle Mode. In the Idle Mode, the internal clock signal is gated off to the CPU, but not to the interrupt, Timer, and Serial Port functions. The CPU status is preserved in its entirety: the Stack Pointer, Program Counter, Program Status Word, Accumulator and all other registers maintain their data during Idle. The port pins hold the logical states they had at the time Idle was activated. There are two ways to terminate the Idle Mode. Activation of any enabled interrupt will cause PCON.0 to be cleared by hardware, terminating the Idle Mode. The interrupt will be serviced, and following RETI the next instruction to be executed will be the one following the instruction that put the device into idle. The flag bits GF0 and GF1 can be used to give an indication if an interrupt occurred during normal operation or during an Idle. For example, an instruction that activates Idle can also set one or both flag bits. When Idle is terminated by an interrupt, the interrupt service routine can examine the flag bits. The other way of terminating the Idle Mode is with a hardware reset. Since the clock oscillator is still running, the hardware reset needs to be held active for only two machine cycles (24 oscillator periods) to complete the reset. 34 4134D–8051–02/08 Power-down Mode To save maximum power, a power-down mode can be invoked by software (refer to Table 20, PCON register). In power-down mode, the oscillator is stopped and the instruction that invoked powerdown mode is the last instruction executed. The internal RAM and SFRs retain their value until the power-down mode is terminated. VCC can be lowered to save further power. Either a hardware reset or an external interrupt can cause an exit from powerdown. To properly terminate power-down mode, the reset or external interrupt should not be executed before VCC is restored to its normal operating level and must be held active long enough for the oscillator to restart and stabilize. Only external interrupts INT0, INT1 are useful for exiting from power-down. For that, interrupt must be enabled and configured as level or edge sensitive interrupt input. Holding the pin low restarts the oscillator but bringing the pin high completes the exit as detailed in Figure 20. When both interrupts are enabled, the oscillator restarts as soon as one of the two inputs is held low and power-down exit will be completed when the first input is released. In this case the higher priority interrupt service routine is executed. Once the interrupt is serviced, the next instruction to be executed after RETI will be the one following the instruction that put AT8xC5103 into power-down mode. Figure 20. Power-Down Exit Waveform INT0 INT1 XTALA or XTALB Active Phase Power-down Phase Oscillator Restart Phase Active Phase Exiting from power-down by reset redefines all the SFRs, exiting from power-down by external interrupt does no affect the SFRs. Exiting from power-down by either reset or external interrupt does not affect the internal RAM content. Note: If idle mode is activated with power-down mode (IDL and PD bits set), the exit sequence is unchanged, when execution is vectored to interrupt, PD and IDL bits are cleared and idle mode is not entered. Table 21 shows the state of ports during idle and power-down modes. Table 21. State of Ports(1) Note: Mode Program Memory PORT1 PORT3 Idle Internal Port Data Port Data Power-down Internal Port Data Port Data 1. Port 0 can force a 0 level. A ‘one’ will leave port floating. 35 4134D–8051–02/08 Programmable Counter Array (PCA) The PCA provides more timing capabilities with less CPU intervention than the standard timer/counters. Its advantages include reduced software overhead and improved accuracy. The PCA consists of a dedicated timer/counter which serves as the time base for an array of five compare/capture modules. Its clock input can be programmed to count any one of the following signals: • Oscillator frequency ÷ 12 (÷ 6 in X2 Mode) • Oscillator frequency ÷ 4 (÷ 2 in X2 Mode) • Timer 0 overflow • External input on ECI (P1.2) Each compare/capture modules can be programmed in any one of the following modes: • Rising and/or falling edge capture, • Software timer • High-speed output • Pulse width modulator Module 4 can also be programmed as a watchdog timer. When the compare/capture modules are programmed in the capture mode, software timer, or high speed output mode, an interrupt can be generated when the module executes its function. All five modules and the PCA timer overflow share one interrupt vector. The PCA timer/counter and compare/capture modules share Port 1 for external I/O. These pins are listed below. If the port is not used for the PCA, it can still be used for standard I/O. PCA Component External I/O Pin 16-bit Counter P1.2/ECI 16-bit Module 0 P1.3/CEX0 16-bit Module 1 P1.4/CEX1 16-bit Module 2 P1.5/CEX2 16-bit Module 3 P1.6/CEX3 16-bit Module 4 P1.7/CEX4 The PCA timer is a common time base for all five modules (See Figure 21). The timer count source is determined from the CPS1 and CPS0 bits in the CMOD SFR (see Table 21) and can be programmed to run at: • 1/12 the oscillator frequency (or 1/6 in X2 Mode) • 1/4 the oscillator frequency (or 1/2 in X2 Mode) • The Timer 0 overflow • The input on the ECI pin (P1.2) 36 4134D–8051–02/08 PCA Timer Figure 21. PCA Timer/Counter To PCA Modules Fosc/12 Overflow Fosc/4 CH T0 OVF It CL 16-bit Up/Down Counter P1.2 CIDL WDTE CF CR CPS1 CPS0 ECF CMOD 0xD9 CCF2 CCF1 CCF0 CCON 0xD8 Idle CCF4 CCF3 Table 22. CMOD: PCA Counter Mode Register CMOD Address 0D9H Reset value Symbol CIDL WDTE - WDTE - - - CPS1 CPS0 ECF 0 0 X X X 0 0 0 Function Counter Idle control: CIDL = 0 programs the PCA Counter to continue functioning during idle Mode. CIDL = 1 programs it to be gated off during idle. Watchdog Timer Enable: WDTE = 0 disables Watchdog Timer function on PCA Module 4. WDTE = 1 enables it. Not implemented, reserved for future use. (1) CPS1 PCA Count Pulse Select bit 1. CPS0 PCA Count Pulse Select bit 0. ECF CIDL Selected PCA input. (2) CPS1 CPS0 0 0 Internal clock fosc/12 (Or fosc/6 in X2 Mode). 0 1 Internal clock fosc/4 (Or fosc/2 in X2 Mode). 1 0 Timer 0 Overflow 1 1 External clock at ECI/P1.2 pin (max rate = fosc/ 8) PCA Enable Counter Overflow interrupt: ECF = 1 enables CF bit in CCON to generate an interrupt. ECF = 0 disables that function of CF. 1. User software should not write 1s to reserved bits. These bits may be used in future 8051 family products to invoke new features. In that case, the reset or inactive value of the new bit will be 0, and its active value will be 1. The value read from a reserved bit is indeterminate. 2. fosc = oscillator frequency 37 4134D–8051–02/08 The CMOD SFR includes three additional bits associated with the PCA (See Figure 21 and Table 21). • The CIDL bit which allows the PCA to stop during idle mode. • The WDTE bit which enables or disables the watchdog function on module 4. • The ECF bit which when set causes an interrupt and the PCA overflow flag CF (in the CCON SFR) to be set when the PCA timer overflows. The CCON SFR contains the run control bit for the PCA and the flags for the PCA timer (CF) and each module (Refer to Table 23). • Bit CR (CCON.6) must be set by software to run the PCA. The PCA is shut off by clearing this bit. • Bit CF: The CF bit (CCON.7) is set when the PCA counter overflows and an interrupt will be generated if the ECF bit in the CMOD register is set. The CF bit can only be cleared by software. • Bits 0 through 4 are the flags for the modules (bit 0 for module 0, bit 1 for module 1, etc.) and are set by hardware when either a match or a capture occurs. These flags also can only be cleared by software. • Table 23. CCON: PCA Counter Control Register CCON Address 0D8H Reset Value Symbol CR - CCF4 CCF3 CCF2 CCF1 CCF0 0 0 X 0 0 0 0 0 Function CF PCA Counter Overflow flag. Set by hardware when the counter rolls over. CF flags an interrupt if bit ECF in CMOD is set. CF may be set by either hardware or software but can only be cleared by software. CR PCA Counter Run control bit. Set by software to turn the PCA counter on. Must be cleared by software to turn the PCA counter off. Not implemented, reserved for future use. (1) - 1. CF CCF4 PCA Module 4 interrupt flag. Set by hardware when a match or capture occurs. Must be cleared by software. CCF3 PCA Module 3 interrupt flag. Set by hardware when a match or capture occurs. Must be cleared by software. CCF2 PCA Module 2 interrupt flag. Set by hardware when a match or capture occurs. Must be cleared by software. CCF1 PCA Module 1 interrupt flag. Set by hardware when a match or capture occurs. Must be cleared by software. CCF0 PCA Module 0 interrupt flag. Set by hardware when a match or capture occurs. Must be cleared by software. User software should not write 1s to reserved bits. These bits may be used in future 8051 family products to invoke new features. In that case, the reset or inactive value of the new bit will be 0, and its active value will be 1. The value read from a reserved bit is indeterminate. The watchdog timer function is implemented in module 4 (See Figure 24). The PCA interrupt system is shown in Figure 22. 38 4134D–8051–02/08 Figure 22. PCA Interrupt System CF CR CCF4 CCF3 CCF2 CCF1 CCF0 CCON 0xD8 PCA Timer/Counter Module 0 Module 1 To Interrupt Priority Decoder Module 2 Module 3 Module 4 CMOD.0 ECF ECCFn CCAPMn.0 IE.6 EC IE.7 EA PCA Modules: each one of the five compare/capture modules has six possible functions. It can perform: • 16-bit Capture, positive-edge triggered • 16-bit Capture, negative-edge triggered • 16-bit Capture, both positive and negative-edge triggered • 16-bit Software Timer • 16-bit High Speed Output • 8-bit Pulse Width Modulator In addition, module 4 can be used as a Watchdog Timer. Each module in the PCA has a special function register associated with it. These registers are: CCAPM0 for module 0, CCAPM1 for module 1, etc. (See Table 24). The registers contain the bits that control the mode that each module will operate in. • The ECCF bit (CCAPMn.0 where n = 0, 1, 2, 3, or 4 depending on the module) enables the CCF flag in the CCON SFR to generate an interrupt when a match or compare occurs in the associated module. • PWM (CCAPMn.1) enables the pulse width modulation mode. • The TOG bit (CCAPMn.2) when set causes the CEX output associated with the module to toggle when there is a match between the PCA counter and the module's capture/compare register. • The match bit MAT (CCAPMn.3) when set will cause the CCFn bit in the CCON register to be set when there is a match between the PCA counter and the module's capture/compare register. • The next two bits CAPN (CCAPMn.4) and CAPP (CCAPMn.5) determine the edge that a capture input will be active on. The CAPN bit enables the negative edge, and the CAPP bit enables the positive edge. If both bits are set both edges will be enabled and a capture will occur for either transition. • The last bit in the register ECOM (CCAPMn.6) when set enables the comparator function. 39 4134D–8051–02/08 Table 24 shows the CCAPMn settings for the various PCA functions. Table 24. CCAPMn: PCA Modules Compare/Capture Control Registers CCAPMn Address n=0-4 CCAPM0 (0DAH) CCAPM1 (0DBH) CCAPM2 (0DCH) CCAPM3 (0DDH) CCAPM4 (0DEH) Reset value Symbol X ECOMn CAPPn 0 CAPNn 0 0 MATn TOGn 0 0 PWMm ECCFn 0 0 Function Not implemented, reserved for future use. (1) ECOMn Enable Comparator. ECOMn = 1 enables the comparator function. CAPPn Capture Positive, CAPPn = 1 enables positive edge capture. CAPNn Capture Negative, CAPNn = 1 enables negative edge capture. MATn Match. When MATn = 1, a match of the PCA counter with this module's compare/capture register causes the CCFn bit in CCON to be set, flagging an interrupt. TOGn Toggle. When TOGn = 1, a match of the PCA counter with this module's compare/capture register causes the CEXn pin to toggle. PWMn Pulse Width Modulation Mode. PWMn = 1 enables the CEXn pin to be used as a pulse width modulated output. ECCFn Enable CCF interrupt. Enables compare/capture flag CCFn in the CCON register to generate an interrupt. 1. User software should not write 1s to reserved bits. These bits may be used in future 8051 family products to invoke new features. In that case, the reset or inactive value of the new bit will be 0, and its active value will be 1. The value read from a reserved bit is indeterminate. Table 25. PCA Module Modes (CCAPMn Registers) ECOMn CAPPn CAPNn MATn TOGn PWMm ECCFn Module Function 0 0 0 0 0 0 0 No Operation X 1 0 0 0 0 X 16-bit capture by a positive-edge trigger on CEXn X 0 1 0 0 0 X 16-bit capture by a negative trigger on CEXn X 1 1 0 0 0 X 16-bit capture by a transition on CEXn 1 0 0 1 0 0 X 16-bit Software Timer/Compare mode. 1 0 0 1 1 0 X 16-bit High Speed Output 1 0 0 0 0 1 0 8-bit PWM 1 0 0 1 X 0 X Watchdog Timer (module 4 only) 40 4134D–8051–02/08 There are two additional registers associated with each of the PCA modules. They are CCAPnH and CCAPnL and these are the registers that store the 16-bit count when a capture occurs or a compare should occur. When a module is used in the PWM mode these registers are used to control the duty cycle of the output (See Table 26 & Table 27) Table 26. CCAPnH: PCA Modules Capture/Compare Registers High CCAPnH Address n=0-4 CCAP0H (0FAH) CCAP1H (0FBH) CCAP2H (0FCH) CCAP3H (0FDH) CCAP4H (0FEH) Reset value 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 Table 27. CCAPnL: PCA Modules Capture/Compare Registers Low CCAPnL Address n=0-4 CCAP0L (0EAH) CCAP1L (0EBH) CCAP2L (0ECH) CCAP3L (0EDH) CCAP4L (0EEH) Reset value 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 Table 28. CH: PCA Counter High CH Address 0F9H Reset value Table 29. CL: PCA Counter Low CL Address 0E9H Reset value 41 4134D–8051–02/08 PCA Capture Mode To use one of the PCA modules in the capture mode either one or both of the CCAPM bits CAPN and CAPP for that module must be set. The external CEX input for the module (on port 1) is sampled for a transition. When a valid transition occurs the PCA hardware loads the value of the PCA counter registers (CH and CL) into the module's capture registers (CCAPnL and CCAPnH). If the CCFn bit for the module in the CCON SFR and the ECCFn bit in the CCAPMn SFR are set then an interrupt will be generated (see Figure 23). Figure 23. PCA Capture Mode CF CR CCF4 CCF3 CCF2 CCF1 CCF0 CCON 0xD8 PCA IT PCA Counter/Timer Cex.n CH CL CCAPnH CCAPnL Capture ECOMn CAPPn CAPNn MATn TOGn PWMn ECCFn CCAPMn, n = 0 to 4 0xDA to 0xDE 42 4134D–8051–02/08 16-bit Software Timer/ Compare Mode The PCA modules can be used as software timers by setting both the ECOM and MAT bits in the modules CCAPMn register. The PCA timer will be compared to the module's capture registers and when a match occurs an interrupt will occur if the CCFn (CCON SFR) and the ECCFn (CCAPMn SFR) bits for the module are both set (see Figure 24). Figure 24. PCA Compare Mode and PCA Watchdog Timer CCON CF Write to CCAPnL CR CCF4 CCF3 CCF2 CCF1 CCF0 0xD8 Reset PCA IT Write to CCAPnH 1 CCAPnH 0 CCAPnL Enable Match 16 bit comparator CH RESET(1) CL PCA counter/timer ECOMn CAPPn CAPNn MATn TOGn PWMn ECCFn CIDL Note: WDTE CPS1 CPS0 ECF CCAPMn, n = 0 to 4 0xDA to 0xDE CMOD 0xD9 1. Only for Module 4 Before enabling ECOM bit, CCAPnL and CCAPnH should be set with a non zero value, other/wise an unwanted match could happen. Writing to CCAPnH will set the ECOM bit. Once ECOM set, writing CCAPnL will clear ECOM so that an unwanted match doesn’t occur while modifying the compare value. Writing to CCAPnH will set ECOM. For this reason, user software should write CCAPnL first, and then CCAPnH. Of course, the ECOM bit can still be controlled by accessing to CCAPMn register. 43 4134D–8051–02/08 High Speed Output Mode In this mode the CEX output (on port 1) associated with the PCA module will toggle each time a match occurs between the PCA counter and the module's capture registers. To activate this mode the TOG, MAT, and ECOM bits in the module's CCAPMn SFR must be set (see Figure 25). A prior write must be done to CCAPnL and CCAPnH before writing the ECOMn bit. Figure 25. PCA High Speed Output Mode CCON CF CR CCF4 CCF3 CCF2 CCF1 CCF0 0xD8 Write to CCAPnL Reset PCA IT Write to CCAPnH 1 CCAPnH 0 CCAPnL Enable 16-bit Comparator CH Match CL CEXn PCA Counter/Timer ECOMn CAPPn CAPNn MATn TOGn PWMn ECCFn CCAPMn, n = 0 to 4 0xDA to 0xDE Before enabling ECOM bit, CCAPnL and CCAPnH should be set with a non zero value, other/wise an unwanted match could happen. Once ECOM set, writing CCAPnL will clear ECOM so that an unwanted match doesn’t occur while modifying the compare value. Writing to CCAPnH will set ECOM. For this reason, user software should write CCAPnL first, and then CCAPnH. Of course, the ECOM bit can still be controlled by accessing to CCAPMn register. Pulse Width Modulator Mode All of the PCA modules can be used as PWM outputs. Figure 26 shows the PWM function. The frequency of the output depends on the source for the PCA timer. All of the modules will have the same frequency of output because they all share the PCA timer. The duty cycle of each module is independently variable using the module's capture register CCAPLn. When the value of the PCA CL SFR is less than the value in the module's CCAPLn SFR the output will be low, when it is equal to or greater than the output will be high. When CL overflows from FF to 00, CCAPLn is reloaded with the value in CCAPHn. This allows updating the PWM without glitches. The PWM and ECOM bits in the module's CCAPMn register must be set to enable the PWM mode. 44 4134D–8051–02/08 Figure 26. PCA PWM Mode CCAPnH Overflow CCAPnL “0” Enable 8-bit Comparator CEXn < ≥ “1” CL PCA Counter/Timer ECOMn CAPPn CAPNn MATn TOGn PWMn ECCFn CCAPMn, n = 0 to 4 0xDA to 0xDE PCA Watchdog Timer An on-board watchdog timer is available with the PCA to improve the reliability of the system without increasing chip count. Watchdog timers are useful for systems that are susceptible to noise, power glitches, or electrostatic discharge. Module 4 is the only PCA module that can be programmed as a watchdog. However, this module can still be used for other modes if the watchdog is not needed. Figure 24 shows a diagram of how the watchdog works. The user pre-loads a 16-bit value in the compare registers. Just like the other compare modes, this 16-bit value is compared to the PCA timer value. If a match is allowed to occur, an internal reset will be generated. This will not cause the RST pin to be driven high. In order to hold off the reset, the user has three options: 1. Periodically change the compare value so it will never match the PCA timer. 2. Periodically change the PCA timer value so it will never match the compare values. 3. Disable the watchdog by clearing the WDTE bit before a match occurs and then re-enable it. The first two options are more reliable because the watchdog timer is never disabled as in option #3. If the program counter ever goes astray, a match will eventually occur and cause an internal reset. The second option is also not recommended if other PCA modules are being used. Remember, the PCA timer is the time base for all modules; changing the time base for other modules would not be a good idea. Thus, in most applications the first solution is the best option. This watchdog timer won’t generate a reset out on the reset pin. 45 4134D–8051–02/08 Interrupt System The AT8xC5103 has a total of 5 interrupt vectors: one external interrupt INT0, two timer interrupts (timers 0, 1), PCA and SPI. These interrupts are shown in Figure 27.. Figure 27. Interrupt Control System High Priority Interrupt IPH, IP 3 INT0 IE0 0 3 TF0 0 Interrupt Polling Sequence 3 INT1 IE1 0 3 TF1 0 CF 3 PCA 0 CCFx NC NC 3 NC 3 NC 0 0 3 SPI 0 3 NC 0 Individual Enable Global Disable Low Priority Interrupt Each of the interrupt sources can be individually enabled or disabled by setting or clearing a bit in the Interrupt Enable register (see Table 31). This register also contains a global disable bit, which must be cleared to disable all interrupts at once. Each interrupt source can also be individually programmed to one of four priority levels by setting or clearing a bit in the Interrupt Priority register (see Table 33) and in the Interrupt Priority High register (see Table 35). Table 30 shows the bit values and priority levels associated with each combination. 46 4134D–8051–02/08 Table 30. Priority Level Bit Values IPH.x IPL.x Interrupt Level Priority 0 0 0 (Lowest) 0 1 1 1 0 2 1 1 3 (Highest) A low-priority interrupt can be interrupted by a high priority interrupt, but not by another low-priority interrupt. A high-priority interrupt can’t be interrupted by any other interrupt source. If two interrupt requests of different priority levels are received simultaneously, the request of higher priority level is serviced. If interrupt requests of the same priority level are received simultaneously, an internal polling sequence determines which request is serviced. Thus within each priority level there is a second priority structure determined by the polling sequence. Interrupt Name Interrupt Address Vector Priority Number External Interrupt (INT0) 0003h 1 Timer0 (TF0) 000Bh 2 External Interrupt (INT1) 0013h 3 Timer1 (TF1) 001Bh 4 PCA (CF or CCFn) 0033h 5 SPI 004Bh 6 . 47 4134D–8051–02/08 Table 31. IE0 Register IE0 (S:A8h) Interrupt Enable Register 7 6 5 4 3 2 1 0 EA EC - - ET1 EX1 ET0 EX0 Bit Number Bit Mnemonic Description 7 EA Enable All Interrupt Bit Clear to disable all interrupts. Set to enable all interrupts. If EA=1, each interrupt source is individually enabled or disabled by setting or clearing its interrupt enable bit. 6 EC PCA Interrupt Enable Clear to disable the PCA interrupt. Set to enable the PCA interrupt. 5 - Reserved The value read from this bit is indeterminate. Do not set this bit. 4 - Reserved The value read from this bit is indeterminate. Do not set this bit. 3 ET1 Timer 1 overflow interrupt Enable bit Clear to disable timer 1 overflow interrupt. Set to enable timer 1 overflow interrupt. 2 EX1 External Interrupt 1 Enable bit Clear to disable external interrupt 0. Set to enable external interrupt 0. 1 ET0 Timer 0 Overflow Interrupt Enable bit Clear to disable timer 0 overflow interrupt. Set to enable timer 0 overflow interrupt. 0 EX0 External Interrupt 0 Enable bit Clear to disable external interrupt 0. Set to enable external interrupt 0. Reset Value = 00XX 0000b Bit addressable 48 4134D–8051–02/08 Table 32. IE1 Register IE1 (S:B1h) Interrupt Enable Register 7 6 5 4 3 2 1 0 - - - - - ESPI - - Bit Number Bit Mnemonic 7 - Reserved The value read from this bit is indeterminate. Do not set this bit. 6 - Reserved The value read from this bit is indeterminate. Do not set this bit. 5 - Reserved The value read from this bit is indeterminate. Do not set this bit. 4 - Reserved The value read from this bit is indeterminate. Do not set this bit. 3 - Reserved The value read from this bit is indeterminate. Do not set this bit. 2 ESPI 1 - Reserved The value read from this bit is indeterminate. Do not set this bit. 0 - Reserved The value read from this bit is indeterminate. Do not set this bit. Description SPI Interrupt Enable bit Clear to disable the SPI interrupt. Set to enable the SPI interrupt. Reset Value = XXXX X0XXb No Bit addressable 49 4134D–8051–02/08 Table 33. IPL0 Register IPH0 - Interrupt Priority Low Register 0 7 6 5 4 3 2 1 0 - PPCL - - PT1L PX1L PT0L PX0L Bit Number Bit Mnemonic 7 - 6 PPCL 5 - Reserved The value read from this bit is indeterminate. Do not set this bit. 4 - Reserved The value read from this bit is indeterminate. Do not set this bit. 3 PT1L Timer 1 Overflow Interrupt Priority bit Refer to PT1H for priority level. 2 PX1L External Interrupt 1Priority bit Refer to PX1H for priority level. 1 PT0L Timer 0 Overflow Interrupt Priority bit Refer to PT0H for priority level. 0 PX0L External Interrupt 0 Priority bit Refer to PX0H for priority level. Description Reserved The value read from this bit is indeterminate. Do not set this bit. PCA Counter Interrupt Priority bit Refer to PPCH for priority level Reset Value = X0XX 0000b Bit addressable. 50 4134D–8051–02/08 Table 34. IPL1 Register IPL1 (S:B2h) IPL1 - Interrupt Priority Low Register 1 7 6 5 4 3 2 1 0 - - - - - PSPIL - - Bit Number Bit Mnemonic Description 7 6 - Reserved The value read from this bit is indeterminate. Do not set this bit. 5 - Reserved The value read from this bit is indeterminate. Do not set this bit. 4 - Reserved The value read from this bit is indeterminate. Do not set this bit. 3 - Reserved The value read from this bit is indeterminate. Do not set this bit. 2 PSPIL 1 - Reserved The value read from this bit is indeterminate. Do not set this bit. 0 - Reserved The value read from this bit is indeterminate. Do not set this bit. SPI Interrupt Priority Level Less Significant bit. Refer to PSPIH for priority level. Reset Value = XXXX X0XXb Not Bit addressable. 51 4134D–8051–02/08 Table 35. IPH0 Register IPH0 (S:B7h) IPH0 - Interrupt Priority High Register 0 7 6 5 4 3 2 1 0 - PPCH - - PT1H PX1H PT0H PX0H Bit Number Bit Mnemonic 7 - Description Reserved The value read from this bit is indeterminate. Do not set this bit. PCA Counter Interrupt Priority Level Most Significant bit PPCH PPCL Priority level 0 0 Lowest 0 1 1 0 1 1 Highest priority 6 PPCH 5 - Reserved The value read from this bit is indeterminate. Do not set this bit. 4 - Reserved The value read from this bit is indeterminate. Do not set this bit. 3 2 1 0 PT1H Timer 1 overflow interrupt Priority High bit PT1H PT1L Priority Level 0 0 Lowest 0 1 1 0 1 1 Highest PX1H External interrupt 1Priority High bit PX1H PX1L Priority Level 0 0 Lowest 0 1 1 0 1 1 Highest PT0H Timer 0 overflow interrupt Priority High bit PT0H PT0L Priority Level 0 0 Lowest 0 1 1 0 1 1 Highest PX0H External interrupt 0 Priority High bit PX0H PX0L Priority Level 0 0 Lowest 0 1 1 0 1 1 Highest Reset Value = X0XX 0000b Not bit addressable 52 4134D–8051–02/08 Table 36. IPH1 Register IPH1 - Interrupt Priority High Register 1 (B3h) 7 6 5 4 3 2 1 0 - - - - - PSPIH - - Bit Number Bit Mnemonic Description 7 6 - Reserved The value read from this bit is indeterminate. Do not set this bit. 5 - Reserved The value read from this bit is indeterminate. Do not set this bit. 4 - 3 - Reserved The value read from this bit is indeterminate. Do not set this bit. Reserved The value read from this bit is indeterminate. Do not set this bit. SPI Interrupt Priority Level Most Significant bit PSPIH PSPIL Priority level 0 0 Lowest 0 1 1 0 1 1 Highest 2 PSPIH 1 - Reserved The value read from this bit is indeterminate. Do not set this bit. 0 - Reserved The value read from this bit is indeterminate. Do not set this bit. Reset Value = XXXX X0XXb Not bit addressable 53 4134D–8051–02/08 Hardware Byte: Lock bit Table 37. Hardware Byte (HSB) 7 6 5 4 3 2 1 0 - LB - - - - - - Bit Number Bit Mnemonic 7 - 6 LB Description Reserved Do not write this bit User Program EPROM Lock Bit Programmed (0) to protect memory from external read Unprogrammed (1), read or write is allowed 5:0 - Reserved Do not write these bits The Lock system, when programmed, protects the on-chip program against software piracy. Only one level of protection for the on-chip code which when programmed are provided. If lock bit program, no read operation can be done, only CRC check. This security bit is accessible only with hardware programmer. 54 4134D–8051–02/08 Electrical Characteristics Absolute Maximum Ratings(1) *NOTICE: Ambiant Temperature Under Bias: A = automotive................................................. -40°C to 125°C Storage Temperature ................................... -55°C to + 150°C Voltage on VCC to VSS ..........................................-0.5V to + 6V Voltage on Any Pin to VSS ..........................-0.5V to VCC + 0.5V Power Consumption Measurement Stresses at or above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions may affect device reliability. Since the introduction of the first C51 device, every manufacturer made operating ICC measurements under reset, which made sense for the designs were the CPU was running under reset. In our new devices, the CPU is no more active during reset, so the power consumption is very low but is not really representative of what will happen in the customer system. That’s why, while keeping measurements under Reset, we present a new way to measure the operating ICC: Using an internal test ROM, the following code is executed: Label: SJMP Label (80 FE) Ports 1 and 4 are disconnected, RST = V CC, XTAL2 is not connected and XTAL1 is driven by the clock. This is much more representative of the real operating ICC. 55 4134D–8051–02/08 DC Parameters TA = -40°C to +125°C; VSS = 0V; VCC = 2.7 to 5.5V; F = 0 to 16 MHz Table 38. DC Parameters Symbol Parameter Min VIL Input Low Voltage VIH Input High Voltage except XTAL1, RST VIH1 Input High Voltage, XTAL1, RST Vhy Input hysteresis Voltage Typ Max Unit Test Conditions -0.5 0.2 VCC - 0.1 V 0.7 VCC VCC + 0.5 V 0.5 1.1 V VCC = 3.6V 0.8 1.8 V VCC = 5.5V 0.3 V IOL = 100 µA(4) 0.45 V IOL = 1.6 mA(4) 1.0 V IOL = 3.5 mA(4) 0.3 V IOL = 100 µA(4) 1.0 V IOL = 1.6 mA(4) VCC - 0.3 V IOH = -10 µA VCC - 0.7 V IOH = -30 µA VCC - 1.5 V IOH = -60 µA VCC - 0.3 V IOH = -10 µA VCC = 4.5V to 5.5V VOL Output Low Voltage, ports 1and 4 (6) VCC = 2.7V to 5.5V VCC = 4.5V to 5.5V VOH Output High Voltage, ports 1 and 4.(6) Pseudo Bi-directional Mode VCC = 2.7V to 5.5V VOH Output High Voltage, ports 1 and 4.(6) Push-pull Mode VCC - 1 V VCC - 0.5 IOH = -1 mA IOH = -100 µA Tr Ouput Rise time (Push-pull mode) 8 1000 ns Cload = 10 pF Tf Ouput Fall time (Push-pull mode) 6 500 ns Cload = 10 pF ILI Input Leakage Current ±10 µA 0.45V < Vin < VCC 30 RRST 90(5) Capacitance of I/O Buffer ICC AT87C5103 200 15 100 (OTP version) pF Fc = 1 MHz TA = 25°C µA VCC = 5.5 V µA VCC = 3.6V mA mA VCC < 4.5V Power Down Current 10 (3) operating (ROM version) kΩ 10 (3) IPD AT83C5103 150 RST Pulldown Resistor 50 CIO 60 (5) Power Supply Current Maximum values, X1 mode: (1) 50 0.8xF+0.8 1.2xF+1.5 VCC > 4.5V 56 4134D–8051–02/08 Table 38. DC Parameters (Continued) Symbol ICC Min Typ Power Supply Current Maximum values, X1 mode: idle VRET Notes: Parameter Max Unit 0.6xF+0.8 mA mA 1.0xF+1.5 Supply voltage during power-down mode 2 Test Conditions VCC < 4.5V(2) VCC > 4.5V(2) V 1. Operating ICC is measured with all output pins disconnected; XTAL1 driven with TCLCH, TCHCL = 5 ns (see Figure 32.), VIL = VSS + 0.5V, VIH = VCC - 0.5V; XTAL2 N.C.; RST= VCC;. The internal ROM runs the code 80 FE (label: SJMP label). ICC would be slightly higher if a crystal oscillator is used. 2. Idle ICC is measured with all output pins disconnected; XTAL1 driven with TCLCH, TCHCL = 5 ns, VIL = VSS + 0.5V, VIH = VCC 0.5V; XTAL2 N.C; RST = VSS (see Figure 30.). 3. Power Down ICC is measured with all output pins disconnected; XTAL2 NC.; RST = VSS (see Figure 31.). 4. Capacitance loading on Ports 0 and 2 may cause spurious noise pulses to be superimposed on the VOLs of ALE and Ports 1 and 3. The noise is due to external bus capacitance discharging into the Port 0 and Port 2 pins when these pins make 1 to 0 transitions during bus operation. In the worst cases (capacitive loading 100 pF), the noise pulse on the ALE line may exceed 0.45V with maxi VOL peak 0.6V. A Schmitt Trigger use is not necessary. 5. Typicals are based on a limited number of samples and are not guaranteed. The values listed are at room temperature and 5V. 6. If IOL exceeds the test condition, VOL may exceed the related specification. Pins are not guaranteed to sink current greater than the listed test conditions. Figure 28. ICC Test Condition, Under Reset VCC ICC VCC RST (NC) CLOCK SIGNAL XTAL2 XTAL1 VSS All other pins are disconnected. Figure 29. Operating ICC Test Condition VCC ICC Reset = VSS after a low pulse during at least 24 clock cycles VCC VCC RST (NC) CLOCK SIGNAL XTAL2 XTAL1 VSS All other pins are disconnected. 57 4134D–8051–02/08 Figure 30. ICC Test Condition, Idle Mode VCC ICC Reset = Vcc after a low pulse during at least 24 clock cycles VCC VCC RST (NC) XTAL2 XTAL1 VSS CLOCK SIGNAL All other pins are disconnected. Figure 31. ICC Test Condition, Power-Down Mode VCC ICC VCC Reset = Vcc after a low pulse during at least 24 clock cyclesVCC RST All other pins are disconnected. XTAL2 XTAL1 VSS Figure 32. Clock Signal Waveform for ICC Tests in Active and Idle Modes VCC-0.5V 0.7VCC 0.45V TCHCL TCLCH 0.2VCC-0.1 TCLCH = TCHCL = 5ns AC Parameters Explanation of the AC Symbols Each timing symbol has 5 characters. The first character is always a “T” (stands for Time). The other characters, depending on their positions, stand for the name of a signal or the logical status of that signal. The following is a list of all the characters and what they stand for. Example: TXHDV = Time from clock rising edge to input data valid. TA = -40°C to +125°C (Automotive temperature range); VSS = 0V; 3.135V < VCC < 3.465V The maximum applicable load capacitance for Port 1 and 3 is 80 pF. Timings will be guaranteed if these capacitances are respected. Higher capacitance values can be used, but timings will then be degraded. 58 4134D–8051–02/08 AC Testing Input/Output Waveforms Figure 33. AC Testing Input/Output Waveforms VCC-0.5V INPUT/OUTPUT 0.2VCC+0.9 0.2VCC-0.1 0.45 V AC inputs during testing are driven at VCC - 0.5 for a logic “1” and 0.45V for a logic “0”. Timing measurement are made at VIH min for a logic “1” and VIL max for a logic “0”. Float Waveforms Figure 34. Float Waveforms FLOAT VOH-0.1 V VLOAD VLOAD+0.1V VLOAD-0.1V VOL+0.1 V For timing purposes as port pin is no longer floating when a 100 mV change from load voltage occurs and begins to float when a 100 mV change from the loaded VOH/VOL level occurs. IOL/IOH ≥ ± 20 mA. Clock Waveforms Valid in normal clock mode. In X2 Mode XTAL2 signal must be changed to XTAL2 divided by 2. Figure 35. Clock Waveforms INTERNAL CLOCK STATE4 P1P2 STATE5 P1P2 STATE1 STATE6 P1P2 P1P2 OLD DATA NEW DATA STATE2 P1P2 STATE3 P1P2 STATE4 P1P2 STATE5 P1P2 XTAL2 PORT OPERATION MOV DEST PORT (P1, P3, P4) (INCLUDES INT0, INT1, TO, T1) P1, P3, P4 PINS SERIAL PORT SHIFT CLOCK TXD (MODE 0) RXD SAMPLED P1, P3, P4 PINS SAMPLED RXD SAMPLED This diagram indicates when signals are clocked internally. The time it takes the signals to propagate to the pins, however, ranges from 25 to 125 ns. This propagation delay is dependent on variables such as temperature and pin loading. Propagation also varies from output to output and component. Typically though (TA=25°C fully loaded) RD and WR propagation delays are approximately 50 ns. The other signals are typically 85 ns. Propagation delays are incorporated in the AC specifications. 59 4134D–8051–02/08 Ordering Information Part Number Code Memory Size (Bytes) Supply Voltage Temperature Range Max Frequency Packing Package AT87C5103-IBSIL AT87C5103-IBRIL AT87C5103-ICSIL AT87C5103-ICRIL OBSOLETE AT83C5103xxx-IBSIL AT83C5103xxx-IBRIL AT83C5103xxx-ICSIL AT83C5103xxx-ICRIL AT87C5103-IBSAL 12K OTP 3.0 - 5.5V Automotive 16 MHz Stick SSOP16 AT87C5103-IBRAL 12K OTP 3.0 - 5.5V Automotive 16 MHz Reel SSOP16 AT87C5103-ICSAL 12K OTP 3.0 - 5.5V Automotive 16 MHz Stick SSOP24 AT87C5103-ICRAL 12K OTP 3.0 - 5.5V Automotive 16 MHz Reel SSOP24 AT83C5103xxx-IBSAL 12K ROM 3.0 - 5.5V Automotive 16 MHz Stick SSOP16 AT83C5103xxx-IBRAL 12K ROM 3.0 - 5.5V Automotive 16 MHz Reel SSOP16 AT83C5103xxx-ICSAL 12K ROM 3.0 - 5.5V Automotive 16 MHz Stick SSOP24 AT83C5103xxx-ICRAL 12K ROM 3.0 - 5.5V Automotive 16 MHz Reel SSOP24 60 4134D–8051–02/08 Package Drawings SSOP 16 Leads 61 4134D–8051–02/08 SSOP 24 Leads 62 4134D–8051–02/08 Datasheet Change Log for AT8C5103 Changes from 4134A05/02 to 4134B-04/03 1. Changed the Reset Pulldown resistor for ROM version (See AC/DC parameters). Changes from 4134B04/03 to 4134C-09/04 1. Changed the “Hardware Byte: Lock bit” page. Changes from 4134C09/04 to 4134D-02/08 1. Removed non-green part numbers from ordering information. 63 4134D–8051–02/08 Atmel Headquarters Atmel Operations Corporate Headquarters Memory 2325 Orchard Parkway San Jose, CA 95131 TEL 1(408) 441-0311 FAX 1(408) 487-2600 Europe Atmel Sarl Route des Arsenaux 41 Case Postale 80 CH-1705 Fribourg Switzerland TEL (41) 26-426-5555 FAX (41) 26-426-5500 Asia Room 1219 Chinachem Golden Plaza 77 Mody Road Tsimhatsui East Kowloon Hong Kong TEL (852) 2721-9778 FAX (852) 2722-1369 Japan 9F, Tonetsu Shinkawa Bldg. 1-24-8 Shinkawa Chuo-ku, Tokyo 104-0033 Japan TEL (81) 3-3523-3551 FAX (81) 3-3523-7581 2325 Orchard Parkway San Jose, CA 95131 TEL 1(408) 441-0311 FAX 1(408) 436-4314 RF/Automotive Theresienstrasse 2 Postfach 3535 74025 Heilbronn, Germany TEL (49) 71-31-67-0 FAX (49) 71-31-67-2340 Microcontrollers 2325 Orchard Parkway San Jose, CA 95131 TEL 1(408) 441-0311 FAX 1(408) 436-4314 La Chantrerie BP 70602 44306 Nantes Cedex 3, France TEL (33) 2-40-18-18-18 FAX (33) 2-40-18-19-60 ASIC/ASSP/Smart Cards Zone Industrielle 13106 Rousset Cedex, France TEL (33) 4-42-53-60-00 FAX (33) 4-42-53-60-01 1150 East Cheyenne Mtn. Blvd. Colorado Springs, CO 80906 TEL 1(719) 576-3300 FAX 1(719) 540-1759 Biometrics/Imaging/Hi-Rel MPU/ High Speed Converters/RF Datacom Avenue de Rochepleine BP 123 38521 Saint-Egreve Cedex, France TEL (33) 4-76-58-30-00 FAX (33) 4-76-58-34-80 1150 East Cheyenne Mtn. Blvd. Colorado Springs, CO 80906 TEL 1(719) 576-3300 FAX 1(719) 540-1759 Scottish Enterprise Technology Park Maxwell Building East Kilbride G75 0QR, Scotland TEL (44) 1355-803-000 FAX (44) 1355-242-743 e-mail [email protected] Web Site http://www.atmel.com Disclaimer: Atmel Corporation makes no warranty for the use of its products, other than those expressly contained in the Company’s standard warranty which is detailed in Atmel’s Terms and Conditions located on the Company’s web site. The Company assumes no responsibility for any errors which may appear in this document, reserves the right to change devices or specifications detailed herein at any time without notice, and does not make any commitment to update the information contained herein. No licenses to patents or other intellectual property of Atmel are granted by the Company in connection with the sale of Atmel products, expressly or by implication. Atmel’s products are not authorized for use as critical components in life support devices or systems. © Atmel Corporation 2008. All rights reserved. Atmel, the Atmel logo, andcombinations thereof are registered trademarks of Atmel Corporation or its subsidiaries. Other terms and product names in this document may be the trademarks of others. Printed on recycled paper. 4134D–8051–02/08 0M