8WD53 Manual

Signalling lights
8WD53.
EN 60598/VDE 0711 Part 1
IEC 60947-5-1
English
Operating Instructions
Order No.: 8ZX1012-0WD50-1AA1
Applications
3.
Install signalling light with seal from outside of housing.
Field of use
4.
Screw on hexagon nut and tighten.
• When assembled state and the cover fitted, signalling lights 8WD53. complied with a degree of protection of IP 65.
• In order to maintain shock-hazard protection (VDE 0106) on the part of the
terminals, proper connection of the live conductors to these terminals is
essential.
• The signalling lights are constructed and tested in accordance with
EN 60598/VDE 0711 Part 1. To ensure safe operation, the following notes
should be observed:
Installing bulb for signalling light 8WD5 300-1A.
1.
Turn lampholder anticlockwise and remove.
2.
Install bulb in bayonet catch.
3.
Insert lampholder in dome and turn clockwise until fully home.
It is important to note the rated voltages of the signalling
devices. Excessively high voltage will result in damage.
WARNING:
HAZARDOUS VOLTAGE
CAN CAUSE ELECTRICAL SHOCK
AND BURNS.
DISCONNECT POWER BEFORE PROCEEDING
WITH ANY WORK ON THIS EQUIPMENT.
If injury to persons or damage to equipment can occur due to
the failure or malfunctioning of the signalling device, provide
additional safety precautions (limit switches, protective
device, etc.) to prevent this.
General principle of operation
The signalling column converts electrical signals into visible signals:
• steady light, LED steady glow
,
• blinking light
, LED blinking light
• LED rotating flashing light
• stroboscopic light
Connection
1.
Remove cross-head screws and the wire web for strain-relief
device (Fig. IIb).
2.
Feed in cable radially or axially and connect to terminals.
3.
Install wire clevis for strain-relief device and tighten both crosshead screws.
Commissioning
Signalling light 8WD5 300-1A.
Allowance must be made for the fact that power conusmption at power-on is
10 times higher than normal! When driving a control output with short-circuit
breaker or current limiter, the rush-in current peak can result in a fault message.
Maintenance
General care
Design
Fig. IIa
1
2
3
4
5
6
8a
8b
9
10
M3 screw connction
Strain-relief device
Flasher light 8WD5 350-0C.
Fig. I
Fig. II
Fig. III
Fig. IV
Signalling light
Design
Dimensional drawing
Mounting hole
Ordering data
7
Fig. IIb
Figures
Clean the signalling column with a mild detergent which contains no abrasive.
Do NOT use thinner. Keep away from soluble machining oil!
Dome
Thread PG 29
Rubber seal
Housing wall
Hexagon nut
Bulb BA 15 d, max. 10 W
(not included in scope of supply)
Lampholder with bayonet catch
(removable in case of signalling light
8WD5 300-1A)
Outgoing cable, radial
Outgoing cable, axial
Technical Data
Housing
Impact resistance
Fastening
Temperature
Connection
Red, green, yellow, blue, clear polycarbonate
Black, impact-resistant polycarbonate
20 J in accordance with EN 50014
Drilled hole, dia. 37 mm (PG 29)
-20°C to +60°C )
M3 screw connection, ≤ 2.5 mm², ≤ 0.5 Nm
AWG 18 to 14
LED signalling light 8WD5 320-5..
Flashing frequency
Rotating frequency
Current
Flashing power
Current
approx. 1 Hz
approx. 20 rpm
approx. 70 mA (rotating light)
approx. 60 mA (steady light)
approx. 40 mA (blinking light)
2 Ws/approx. 1 Hz
approx. 125 mA (24 V ≅)
approx. 70 mA (115 V ∼)
approx. 15 mA (230 V ∼)
Bulbs: BA 15 d, 7 W, height 35 mm
Installation
When mounting, ensure that there is a flat, level surface (sealing) and adequate space for the complete signalling light (see Fig. III for dimensions).
Installing signalling light 8WD5 300-1A.
1.
Drill mounting hole in housing wall
(Fig. IV).
2.
2
Remove hexagon nut.
24 V
115 V
230 V
8WD4 328-1XX
8WD4 348-1XX
8WD4 358-1XX
III
∅
∅ 68
7
16
32
64,5
I
PG 29 (∅
37)
∅ ∅ 75
∅
IIa
IV
39
1
2
3
4
5
6
7
8a
8b
IIb
9
Technische Änderungen vorbehalten.
Subject to change without prior notice
© Siemens AG 1998
10
Bestell-Nr./Order No.: 8ZX1012-0W50-1AA1