Signalling lights 8WD53. EN 60598/VDE 0711 Part 1 IEC 60947-5-1 English Operating Instructions Order No.: 8ZX1012-0WD50-1AA1 Applications 3. Install signalling light with seal from outside of housing. Field of use 4. Screw on hexagon nut and tighten. • When assembled state and the cover fitted, signalling lights 8WD53. complied with a degree of protection of IP 65. • In order to maintain shock-hazard protection (VDE 0106) on the part of the terminals, proper connection of the live conductors to these terminals is essential. • The signalling lights are constructed and tested in accordance with EN 60598/VDE 0711 Part 1. To ensure safe operation, the following notes should be observed: Installing bulb for signalling light 8WD5 300-1A. 1. Turn lampholder anticlockwise and remove. 2. Install bulb in bayonet catch. 3. Insert lampholder in dome and turn clockwise until fully home. It is important to note the rated voltages of the signalling devices. Excessively high voltage will result in damage. WARNING: HAZARDOUS VOLTAGE CAN CAUSE ELECTRICAL SHOCK AND BURNS. DISCONNECT POWER BEFORE PROCEEDING WITH ANY WORK ON THIS EQUIPMENT. If injury to persons or damage to equipment can occur due to the failure or malfunctioning of the signalling device, provide additional safety precautions (limit switches, protective device, etc.) to prevent this. General principle of operation The signalling column converts electrical signals into visible signals: • steady light, LED steady glow , • blinking light , LED blinking light • LED rotating flashing light • stroboscopic light Connection 1. Remove cross-head screws and the wire web for strain-relief device (Fig. IIb). 2. Feed in cable radially or axially and connect to terminals. 3. Install wire clevis for strain-relief device and tighten both crosshead screws. Commissioning Signalling light 8WD5 300-1A. Allowance must be made for the fact that power conusmption at power-on is 10 times higher than normal! When driving a control output with short-circuit breaker or current limiter, the rush-in current peak can result in a fault message. Maintenance General care Design Fig. IIa 1 2 3 4 5 6 8a 8b 9 10 M3 screw connction Strain-relief device Flasher light 8WD5 350-0C. Fig. I Fig. II Fig. III Fig. IV Signalling light Design Dimensional drawing Mounting hole Ordering data 7 Fig. IIb Figures Clean the signalling column with a mild detergent which contains no abrasive. Do NOT use thinner. Keep away from soluble machining oil! Dome Thread PG 29 Rubber seal Housing wall Hexagon nut Bulb BA 15 d, max. 10 W (not included in scope of supply) Lampholder with bayonet catch (removable in case of signalling light 8WD5 300-1A) Outgoing cable, radial Outgoing cable, axial Technical Data Housing Impact resistance Fastening Temperature Connection Red, green, yellow, blue, clear polycarbonate Black, impact-resistant polycarbonate 20 J in accordance with EN 50014 Drilled hole, dia. 37 mm (PG 29) -20°C to +60°C ) M3 screw connection, ≤ 2.5 mm², ≤ 0.5 Nm AWG 18 to 14 LED signalling light 8WD5 320-5.. Flashing frequency Rotating frequency Current Flashing power Current approx. 1 Hz approx. 20 rpm approx. 70 mA (rotating light) approx. 60 mA (steady light) approx. 40 mA (blinking light) 2 Ws/approx. 1 Hz approx. 125 mA (24 V ≅) approx. 70 mA (115 V ∼) approx. 15 mA (230 V ∼) Bulbs: BA 15 d, 7 W, height 35 mm Installation When mounting, ensure that there is a flat, level surface (sealing) and adequate space for the complete signalling light (see Fig. III for dimensions). Installing signalling light 8WD5 300-1A. 1. Drill mounting hole in housing wall (Fig. IV). 2. 2 Remove hexagon nut. 24 V 115 V 230 V 8WD4 328-1XX 8WD4 348-1XX 8WD4 358-1XX III ∅ ∅ 68 7 16 32 64,5 I PG 29 (∅ 37) ∅ ∅ 75 ∅ IIa IV 39 1 2 3 4 5 6 7 8a 8b IIb 9 Technische Änderungen vorbehalten. Subject to change without prior notice © Siemens AG 1998 10 Bestell-Nr./Order No.: 8ZX1012-0W50-1AA1 Printed in the Federal Republic of Germany