Download

2D Code Reader
V400-F
Created to meet real-world
production site needs.
For Easier, More Accurate Quality Contr
We ' r e t h i n k i ng a b o u t u si ng a 2 D Code Reader, but...
With direct marking, reading
stability can be lowered by the
condition of the material or workpiece.
We need
stable data
reading.
We want to
reduce our
startup time.
We want to
improve process
changeovers on
multi-product
lines.
It takes time to make adjustments whenever
there's an increase in the number of different
workpieces.
2
The camera, lens, and lighting changes
that are needed for each workpiece
lower efficiency.
ol
OMRON c r ea t ed
the 2 D Code Reader
to m ee t ne eds l i ke t hese .
Actual
Size
In the V400-F, we have listened carefully to user demands
and wor ked hard to achieve high levels of simplicity and
reliability in a code reader that vir tually anybody can install,
operate, and adjust.
We also pursued highly accurate reading of directly mar ked
2D codes, in addition to pr inted codes.
The V400-F is a new 2D Code Reader that makes production
sites considerably "smar ter" in a wide range of environments.
3
Simplicity and High Performance in Response to User Needs
Si m p l i f i e d Setu p ...
For Faster Star tups
Si mp ler S e le c tio n w ith a One- piece Design
The selection process is greatly simplified by the integrated lens and lighting design.
No more worrying about having to match each workpiece to a vast number of lens and lighting combinations.
Camera
W 50 mm
Conventional
Determine the system configuration.
Install and adjust.
Test.
Select the system configuration.
(Controller, lens, lighting, cables, and monitor)
Select the reading conditions.
(Field of vision and working distance)
H 40 mm
Lens
This part has all been eliminated!
V400-F
LED lighting
D 97.1 mm
Select the system configuration.
(Integrated lens and lighting)
Select the reading conditions.
(One-step teaching)
Test
Ea s i er In itia l A d ju stment s
Teaching functions that anybody can use .
Easy, one-step teaching lets you set the reading parameters instantly.
Naturally, adjustments are also possible using commands from external
devices.
*Support Software is also available for setting the parameters from a personal computer.
(Ask your OMRON representative or dealer for details.)
Ban k s . . .
D ramat i c a lly R e duce Pro cess
C h a n g e ov e r S t e ps
Bank
Bank 1
C h a ng e th e P ro ce s s wit hout
St o p p in g th e L in e
Bank 2
Bank 3
Bank 4
Change the bank.
Bank 5
Bank 6
The Auto Bank Change function lets the operator
Bank 7
automatically change preset reading conditions recorded
Bank 9
Bank 8
Bank 10
in banks. Up to five banks can be set in advance to greatly
reduce bothersome steps when changing the line process.
The code changes!
4
H i g h Pe rfo rma n ce ...
For Stable Reading
St a ble , A c c u rate R ea d ing for Any Workpiece
We have achieved high accuracy for directly marked codes by combining the industry's most advanced reading
algorithm with lighting control that is optimized for data reading. Even directly marked 2D codes printed onto materials
with varying reflectivity, such as metals, printed wiring boards, and glass, can be read with excellent accuracy.
PART#
Metal (treated surface)
Glass
Printed wiring boards
Label
T h re e Ty p es to C h o o s e f rom for Each Applicat ion
There are three 2D Code Readers to choose from to match
your application. This enables flexible response to different
workpieces and production site conditions. Use the C-mount
Appearance
model when specific settings are necessary for the lighting or
lens.
Type
Se n s itive R es p o n se to Workpiece
C h a ng es
Narrow field of vision Wide field of vision
Model V400-F250
V400-F350
Field of
vision
Working
distance
Cell
size *1
Code
size *1
14 × 18 mm
31 × 42 mm
100 mm
200 mm
0.2 to 0.3 mm
0.4 to 0.7 mm
2 to 9 mm
4 to 21 mm
C-mount
V400-F050
Can be varied using
a C-mount lens.
External 2-channel
lighting. *2
*1 These are intended to be reference values for use in model selection.
*2 For use only with Moritex MG-Wave Series lighting.
The Retry and Preprocess Filtering functions allow stable reading even under harsh conditions. They eliminate the
effects of printing conditions and workpiece changes, such as oil, ambient light, and varying substrate types.
Retr y Function
Preprocess Filtering Function
Multiple readings can be taken while changing the
exposure time and adjusting the brightness of the light.
Three of the following four types of filtering can be used
for images that have been taken: Smoothing, Dilation,
Erosion, and Median.
Before retry
Before Dilation
After retry
After Dilation
5
Applications
Metal parts
Printed wiring boards
LCD glass substrates
Trading partner labels
System Configuration
Monitor Cable
V400-WM0*
5m
Monitor
V400-W23/23P*
5m
V400-F250/350
SYSMAC Series PLC
Lighting
Power Supply
V400-W24/24P*
Moritex MG-Wave Series
recommended.
5m
External Lighting Connector
Personal computer
(Connected to the RC-232C port)
V400-F050
Lens
C mount
Power Supply
The CS1W-CIF31 USB-Serial
Conversion Cable (mfd. by OMRON)
is recommended for connection to a
USB terminal.
Recommended power supply: OMRON S8VS-03024
*Use only the specified cable.
Ordering Information
2D Code Readers
Name
Special Lighting Lens
C-Mount
Model
Field of vision
V400-F250
14 ´ 18 mm
V400-F350
31 ´ 42 mm
V400-F050
Changes according to the lens.
Accessories (Order Separately) and Cables
Name
Model
Cable length
Communications Cable
V400-W23P 5M (PNP)
5m
V400-W24 5M (NPN)
V400-W24P 5M (PNP)
Monitor Cable
6
V400-WM0 5M
Remarks
For connection to SYSMAC Series
PLC (includes power line)
V400-W23 5M (NPN)
5m
For connection to an IBM PC/AT or
compatible (includes power line)
Specifications
Model
V400-F050
Dimensions
Working distance (WD)
40 ´ 50 ´ 75.3 mm
40 ´ 50 ´ 97.1 mm
Approx. 100 mm
Approx. 200 mm
Depends on the lens.
Field of vision
Lighting
V400-F350
V400-F250
Depends on the lens.
Approx. 14 ´ 18 mm
Up to two can be directly powered.
Red LED
Approx. 31 ´ 42 mm
Data Matrix, ECC200, 10 ´ 10 to 64 ´ 64, 8 ´ 18 to 16 ´ 48,
Applicable codes
QR Code (Models 1, 2), 21 ´ 21 to 57 ´ 57 (Versions 1 to 10)
Image sensor
Effective pixels
Power supply voltage
Power consumption
Insulation resistance
Withstand voltage
Leakage current
Power line: 2 kVp-p, Pulse width: 50 ns, Rise time: 5 ns,
Consecutive burst time: 15 ms, Cycle: 300 ms
Noise resistance
Applicable standards
CE: EN 61326:1997, +A1:1998, +A2:2001 (EMI: Class A)
10 to 150 Hz, 0.35-mm half-amplitude (maximum acceleration: 50 m/s2)
10 times for 8 minutes each in 3 directions
Vibration resistance
Shock resistance
Ambient humidity
Ambient temperature
Ambient environment
Degree of protection
None
Approx. 130 g
Weight
IEC 60529 IP67
Approx. 150 g
Dimensions
(Unit: mm)
2D Code Readers
Communications Cable and Monitor Cable
V400-F050
V400-W23/23P/24/24P
39.8
5000
500
20
50
Power supply,
communications
connector
(84.1)
75.3
1.6
11.5 dia.
40
11.5 dia.
(13.1)
Lighting
connector
(L-CH)
Monitor cable
connector
26.8
25.4
Four M3,
depth: 5
50
D-sub 9-pin
connector
Vinyl-insulated round cable,
7.0-dia. with 12 conductors
Nameplate
(16.8)
25.4
1"-32UN-2A
(C mount)
50
12-pin round connector
15.5 dia.
Lighting
connector
(R-CH)
V400-WM0
12-pin round connector
39.8
5000
60
70
(105.9)
97.1
50
Monitor cable
connector
15.5 dia.
40
Power supply,
communications
connector
10
Vinyl-insulated round cable,
6.5-dia. with 3 conductors
11.5 dia.
150
Nameplate
(13.1)
40
11.5 dia.
RCA jack
12.2 dia.
V400-F250/350
25.4
Four M3,
depth: 5
(16.8)
25.4
48.6
Mounting Base
31.6
Four 3.4-dia holes
o
Tw
35.2
2,
M
de
Four 5.4-dia. countersunk holes, depth: 2.2
8
h:
pt
1/4-20UNC
44
25.4
20
25.4
44
15
5
4
M
o s
Tw ole
h
7
A Handy, LCD-equipped 2D Code Reader
Capable of Reading Directly Marked Codes
V400-H111/211
Excellent
reading
performance
Read while
viewing
the LCD
The V400-H achieves a high level of accuracy by
combining the industry's most advanced reading
algorithm with an optical system that is optimized
for reading directly marked codes.
Use the LCD monitor to check the codes as you read
them. The information that is read is displayed on the
screen, facilitating confirming operation.
Refer to the catalog for details (Cat. No. Q146).
Model with Narrow Field of Vision (V400-H111):
5- to 10-mm field of vision
Model with Wide Field of Vision (V400-H211):
15- to 30-mm field of vision
Applications: Reading codes on metal parts,
LCD wafers, printed wiring board substrates
This document provides information mainly for selecting suitable models. Please read the Z242 carefully for information that the user must
understand and accept before purchase, including information on warranty, limitations of liability, and precautions.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Industrial Automation Company
Sensing Devices Division H.Q.
Application Sensors Division
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81) 75-344-7068/Fax: (81) 75-344-7107
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen,
Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
Authorized Distributor:
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark, Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON Industrial Automation Global: www.ia.omron.com
In the interest of product improvement,
specifications are subject to change without notice.
CSM_1_4_0216
Cat. No. Q148-E1
Printed in Japan