FAM Data sheet Sensing element/Absolute ■Features Barometric pressure measurable Surface mount package ■Ordering Information FAM-15P A SR Terminal leads configuration Model Surface mount package Rated Pressure (PSI) Pressure type A:Absolute pressure Weight (grams) RoHS compliance 0.3 Measurable pressure range(kPa.abs) Part number 34.66 to 168.0 FAM-15PASR ■Specifications Model FAM-15PASR Recommended operating conditions Pressure type Absolute pressure Rated pressure 168.0 Measurable pressure range 34.66 to 168.0 Temperature range 0 to 50 Pressure media Non-corrosive gases only (No liquid) Excitation current (Constant) 1.5 Absolute maximum rating Maximum load pressure Twice of rated pressure Maximum excitation current 3.0 Operating temperature -20 to 100 Storage temperature -40 to 120 Operating humidity 30 to 80 (Non dew condition) Electric characteristics (Drive Current 1.5mA constant ,ambient temperature Ta=25deg.C) Output span voltage 80 to 160 (at 34.66 to 168.0kPa.abs) Offset voltage 50 to 130 (at 101.3kPa.abs) Bridge resistance 4000 to 6000 Response time 2 (for the reference) Accuracy TSO* +/-3 TCS* 2.5 Linearity +/-0.3 Pressure hysteresis +/-0.2 *TSO : Temperature sensitivity of offset voltage(Temperature range from 0-50 deg.C) *TCS : Temperature coefficient of output span voltage(Temperature range from 0-50 deg.C) 1 Unit kPa.abs kPa.abs deg.C mADC mADC deg.C deg.C %RH mV mV Ω msec. %FS/0-50deg.C %FS/0-50deg.C %FS %FS FAM Data sheet Sensing element/Absolute P1= 34.66 kPa.abs P2= 67.98 kPa.abs P3= 101.3 kPa.abs P4= 168.0 kPa.abs Offset voltage (mV) Voff = V(P3,T) T1= 0 deg.C T2= 25 deg.C T3= 50 deg.C at 101.3kPa.abs Output voltage at full scale (mV) V(P1,T) at 34.66kPa.abs V(P4,T) at 168.0kPa.abs Output span voltage (mV) SV = V(P4,T) - V(P1,T) SV(0) = V(P4,T1) - V(P1,T1) SV(25) = V(P4,T2) - V(P1,T2) SV(50) = V(P4,T3) - V(P1,T3) Temperature sensitivity of offset voltage (%FS) TSO = {LARGER ONE} / SV(25) x 100 LARGER ONE = larger absolute value which of {V(P3,T1)-V(P3,T2)} and {V(P3,T3)-V(P3,T2)} Temperature coefficient of output span voltage (%FS) TCS = {max[SV(0),SV(25),SV(50)] - min[SV(0),SV(25),SV(50)] } / SV(25) x 100 Linearity (%FS) NL = {V(P2,T2) - [V(P1,T2)+V(P3,T2)]/2 } / SV(25) x 100 Pressure hysteresis (%FS) Phys = {V’(P3,T2) - V(P3,T2) } / SV(25) x 100 V’(P3,T2) : Output voltage against P1 after stressing by P3 pressure. 2 FAM Data sheet Sensing element/Absolute ■Outline dimensions■ ■Connection diagram■ 3 FAM Data sheet Sensing element/Absolute ■Output characteristics■ ↑Output voltage(mV) Offset voltage Output span voltage 34.66 101.3 168.0 Atomospheric pressure Note ; →Pressure(kPa.abs) Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. Please keep the sensors sealed using static shielding bags on storage.The pins of the sensor are plated by Ag. If the sensors expose to an atmosphere, the pins will be black by sulfuration. Please set Zero-calibration function up your products. The offset voltage may be shifted some mechanical stress such as mounting, installation and etc. over longtime using. 4 FAM Data sheet Sensing element/Absolute Reflow Soldering process recommendation profile Package Surface Temperature (Degree C) 230 210 150 Room Temp. Time a a: Rump up rate b: Pre-heating c: Rump up rate d: Heating e: Rump down rate Note ; b c d e 1 or 2 deg.C/sec. 150 to 180 deg.C,within 60 to120sec. 1 to 2 deg.C/sec. max.230 deg.C,max.10sec. 210 deg.C,within 30sec. 1 or 2 deg.C/sec. 1 ) Temperature means Surface temperature of the sensor package. 2 ) Reflow process max. 2 times. 3 ) Do not wash the sensor. 4 ) Do not put the solder and flux on the sensor package. If you have any questions regarding technical issues or specifications, please contact us. Fujikura Ltd. Sensor Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected] 5