FUJIKURA FDM

FDM Data sheet
Sensing element/Differential
■Features
Differential pressure,Surface mount package
■Ordering Information
FDM-07P
D SR
Terminal leads configuration
Model
Surface mount package
Pressure type
D:Differential pressure
Rated Pressure
(PSI)
Weight
(grams)
RoHS compliance
1.2
Measurable pressure
range(kPa)
-13.79 to 13.79
-34.47 to 34.47
-48.26 to 48.26
-103.4 to 103.4
-206.8 to 206.8
-344.7 to 344.7
-482.6 to 482.6
-827.4 to 827.4
Part number
FDM-02PDSR
FDM-05PDSR
FDM-07PDSR
FDM-15PDSR
FDM-30PDSR
FDM-50PDSR
FDM-70PDSR
FDM-120PDSR
■Specifications
Model
02PD
Recommended operating conditions
Pressure type
Rated pressure
Measurable pressure range
Temperature range
Pressure media
Excitation current (Constant)
13.79
-13.79
to 13.79
05PD
07PD
34.47
-34.47
to 34.47
48.26
-48.26
to 48.26
15PD
30PD
50PD
Differential pressure
103.4
206.8
344.7
-103.4
-206.8
-344.7
to 103.4 to 206.8 to 344.7
0 to 50
Non-corrosive gases only (No liquid)
1.5
70PD
120PD
482.6
-482.6
to 482.6
827.4
-827.4
to 827.4
Unit
kPa
kPa
deg.C
mADC
Absolute maximum rating
Maximum differential pressure **1
Port1 Maximum load pressure
Port2 Maximum load pressure
Maximum excitation current
Operating temperature
Storage temperature
Operating humidity
Twice of rated pressure
3.0
-20 to 100
-40 to 120
30 to 80 (Non dew condition)
Electric characteristics (Drive Current 1.5mA constant ,ambient temperature Ta=25deg.C)
Output span voltage **2
60 to 140 (at 0kPa to rated pressure)
Offset voltage **2
+/-20 (at 0kPa)
Bridge resistance
4000 to 6000
Response time
2 (for the reference)
Accuracy
TSO*
+/-5
TCS*
2.5
Linearity
+/-0.5
+/-0.3
Pressure hysteresis
+/-0.4
+/-0.2
*TSO : Temperature sensitivity of offset voltage(Temperature range from 0-50 deg.C)
*TCS : Temperature coefficient of output span voltage(Temperature range from 0-50 deg.C)
**1 Port1 pressure > Port2 pressure , Port2 pressure : reference pressure
**2 Output refers to pressure at pressure port2.
1
1.5 times
of rating
pressure
mADC
deg.C
deg.C
%RH
mV
mV
Ω
msec.
%FS/050deg.C
+/-0.5
+/-0.6
+/-0.4
%FS
%FS
FDM Data sheet
Sensing element/Differential
Pressure(kPa) =Port1 pressure - Port2 pressure
P1= 0 kPa
P2= 1/2 x P3 (kPa)
P3= reted pressure (kPa)
T1= 0 deg.C
T2= 25 deg.C
T3= 50 deg.C
Offset voltage (mV)
Voff = V(P1,T)
Voff(0) = V(P1,T1)
Voff(25) = V(P1,T2)
Voff(50) = V(P1,T3)
Output voltage at full scale (mV)
Vfs = V(P3,T)
Vfs(0) = V(P3,T1)
Vfs(25) = V(P3,T2)
Vfs(50) = V(P3,T3)
Output span voltage (mV)
SV = Vfs - Voff
SV(0) = Vfs(0) - Voff(0)
SV(25) = Vfs(25) - Voff(25)
SV(50) = Vfs(50) - Voff(50)
Temperature sensitivity of offset voltage (%FS)
TSO = {LARGER ONE} / SV(25) x 100
LARGER ONE = larger absolute value which of {Voff(0) - Voff(25)} and {Voff(50) - Voff(25)}
Temperature coefficient of output span voltage (%FS)
TCS = {max[SV(0),SV(25),SV(50)] - min[SV(0),SV(25),SV(50)] } / SV(25) x 100
Linearity (%FS)
NL = {V(P2,T2) - [Voff(25)+Vfs(25)]/2 } / SV(25) x 100
Pressure hysteresis (%FS)
Phys = {Voff’(25) - Voff(25) } / SV(25) x 100
Voff’(25) : Output voltage against P1 after stressing by P3 pressure.
2
FDM Data sheet
Sensing element/Differential
■Outline dimensions■
■Connection diagram■
3
FDM Data sheet
Sensing element/Differential
■Output characteristics■
↑Output voltage(mV)
Output span voltage
Offset voltage
-Rated pressure
0kPa
Rated pressure
Atomospheric
pressure
→Pressure(kPa)
Pressure(kPa) =Port1 pressure - Port2 pressure
(Port1 pressure > Port2 pressure)
Output refers to pressure at pressure port2.
Note ;
Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
Please set Zero-calibration function up your products. The offset voltage may be shifted some mechanical stress
such as mounting, installation and etc. over longtime using.
4
FDM Data sheet
Sensing element/Differential
Reflow Soldering process recommendation profile
Package
Surface
Temperature
(Degree C)
230
210
150
Room
Temp.
Time
a
a: Rump up rate
b: Pre-heating
c: Rump up rate
d: Heating
e: Rump down rate
Note ;
b
c
d
e
1 or 2 deg.C/sec.
150 to 180 deg.C,within 60 to120sec.
1 to 2 deg.C/sec.
max.230 deg.C,max.10sec. 210 deg.C,within 30sec.
1 or 2 deg.C/sec.
1 ) Temperature means Surface temperature of the sensor package.
2 ) Reflow process max. 2 times.
3 ) Do not wash the sensor.
4 ) Do not put the solder and flux on the sensor package.
If you have any questions regarding technical issues or specifications, please contact us.
Fujikura Ltd. Sensor Department
5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072
E-mail : [email protected]
5