FDM Data sheet Sensing element/Differential ■Features Differential pressure,Surface mount package ■Ordering Information FDM-07P D SR Terminal leads configuration Model Surface mount package Pressure type D:Differential pressure Rated Pressure (PSI) Weight (grams) RoHS compliance 1.2 Measurable pressure range(kPa) -13.79 to 13.79 -34.47 to 34.47 -48.26 to 48.26 -103.4 to 103.4 -206.8 to 206.8 -344.7 to 344.7 -482.6 to 482.6 -827.4 to 827.4 Part number FDM-02PDSR FDM-05PDSR FDM-07PDSR FDM-15PDSR FDM-30PDSR FDM-50PDSR FDM-70PDSR FDM-120PDSR ■Specifications Model 02PD Recommended operating conditions Pressure type Rated pressure Measurable pressure range Temperature range Pressure media Excitation current (Constant) 13.79 -13.79 to 13.79 05PD 07PD 34.47 -34.47 to 34.47 48.26 -48.26 to 48.26 15PD 30PD 50PD Differential pressure 103.4 206.8 344.7 -103.4 -206.8 -344.7 to 103.4 to 206.8 to 344.7 0 to 50 Non-corrosive gases only (No liquid) 1.5 70PD 120PD 482.6 -482.6 to 482.6 827.4 -827.4 to 827.4 Unit kPa kPa deg.C mADC Absolute maximum rating Maximum differential pressure **1 Port1 Maximum load pressure Port2 Maximum load pressure Maximum excitation current Operating temperature Storage temperature Operating humidity Twice of rated pressure 3.0 -20 to 100 -40 to 120 30 to 80 (Non dew condition) Electric characteristics (Drive Current 1.5mA constant ,ambient temperature Ta=25deg.C) Output span voltage **2 60 to 140 (at 0kPa to rated pressure) Offset voltage **2 +/-20 (at 0kPa) Bridge resistance 4000 to 6000 Response time 2 (for the reference) Accuracy TSO* +/-5 TCS* 2.5 Linearity +/-0.5 +/-0.3 Pressure hysteresis +/-0.4 +/-0.2 *TSO : Temperature sensitivity of offset voltage(Temperature range from 0-50 deg.C) *TCS : Temperature coefficient of output span voltage(Temperature range from 0-50 deg.C) **1 Port1 pressure > Port2 pressure , Port2 pressure : reference pressure **2 Output refers to pressure at pressure port2. 1 1.5 times of rating pressure mADC deg.C deg.C %RH mV mV Ω msec. %FS/050deg.C +/-0.5 +/-0.6 +/-0.4 %FS %FS FDM Data sheet Sensing element/Differential Pressure(kPa) =Port1 pressure - Port2 pressure P1= 0 kPa P2= 1/2 x P3 (kPa) P3= reted pressure (kPa) T1= 0 deg.C T2= 25 deg.C T3= 50 deg.C Offset voltage (mV) Voff = V(P1,T) Voff(0) = V(P1,T1) Voff(25) = V(P1,T2) Voff(50) = V(P1,T3) Output voltage at full scale (mV) Vfs = V(P3,T) Vfs(0) = V(P3,T1) Vfs(25) = V(P3,T2) Vfs(50) = V(P3,T3) Output span voltage (mV) SV = Vfs - Voff SV(0) = Vfs(0) - Voff(0) SV(25) = Vfs(25) - Voff(25) SV(50) = Vfs(50) - Voff(50) Temperature sensitivity of offset voltage (%FS) TSO = {LARGER ONE} / SV(25) x 100 LARGER ONE = larger absolute value which of {Voff(0) - Voff(25)} and {Voff(50) - Voff(25)} Temperature coefficient of output span voltage (%FS) TCS = {max[SV(0),SV(25),SV(50)] - min[SV(0),SV(25),SV(50)] } / SV(25) x 100 Linearity (%FS) NL = {V(P2,T2) - [Voff(25)+Vfs(25)]/2 } / SV(25) x 100 Pressure hysteresis (%FS) Phys = {Voff’(25) - Voff(25) } / SV(25) x 100 Voff’(25) : Output voltage against P1 after stressing by P3 pressure. 2 FDM Data sheet Sensing element/Differential ■Outline dimensions■ ■Connection diagram■ 3 FDM Data sheet Sensing element/Differential ■Output characteristics■ ↑Output voltage(mV) Output span voltage Offset voltage -Rated pressure 0kPa Rated pressure Atomospheric pressure →Pressure(kPa) Pressure(kPa) =Port1 pressure - Port2 pressure (Port1 pressure > Port2 pressure) Output refers to pressure at pressure port2. Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. Please set Zero-calibration function up your products. The offset voltage may be shifted some mechanical stress such as mounting, installation and etc. over longtime using. 4 FDM Data sheet Sensing element/Differential Reflow Soldering process recommendation profile Package Surface Temperature (Degree C) 230 210 150 Room Temp. Time a a: Rump up rate b: Pre-heating c: Rump up rate d: Heating e: Rump down rate Note ; b c d e 1 or 2 deg.C/sec. 150 to 180 deg.C,within 60 to120sec. 1 to 2 deg.C/sec. max.230 deg.C,max.10sec. 210 deg.C,within 30sec. 1 or 2 deg.C/sec. 1 ) Temperature means Surface temperature of the sensor package. 2 ) Reflow process max. 2 times. 3 ) Do not wash the sensor. 4 ) Do not put the solder and flux on the sensor package. If you have any questions regarding technical issues or specifications, please contact us. Fujikura Ltd. Sensor Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected] 5