SESD3Z3V3~SESD3Z12V(SOD-323)2015.09 HT02

^^ϯϯsϯ
THRU
^^ϯϭϮs
dƌĂŶƐŝĞŶƚsŽůƚĂŐĞ^ƵƉƉƌĞƐƐŽƌƐĨŽƌ^WƌŽƚĞĐƚŝŽŶ
PRIMARY CHARACTERISTICS
PPK
350W
VRWM
5V
IPP
24A
VF
1.25V
TJ,Max
125℃
SOD-323
PACKAGE
0DUNLQJ&RGH Please refer to the specification
([6(6'=9
='
FEATURES
APPLICATIONS

Small Body Outline Dimensions

350 Watts peak pulse power (tp =

Cellular Phone Handsets and
Accessories
8/20μs)

Microprocessor based equipment

Transient protection for data lines to

Personal Digital Assistants(PDA’S)

Small package for use in portable

Notebooks, Desktops, and Servers
electronics

Portable Instrumentation
Suitable replacement for MLV’s in

Pagers Peripherals
ESD protection applications
Complies with the following standards

Protects one I/O or power line
IEC61000-4-2

Low clamping voltage
Level 4 15 kV (air discharge)

Low leakage current

Solid-state silicon-avalanche
MIL STD 883E - Method 3015-7 Class 3
technology
25 kV HBM (Human Body Model)

8 kV(contact discharge)
GENERAL DESCRIPTION
The SESD3Z series is designed to protect voltage sensitive components from ESD and transient
voltage events. Excellent clamping capability, low leakage, and fast response time, make these parts
ideal for ESD protection on designs where board space is at a premium.
2015.0ϵ
www.willas.com.tw
Rev.,d0Ϯ
^^ϯϯsϯ
THRU
^^ϯϭϮs
dƌĂŶƐŝĞŶƚsŽůƚĂŐĞ^ƵƉƉƌĞƐƐŽƌƐĨŽƌ^WƌŽƚĞĐƚŝŽŶ
Electrical Parameter
Symbol
Parameter
IPP
Maximum Reverse Peak Pulse Current
VC
Clamping Voltage @ IPP
VRWM
IR
IT
VBR
Working Peak Reverse Voltage
Maximum Reverse Leakage Current @
VRWM
Test Current
Breakdown Voltage @ IT
IF
Forward Current
VF
Forward Voltage @ IF
Electrical Characteristics Ratings at 25°C ambient temperature unless otherwise specified.
VBR
Part Numbers
Min
Typ
VF
Max
IT
VRWM
IR
Max.
C
IF
Typ.
(Note1)
0DUNLQJ
V
V
V
mA
V
µA
V
mA
pF
SESD3Z3V3
5.0
6.0
7.0
1.0
3.3
1
1.25
200
35
ZD
SESD3Z5V
6.1
6.7
7.2
1.0
5.0
1
1.25
200
30
5V
SESD3Z12V
13.3
14.0
14.7
1.0
12.0
1
1.25
200
25
6U
1、Capacitance is measured at f=1MHz, VR=0V,TA=25℃.
Fig.1 Non-Repetitive Peak Pulse Power vs. Pulse Time
2015.0ϵ
www.willas.com.tw
Rev.,d0Ϯ
^^ϯϯsϯ
THRU
^^ϯϭϮs
dƌĂŶƐŝĞŶƚsŽůƚĂŐĞ^ƵƉƉƌĞƐƐŽƌƐĨŽƌ^WƌŽƚĞĐƚŝŽŶ
Fig.2
Power Derating Curve
Fig.4 Clamping Voltage vs. Peak Pulse Current
Fig.6
2015.0ϵ
Fig.3
Waveform
Fig.5 Capacitance vs. Reverse Voltage
Forward Voltage vs. Forward Current
www.willas.com.tw
Rev.,d0Ϯ
^^ϯϯsϯ
THRU
^^ϯϭϮs
dƌĂŶƐŝĞŶƚsŽůƚĂŐĞ^ƵƉƉƌĞƐƐŽƌƐĨŽƌ^WƌŽƚĞĐƚŝŽŶ
Outline Drawing
SOD-323
.075(1.90)
.059(1.50)
.045(1.15)
.010(0.25)
.016(0.40)
.091(2.30)
.057(1.45)
.106(2.70)
.043(1.10)
.031(0.80)
.004(0.10)MAX.
.008(0.20)
.004(0.10)
.016(0.40)
.010(0.25)
.010(0.25)MIN.
Dimensions in inches and (millimeters)
2015.0ϵ
www.willas.com.tw
Rev.C
Rev.,d0Ϯ
dƌĂŶƐŝĞŶƚsŽůƚĂŐĞ^ƵƉƉƌĞƐƐŽƌƐĨŽƌ^WƌŽƚĞĐƚŝŽŶ
Suggested Soldering Pad Layout
^^ϯϯsϯ
THRU
^^ϯϭϮs
SOD-323
.057(1.45)
.033(0.83)
.027(0.70)
Dimensions in inches and (millimeters)
2015.0ϵ
www.willas.com.tw
RevA
Rev.,d0Ϯ
^^ϯϯsϯ
THRU
^^ϯϭϮs
dƌĂŶƐŝĞŶƚsŽůƚĂŐĞ^ƵƉƉƌĞƐƐŽƌƐĨŽƌ^WƌŽƚĞĐƚŝŽŶ
Reel Taping Specification - Surface Mount Device/SOD-323
PACKAGE
PER REEL EA
REEL DIA (m/m)
PER BOX EA
PER CARTION EA
SOD-323
3000
178
30000
240,000
2015.0ϵ
www.willas.com.tw
Rev.,d0Ϯ
dƌĂŶƐŝĞŶƚsŽůƚĂŐĞ^ƵƉƉƌĞƐƐŽƌƐĨŽƌ^WƌŽƚĞĐƚŝŽŶ
^^ϯϯsϯ
THRU
^^ϯϭϮs
Ordering Information: Device PN Part Number ‐T(1)G(2)‐WS Note: (1) Packing code, Tape & Reel Packing Tape&Reel: 3 Kpcs/Reel (2) RoHS product for packing code suffix ”G”;Halogen free product for packing code suffix “H” ***Disclaimer*** WILLAS reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. WILLAS or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on WILLAS data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. WILLAS does not assume any liability arising out of the application or use of any product or circuit. WILLAS products are not designed, intended or authorized for use in medical, life‐saving implant or other applications intended for life‐sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of WILLAS. Customers using or selling WILLAS components for use in such applications do so at their own risk and shall agree to fully indemnify WILLAS Inc and its subsidiaries harmless against all claims, damages and expenditures. 2015.0ϵ
www.willas.com.tw
Rev.,d0Ϯ