^^ϭϰ^ THRU ^^ϭϮϬ^ ϭ͘Ϭ^ƵƌĨĂĐĞDŽƵŶƚ^ĐŚŽƚƚŬLJĂƌƌŝĞƌZĞĐƚŝĨŝĞƌͲϰϬΕϮϬϬs FEATURES MECHANICAL DATA Metal silicon junction,majority carrier Case:Molded plastic,SOD-123S conduction Polarity:Shown above Low power loss,high efficiency Terminals :Plated terminals, High forward surge current capability solderable per MIL-STD-750,Method The plastic package carries 2026 Underwriters Laboratory Flammability Epoxy : UL94-V0 rated flame Classification 94V-0 retardant Moisture Sensitivity Level 1 SOD-123S PACKAGE SCHEMATIC & PIN CONFIGURATION Marking : Please See Table Ex : SS14S 1 ?. 2 1 2 Maximum Ratings and Electrical Characteristics @TA=25℃ unless otherwise specified Single Phase,half wave,60Hz,resistive or inductive load.For capacitive load,derate current by 20%. RATINGS Max. Reverse Breakdown Voltage SYMBOL VRM SS14S 40 SS16S 60 Maximum RMS Volts VRMS 28 Maximum DC Blocking Voltage VDC 40 Maximum Average forward output rectified current I(AV) 1.0 Amps IFSM 30 Amps Peak forward surge current 8.3ms singlesine-wave superimposed on rated load(JEDECMethod) Typical junction capacitance (NOTE 1) CJ TJ Operating Storage Temperature Range SS110S 100 SS115S 150 SS115SL 150 SS120S 200 UNITS Volts 42 70 105 105 140 Volts 60 100 150 150 200 80 110 -55 ~ +125 pF -55 ~ +150 ℃ -55 ~ +150 TSTG Storage Temperature Range Volts ℃ ELECTRICAL CHARACTERISTICS (At TA = 25℃ unless otherwise noted) CHARACTERISTICS Marking Code Max.Forward Voltage(Condition:IF=1A) Max. DC Reverse Current rated DC blocking voltage per leg SYMBOL VF @TA = 25℃ @TA =100℃ Note:1.Measured at 1MHZ and applied reverse voltage of 4.0V D.C. 2016.06 IR SS14S 14/K4 0.55 SS16S D16/D6 0.7 0.5 10 www.willas.com.tw SS110S D110/D10 0.85 SS115S D115/D15 0.9 SS115SL D115U 0.92 0.2 5 2 SS120S D120/D20 0.95 UNITS Volts mAmps Rev.HT04 ^^ϭϰ^ THRU ^^ϭϮϬ^ FIG. 1- FORWARD CURRENT DERATING CURVE 1 0.8 Single Phase Half Wave 60Hz Resistive or inductive Load 0.6 0.4 SS14S-SS16S SS110S-SS120S 0.2 0 0 25 50 75 100 125 150 175 PEAK FORWARD SURGE CURRENT, AMPERES AVERAGE FORWARD RECTIFIED CURRENT, AMPERES ϭ͘Ϭ^ƵƌĨĂĐĞDŽƵŶƚ^ĐŚŽƚƚŬLJĂƌƌŝĞƌZĞĐƚŝĨŝĞƌͲϰϬΕϮϬϬs FIG. 2-MAXIMUM NON-REPETITIVE PEAK FORWARD SURGE CURRENT 30 8.3ms SINGLE HALF SINE-WAVE (JEDEC Method) 25 20 15 10 5.0 0 1 10 FIG. 3-TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS 20 10 1 TJ =25 C PULSE WIDTH=300 µs 1%DUTY CYCLE SS14S SS16S SS110S-SS115S SS120S 0.1 0.01 0.2 0.4 0.6 0.8 1.0 100 NUMBER OF CYCLES AT 60 Hz 1.1 INSTANTANEOUS REVERSE CURRENT, MILLIAMPERES INSTANTANEOUS FORWARD CURRENT,AMPERES AMBIENT TEMPERATURE, C FIG. 4-TYPICAL REVERSE CHARACTERISTICS 100 10 TJ=100 C 1 TJ=75 C 0.1 TJ=25 C 0.01 0.001 INSTANTANEOUS FORWARD VOLTAGE, VOLTS 0 20 40 60 80 100 PERCENT OF PEAK REVERSE VOLTAGE,% JUNCTION CAPACITANCE, pF FIG. 5-TYPICAL JUNCTION CAPACITANCE 2000 1000 SS14S SS16S-SS120S 100 TJ=25 C 10 0.1 1.0 10 100 REVERSE VOLTAGE,VOLTS 2016.06 www.willas.com.tw Rev.HT04 ^^ϭϰ^ THRU ^^ϭϮϬ^ ϭ͘Ϭ^ƵƌĨĂĐĞDŽƵŶƚ^ĐŚŽƚƚŬLJĂƌƌŝĞƌZĞĐƚŝĨŝĞƌͲϰϬΕϮϬϬs .009(0.22) .004(0.10) .029(0.75) SOD-123S .053(1.35) .119(3.00) .099(2.51) .079(2.00) .054(1.38) Outline Drawing .055(1.40) .032(0.81) .153(3.90) .137(3.50) .033(0.85) .010(0.25) Dimensions in inches and (millimeters) 2016.06 www.willas.com.tw Rev.F Rev.HT04 ^^ϭϰ^ THRU ^^ϭϮϬ^ ϭ͘Ϭ^ƵƌĨĂĐĞDŽƵŶƚ^ĐŚŽƚƚŬLJĂƌƌŝĞƌZĞĐƚŝĨŝĞƌͲϰϬΕϮϬϬs Suggested Soldering Pad Layout SOD-123S . 0 9 1 ( 2 . 31 ) .045 ( 1 . 3 8 ) .038(0.97) Dimensions in inches and (millimeters) 2016.06 www.willas.com.tw RevA Rev.HT04 ϭ͘Ϭ^ƵƌĨĂĐĞDŽƵŶƚ^ĐŚŽƚƚŬLJĂƌƌŝĞƌZĞĐƚŝĨŝĞƌͲϰϬΕϮϬϬs ^^ϭϰ^ THRU ^^ϭϮϬ^ Ordering Information: Device PN Part Number -T(1) G (2)-WS Note: (1) Packing code, Tape & Reel Packing Packing Tape&Reel: 3 Kpcs/Reel (2) RoHS product for packing code suffix ”G”;Halogen free product for packing code suffix “H” ***Disclaimer*** WILLAS reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. WILLAS or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on WILLAS data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. WILLAS does not assume any liability arising out of the application or use of any product or circuit. WILLAS products are not designed, intended or authorized for use in medical, life‐saving implant or other applications intended for life‐sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of WILLAS. Customers using or selling WILLAS components for use in such applications do so at their own risk and shall agree to fully indemnify WILLAS Inc and its subsidiaries harmless against all claims, damages and expenditures. 2016.06 www.willas.com.tw Rev.HT04