Product PDF

1.6-3.8kW Single-Phase Basic PDU, 100-240V 20A (2
C19, 12 C13), C20 & L6-20P Adapter, 12ft Cord, 1U
Rack-Mount
Highlights
Basic single phase 16/20A
100-240V PDU
1U horizontal rackmount
installation
MODEL NUMBER: PDUH20DV
C20 input with NEMA L6-20P
adapter; 12 ft. / 3.7m line cord
2 C19 and 12 C13 outlets
Reversible housing; 3.75 in. /
9.5cm depth
Package Includes
PDUH20DV PDU rackmount PDU
Owner's manual
Description
Tripp Lite Basic Power Distribution Units / PDU systems offer reliable rackmount power distribution for critical IT equipment in wiring closets, server rooms and
equipment racks. Supplies continuous power from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal
housing and secure rackmount installation with included mounting accessories.
Features
16/20A single phase 100-240V Basic Power Distribution Unit / PDU (Agency de-rated to 16A continuous)
C20 inlet with included C19 to C20 input cable, includes L6-20P adapter
14 outlets (2 C19, 12 C13)
12 ft. / 3.7m line cord
1U horizontal rackmount format installs in one rack space
Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formats
Mounting ears are reversible for front or rear facing rackmount installation
Back panel grounding lug
Specifications
OVERVIEW
PDU Type
Basic
OUTPUT
Output Capacity Details
3.84kW (240V), 3.68kW (230V), 3.52kW (220V), 3.33kW (208V), 3.2kW (200V), 2.03kW (127V), 1.92kW (120V),
1.6kW (100V) / 16A total capacity; 16A max per C19 outlet; 12A (10A CE) max per C13 outlet
1/3
Frequency Compatibility
50 / 60 Hz
Output Receptacles
(12) C13; (2) C19
Output Nominal Voltage
100; 120; 127; 200; 208; 220; 230; 240
Overload Protection
n/a
INPUT
PDU Input Voltage
100; 120; 127; 200; 208; 220; 230; 240
Recommended Electrical Service
20A 120V; 20A 208/240V; 16A 230V
Maximum Input Amps
20
Maximum Input Amps Details
Agency de-rated to 16A continuous
PDU Plug Type
NEMA L6-20P; IEC-320 C20
Input Cord Details
Input cable is detachable PDU C20 inlet
Input Cord Length (ft.)
12
Input Cord Length (m)
3.7
Input Phase
Single-Phase
USER INTERFACE, ALERTS & CONTROLS
Switches
n/a
PHYSICAL
Minimum Required Rack Depth
(inches)
6.8
Minimum Required Rack Depth (cm)
17.1
Shipping Dimensions (hwd / in.)
2.25 x 20.5 x 9.5
Shipping Dimensions (hwd / cm)
5.7 x 52.1 x 24.1
Shipping Weight (lbs.)
5.7
Shipping Weight (kg)
2.6
Unit Dimensions (hwd / in.)
1.75 x 17.25 x 3.75
Unit Dimensions (hwd / cm)
4.45 x 43.8 x 9.5
Unit Weight (lbs.)
3.75
Unit Weight (kg)
1.7
Material of Construction
Metal
Form Factors Supported
1U rackmount, 0U vertical rackmount, wall-mount, and under-counter installation
PDU Form Factor
Horizontal (1U, 2U, etc)
Outlets Measurement (Center to
Center)
Distance between front (C13) outlets = 28.75mm; Distance between rear (C19) outlets = 55mm; Distance between
rear (C13) outlets = 28.75mm
2/3
ENVIRONMENTAL
Storage Temperature Range
5 to 122F (-15 to 50C)
Relative Humidity
5 to 95% non-condensing
Operating Elevation (ft.)
0-10,000
Operating Elevation (m)
0-3000
SPECIAL FEATURES
TVSS Grounding
Rear panel grounding lug
CERTIFICATIONS
Certifications
Tested to UL 60950 (USA), CSA (Canada), CE (EU), RoHS Compliant
WARRANTY
Product Warranty Period (Worldwide)
5-year limited warranty
© 2016 Tripp Lite. All rights reserved. All product and company names are trademarks or registered trademarks of their respective holders. Use of them does
not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.
Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite's testing agencies:
http://www.tripplite.com/products/product-certification-agencies
3/3