Datenblatt

For more information, please visit the product page.
date 06/2012
page 1 of 4
DESCRIPTION: ELECTRET CONDENSER
MICROPHONE
PART NUMBER: CMI-4537-SN69
SPECIFICATIONS
parameter
conditions/description
directivity
unidirectional
sensitivity
f= 1 KHz, 1Pa 0 dB= 1 V/Pa
min
nom
max
-40
-37
-34
dB
1.5
9
V dc
1.8
2.34
operating voltage
output impedance
f= 1 KHz, 1Pa
sensitivity reduction
f= 1 KHz, 1Pa Vs=1.5 V dc to 1.1 V dc
1.26
-3
frequency
100
current consumption
Vs=1.5 V dc RL=2.0 KΩ
signal to noise ration
f= 1 KHz, 1 Pa A weighted
units
KΩ
dBA
12,000
Hz
0.4
mA
69
dBA
operating temperature
-20
70
°C
storage temperature
-20
70
°C
0.8
g
dimenstions
ø9.7 x H4.5 mm
weight
material
Aluminum
terminal
terminal type
RoHS
yes
APPEARANCE DRAWING
4.5
TERMINAL 2
TERMINAL 1
9.7
1.0
(6 PLCS)
20050 SW 112th Ave. Tualatin, Oregon 97062
phone 503.612.2300
fax 503.612.2383 www.cui.com
For more information, please visit the product page.
date 06/2012
page 2 of 4
PART NUMBER: CMI-4537-SN69
DESCRIPTION: ELECTRET CONDENSER
MICROPHONE
FREQUENCY RESPONSE CURVE
MEASUREMENT CIRCUIT
20050 SW 112th Ave. Tualatin, Oregon 97062
phone 503.612.2300
fax 503.612.2383 www.cui.com
For more information, please visit the product page.
date 06/2012
page 3 of 4
DESCRIPTION: ELECTRET CONDENSER
MICROPHONE
PART NUMBER: CMI-4537-SN69
MECHANICAL CHARACTERISTICS
item
test condition
evaluation standard
soldering heat resistance
Soldering iron with 270 ±5°C should be applied on the terminal for
2 ±0.5 seconds.
No interference in operation.
PCB wire pull strength
The force of 4.9 N is applied for 30 sec. to double lead wire.
No damage or cutting off.
vibration test
The microphone should be measured after a vibration amplitude
of 1.5 mm with 10 ~ 55 Hz band of vibration frequency to each of
the 3 perpendicular directions for 2 hours.
drop test
The microphone without packaging is subjected to 3 drops on
each axis from the height of 1 m onto a 10 mm thick wooden
board.
The sensitivity should be within
±3dB compared with the initial
measurement.
ENVIRONMENT TEST
item
test condition
high temperature test
After being placed in a chamber at +70°C for 72 hours.
evaluation standard
low temperature test
After being placed in a chamber at -20°C for 72 hours.
humidity test
After being placed in a chamber at +40°C and 90 ±5% RH for
240 hours.
temperature cycle test
The part will be subjected to 10 cycles. One cycle will consist of:
+70к
+25к
+25к
-20к
1hr
0.5hr
1hr
0.5hr
1hr
0.5hr
The microphone will be measured
after being placed at +25°C for 6
hours. The value of the oscillation
frequency should be ±10% compared
to the initial measurements. The SPL
should be within ±3dB compared to
the initial measurements.
1hr
5.5 hrs
TEST CONDITIONS
standard test conditions
a) Temperature: +5 ~ +35°C
b) Humidity: 45 ~ 85%
c) Pressure: 860 ~ 1060 mbar
judgement test conditions
a) Temperature: +25 ±2°C
b) Humidity: 60 ~ 70%
c) Pressure: 860 ~ 1060 mbar
20050 SW 112th Ave. Tualatin, Oregon 97062
phone 503.612.2300
fax 503.612.2383 www.cui.com
For more information, please visit the product page.
date 06/2012
page 4 of 4
DESCRIPTION: ELECTRET CONDENSER
MICROPHONE
PART NUMBER: CMI-4537-SN69
PACKAGING
ʳ˥̂˛˦ʳ˖̂̀̃˿˼˴́̇ʳʳ
Small box
Middle box
Carton size
100mm*100mm*10mm
205mm*105mm*50mm
420mm*230mm*255mm
20050 SW 112th Ave. Tualatin, Oregon 97062
phone 503.612.2300
100PCS/ Small box
1000PCS/ Middle box
20000PCS/ Carton
fax 503.612.2383 www.cui.com