Specification of Electret Condenser Microphone

Specification of
Electret Condenser Microphone
Model No.:
Date:
EM6022P
SEP
02
2009
APPROVER
CHECKER
DESIGN
Hu Guo Feng
REN WEI
XIA YING BO
211 N. First Street
Minneapolis, MN. 55401
612-849-6205
www.soberton.com /
[email protected]
Page 1 of 6
Type: Omni directional Back Electret Condenser Microphone
Model Number: EM6022P
1. Electrical Characteristics
(Temperature =20±2℃
No
Parameter
1.1
1.2
1.3
Sensitivity
Output impedance
Current Consumption
S
Z out
IDSS
1.4
Signal to Noise Ratio
S/N
1.5
5
1.7
Decreasing Voltage
Operating Voltage
Maximum input S.P.L
ΔS
2.
Symbol
Condition
Min.
0dB=1V/Pa,at 1kHz
f=1kHz
VCC =2.0V,RL=2.2KΩ
at 1kHz S.P.L=1Pa
(A-Weighted Curve)
VCC=3.0V to2.0V
-47
Limits
Center Max.
-44
-41
2.2
500
58
Unit
dB
KΩ
µA
dB
-3
10
110
1.0
dB
V
dB
Typical Frequency Response Curve
Frequency Response
3.
Humidity=65±5%)
Microphone Response Tolerance Window
Frequency(Hz)
Lower Limit(dB)
Upper
Limit(dB)
50
100
800
1000
1200
3000
5000
10000
-6
-3
-3
0
-3
-3
-3
-8
+3
+3
+3
0
+3
+8
+8
+8
Measurement Circuit
RL=2.2KΩ
VS =2.0V
C=1µF
Page 2 of 6
4. Measurement Setup Drawing
5. Appearance And Dimension
Unit:mm
6. Material And Structure
10
PIN
1
9
FET
1
8
PCB
7
Copper ring
1
6
Chamber
1
5
Electret Plate
1
4
Spacer
1
3
Diaphragm
1
2
Case
Al-Mg alloy
1
1
Dustproof gauze
Non-weave cloth
1
Name
material
No.
FR4
1
QTY
Remark
Page 3 of 6
7. Temperature Conditions
Storage Temperature Range
-40℃
~
Operation Temperature Range
+75℃
-20℃ ~
+60℃
8. Terminal Mechanical Strength
Terminal should be no interference in operation after pulled the terminal with 1kg for 1 minute.
9. Reliability Test
After each of following test, the sensitivity of the microphone should be within ±3dB of initial sensitivity after
3hours of conditioning at 20℃.
1. Vibration Test
Frequency : 10Hz~55Hz
Amplitude : 1.52mm
Change of Frequency : 1 octave/min
2 hours in each of axes
2. High Temperature Test
+70℃ for 72 hours.
3. Low Temperature Test
-20℃ for
72 hours.
4. Humidity Test
90%~95%RH,+40℃ for 240 hours.
5. Temperature Cycles
-20℃
(2h) (1h)
25℃
70℃
(2h)
(1h) (2h)
(2h)
-20℃
for 10 cycles.
6 Packing Drop Test
Height:1m
Procedure: 5 times from each of axes
10. Soldering Condition
1.
We suggest using anti-static welding machine which can control soldering temperature automatically.
2.
Soldering temperature should be controlled under 320℃ and
sec..
3.
Microphone should be fixed on the metal block (heat sink), which has high radiation effects, and heat sink
shall contact with MIC tightly.
4.
Microphone may easily be destroyed by the static electricity and the countermeasure for eliminating the static
electricity shall be executed (worktable and human body shall be ground connection).
soldering time for each terminal should be 1~2
Page 4 of 6
5.
Heat Sink
Shape of heat sink
Shape of hole at fixed part
11. Code Explanation
EXPLANATION
Omni-directional Mic
Back Electret
D= 6.0mm
T=2.2mm
PCB version No.4
Dash
Sensitivity –44±3dB
Test Condition 2.2KΩ/2.0V
Dash
PIN=2.8m
NO Capacitance
Dash
NO Rubber
Dash
No especial require
Page 5 of 6
Packing
12. Packing
chart
1. MODEL NUMBER :
EM6022P-44-LF
2. DIMENSION:(LENGTH*WIDTH *HEIGHT)
2.1 PLASTIC TRAY
100mm*100mm*10mm
2.2 MIDDLE BOX:
205mm*105mm*50mm
2.3 CARTON SIZE:
550mm*230mm*235mm
3. QUANTITY AND WEIGHT
3.1 100PCS/ PLASTIC TRAY
3.2 1400PCS/MID BOX
3.3 28000PCS/CARTON
3.4 1PC=0.1g
3.5 NET WEIGHT:2.8 kg
3.6 GROSS WEIGHT:5.0kg
X1
100PCS
4. LABEL STIPULATION
4.1 CONTENTS SHOULD BE SEEN CLEAR.
X14
1400PCS
X20
28000PCS
Page 6 of 6