AS4PD, AS4PG, AS4PJ, AS4PK, AS4PM www.vishay.com Vishay General Semiconductor High Current Density Standard Avalanche Surface Mount Rectifiers FEATURES • Very low profile - typical height of 1.1 mm eSMP ® Series Available • Ideal for automated placement • Glass passivated pellet chip junction K • Controlled avalanche characteristics • Low leakage current • High forward surge capability 1 • Meets MSL level 1, per J-STD-020, LF maximum peak of 260 °C 2 TO-277A (SMPC) • AEC-Q101 qualified available - Automotive ordering code: base P/NHM3 Anode 1 K Cathode • Material categorization: for definitions of compliance please see www.vishay.com/doc?99912 Anode 2 PRIMARY CHARACTERISTICS MECHANICAL DATA IF(AV) 4.0 A VRRM 200 V, 400 V, 600 V, 800 V, 1000 V IFSM 100 A EAS 20 mJ VF at IF = 4 A 0.92 V TJ max. 175 °C Package TO-277A (SMPC) Diode variations Single die Case: TO-277A (SMPC) Molding compound meets UL 94 V-0 flammability rating Base P/N-M3 - halogen-free, RoHS-compliant, and commercial grade Base P/NHM3 - halogen-free, RoHS-compliant and AEC-Q101 qualified Base P/NHM3_X - halogen-free, RoHS-compliant and AEC-Q101 qualified (“_X” denotes revision code e.g. A, B,.....) Terminals: Matte tin plated leads, solderable per J-STD-002 and JESD 22-B102 M3 suffix meets JESD 201 class 1A whisker test, HM3 suffix meets JESD 201 class 2 whisker test TYPICAL APPLICATIONS For use in general purpose rectification of power supplies, inverters, converters and freewheeling diodes for consumer, automotive and telecommunication. MAXIMUM RATINGS (TA = 25 °C unless otherwise noted) PARAMETER SYMBOL Device marking code Max. repetitive peak reverse voltage VRRM Peak forward surge current 10 ms single half sine-wave superimposed on rated load Non-repetitive avalanche energy at TJ = 25 °C IAS = 2.5 A max. IAS = 1.0 A typical Operating junction and storage temperature range AS4PG AS4PJ AS4PK AS4PM AS4D AS4G AS4J AS4K AS4M 200 400 600 800 1000 (1) 4.0 IF (2) 2.4 IFSM 100 IF Max. DC forward current (fig. 1) AS4PD EAS TJ, TSTG 20 30 -55 to +175 UNIT V A A mJ °C Notes (1) Mounted on 20 mm x 20 mm pad areas, 1 oz. FR4 PCB (2) Free air, mounted on recommended copper pad area Revision: 19-Feb-16 Document Number: 88770 1 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 AS4PD, AS4PG, AS4PJ, AS4PK, AS4PM www.vishay.com Vishay General Semiconductor ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted) PARAMETER TEST CONDITIONS IF = 2.0 A IF = 4.0 A Instantaneous forward voltage IF = 2.0 A IF = 4.0 A SYMBOL TA = 25 °C VF (1) TA = 125 °C TA = 25 °C TYP. MAX. 0.962 - 1.044 1.10 0.822 - 0.922 0.98 0.35 10 75 150 IR (2) UNIT V Reverse current rated VR Typical reverse recovery time IF = 0.5 A, IR = 1.0 A, Irr = 0.25 A trr 1.8 - μs Typical junction capacitance per diode 4.0 V, 1 MHz CJ 60 - pF AS4PM UNIT TA = 125 °C μA Notes (1) Pulse test: 300 μs pulse width, 1 % duty cycle (2) Pulse test: Pulse width 40 ms THERMAL CHARACTERISTICS (TA = 25 °C unless otherwise noted) PARAMETER SYMBOL RJA Typical thermal resistance AS4PD AS4PG (1) AS4PJ AS4PK 80 RJM (2) °C/W 5 Notes (1) Free air, mounted on recommended PCB 1 oz. pad area; thermal resistance R JA - junction to ambient (2) Units mounted on PCB with 20 mm x 20 mm copper pad areas, 1 oz. FR4 PCB; R JM - junction to mount ORDERING INFORMATION (Example) PREFERRED P/N UNIT WEIGHT (g) PREFERRED PACKAGE CODE BASE QUANTITY AS4PJ-M3/86A 0.10 86A 1500 7" diameter plastic tape and reel AS4PJ-M3/87A 0.10 87A 6500 13" diameter plastic tape and reel AS4PJHM3/86A (1) 0.10 86A 1500 7" diameter plastic tape and reel (1) 0.10 87A 6500 13" diameter plastic tape and reel AS4PJHM3_A/H (1) 0.10 H 1500 7" diameter plastic tape and reel 0.10 I 6500 13" diameter plastic tape and reel AS4PJHM3/87A AS4PJHM3_A/I (1) DELIVERY MODE Note (1) AEC-Q101 qualified Revision: 19-Feb-16 Document Number: 88770 2 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 AS4PD, AS4PG, AS4PJ, AS4PK, AS4PM www.vishay.com Vishay General Semiconductor RATINGS AND CHARACTERISTICS CURVES (TA = 25 °C unless otherwise noted) 1000 4.5 Instantaneous Reverse Current (μA) TM = 155 °C DC Forward Current (A) 4.0 3.5 3.0 TA = 25 °C 2.5 2.0 1.5 1.0 TM Measured at the Cathode Band Terminal 0.5 TA = 175 °C 100 TA = 125 °C 10 TA = 75 °C 1 0.1 TA = 25 °C 0.01 0 0 25 50 75 100 125 150 10 175 20 Fig. 1 - Max. Forward Current Derating Curve 50 60 70 80 90 100 1000 D = 0.8 D = 0.5 D = 0.3 Junction Capacitance (pF) D = 0.2 4.0 3.5 D = 0.1 3.0 D = 1.0 2.5 2.0 T 1.5 1.0 D = tp/T 0.5 TJ = 25 °C f = 1.0 MHz Vsig = 50 mVp-p 100 10 tp 1 0 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 0.1 1 Fig. 2 - Forward Power Loss Characteristics 100 Fig. 5 - Typical Junction Capacitance 100 Transient Thermal Impedance (°C/W) 100 TA = 175 °C TA = 125 °C 10 TA = 75 °C 1 TA = 25 °C 0.1 0.3 10 Reverse Voltage (V) Average Forward Current (A) Instantaneous Forward Current (A) 40 Fig. 4 - Typical Reverse Leakage Characteristics 5.0 4.5 Average Power Loss (W) 30 Percent of Rated Peak Reverse Voltage (%) Mount Temperature (°C) 0.5 0.7 0.9 1.1 1.3 1.5 Instantaneous Forward Voltage (V) Fig. 3 - Typical Instantaneous Forward Characteristics Junction-to-Ambient 10 1 0.1 0.01 0.1 1 10 100 t - Pulse Duration (s) Fig. 6 - Typical Transient Thermal Impedance Revision: 19-Feb-16 Document Number: 88770 3 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 AS4PD, AS4PG, AS4PJ, AS4PK, AS4PM www.vishay.com Vishay General Semiconductor PACKAGE OUTLINE DIMENSIONS in inches (millimeters) TO-277A (SMPC) 0.187 (4.75) 0.175 (4.45) 0.016 (0.40) 0.006 (0.15) K 0.262 (6.65) 0.250 (6.35) 0.242 (6.15) 0.238 (6.05) 2 1 0.047 (1.20) 0.039 (1.00) 0.171 (4.35) 0.167 (4.25) 0.146 (3.70) 0.134 (3.40) Mounting Pad Layout 0.087 (2.20) 0.075 (1.90) 0.189 (4.80) MIN. 0.189 (4.80) 0.173 (4.40) 0.186 (4.72) MIN. 0.268 (6.80) 0.155 (3.94) NOM. 0.030 (0.75) NOM. 0.049 (1.24) 0.037 (0.94) 0.050 (1.27) MIN. 0.084 (2.13) NOM. 0.053 (1.35) 0.041 (1.05) 0.041 (1.04) 0.055 (1.40) MIN. Conform to JEDEC® TO-277A Revision: 19-Feb-16 Document Number: 88770 4 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU. Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21 conform to JEDEC JS709A standards. Revision: 02-Oct-12 1 Document Number: 91000