Sensor PDF(400KB)

Sensor
NON-CONTACT VITAL & MOTION SENSOR MODULE /
IONIZING RADIATION SENSOR MODULE
☆ New
■ Non-contact
product
Vital & Motion Sensor Module
♦Features
(1) Measures heart and breathing rate without contact using the Doppler effect.
(2) The module can be embedded in products as sensing is possible through obstructions
(except in cases where the obstructions are metal or metal plated).
(3) Enables stable measurement without being affected by factors such as temperature,
direct sunlight, or reflector color.
DC6M4JN3000
♦Standard
Specifications
☆DC6M4JN3000
Model No.
Output frequency (GHz)
24.05 to 24.5
Output interface
UART interface (baud rate: 115 200; data bit length: 8 bits)
Applications
Heart rate / Breathing rate / Body motion
Measurable distance (m)
MAX. 1 (heart rate and breathing rate)
Antenna
Planar antenna with 8 patch Tx / Rx antenna elements
Antenna pattern (deg.)
30 (azimuth), 26 (elevation)
Power supply (V)
3.3
Dissipation current (mA)
100 (including signal processing)
RF module: 31 × 47.5 × 14.5
Signal processer: 30.0 × 46.5 × 5.0
Outline dimensions (W)×(D)×(H) (mm)
■ Ionizing
Radiation Sensor Module
♦Features
(1) Low-noise amplifier to efficiently amplify weak currents
(2) Built-in circuit to eliminate noise caused by vibration and shock
(3) Compact module size thanks to a newly developed dedicated IC
(25 × 20 × 2.5 mm)
(4) Low power consumption (7.5 mW at normal operation)
QM1H0M0058
♦Standard
Specifications
Model No.
Object to be detected
Measuring range (µSv/h)
0.05 to 20
Output interface
I2C output
Power supply voltage
78
QM1H0M0058
Gamma ray (γ-ray) (Detector: PIN photodiode)
DC 5 V (Photodiode), 2.75 V (Analog), 1.8 V (Digital)
Power consumption (mW)
7.5 (at normal operation)
Outline dimensions (mm)
25 × 20 × 2.5
Notice
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment
using any SHARP devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets
before using any SHARP device.
PM2.5 SENSOR MODULE /
TEMPERATURE AND HUMIDITY SENSOR
Sensor
☆ New
■ PM2.5
product
Sensor Module
♦Features
(1) Easy assembly for use in air purifiers and other products
thanks to small size of 53 × 40 × 51 mm
(2) Industry’s shortest*1 detection time of 10 seconds
(3) Digital output model is also part of line-up
*1: As of May 1, 2015 (measured by Sharp)
Analog output type: DN7C3CA006 / 007
Digital output type: DN7C3CD015
♦Standard
Specifications
☆DN7C3CD015
[Japan / Overseas]
DN7C3CA006 / 007
[Overseas]
Model No.
Measuring range (μg/m3)
25 to 500
25 to 500
Output type
Analog voltage
Digital PWM
Power supply voltage (Vcc/fan)
DC5 V / DC5 V
DC5 V / DC5 V
At sensor: 55,
At fan: 700 [JA001, CA006]
450 [CA007]
At sensor: 75,
At fan: 450
0 to 3.4 (MIN.)
Vhigh: Vcc-1.5 (MIN.),
Vlow: 1.3 (MAX.)
Power consumption (mW) (TYP.)
Output voltage range (V)
Operating temperature range (°C)
Outline dimensions (mm)
■ Temperature
–10 to +60
–10 to +60
53.0 × 40.0 × 51.0 (excluding protruding parts)
53.0 × 40.0 × 51.0 (excluding protruding parts)
and Humidity Sensor
♦Features
(1) Package: 3.0 x 3.0 x 0.8 mm, reflowable, QFN
(2) High-speed response: Approx. 7 sec.*1
(3) Interface: I2C
QM1H0P0073
♦Standard
Specifications
Humidity sensor
Temperature sensor
Macromolecule capacity
Semiconductor
0 to 100% RH
–20 to +85°C
Accuracy
±2% RH (25°C)
±0.3°C
Resolution
0.01% RH
Type
Measuring range
Interface
SENSOR
*1: For 63% of humidity change
0.02°C
I2C
Notice
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment
using any SHARP devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets
before using any SHARP device.
79
Sensor
■ Barometer
BAROMETER SENSOR
Sensor
♦Features
(1) High sensitive detection: ±0.08 hPa (relative accuracy)
(2) Wide measurement range: 300 to 1 100 hPa
(3) Ultra small, thin SMT package: 2.78 × 2.23 × 0.70 mm
(4) Low power consumption: 750 μA at measurement, 1 μA at idle
QM1H0P0075
♦Standard
Specifications
Model No.
Pressure range (hPa)
300 to 1 100
Absolute accuracy (hPa)
±3
Relative accuracy (hPa)
±0.08
Supply voltage
Dissipation current (μA)
Interface
Operating temperature range (°C)
Outline dimensions (mm)
80
QM1H0P0075
DC1.7 to 3.6 V
750 (at measurement), 1 (at idle)
I2C, SPI
–20 to +85
2.78 × 2.23 × 0.70
Notice
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment
using any SHARP devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets
before using any SHARP device.