UT54ACS279

Standard Products
UT54ACS279/UT54ACTS279
Quadruple S-R Latches
Datasheet
November 2010
www.aeroflex.com/logic
PINOUTS
FEATURES
‰ 1.2μ CMOS
- Latchup immune
‰ High speed
‰ Low power consumption
‰ Single 5 volt supply
‰ Available QML Q or V processes
‰ Flexible package
- 16-pin DIP
- 16-lead flatpack
‰ UT54ACS279- SMD 5962-96580
‰ UT54ACTS279 - SMD 5962-96581
16-Pin DIP
Top View
1R
1
16
VDD
1S1
2
15
4S
1S2
3
14
4R
1Q
2R
4
5
13
12
4Q
3S2
2S
2Q
6
7
11
10
3S1
3R
VSS
8
9
3Q
DESCRIPTION
16-Lead Flatpack
Top View
The UT54ACS279 and the UT54ACTS279 contain four basic
S-R flip-flop latches. Under conventional operation, the S-R
inputs are normally held high. When the S input is pulsed low,
the Q output will be set high. When R is pulsed low, the Q output
will be reset low. If the S-R inputs are taken low simultaneously,
the Q output is unpredictable.
The devices are characterized over full military temperature
range of -55°C to +125°C.
FUNCTION TABLE
INPUTS
OUTPUT
S
R
Q
H
H
Q0
L
H
H
H
L
L
L
L
H1
1
16
VDD
1S1
2
15
4S
1S2
3
14
4R
1Q
2R
4
5
13
4Q
12
3S2
2S
6
11
3S1
2Q
VSS
7
8
10
9
3R
3Q
LOGIC SYMBOL
(1)
1R
(2)
1S1
(3)
1S2
(5)
2R
(6)
2S
(10)
3R
(11)
3S1
(12)
3S2
(14)
4R
(15)
4S
Note:
1. This configuration is nonstable. It may not persist when the S and R inputs
return to their inactive (high) level.
LOGIC DIAGRAM
(LATCHES 1 & 3)
(LATCHES 2 & 4)
R
R
1R
R
S1
S1
R
S2
R
S3
S3
R
S4
(4)
(7)
(9)
(13)
1Q
2Q
3Q
4Q
Note:
1. Logic symbol in accordance with ANSI/IEEE standard 91-1984 and IEC
Publication 617-12.
S1
S2
Q
S
Q
1
OPERATIONAL ENVIRONMENT1
PARAMETER
LIMIT
UNITS
Total Dose
1.0E6
rads(Si)
SEU Threshold 2
80
MeV-cm2/mg
SEL Threshold
120
MeV-cm2/mg
Neutron Fluence
1.0E14
n/cm2
Notes:
1. Logic will not latchup during radiation exposure within the limits defined in the table.
2. Device storage elements are immune to SEU affects.
ABSOLUTE MAXIMUM RATINGS
SYMBOL
PARAMETER
LIMIT
UNITS
VDD
Supply voltage
-0.3 to 7.0
V
VI/O
Voltage any pin
-.3 to VDD +.3
V
TSTG
Storage Temperature range
-65 to +150
°C
TJ
Maximum junction temperature
+175
°C
TLS
Lead temperature (soldering 5 seconds)
+300
°C
ΘJC
Thermal resistance junction to case
20
°C/W
II
DC input current
±10
mA
PD
Maximum power dissipation
1
W
Note:
1. Stresses outside the listed absolute maximum ratings may cause permanent damage to the device. This is a stress rating only, functional operation of the device at
these or any other conditions beyond limits indicated in the operational sections is not recommended. Exposure to absolute maximum rating conditions for extended
periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
SYMBOL
PARAMETER
LIMIT
UNITS
VDD
Supply voltage
4.5 to 5.5
V
VIN
Input voltage any pin
0 to VDD
V
TC
Temperature range
-55 to + 125
°C
2
DC ELECTRICAL CHARACTERISTICS 7
(VDD = 5.0V ±10%; VSS = 0V 6, -55°C < TC < +125°C); Unless otherwise noted, Tc is per the temperature range ordered.
SYMBOL
VIL
VIH
IIN
PARAMETER
CONDITION
MIN
Low-level input voltage 1
ACTS
ACS
High-level input voltage 1
ACTS
ACS
MAX
UNIT
0.8
.3VDD
V
.5VDD
.7VDD
V
Input leakage current
ACTS/ACS
VIN = VDD or VSS
Low-level output voltage 3
ACTS
ACS
IOL = 12.0mA
IOL = 100μA
High-level output voltage 3
ACTS
ACS
IOH = -12.0mA
IOH = -100μA
Short-circuit output current 2 ,4
ACTS/ACS
VO = VDD and VSS
-300
Output current10
VIN = VDD or VSS
12
mA
(Sink)
VOL = 0.4V
Output current10
VIN = VDD or VSS
-12
mA
(Source)
VOH = VDD - 0.4V
Ptotal
Power dissipation 2, 8, 9
CL = 50pF
2.1
mW/
MHz
IDDQ
Quiescent Supply Current
VDD = 5.5V
10
μA
Quiescent Supply Current Delta
For input under test
1.6
mA
VOL
VOH
IOS
IOL
IOH
ΔIDDQ
ACTS
-1
1
μA
0.40
0.25
V
.7VDD
VDD - 0.25
V
300
mA
VIN = VDD - 2.1V
For all other inputs
VIN = VDD or VSS
VDD = 5.5V
CIN
COUT
Input capacitance 5
ƒ = 1MHz @ 0V
15
pF
Output capacitance 5
ƒ = 1MHz @ 0V
15
pF
3
Notes:
1. Functional tests are conducted in accordance with MIL-STD-883 with the following input test conditions: VIH = VIH(min) + 20%, - 0%; VIL = VIL(max) + 0%, 50%, as specified herein, for TTL, CMOS, or Schmitt compatible inputs. Devices may be tested using any input voltage within the above specified range, but are
guaranteed to VIH(min) and VIL(max).
2. Supplied as a design limit but not guaranteed or tested.
3. Per MIL-PRF-38535, for current density ≤ 5.0E5 amps/cm2, the maximum product of load capacitance (per output buffer) times frequency should not exceed 3,765
pF/MHz.
4. Not more than one output may be shorted at a time for maximum duration of one second.
5. Capacitance measured for initial qualification and when design changes may affect the value. Capacitance is measured between the designated terminal and VSS at
frequency of 1MHz and a signal amplitude of 50mV rms maximum.
6. Maximum allowable relative shift equals 50mV.
7. All specifications valid for radiation dose ≤ 1E6 rads(Si).
8. Power does not include power contribution of any TTL output sink current.
9. Power dissipation specified per switching output.
10. This value is guaranteed based on characterization data, but not tested.
4
AC ELECTRICAL CHARACTERISTICS 2
(VDD = 5.0V ±10%; VSS = 0V 1, -55°C < TC < +125°C); Unless otherwise noted, Tc is per the temperature range ordered.
SYMBOL
PARAMETER
MINIMUM
MAXIMUM
UNIT
tPLH
S to Q
1
15
ns
tPHL
S to Q
1
18
ns
tPHL
R to Q
1
17
ns
Minimum pulse width
S low
R low
8
tW
Notes:
1. Maximum allowable relative shift equals 50mV.
2. All specifications valid for radiation dose ≤ 1E6 rads(Si).
5
ns
PACKAGING
Side-Brazed Packages
6
FLATPACK PACKAGES
7
UT54ACS279/UT54ACTS279: SMD
5962 * ***** ** * * *
Lead Finish: (Notes 1 & 2)
A = Solder
C = Gold
X = Optional
Package Type:
X = 16-lead ceramic bottom-brazed dual-in-line Flatpack
C = 16-lead ceramic side-brazed dip
Class Designator:
Q = QML Class Q
V = QML Class V
Device Type:
01
Drawing Number:
96580 = UT54ACS279
96581 = UT54ACTS279
Total Dose: (Notes 3 & 4)
R = 1E5 rads(Si)
F = 3E5 rads(Si)
G = 5E5 rads(Si)
H = 1E6 rads(Si)
Notes:
1. Lead finish (A,C, or X) must be specified.
2. If an “X” is specified when ordering, part marking will match the lead finish and will be either “A” (solder) or “C” (gold).
3. Total dose radiation must be specified when ordering. QML Q and QML V not available without radiation hardening. For prototype inquiries, contact factory.
4. Device type 02 is only offered with a TID tolerance guarantee of 3E5 rads(Si) or 1E6 rads(Si) and is tested in accordance with MIL-STD-883 Test Method 1019
Condition A and section 3.11.2. Device type 03 is only offered with a TID tolerance guarantee of 1E5 rads(Si), 3E5 rads(Si), and 5E5 rads(Si), and is tested in
accordance with MIL-STD-883 Test Method 1019 Condition A.
8
Aeroflex Colorado Springs - Datasheet Definition
Advanced Datasheet - Product In Development
Preliminary Datasheet - Shipping Prototype
Datasheet - Shipping QML & Reduced Hi-Rel
COLORADO
Toll Free: 800-645-8862
Fax: 719-594-8468
INTERNATIONAL
Tel: 805-778-9229
Fax: 805-778-1980
NORTHEAST
Tel: 603-888-3975
Fax: 603-888-4585
SE AND MID-ATLANTIC
Tel: 321-951-4164
Fax: 321-951-4254
WEST COAST
Tel: 949-362-2260
Fax: 949-362-2266
CENTRAL
Tel: 719-594-8017
Fax: 719-594-8468
www.aeroflex.com
[email protected]
Aeroflex UTMC Microelectronic Systems Inc. (Aeroflex)
reserves the right to make changes to any products and
services herein at any time without notice. Consult Aeroflex
or an authorized sales representative to verify that the
information in this data sheet is current before using this
product. Aeroflex does not assume any responsibility or
liability arising out of the application or use of any product
or service described herein, except as expressly agreed to in
writing by Aeroflex; nor does the purchase, lease, or use of a
product or service from Aeroflex convey a license under any
patent rights, copyrights, trademark rights, or any other of the
intellectual rights of Aeroflex or of third parties.
Our passion for performance is defined by three
attributes represented by these three icons:
solution-minded, performance-driven and customer-focused
9