RadReport MUX8521 (3/10)

March 15, 2010
Radiation Performance Data Package
MUX8521-S
MUX8521-S DSCC SMD Part Number: 5962-0922902KXC
16 channel analog multiplexer,
high impedance analog input,
Kelvin measurement configuration with ESD protection
Prepared by:
Aeroflex Plainview, Inc.
35 South Service Road
Plainview, NY 11803
1. MUX8521-S:
1.1
1.1.1
1.2
Part Description
16 channel analog multiplexer, high impedance analog input, Kelvin measurement configuration
with ESD protection.
Applicable Documents
1.2.1
Appendix A:
Data Sheet:
MUX8521
16-Channel Analog Multiplexer Module,
Radiation Tolerant & ESD Protected
1.2.2
Appendix B:
DSCC SMD:
5962-95630
RADIATION HARDENED, SINGLE 16
CHANNEL ANALOG MUX DIE
1.2.3
Appendix C:
DSCC SMD:
5962-09229
MICROCIRCUIT, HYBRID, LINEAR,
16 CHANNEL, ANALOG MULTIPLEXER
2. Radiation Performance
2.1
2.1.1
2.1.2
2.1.3
2.2
2.2.1
2.2.2
2.3
2.3.1
2.3.2
2.3.3
Total Dose:
300 krads(Si), Dose rate = 50 - 300 rads(Si)/s
Per analog multiplexer IC manufacturer's DSCC SMD Specification.
See Appendix B: DSCC SMD: 5962-95630, sheet 4, Section 1.5 Radiation features.
Every wafer lot is subjected to RLAT testing at the stated total dose and dose rate.
SEU:
Immune up to 120 MeV-cm2/mg
Per analog multiplexer IC manufacturer's DSCC SMD Specification
See Appendix B: DSCC SMD: 5962-95630, sheet 4, Section 1.5 Radiation features.
SEL:
Immune, guaranteed by process design
Per analog multiplexer IC manufacturer's DSCC SMD Specification
See Appendix B: DSCC SMD: 5962-95630, sheet 4, Section 1.5 Radiation features.
See Appendix B: DSCC SMD: 5962-95630, sheet 4, note 3/.
PAGE 2 of 2
Standard Products
MUX8521 16-Channel Analog Multiplexer Module
Radiation Tolerant & ESD Protected
Kelvin Measurement Configured
www.aeroflex.com/mux
April 17, 2009
FEATURES
❑
❑
16 Kelvin measurement channels provided by two 16-channel multiplexers
Radiation performance
- Total dose:
300 krads(Si), Dose rate = 50 - 300 rads(Si)/s
- SEU:
Immune up to 120 MeV-cm2/mg
- SEL:
Immune by process design
❑
Full military temperature range
❑
Low power consumption < 30mW
❑
One address bus (A0-3), and one enable line
❑
All channel inputs protected by ±20V nominal Transorbs
❑
Fast access time 1500ns typical
❑
Break-Before-Make switching
❑
High analog input impedance (power on or off )
❑
❑
❑
Designed for aerospace and high reliability space applications
Packaging – Hermetic ceramic
- 56 leads, 0.80"Sq x 0.20"Ht quad flat pack
- Typical Weight 6 grams
DSCC SMD 5962-09229 pending
Note: Aeroflex Plainview does not currently have a DSCC certified Radiation Hardened Assurance Program.
GENERAL DESCRIPTION
Aeroflex’s MUX8521 is a radiation tolerant, 16 channel multiplexer MCM (Multi Chip Module) with
electrostatic discharge (ESD) protection on all channel inputs.
The MUX8521 has been specifically designed to meet exposure to radiation environments. It is available
in a 56 lead High Temperature Co-Fired Ceramic (HTCC) Quad Flatpack (CQFP). It is guaranteed
operational from -55°C to +125°C. Available screened in accordance with MIL-PRF-38534, the
MUX8521 is ideal for demanding military and space applications.
ORGANIZATION AND APPLICATION
The MUX8521 consists of two 16 channel multiplexers arranged as shown in the block diagram,
addressable by bus A0~A3 including enable which connects the addressed channel to two separate outputs,
"Output" and "Current". This technique enables selecting and reading a remote resistive sensor without the
MUX resistance being part of the measurement. For grounded sensors, this is done by passing current to
the sensor by means of the "Current" pin and reading the resultant voltage (proportional to the sensor
resistance) at the "Output" pin.
SCD8521 Rev A
CH 0
•
•
•
16
16
VR
MUX 1
CH 15
OUTPUT (0-15)
EN 0-15
+VEE
-VEE
16
MUX 2
VREF
CURRENT (0-15)
GND
A0
A1
A2
A3
MUX8521: 16 KELVIN MEASUREMENT CHANNEL ANALOG MUX BLOCK DIAGRAM
SCD8521 Rev A 4/17/09
2
Aeroflex Plainview
ABSOLUTE MAXIMUM RATINGS 1/
Parameter
Range
Units
Case Operating Temperature Range
-55 to +125
°C
Storage Temperature Range
-65 to +150
°C
+16.5
-16.5
+16.5
V
V
V
< VREF +4
> GND -4
V
V
±18V
V
Supply Voltage
+VEE (Pin 18)
-VEE (Pin 46)
VREF (Pin 39)
Digital Input Overvoltage
VEN (Pin 13), VA (Pins 14, 15, 16, 17)
Analog Input Over Voltage
VS
Notes:
1/ All measurements are made with respect to ground.
NOTICE: Stresses above those listed under "Absolute Maximums Rating" may cause permanent damage to the device. These are stress rating
only; functional operation beyond the "Operation Conditions" is not recommended and extended exposure beyond the "Operation Conditions" may
affect device reliability.
RECOMMENDED OPERATING CONDITIONS 1/
Symbol
Parameter
Typical
Units
+VEE
+15V Power Supply Voltage
+15.0
V
-VEE
-15V Power Supply Voltage
-15.0
V
VREF
Reference Voltage
+5.00
V
VAL
Logic Low Level
+0.8
V
VAH
Logic High Level
+4.0
V
1/ Power Supply turn-on sequence shall be as follows: +VEE, -VEE, followed by VREF.
DC ELECTRICAL PERFORMANCE CHARACTERISTICS 1/
(TC = -55°C TO +125°C, +VEE = +15V, -VEE = -15V, VREF = +5.0V -- UNLESS OTHERWISE SPECIFIED)
Parameter
Supply Current
Address Input Current
Enable Input Current
SCD8521 Rev A 4/17/09
Symbol
Conditions
Min
Max
Units
+IEE
VEN(0-15) = VA(0-3) = 0
0.1
1
mA
-IEE
VEN(0-15) = VA(0-3) = 0
-1
-0.1
mA
+ISBY
VEN(0-15) = 4V, VA(0-3) = 0 6/
0.1
1
mA
-ISBY
VEN(0-15) = 4V, VA(0-3) = 0 6/
-1
-0.1
mA
IAL(0-3)A
VA = 0V
-2
2
µA
IAH(0-3)A
VA = 5V
-2
2
µA
IENL(0-15)
VEN(0-15) = 0V
-2
2
µA
IENH(0-15)
VEN(0-15) = 5V
-2
2
µA
3
Aeroflex Plainview
DC ELECTRICAL PERFORMANCE CHARACTERISTICS 1/ (continued)
(TC = -55°C TO +125°C, +VEE = +15V, -VEE = -15V, VREF = +5.0V -- UNLESS OTHERWISE SPECIFIED)
Parameter
Symbol
Conditions
Min
Max
Units
Positive Input Leakage
Current CH0-CH15
+ISOFFOUTPUT(ALL)
VIN = +10V, VEN = 4V, output and all unused MUX inputs
under test = -10V 2/, 3/
-100
+700
nA
Negative Input Leakage
Current CH0-CH15
-ISOFFOUTPUT(ALL)
VIN = -10V, VEN = 4V, output and all unused MUX inputs
under test = +10V 2/, 3/
-100
+700
nA
Positive Output
Leakage Current
OUTPUTS (pins 12,45)
+IDOFFOUTPUT(ALL)
VOUT = +10V, VEN = 4V, output and all unused MUX
inputs under test = -10V 3/, 4/
-100
+100
nA
Negative Output
Leakage Current
OUTPUTS (pins 12,45)
-IDOFFOUTPUT(ALL)
VOUT = -10V, VEN = 4V, output and all unused MUX inputs
under test = +10V 3/, 4/
-100
+100
nA
Input Clamped Voltage
CH0 - CH15
+VCLMP
+25°C
+125°C
-55°C
18.0
18.0
17.5
23.0
23.5
22.5
V
V
V
Input Clamped Voltage
CH0 - CH15
-VCLMP
+25°C
+125°C
-55°C
-23.0
-23.5
-22.5
-18.0
-18.0
-17.5
V
V
V
Switch ON Resistance
OUTPUTS
(pins 12,45)
VEN = 4V, all unused MUX inputs under test
are open. 3/
RDS(ON)(0-15)A
VIN = +15V, VEN = 0.8V, IOUT = -1mA 2/, 3/, 5/
500
3000
Ω
RDS(ON)(0-15)B
VIN = +5V, VEN = 0.8V, IOUT = -1mA 2/, 3/, 5/
500
3000
Ω
RDS(ON)(0-15)C
VIN = -5V, VEN = 0.8V, IOUT = +1mA 2/, 3/, 5/
500
3000
Ω
Notes:
1/ Measure inputs sequentially. Ground all unused inputs of the device under test. VA is the applied input voltage to the address lines A(0-3).
2/ VIN is the applied input voltage to the input channels CH0-CH15.
3/ VEN is the applied input voltage to the enable line EN (0-15).
4/ VOUT is the applied input voltage to the output lines OUTPUT (0-15), CURRENT (0-15)
5/ Negative current is the current flowing out of each of the MUX pins. Positive current is the current flowing into each MUX pin.
6/ Not tested, guaranteed to the specified limits.
SWITCHING CHARACTERISTICS
(TC = -55°C TO +125°C, +VEE = +15V, -VEE = -15V, VREF = +5.0V -- UNLESS OTHERWISE SPECIFIED)
Parameter
Switching Test MUX
Symbol
Min
Max
Units
tAHL
RL = 10KΩ, CL = 50pF
10
1500
ns
tALH
RL = 10KΩ, CL = 50pF
Tc = +25°C, +125°C
Tc = -55°C
10
10
2000
5000
ns
ns
10
1500
ns
10
1000
ns
tONEN
tOFFEN
SCD8521 Rev A 4/17/09
Conditions
RL = 1KΩ, CL = 50pF
4
Aeroflex Plainview
TRUTH TABLE (CH0 – CH15)
A3
A2
A1
A0
EN (0-15)
"ON" CHANNEL 1/
X
X
X
X
H
NONE
L
L
L
L
L
CH0
L
L
L
H
L
CH1
L
L
H
L
L
CH2
L
L
H
H
L
CH3
L
H
L
L
L
CH4
L
H
L
H
L
CH5
L
H
H
L
L
CH6
L
H
H
H
L
CH7
H
L
L
L
L
CH8
H
L
L
H
L
CH9
H
L
H
L
L
CH10
H
L
H
H
L
CH11
H
H
L
L
L
CH12
H
H
L
H
L
CH13
H
H
H
L
L
CH14
H
H
H
H
L
CH15
1/ Between CH0-15 and OUTPUT (0-15), CURRENT (0-15)
SCD8521 Rev A 4/17/09
5
Aeroflex Plainview
Address Lines
(A0 - A3)
4.0V
50%
0.8V
11.6V MIN
50%
MUX Output
0V
t AHL
Definition of t AHL
4.0V
Address Lines
(A0 - A3)
50%
0.8V
11.6V MIN
MUX Output
50%
0V
t ALH
Definition of t ALH
4.0V
EN Lines
50%
0.8V
~3V to 10.0V
MUX Output
50%
0V
tONEN
tOFFEN
Definition of tONEN and tOFFEN
NOTE: f = 10KHz, Duty cycle = 50%.
MUX8521 SWITCHING DIAGRAMS
SCD8521 Rev A 4/17/09
6
Aeroflex Plainview
PIN NUMBERS & FUNCTIONS
MUX8521 – 56 Leads Ceramic QUAD Flat Pack
Pin #
Function
Pin #
Function
1
CH0
29
NC
2
CH1
30
NC
3
CH2
31
NC
4
CH3
32
NC
5
CH4
33
NC
6
CH5
34
NC
7
GND
35
GND
8
GND
36
GND
9
CH6
37
NC
10
CH7
38
NC
11
CASE GND
39
VREF
12
OUTPUT (0-15)
40
NC
13
EN 0-15
41
NC
14
A0
42
NC
15
A1
43
NC
16
A2
44
NC
17
A3
45
CURRENT (0-15)
18
+VEE
46
-VEE
19
CH15
47
NC
20
CH14
48
NC
21
GND
49
GND
22
GND
50
GND
23
CH13
51
NC
24
CH12
52
NC
25
CH11
53
NC
26
CH10
54
NC
27
CH9
55
NC
28
CH8
56
NC
Notes:
1. It is recommended that all "NC" or "no connect pin", be grounded. This eliminates or minimizes any ESD or static buildup.
2. Package lid is internally connected to circuit ground (Pins 7, 8, 11, 21, 22, 35, 36, 49, 50).
SCD8521 Rev A 4/17/09
7
Aeroflex Plainview
ORDERING INFORMATION
Model
DSCC SMD #
Screening
MUX8521-S
-
Military Temperature, -55°C to +125°C
Screened in accordance with MIL-PRF-38534, Class K
MUX8521-7
-
Commercial Flow, +25°C testing only
5962-0922902KXC
(Pending)
In accordance with DSCC SMD
MUX8521-201-1S
PACKAGE OUTLINE
Package
QUAD Flat
Pack
0.650 ±.005
(13 Spaces at .050)
Tol Non-Cum
4 Sides
Pin 1
Pin 7
.200
MAX
Pin 50
Pin 49
Pin 8
.0165
±.003
0.800 SQ
±.010
Pin 21
(.650)
Pin 36
Pin 35
Pin 22
Note: Outside ceramic tie bars
not shown for clarity. Contact
factory for details.
.006
±.002
EXPORT CONTROL:
EXPORT WARNING:
This product is controlled for export under the International Traffic in
Arms Regulations (ITAR). A license from the U.S. Department of
State is required prior to the export of this product from the United
States.
Aeroflex’s military and space products are controlled for export under
the International Traffic in Arms Regulations (ITAR) and may not be
sold or proposed or offered for sale to certain countries. (See ITAR
126.1 for complete information.)
PLAINVIEW, NEW YORK
Toll Free: 800-THE-1553
Fax: 516-694-6715
INTERNATIONAL
Tel: 805-778-9229
Fax: 805-778-1980
NORTHEAST
Tel: 603-888-3975
Fax: 603-888-4585
SE AND MID-ATLANTIC
Tel: 321-951-4164
Fax: 321-951-4254
WEST COAST
Tel: 949-362-2260
Fax: 949-362-2266
CENTRAL
Tel: 719-594-8017
Fax: 719-594-8468
www.aeroflex.com
[email protected]
Aeroflex Microelectronic Solutions reserves the right to
change at any time without notice the specifications, design,
function, or form of its products described herein. All
parameters must be validated for each customer's application
by engineering. No liability is assumed as a result of use of
this product. No patent licenses are implied.
SCD8521 Rev A 4/17/09
V
Our passion for performance is defined by three
attributes represented by these three icons:
solution-minded, performance-driven and customer-focused
8
REVISIONS
LTR
DATE (YR-MO-DA)
APPROVED
A
Add device type 02. Add appendix A for device type 02 only. Make editorial
changes throughout.
DESCRIPTION
97-04-09
R. MONNIN
B
Make change to 1.4, 30.2.1, IS(OFF) overvoltage and ID(OFF) overvoltage
tests. - ro
97-09-12
R. MONNIN
C
Make change to boilerplate and add device class T for device type 02. - ro
98-12-02
R. MONNIN
D
Add level P to table I. Make change to 1.5 and glassivation as specified under
APPENDIX A. - ro
99-04-22
R. MONNIN
E
Make change to enable delay waveform as specified on figure 6 - ro
00-04-14
R. MONNIN
F
Make changes to supply voltage and VREF to GND limits as specified
under 1.3. Make clarification to paragraphs 4.4.4.2 and 4.4.4.3. - ro
04-06-25
R. MONNIN
06-02-24
R. MONNIN
Under 1.5, move footnote 3/ to the latch up parameter. Make correction to the
G
RL value under the tON(A), tOFF(A) test as specified in table I. - ro
REV
SHEET
REV
G
G
G
G
G
G
G
G
G
G
G
G
SHEET
15
16
17
18
19
20
21
22
23
24
25
26
G
G
G
G
G
G
G
G
G
1
2
3
4
5
6
7
8
9
REV STATUS
REV
OF SHEETS
SHEET
PMIC N/A
PREPARED BY
RAJESH PITHADIA
STANDARD
MICROCIRCUIT
DRAWING
THIS DRAWING IS AVAILABLE
FOR USE BY ALL
DEPARTMENTS
AND AGENCIES OF THE
DEPARTMENT OF DEFENSE
AMSC N/A
DRAWING APPROVAL DATE
95-08-23
REVISION LEVEL
G
G
G
G
10
11
12
13
14
MICROCIRCUIT, DIGITAL-LINEAR,
RADIATION HARDENED, SINGLE 16CHANNEL ANALOG MUX / DEMUX WITH
OVERVOLTAGE PROTECTION, MONOLITHIC
SILICON
SIZE
CAGE CODE
A
67268
SHEET
DSCC FORM 2233
APR 97
G
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
http://www.dscc.dla.mil
CHECKED BY
RAJESH PITHADIA
APPROVED BY
MICHAEL FRYE
G
1 OF
5962-95630
26
5962-E254-06
1. SCOPE
1.1 Scope. This drawing documents three product assurance class levels consisting of high reliability (device classes Q and
M), space application (device class V) and for appropriate satellite and similar applications (device class T). A choice of case
outlines and lead finishes are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of
Radiation Hardness Assurance (RHA) levels are reflected in the PIN. For device class T, the user is encouraged to review the
manufacturer’s Quality Management (QM) plan as part of their evaluation of these parts and their acceptability in the intended
application.
1.2 PIN. The PIN is as shown in the following example:
5962
⏐
⏐
⏐
Federal
stock class
designator
\
R
⏐
⏐
⏐
RHA
designator
(see 1.2.1)
95630
01
⏐
⏐
⏐
Device
type
(see 1.2.2)
V
⏐
⏐
⏐
Device
class
designator
(see 1.2.3)
/
X
⏐
⏐
⏐
Case
outline
(see 1.2.4)
C
⏐
⏐
⏐
Lead
finish
(see 1.2.5)
\/
Drawing number
1.2.1 RHA designator. Device classes Q, T and V RHA marked devices meet the MIL-PRF-38535 specified RHA levels and
are marked with the appropriate RHA designator. Device class M RHA marked devices meet the MIL-PRF-38535, appendix A
specified RHA levels and are marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device.
1.2.2 Device type(s). The device type(s) identify the circuit function as follows:
Device type
Generic number
Circuit function
01
HS-1840RH
Radiation hardened DI single 16-channel
analog MUX / DEMUX with high impedance
analog input overvoltage protection
02
HS-1840ARH
Radiation hardened DI single 16-channel
analog MUX / DEMUX with high impedance
analog input overvoltage protection
1.2.3 Device class designator. The device class designator is a single letter identifying the product assurance level as
follows:
Device class
Device requirements documentation
M
Vendor self-certification to the requirements for MIL-STD-883 compliant,
non-JAN class level B microcircuits in accordance with MIL-PRF-38535,
appendix A
Q, V
Certification and qualification to MIL-PRF-38535
T
Certification and qualification to MIL-PRF-38535 with performance as specified
in the device manufacturers approved quality management plan.
1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows:
Outline letter
X
Y
Descriptive designator
CDIP2-T28
CDFP3-F28
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
Terminals
Package style
28
28
Dual-in-line
Flat pack
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
2
1.2.5 Lead finish. The lead finish is as specified in MIL-PRF-38535 for device classes Q, T and V or MIL-PRF-38535,
appendix A for device class M.
1.3 Absolute maximum ratings. 1/
Supply voltage between V+ and V- :
Device type 01 ...........................................................................
Device type 02 ...........................................................................
Supply voltage between V+ and GND :
Device type 01 ...........................................................................
Device type 02 ...........................................................................
Supply voltage between V- and GND :
Device type 01 ...........................................................................
Device type 02 ...........................................................................
VREF to GND :
Device type 01 ...........................................................................
Device type 02 ...........................................................................
Digital input overvoltage range ......................................................
Analog input overvoltage range (power on/off):
Device type 01 ...........................................................................
+40 V
+33 V
+20 V
+16.5 V
-20 V
-16.5 V
+20 V
+16.5 V
((GND) - 4 V) ≤ VA ≤ ((VREF) + 4 V)
-25 V ≤ VS ≤ +25 V
Device type 02 ........................................................................... -35 V ≤ VS ≤ +35 V
Storage temperature range ............................................................ -65°C to +150°C
Maximum package power dissipation (PD): 2/
Case X ..................................................................................... 1600 mW
Case Y ..................................................................................... 1400 mW
Lead temperature (soldering, 10 seconds) .................................... +275°C
Thermal resistance, junction-to-case (θJC) .................................... See MIL-STD-1835
Thermal resistance, junction-to-ambient (θJA):
Case X ..................................................................................... 83.1°C/W
Case Y ..................................................................................... 49.1°C/W
1.4 Recommended operating conditions.
Positive supply voltage (V+) ........................................................... +15 V
Negative supply voltage (V-)........................................................... -15 V
VREF .............................................................................................. 5 V dc
VAH ................................................................................................ 4.0 V dc
VAL ................................................................................................ 0.8 V dc
VEN ................................................................................................ 0.8 V dc
Ambient operating temperature range (TA) ................................... -55°C to +125°C
____
1/ Stresses above the absolute maximum rating may cause permanent damage to the device. Extended operation at the
maximum levels may degrade performance and affect reliability.
2/ The derating factor for case X shall be 20.4 mW/°C, above TA = +95°C, and for case Y shall be 18.5 mW/°C above
TA = +95°C.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
3
1.5 Radiation features.
SEP effective let no upsets:
2
Device type 01 ............................................................................ 110 MeV/cm /mg
Device type 02 ............................................................................
Maximum total dose available: (dose rate = 50 – 300 rad(Si)/s)
Device classes M, Q, and V:
Device type 01 ..........................................................................
Device type 02 ..........................................................................
Device class T:
Device type 02 ..........................................................................
Dose rate upset:
Device type 01 ............................................................................
Device type 02 ............................................................................
Latch up .........................................................................................
2
120 MeV/cm /mg
200 Krads (Si)
300 Krads (Si)
100 Krads (Si)
8
>1 x 10 rad(Si)/s
Not tested
None 3/
2. APPLICABLE DOCUMENTS
2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part
of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the
solicitation or contract.
DEPARTMENT OF DEFENSE SPECIFICATION
MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for.
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-883 MIL-STD-1835 -
Test Method Standard Microcircuits.
Interface Standard Electronic Component Case Outlines.
DEPARTMENT OF DEFENSE HANDBOOKS
MIL-HDBK-103 MIL-HDBK-780 -
List of Standard Microcircuit Drawings.
Standard Microcircuit Drawings.
(Copies of these documents are available online at http://assist.daps.dla.mil/quicksearch/ or http://assist.daps.dla.mil or
from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of
this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a
specific exemption has been obtained.
_____
3/ Guaranteed by process design, but not tested, unless specified in table I herein.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
4
3. REQUIREMENTS
3.1 Item requirements. The individual item requirements for device classes Q, T and V shall be in accordance with
MIL-PRF-38535 and as specified herein or as modified in the device manufacturer's Quality Management (QM) plan. The
modification in the QM plan shall not affect the form, fit, or function as described herein. The individual item requirements for
device class M shall be in accordance with MIL-PRF-38535, appendix A for non-JAN class level devices and as specified herein.
3.1.1 Microcircuit die. For the requirements for microcircuit die, see appendix A to this document.
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in
MIL-PRF-38535 and herein for device classes Q, T and V or MIL-PRF-38535, appendix A and herein for device class M.
3.2.1 Case outlines. The case outlines shall be in accordance with 1.2.4 herein.
3.2.2 Terminal connections. The terminal connections shall be as specified on figure 1.
3.2.3 Truth table. The truth table shall be as specified on figure 2.
3.2.4 Logic diagrams. The logic diagrams shall be as specified on figure 3.
3.2.5 Radiation exposure circuit. The radiation exposure circuit shall be as specified on figure 4.
3.3 Electrical performance characteristics and postirradiation parameter limits. Unless otherwise specified herein, the
electrical performance characteristics and postirradiation parameter limits are as specified in table I and shall apply over the full
ambient operating temperature range.
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table IIA. The electrical
tests for each subgroup are defined in table I.
3.5 Marking. The part shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturer's PIN may also be
marked. For packages where marking of the entire SMD PIN number is not feasible due to space limitations, the manufacturer
has the option of not marking the "5962-" on the device. For RHA product using this option, the RHA designator shall still be
marked. Marking for device classes Q, T and V shall be in accordance with MIL-PRF-38535. Marking for device class M shall
be in accordance with MIL-PRF-38535, appendix A.
3.5.1 Certification/compliance mark. The certification mark for device classes Q, T and V shall be a "QML" or "Q" as required
in MIL-PRF-38535. The compliance mark for device class M shall be a "C" as required in MIL-PRF-38535, appendix A.
3.6 Certificate of compliance. For device classes Q, T and V, a certificate of compliance shall be required from a QML-38535
listed manufacturer in order to supply to the requirements of this drawing (see 6.6.1 herein). For device class M, a certificate of
compliance shall be required from a manufacturer in order to be listed as an approved source of supply in MIL-HDBK-103 (see
6.6.2 herein). The certificate of compliance submitted to DSCC-VA prior to listing as an approved source of supply for this
drawing shall affirm that the manufacturer's product meets, for device classes Q, T and V, the requirements of MIL-PRF-38535
and herein or for device class M, the requirements of MIL-PRF-38535, appendix A and herein.
3.7 Certificate of conformance. A certificate of conformance as required for device classes Q, T and V in MIL-PRF-38535 or
for device class M in MIL-PRF-38535, appendix A shall be provided with each lot of microcircuits delivered to this drawing.
3.8 Notification of change for device class M. For device class M, notification to DSCC-VA of change of product (see 6.2
herein) involving devices acquired to this drawing is required for any change that affects this drawing.
3.9 Verification and review for device class M. For device class M, DSCC, DSCC's agent, and the acquiring activity retain the
option to review the manufacturer's facility and applicable required documentation. Offshore documentation shall be made
available onshore at the option of the reviewer.
3.10 Microcircuit group assignment for device class M. Device class M devices covered by this drawing shall be in
microcircuit group number 82 (see MIL-PRF-38535, appendix A).
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
5
TABLE I. Electrical performance characteristics.
Test
Input leakage current, 2/
address or enable pins
Symbol
IAH
Conditions 1/
-55°C ≤ TA ≤ +125°C
unless otherwise specified
Group A
subgroups
Measure inputs
sequentially, ground
all used pins.
IAL
M, D, P, L, R, F
Leakage current into the
source terminal of an off
switch
IS(OFF)
M, D, P, L, R, F 4/
VS = +10 V, all unused
inputs and output
equal -10 V, see figure 5
M, D, P, L, R, F 4/
Leakage current into the
source terminal of an off
switch with power off
IS(OFF)
power
off
M, D, P, L, R, F
Leakage current into the
source terminal of an off
switch with overvoltage
applied
IS(OFF)
overvoltage
-1.0
1.0
1 3/
-1.0
1.0
1,2,3
-1.0
1.0
1 3/
-1.0
1.0
-10
+10
2,3
-100
+100
1 3/
-100
+100
1
-10
+10
2,3
-100
+100
1 3/
-100
+100
-50
+50
2,3
-100
+100
1 3/
-100
+100
-1
+1
1
VS = +25 V, VA = 0 V,
VEN = 0 V, V- = 0 V,
V+ = 0 V, VREF = 0 V,
all unused inputs tied to
GND, see figure 5
Unit
Max
1
VS = -10 V, all unused
inputs and output
equal +10 V, see figure 5
Limits
Min
1,2,3
M, D, P, L, R, F
Device
type
01,02
01,02
01,02
VD = 0 V, all unused inputs
tied to GND, see figure 5
1,2,3
M, D, P, L, R, F 4/
1 3/
-1.5
+1.5
VD = 0 V, all unused inputs
tied to GND, see figure 5
1,2,3
-1
+1
M, D, P, L, R, F 4/
1 3/
-1.5
+1.5
5/
6/
01,02
µA
µA
nA
nA
nA
µA
µA
See footnotes at end table.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
6
TABLE I. Electrical performance characteristics - Continued.
Test
Leakage current into the
drain terminal of an off
switch with overvoltage
applied
Symbol
ID(OFF)
overvoltage
Conditions 1/
-55°C ≤ TA ≤ +125°C
unless otherwise specified
ID(OFF)
ID(ON)
-1
+1
+1
VD = 0 V, all unused inputs
tied to GND, see figure 5
1,2,3
-1
+1
M, D, P, L, R, F 4/
1 3/
-1
+1
-10
+10
2,3
-100
+100
1 3/
-100
+100
-10
+10
2,3
-100
+100
1 3/
-100
+100
-10
+10
2,3
-100
+100
1 3/
-100
+100
1
-10
+10
2,3
-100
+100
1 3/
-100
+100
1
1
VD = +10 V, all unused
inputs = -10 V,
see figure 5
1
VS = +10 V, VD = +10 V,
VEN = 0.8 V, all unused
input = -10 V, see figure 5
M, D, P, L, R, F 7/
VS = -10 V, VD = -10 V,
VEN = 0.8 V, all unused
input = +10 V, see figure 5
M, D, P, L, R, F 7/
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
Max
-1
M, D, P, L, R, F 4/
Leakage current from an on
driver into the switch (drain
and source)
Min
1 3/
M, D, P, L, R, F 4/
Leakage current into the
drain terminal of an off
switch
Unit
M, D, P, L, R, F 4/
VD = -10 V, all unused
inputs = +10 V,
see figure 5
01,02
Limits
1,2,3
6/
ID(OFF)
Device
type
VD = 0 V, all unused inputs
tied to GND, see figure 5
5/
Leakage current into the
drain terminal of an off
switch
Group A
subgroups
01,02
01,02
01,02
µA
µA
nA
nA
nA
nA
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
7
TABLE I. Electrical performance characteristics - Continued.
Test
Positive supply current
Symbol
I+
Conditions 1/
-55°C ≤ TA ≤ +125°C
unless otherwise specified
Group A
subgroups
M, D, P, L, R, F 7/
Negative power supply
I-
VA = 0 V, VEN = 0.8 V
M, D, P, L, R, F 7/
Positive standby supply
current
+ISBY
M, D, P, L, R, F 4/
Negative standby power
supply
-ISBY
VA = 0 V, VEN = 4.0 V
M, D, P, L, R, F 4/
Switch on resistance
RDS(ON)
0.05
0.5
1 3/
0.05
0.5
1,2,3
0.05
0.5
1 3/
0.05
0.5
0.05
0.5
1 3/
0.05
0.5
1,2,3
0.05
0.5
1 3/
0.05
0.5
01
---
1.0
02
0.5
3.0
01
---
1.0
02
0.5
3.0
01
---
4.0
02
0.5
3.0
01
---
4.0
02
0.5
3.0
01
---
2.5
02
0.5
3.0
01
---
2.5
02
0.5
3.0
1,2,3
VS = +15 V, ID = -1 mA,
VEN = 0.8 V, see figure 5
1 3/
M, D, P, L, R, F 7/
1,2,3
VS = -5 V, ID = +1 mA,
VEN = 0.8 V, see figure 5
1 3/
M, D, P, L, R, F 7/
1,2,3
VS = +5 V, ID = -1 mA,
VEN = 0.8 V, see figure 5
1 3/
M, D, P, L, R, F 7/
Unit
Max
1,2,3
VA = 0 V, VEN = 4.0 V
Limits
Min
1,2,3
VA = 0 V, VEN = 0.8 V
Device
type
01,02
01,02
mA
mA
mA
mA
kΩ
See footnotes at end of table.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
8
TABLE I. Electrical performance characteristics - Continued.
Test
Symbol
Conditions 1/
-55°C ≤ TA ≤ +125°C
unless otherwise specified
Group A
subgroups
Device
type
Limits
Min
Unit
Max
Capacitance:
digital input
CA
V+ = V- = 0 V,
f = 1 MHz, TA = +25°C,
see 4.4.1c
4
01,02
7
pF
Capacitance:
channel input
CS(OFF)
V+ = V- = 0 V,
f = 1 MHz, TA = +25°C,
see 4.4.1c
4
01,02
5
pF
Capacitance:
channel output
CD(OFF)
V+ = V- = 0 V,
f = 1 MHz, TA = +25°C,
see 4.4.1c
4
01,02
50
pF
Off isolation input or
output
VISO
VEN = 4.0 V, f = 200 kHz,
CL = 7 pF, RL = 1 kΩ,
VS = 3 VRMS,
TA = +25°C, see 4.4.1c
4
01,02
7,8A,8B
01,02
9
01,02
Functional test
Break-before-make time
delay
See 4.4.1d
tD
CL = 50 pF, RL = 1 kΩ,
see figure 6
M, D, P, L, R, F
4/ 7/ 8/
Propagation delay time
address inputs to I/O
channels
tON(A),
tOFF(A)
25
ns
5
9 3/
5
10,11
M, D, P, L, R, F
4/ 7/ 8/
dB
10,11
9
CL = 50 pF, RL = 10 kΩ,
see figure 6
-45
9 3/
01
0.6
02
1.25
01
1.0
02
1.5
01
3.0
02
1.5
µs
See footnotes at end of table.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
9
TABLE I. Electrical performance characteristics - Continued.
Test
Symbol
Conditions 1/
-55°C ≤ TA ≤ +125°C
unless otherwise specified
Group A
subgroups
Device
type
Limits
Min
Propagation delay time
enable to I/O channels
tON(EN),
tOFF(EN)
9
CL = 50 pF, RL = 1 kΩ,
see figure 6
10,11
M, D, P, L, R, F
4/ 7/ 8/
9 3/
Unit
Max
01
0.6
02
1.25
01
1.0
02
1.5
01
3.0
02
1.5
µs
1/ VAH (logic level high) = 4.0 V dc, VAL (logic level low) = 0.8 V dc, V+ = +15 V dc, V- = -15 V dc, VEN = 4.0 V unless
otherwise specified, and VREF = 5.0 V dc.
2/ Input current of one node.
3/ Devices supplied to this drawing will meet all levels M, D, P, L, R, for device type 01 (device classes M, Q, and V) and
levels M, D, P, L, R, F for device type 02 (device classes M, Q, or V) and levels M, D, P, L, R, for device type 02
(device class T). However, device type 01(device classes M, Q, and V) is only tested at the "R" level and device
type 02 (device classes M, Q, and V) is only tested at the "F" level, and device type 02 (class T) is only tested at the
“R” level. (see paragraph 1.5 herein). Pre and Post irradiation values are identical unless otherwise specified in Table I.
When performing post irradiation electrical measurements for any RHA level, TA = +25°C.
4/ VEN = 4.5 V
5/ For device type 01, VS = +25 V. For device type 02, VS = +35 V.
6/ For device type 01, VS = -25 V. For device type 02, VS = -35 V.
7/ VEN = 0.5 V
8/ VAH = 4.5 V and VAL = 0.5 V
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
10
Device types
01 and 02
Case outlines
X and Y
Terminal
number
Terminal symbol
1
V+
2
NC
3
NC
4
IN 16
5
IN 15
6
IN 14
7
IN 13
8
IN 12
9
IN 11
10
IN 10
11
IN 9
12
GND
13
VREF
14
A3
15
A2
16
A1
17
A0
18
EN
19
IN 1
20
IN 2
21
IN 3
22
IN 4
23
IN 5
24
IN 6
25
IN 7
26
IN 8
27
V-
28
OUT
NC = No connection
FIGURE 1. Terminal connections.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
11
Truth table
A3
A2
A1
A0
EN
On channel
X
X
X
X
H
None
L
L
L
L
L
1
L
L
L
H
L
2
L
L
H
L
L
3
L
L
H
H
L
4
L
H
L
L
L
5
L
H
L
H
L
6
L
H
H
L
L
7
L
H
H
H
L
8
H
L
L
L
L
9
H
L
L
H
L
10
H
L
H
L
L
11
H
L
H
H
L
12
H
H
L
L
L
13
H
H
L
H
L
14
H
H
H
L
L
15
H
H
H
H
L
16
FIGURE 2. Truth table.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
12
FIGURE 3. Logic diagram.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
13
FIGURE 4. Radiation exposure circuit.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
14
FIGURE 5. Test circuits for dc levels.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
15
FIGURE 6. Test circuits and waveforms for ac levels.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
16
4. VERIFICATION
4.1 Sampling and inspection. For device classes Q and V, sampling and inspection procedures shall be in accordance with
MIL-PRF-38535 or as modified in the device manufacturer's (QM) plan, including screening (4.2), qualification (4.3), and
conformance inspection (4.4). The modification in the QM plan shall not affect the form, fit, or function as described herein.
For device class T, sampling and inspection procedures shall be in accordance with MIL-PRF-38535 or as modified in the device
manufacturer's (QM) plan, including screening, qualification, and conformance inspection. The performance envelope and
reliability information shall be as specified in the manufacturer’s QM plan.
For device class M, sampling and inspection procedures shall be in accordance with MIL-PRF-38535, appendix A.
4.2 Screening. For device classes Q and V, screening shall be in accordance with MIL-PRF-38535, and shall be conducted
on all devices prior to qualification and technology conformance inspection. For device class M, screening shall be in
accordance with method 5004 of MIL-STD-883, and shall be conducted on all devices prior to quality conformance inspection.
For device class T, screening shall be in accordance with the device manufacturer’s Quality Management (QM) plan, and shall
be conducted on all devices prior to qualification and technology conformance inspection.
4.2.1 Additional criteria for device class M.
a.
Burn-in test, method 1015 of MIL-STD-883.
(1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision
level control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in
method 1015.
(2) TA = +125°C, minimum.
b.
Interim and final electrical test parameters shall be as specified in table IIA herein.
4.2.2 Additional criteria for device classes Q, T and V.
a.
The burn-in test duration, test condition and test temperature, or approved alternatives shall be as specified in the
device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall be maintained under
document revision level control of the device manufacturer's Technology Review Board (TRB) in accordance with
MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in
method 1015 of MIL-STD-883.
b.
For devices classes Q, T, and V interim and final electrical test parameters shall be as specified in table IIA herein.
c.
Additional screening for device class V beyond the requirements of device class Q shall be as specified in
MIL-PRF-38535, appendix B or as modified in the device manufacturer’s Quality Management (QM) plan.
4.3 Qualification inspection for device classes Q, T and V. Qualification inspection for device classes Q and V shall be in
accordance with MIL-PRF-38535. Qualification inspection for device class T shall be in accordance with the device
manufacturer’s Quality Management (QM) plan. Inspections to be performed shall be those specified in MIL-PRF-38535 and
herein for groups A, B, C, D, and E inspections (see 4.4.1 through 4.4.4).
4.4 Conformance inspection. Technology conformance inspection for classes Q and V shall be in accordance with
MIL-PRF-38535 as specified in the QM plan including groups A, B, C, D, and E inspections and as specified herein. Quality
conformance inspection for device class M shall be in accordance with MIL-PRF-38535, appendix A and as specified herein.
Inspections to be performed for device class M shall be those specified in method 5005 of MIL-STD-883 and herein for groups
A, B, C, D, and E inspections (see 4.4.1 through 4.4.4). Technology conformance inspection for class T shall be in accordance
with the device manufacturer’s Quality Management (QM) plan.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
17
TABLE IIA. Electrical test requirements.
Test requirements
Subgroups
(in accordance with
MIL-PRF-38535, table III)
Subgroups
(in accordance with
MIL-STD-883,
method 5005, table I)
Device
class M
Device
class Q
Device
class V
Interim electrical
parameters (see 4.2)
1,7,9
1,7,9
1,7,9
Final electrical
parameters (see 4.2)
1,2,3,7,8A, 1/
8B,9,10,11
1,2,3,7,8A, 1/
8B,9,10,11
1,2,3, 1/ 2/
7,8A,8B,9,
10,11
Group A test
requirements (see 4.4)
1,2,3,4,7,8A,8B,9,
10,11
1,2,3,4,7,8A,
8B,9,10,11
1,2,3,4,7, 2/
8A,8B,9,10,
11
Group C end-point electrical
parameters (see 4.4)
1,2,3,7,8A,8B,
9,10,11
1,2,3,7,8A,8B,
9,10,11
1,2,3,7,8A,
8B,9,10,11
Group D end-point electrical
parameters (see 4.4)
1,7,9
1,7,9
1,7,9
Group E end-point electrical
parameters (see 4.4)
1,7,9
1,7,9
1,7,9
Device
class T
As specified
in QM plan
1/PDA applies to subgroup 1. For class V, 1, 7, and ∆.
2/Delta limits (see table IIB) shall be required and the delta values shall be computed with reference
to the zero hour electrical parameters (see table I).
4.4.1 Group A inspection.
a.
Tests shall be as specified in table IIA herein.
b.
Subgroups 5 and 6 in table I, method 5005 of MIL-STD-883 shall be omitted.
c.
Subgroup 4 (CA, CS, CD, and VISO measurments) should be measured for initial qualification and after any process
or design changes which may affect input or output capacitance.
d.
For device class M, subgroups 7 and 8 tests shall be sufficient to verify the truth table. For device classes Q and V,
subgroups 7 and 8 shall include verifying the functionality of the device.
4.4.2 Group C inspection. The group C inspection end-point electrical parameters shall be as specified in table IIA herein.
4.4.2.1 Additional criteria for device class M. Steady-state life test conditions, method 1005 of MIL-STD-883:
a.
Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify the
inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of
MIL-STD-883.
b.
TA = +125°C, minimum.
c.
Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
18
TABLE IIB. Burn-in delta parameters (+25°C) and group C delta parameters.
Parameters
Input leakage current,
address, or enable pins
Leakage current into the
source terminal of an "Off"
switch
Symbol
Conditions
Delta limits
IAH
Measure inputs sequentially,
ground all unbiased pins
±100 nA
+IS(OFF)
VS = +10 V, all unused and
±20 nA
output = -10 V, VEN = 4.0 V
-IS(OFF)
±20 nA
VS = -10 V, all unused inputs
and outputs = +10 V, VEN =
4.0 V
Leakage current into the
drain terminal of an "Off"
switch
+ID(OFF)
±20 nA
VD = +10 V, all unused
inputs = -10 V, VEN = 4.0 V
-ID(OFF)
±20 nA
VD = -10 V, all unused
inputs = +10 V, VEN = 4.0 V
Leakage current from an
"On" driver into the switch
(drain and source)
+ID(ON)
±20 nA
VS = +10 V, all unused
inputs = -10 V, VEN = 0.8 V,
VD = +10 V
-ID(ON)
±20 nA
VS = -10 V, all unused
inputs = +10 V, VD = -10 V,
VEN = 0.8 V
Switch on resistance
R(ON)
±150 Ω
VS = +15 V, ID = -1 mA,
VEN = 0.8 V
±250 Ω
VS = -5 V, ID = +1 mA,
VEN = 0.8 V
Positive supply current
I+
VEN = 0.8 V
±50 µA
Negative supply current
I-
VEN = 0.8 V
±50 µA
Positive standby supply
current
+ISBY
VEN = 4.0 V
±50 µA
Negative standby supply
current
-ISBY
VEN = 4.0 V
±50 µA
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
19
4.4.2.2 Additional criteria for device classes Q, T and V. The steady-state life test duration, test condition and test
temperature, or approved alternatives shall be as specified in the device manufacturer's QM plan in accordance with MIL-PRF38535. The test circuit shall be maintained under document revision level control by the device manufacturer's TRB in
accordance with MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit
shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method
1005 of MIL-STD-883.
4.4.3 Group D inspection. The group D inspection end-point electrical parameters shall be as specified in table IIA herein.
4.4.4 Group E inspection. Group E inspection is required only for parts intended to be marked as radiation hardness assured
(see 3.5 herein). RHA levels for device classes M, Q and V shall be as specified in MIL-PRF-38535. End-point electrical
parameters shall be as specified in table IIA herein. For device class T, the RHA requirements shall be in accordance with the
Class T radiation requirements of MIL-PRF-38535. The end-point electrical parameters for class T devices shall be as specified
in Table I, Group A subgroups, or as modified in the QM plan.
4.4.4.1 Total dose irradiation testing. Total dose irradiation testing shall be performed in accordance with MIL-STD-883
method 1019 condition A and as specified herein. For device class T, the total dose requirements shall be in accordance with the
class T radiation requirements of MIL-PRF-38535 ( see 1.5 herein ).
4.4.4.1.1 Accelerated aging test. Accelerated aging tests shall be performed on all devices requiring a RHA level greater than
5k rads(Si). The post-anneal end-point electrical parameter limits shall be as specified in table I herein and shall be the preirradiation end-point electrical parameter limit at 25°C ±5°C. Testing shall be performed at initial qualification and after any
design or process changes which may affect the RHA response of the device.
4.4.4.2 Dose rate induced latchup testing. When specified in the purchase order or contract, dose rate induced latchup
testing shall be performed in accordance with test method 1020 of MIL-STD-883 and as specified herein (see 1.5 herein). Tests
shall be performed on devices, SEC, or approved test structures at technology qualification and after any design or process
changes which may effect the RHA capability of the process.
4.4.4.3 Dose rate upset testing. When specified in the purchase order or contract, dose rate upset testing shall be performed
in accordance with test method 1021 of MIL-STD-883 and herein (see 1.5 herein).
a. Transient dose rate upset testing shall be performed at initial qualification and after any design or process changes which
may affect the RHA performance of the devices. Test 10 devices with 0 defects unless otherwise specified.
b. Transient dose rate upset testing for class Q, T, and V devices shall be performed as specified by a TRB approved
radiation hardness assurance plan and MIL-PRF-38535.
4.4.4.4 Single event phenomena (SEP). When specified in the purchase order or contract, SEP testing shall be required on
class T and V devices (see 1.5 herein). SEP testing shall be performed on a technology process on the Standard Evaluation
Circuit (SEC) or alternate SEP test vehicle as approved by the qualifying activity at initial qualification and after any design or
process changes which may affect the upset or latchup characteristics. The recommended test conditions for SEP are as
follows:
a. The ion beam angle of incidence shall be between normal to the die surface and 60° to the normal, inclusive
(i.e. 0° ≤ angle ≤ 60°). No shadowing of the ion beam due to fixturing or package related effects is allowed.
6
2
b. The fluence shall be ≥ 100 errors or ≥ 10 ions/cm .
2
5
2
c. The flux shall be between 10 and 10 ions/cm /s. The cross-section shall be verified to be flux independent by
measuring the cross-section at two flux rates which differ by at least an order of magnitude.
d. The particle range shall be ≥ 20 micron in silicon.
e. The test temperature shall be +25°C and the maximum rated operating temperature ±10°C.
f. Bias conditions shall be defined by the manufacturer for the latchup measurements.
g. Test four devices with zero failures.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
20
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535 for device classes
Q, T and V or MIL-PRF-38535, appendix A for device class M.
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications
(original equipment), design applications, and logistics purposes.
6.1.1 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor
prepared specification or drawing.
6.1.2 Substitutability. Device class Q devices will replace device class M devices.
6.2 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for
the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal.
6.3 Record of users. Military and industrial users should inform Defense Supply Center Columbus (DSCC) when a system
application requires configuration control and which SMD's are applicable to that system. DSCC will maintain a record of users
and this list will be used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronic
devices (FSC 5962) should contact DSCC-VA, telephone (614) 692-0544.
6.4 Comments. Comments on this drawing should be directed to DSCC-VA, Columbus, Ohio 43218-3990, or telephone (614)
692-0547.
6.5 Abbreviations, symbols, and definitions. The abbreviations, symbols, and definitions used herein are defined in
MIL-PRF-38535 and MIL-HDBK-1331.
6.6 Sources of supply.
6.6.1 Sources of supply for device classes Q, T and V. Sources of supply for device classes Q, T and V are listed in
QML-38535. The vendors listed in QML-38535 have submitted a certificate of compliance (see 3.6 herein) to DSCC-VA and
have agreed to this drawing.
6.6.2 Approved sources of supply for device class M. Approved sources of supply for class M are listed in MIL-HDBK-103.
The vendors listed in MIL-HDBK-103 have agreed to this drawing and a certificate of compliance (see 3.6 herein) has been
submitted to and accepted by DSCC-VA.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
21
APPENDIX A
APPENDIX A FORMS A PART OF SMD 5962-95630
A.1 SCOPE
A.1.1 Scope. This appendix establishes minimum requirements for microcircuit die to be supplied under the Qualified
Manufacturers List (QML) Program. QML microcircuit die meeting the requirements of MIL-PRF-38535 and the manufacturers
approved QML plan for use in monolithic microcircuits, multi-chip modules (MCMs), hybrids, electronic modules, or devices
using chip and wire designs in accordance with MIL-PRF-38534 are specified herein. Two product assurance classes consisting
of military high reliability (device class Q) and space application (device Class V) are reflected in the Part or Identification
Number (PIN). When available a choice of Radiation Hardness Assurance (RHA) levels are reflected in the PIN.
A.1.2 PIN. The PIN is as shown in the following example:
5962
⏐
⏐
⏐
Federal
stock class
designator
\
F
⏐
⏐
⏐
RHA
designator
(see 10.2.1)
95630
02
⏐
⏐
⏐
Device
type
(see 10.2.2)
/
V
⏐
⏐
⏐
Device
class
designator
(see 10.2.3)
9
⏐
⏐
⏐
Die
code
A
⏐
⏐
⏐
Die
Details
(see 10.2.4)
\/
Drawing number
A.1.2.1 RHA designator. Device classes Q and V RHA identified die shall meet the MIL-PRF-38535 specified RHA levels. A
dash (-) indicates a non-RHA die.
A.1.2.2 Device type(s). The device type(s) shall identify the circuit function as follows:
Device type
Generic number
02
HS-1840ARH
Circuit function
Radiation hardened DI single 16-channel
analog MUX / DEMUX with high impedance
analog input overvoltage protection
A.1.2.3 Device class designator.
Device class
Q or V
Device requirements documentation
Certification and qualification to the die requirements of MIL-PRF-38535
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
22
APPENDIX A
APPENDIX A FORMS A PART OF SMD 5962-95630
A.1.2.4. Die Details. The die details designation shall be a unique letter which designates the die’s physical dimensions,
bonding pad location(s) and related electrical function(s), interface materials, and other assembly related information, for each
product and variant supplied to this appendix.
A.1.2.4.1 Die physical dimensions.
Die type
Figure number
02
A-1
A.1.2.4.2. Die bonding pad locations and electrical functions.
Die type
Figure number
02
A-1
A.1.2.4.3. Interface materials.
Die type
Figure number
02
A-1
A.1.2.4.4. Assembly related information.
Die type
Figure number
02
A-1
A.1.3. Absolute maximum ratings. See paragraph 1.3 within the body of this drawing for details.
A.1.4 Recommended operating conditions. See paragraph 1.4 within the body of this drawing for details.
A.2. APPLICABLE DOCUMENTS.
A.2.1 Government specifications, standards, and handbooks. Unless otherwise specified, the following specification,
standard, and handbook of the issue listed in that issue of the Department of Defense Index of Specifications and Standards
specified in the solicitation, form a part of this drawing to the extent specified herein.
DEPARTMENT OF DEFENSE SPECIFICATION
MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for.
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-883
- Test Method Standard Microcircuits.
DEPARTMENT OF DEFENSE HANDBOOK
MIL-HDBK-103 - List of Standard Microcircuit Drawings.
(Copies of these documents are available online at http://assist.daps.dla.mil/quicksearch/ or http://assist.daps.dla.mil or
from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
23
APPENDIX A
APPENDIX A FORMS A PART OF SMD 5962-95630
A.2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text
of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a
specific exemption has been obtained.
A.3 REQUIREMENTS
A.3.1 Item requirements. The individual item requirements for device classes Q and V shall be in accordance with
MIL-PRF-38535 and as specified herein or as modified in the device manufacturer’s Quality Management (QM) plan. The
modification in the QM plan shall not affect the form, fit or function as described herein.
A.3.2 Design, construction and physical dimensions. The design, construction and physical dimensions shall be as specified
in MIL-PRF-38535 and the manufacturer’s QM plan, for device classes Q and V.
A.3.2.1 Die physical dimensions. The die physical dimensions shall be as specified in A.1.2.4.1 and on figure A-1.
A.3.2.2 Die bonding pad locations and electrical functions. The die bonding pad locations and electrical functions shall be as
specified in A.1.2.4.2 and on figure A-1.
A.3.2.3 Interface materials. The interface materials for the die shall be as specified in A.1.2.4.3 and on figure A-1.
A.3.2.4 Assembly related information. The assembly related information shall be as specified in A.1.2.4.4 and figure A-1.
A.3.2.5 Truth table. The truth table shall be as defined within paragraph 3.2.3 of the body of this document.
A.3.2.6 Radiation exposure circuit. The radiation exposure circuit shall be as defined within paragraph 3.2.5 herein.
A.3.3 Electrical performance characteristics and post irradiation parameter limits. Unless otherwise specified herein, the
electrical performance characteristics and post irradiation parameter limits are as specified in table I of the body of this
document.
A.3.4 Electrical test requirements. The wafer probe test requirements shall include functional and parametric testing sufficient
to make the packaged die capable of meeting the electrical performance requirements in table I.
30.5 Marking. As a minimum, each unique lot of die, loaded in single or multiple stack of carriers, for shipment to a
customer, shall be identified with the wafer lot number, the certification mark, the manufacturer’s identification and the PIN listed
in A.1.2 herein. The certification mark shall be a “QML” or “Q” as required by MIL-PRF-38535.
A.3.6 Certification of compliance. For device classes Q and V, a certificate of compliance shall be required from a QML38535 listed manufacturer in order to supply to the requirements of this drawing (see A.6.4 herein). The certificate of compliance
submitted to DSCC-VA prior to listing as an approved source of supply for this appendix shall affirm that the manufacturer’s
product meets, for device classes Q and V, the requirements of MIL-PRF-38535 and the requirements herein.
A.3.7 Certificate of conformance. A certificate of conformance as required for device classes Q and V in MIL-PRF-38535
shall be provided with each lot of microcircuit die delivered to this drawing.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
24
APPENDIX A
APPENDIX A FORMS A PART OF SMD 5962-95630
A.4 VERIFICATION
A.4.1 Sampling and inspection. For device classes Q and V, die sampling and inspection procedures shall be in accordance
with MIL-PRF-38535 or as modified in the device manufacturer’s Quality Management (QM) plan. The modifications in the QM
plan shall not effect the form, fit or function as described herein.
A.4.2 Screening. For device classes Q and V, screening shall be in accordance with MIL-PRF-38535, and as defined in the
manufacturer’s QM plan. As a minimum it shall consist of:
a)
Wafer lot acceptance for Class V product using the criteria defined within MIL-STD-883 test method 5007.
b)
100% wafer probe (see paragraph A.3.4).
c)
100% internal visual inspection to the applicable class Q or V criteria defined within MIL-STD-883 test method 2010 or
the alternate procedures allowed within MIL-STD-883 test method 5004.
A.4.3 Conformance inspection.
A.4.3.1 Group E inspection. Group E inspection is required only for parts intended to be identified as radiation assured (see
A.3.5 herein). RHA levels for device classes Q and V shall be as specified in MIL-PRF-38535. End point electrical testing of
packaged die shall be as specified in table IIA herein. Group E tests and conditions are as specified within paragraphs 4.4.4.1,
4.4.4.1.1, 4.4.4.2, 4.4.4.3, and 4.4.4.4.
A.5 DIE CARRIER
A.5.1 Die carrier requirements. The requirements for the die carrier shall be accordance with the manufacturer’s QM plan or
as specified in the purchase order by the acquiring activity. The die carrier shall provide adequate physical, mechanical and
electrostatic protection.
A.6 NOTES
A.6.1 Intended use. Microcircuit die conforming to this drawing are intended for use in microcircuits built in accordance with
MIL-PRF-38535 or MIL-PRF-38534 for government microcircuit applications (original equipment), design applications and
logistics purposes.
A.6.2 Comments. Comments on this appendix should be directed to DSCC-VA, Columbus, Ohio, 43218-3990 or telephone
(614)-692-0547.
A.6.3 Abbreviations, symbols and definitions. The abbreviations, symbols, and definitions used herein are defined within
MIL-PRF-38535 and MIL-STD-1331.
A.6.4 Sources of supply for device classes Q and V. Sources of supply for device classes Q and V are listed in QML-38535.
The vendors listed within QML-38535 have submitted a certificate of compliance (see A.3.6 herein) to DSCC-VA and have
agreed to this drawing.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
25
APPENDIX A
APPENDIX A FORMS A PART OF SMD 5962-95630
NOTE: Pad numbers reflect terminal numbers when placed in case outlines X and Y (see figure 1).
Die physical dimensions.
Die size: 4080 microns x 2820 microns.
Die thickness: 19 ± 1 mils.
Interface materials.
Top metallization: Al Si Cu 16.0 kÅ ±2 kÅ
Backside metallization: None
Glassivation.
Type: PSG
Thickness: 8.0 kÅ ±1.0 kÅ
Substrate: DI (dielectric isolation)
Assembly related information.
Substrate potential: Unbiased
Special assembly instructions: None
FIGURE A-1. Die bonding pad locations and electrical functions.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-95630
A
REVISION LEVEL
G
SHEET
26
STANDARD MICROCIRCUIT DRAWING BULLETIN
DATE: 06-02-24
Approved sources of supply for SMD 5962-95630 are listed below for immediate acquisition information only and shall
be added to MIL-HDBK-103 and QML-38535 during the next revision. MIL-HDBK-103 and QML-38535 will be revised
to include the addition or deletion of sources. The vendors listed below have agreed to this drawing and a certificate
of compliance has been submitted to and accepted by DSCC-VA. This information bulletin is superseded by the next
dated revision of MIL-HDBK-103 and QML-38535. DSCC maintains an online database of all current sources of
supply at http://www.dscc.dla.mil/Programs/Smcr/.
Standard
microcircuit drawing
PIN 1/
Vendor
CAGE
number
Vendor
similar
PIN 2/
5962R9563001VXC
3/
HS1-1840RH-Q
5962R9563001VYC
3/
HS9-1840RH-Q
5962R9563001QXC
3/
HS1-1840RH-8
5962R9563001QYC
3/
HS9-1840RH-8
5962F9563002VXC
34371
HS1-1840ARH-Q
5962F9563002VYC
34371
HS9-1840ARH-Q
5962F9563002QXC
34371
HS1-1840ARH-8
5962F9563002QYC
34371
HS9-1840ARH-8
5962F9563002V9A
34371
HS0-1840ARH-Q
5962R9563002TXC
34371
HS1-1840ARH-T
5962R9563002TYC
3/
HS9-1840ARH-T
1/ The lead finish shown for each PIN representing a hermetic
package is the most readily available from the manufacturer
listed for that part. If the desired lead finish is not listed
contact the vendor to determine its availability.
2/ Caution. Do not use this number for item acquisition. Items
acquired to this number may not satisfy the performance
requirements of this drawing.
3/ No longer available from an approved source of supply.
1 of 2
STANDARD MICROCIRCUIT DRAWING BULLETIN - Continued
Vendor CAGE
number
Vendor name
and address
34371
Intersil Corporation
2401 Palm Bay Blvd.
P.O. Box 883
Melbourne, FL 32902-0883
The information contained herein is disseminated for convenience only and the
Government assumes no liability whatsoever for any inaccuracies in the
information bulletin.
2 of 2
REVISIONS
LTR
DESCRIPTION
DATE (YR-MO-DA)
APPROVED
REV
SHEET
REV
SHEET
15
16
17
REV STATUS
REV
OF SHEETS
SHEET
PMIC N/A
PREPARED BY
Steve Duncan
STANDARD
MICROCIRCUIT
DRAWING
THIS DRAWING IS
AVAILABLE
FOR USE BY ALL
DEPARTMENTS
AND AGENCIES OF THE
DEPARTMENT OF DEFENSE
AMSC N/A
1
2
3
4
5
8
9
10
11
12
13
http://www.dscc.dla.mil/
MICROCIRCUIT, HYBRID, LINEAR,
16 CHANNEL, ANALOG MULTIPLEXER
DRAWING APPROVAL DATE
10-03-02
REVISION LEVEL
SIZE
CAGE CODE
A
67268
SHEET
DSCC FORM 2233
APR 97
7
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
CHECKED BY
Greg Cecil
APPROVED BY
Charles F. Saffle
6
1 OF
5962-09229
17
5962-E415-09
14
1. SCOPE
1.1 Scope. This drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A
choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When
available, a choice of radiation hardness assurance levels are reflected in the PIN.
1.2 PIN. The PIN shall be as shown in the following example:
5962



Federal
stock class
designator
\



RHA
designator
(see 1.2.1)
09229
01



Device
type
(see 1.2.2)
/
K



Device
class
designator
(see 1.2.3)
X



Case
outline
(see 1.2.4)
C



Lead
finish
(see 1.2.5)
\/
Drawing number
1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA
levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device.
1.2.2 Device type(s). The device type(s) identify the circuit function as follows:
Device type
Generic number
01
MUX8520
02
MUX8521
Circuit function
16 channel analog multiplexer, high impedance analog
input, single output with ESD protection
16 channel analog multiplexer, high impedance analog
input, kelvin measurement configuration with ESD protection
1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level.
All levels are defined by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K,
and E) or QML Listing (Class G and D). The product assurance levels are as follows:
Device class
Device performance documentation
K
Highest reliability class available. This level is intended for use in space
applications.
H
Standard military quality class level. This level is intended for use in applications
where non-space high reliability devices are required.
G
Reduced testing version of the standard military quality class. This level uses the
Class H screening and In-Process Inspections with a possible limited temperature
range, manufacturer specified incoming flow, and the manufacturer guarantees (but
may not test) periodic and conformance inspections (Group A, B, C, and D).
E
Designates devices which are based upon one of the other classes (K, H, or G)
with exception(s) taken to the requirements of that class. These exception(s) must
be specified in the device acquisition document; therefore the acquisition document
should be reviewed to ensure that the exception(s) taken will not adversely affect
system performance.
D
Manufacturer specified quality class. Quality level is defined by the manufacturers
internal, QML certified flow. This product may have a limited temperature range.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-09229
A
REVISION LEVEL
SHEET
2
1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows:
Outline letter
Descriptive designator
Terminals
Package style
See figure 1
56
Ceramic quad flat pack
X
1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534.
1.3 Absolute maximum ratings. 1/
Positive supply voltage between +VEE and GND .......................
Negative supply voltage between -VEE and GND.......................
VREF to GND...............................................................................
Digital input overvoltage range:
VEN (pin 13) device types 01and 02 ......................................
VA (pins 14, 15, 16, and 17)....................................................
Analog input overvoltage range .................................................
Power dissipation (PD), TC = -55°C to +125°C:
Device type 01........................................................................
Device type 02........................................................................
Thermal resistance junction-to-case (θJC) ..................................
Storage temperature ..................................................................
Lead temperature (soldering, 10 seconds) ................................
+16.5 V dc
-16.5 V dc
+16.5 V dc
(< VREF + 4)V, (> GND - 4)V
(< VREF + 4)V, (> GND - 4)V
-18 V dc ≤ VIN ≤ +18 V dc
16.5 mW
33 mW
10°C/W 2/
-65°C to +150°C
+300°C
1.4 Recommended operating conditions.
Positive supply voltage (+VEE) 3/ ...............................................
Negative supply voltage (-VEE) 3/...............................................
VREF 3/........................................................................................
Logic low level voltage (VAL) ......................................................
Logic high level voltage (VAH) ....................................................
Case operating temperature range (TC).....................................
+15 V dc
-15 V dc
+5 V dc
+0.8 V dc
+4.0 V dc
-55°C to +125°C
2. APPLICABLE DOCUMENTS
2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part
of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the
solicitation or contract.
DEPARTMENT OF DEFENSE SPECIFICATIONS
MIL-PRF-38534 - Hybrid Microcircuits, General Specification for.
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-883 - Test Method Standard Microcircuits.
MIL-STD-1835 - Interface Standard Electronic Component Case Outlines.
1/
2/
3/
Stresses above the absolute maximum ratings may cause permanent damage to the device. Extended operation at the
maximum levels may degrade performance and affect reliability.
Based on the maximum power dissipation spread over the multiplexer die.
Supply voltages must be applied simultaneously or with +VEE and -VEE supplies first, followed by the VREF supply.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-09229
A
REVISION LEVEL
SHEET
3
DEPARTMENT OF DEFENSE HANDBOOKS
MIL-HDBK-103 - List of Standard Microcircuit Drawings.
MIL-HDBK-780 - Standard Microcircuit Drawings.
(Copies of these documents are available online at https://assist.daps.dla.mil/quicksearch/ or from the Standardization
Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text
of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a
specific exemption has been obtained.
3. REQUIREMENTS
3.1 Item requirements. The individual item performance requirements for device classes D, E, G, H, and K shall be in
accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534 shall include the performance of all tests herein or as
designated in the device manufacturer's Quality Management (QM) plan or as designated for the applicable device class. The
manufacturer may eliminate, modify or optimize the tests and inspections herein, however the performance requirements as
defined in MIL-PRF-38534 shall be met for the applicable device class. In addition, the modification in the QM plan shall not
affect the form, fit, or function of the device for the applicable device class.
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified
in MIL-PRF-38534 and herein.
3.2.1 Case outline(s). The case outline(s) shall be in accordance with 1.2.4 herein and figure 1.
3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2.
3.2.3 Truth table(s). The truth table(s) shall be as specified on figure 3.
3.2.4 Switching waveform(s). The switching waveform(s) shall be as specified on figure 4.
3.2.5 Block diagram. The block diagram shall be as specified on figure 5.
3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are
as specified in table I and shall apply over the full specified operating temperature range.
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical
tests for each subgroup are defined in table I.
3.5 Marking of device(s). Marking of device(s) shall be in accordance with MIL-PRF-38534. The device shall be marked with
the PIN listed in 1.2 herein. In addition, the manufacturer's vendor similar PIN may also be marked.
3.6 Data. In addition to the general performance requirements of MIL-PRF-38534, the manufacturer of the device described
herein shall maintain the electrical test data (variables format) from the initial quality conformance inspection group A lot sample,
for each device type listed herein. Also, the data should include a summary of all parameters manually tested, and for those
which, if any, are guaranteed. This data shall be maintained under document revision level control by the manufacturer and be
made available to the preparing activity (DSCC-VA) upon request.
3.7 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to supply to this
drawing. The certificate of compliance (original copy) submitted to DSCC-VA shall affirm that the manufacturer's product meets
the performance requirements of MIL-PRF-38534 and herein.
3.8 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38534 shall be provided with each lot of
microcircuits delivered to this drawing.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-09229
A
REVISION LEVEL
SHEET
4
TABLE I. Electrical performance characteristics.
Test
Symbol
Supply currents
+IEE
-IEE
+ISBY
-ISBY
Address input
current
IAL(0-3)A
IAH(0-3)A
Enable input
current
IENL(0-15)
IENH(0-15)
Group A
subgroups
Conditions 1/ 2/
-55°C ≤ TC ≤ +125°C
unless otherwise specified
VEN(0-15) = VA(0-3) = 0
1,2,3
VEN(0-15) = VA(0-3) = 0
1,2,3
VEN(0-15) = 4 V, VA(0-3) = 0 3/
1,2,3
VEN(0-15) = 4 V, VA(0-3) = 0 3/
1,2,3
VA = 0 V
1,2,3
VA = 5 V
1,2,3
VEN(0-15) = 0 V
1,2,3
VEN(0-15) = 5 V
1,2,3
Device
types
Limits
Unit
Min
Max
01
0.05
0.5
02
0.1
1
01
-0.5
-0.05
02
-1
-0.1
01
0.05
0.5
02
0.1
1
01
-0.5
-0.05
02
-1
-0.1
01
-1
1
02
-2
2
01
-1
1
02
-2
2
01
-1
1
02
-2
2
01
-1
1
02
-2
2
mA
mA
mA
mA
µA
µA
µA
µA
See footnotes at end of table.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-09229
A
REVISION LEVEL
SHEET
5
TABLE I. Electrical performance characteristics - Continued.
Test
Symbol
Conditions 1/ 2/
-55°C ≤ TC ≤ +125°C
unless otherwise specified
Group A
subgroups
Device
types
Limits
Unit
Min
Max
Positive input
leakage current
(CH0-CH15)
+ISOFFOUTPUT(ALL)
VIN = +10 V, VEN = 4 V, output
and all unused inputs = -10 V
4/ 5/
1,2,3
All
-100
+700
nA
Negative input
leakage current
(CH0-CH15)
-ISOFFOUTPUT(ALL)
VIN = -10 V, VEN = 4 V, output
and all unused inputs = +10 V
4/ 5/
1,2,3
All
-100
+700
nA
Positive output
leakage current
outputs (pin 12)
for device 01
and (pins 12 and
45) for device
type 02
+IDOFFOUTPUT(ALL)
VOUT = +10 V, VEN = 4 V, output
and all unused inputs = -10 V
5/ 6/
1,2,3
All
-100
+100
nA
Negative output
leakage current
outputs (pin 12)
for device 01
and (pins 12 and
45) for device
type 02
-IDOFFOUTPUT(ALL)
VOUT = -10 V, VEN = 4 V, output
and all unused inputs = +10 V
5/ 6/
1,2,3
All
-100
+100
nA
Input clamped
voltage
(CH0-CH15)
+VCLMP
VEN = 4 V, all unused inputs are
open 5/
1
All
18.0
23.0
V
2
18.0
23.5
3
17.5
22.5
-23.0
-18.0
2
-23.5
-18.0
3
-22.5
-17.5
-VCLMP
1
VEN = 4 V, all unused inputs are
open 5/
All
V
See footnotes at end of table.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-09229
A
REVISION LEVEL
SHEET
6
TABLE I. Electrical performance characteristics - Continued.
Test
Symbol
Switch ON
resistance outputs
(pin 12) for device
type 01 and (pins
12 and 45) for
device type 02
Switching tests
Conditions 1/ 2/
-55°C ≤ TC ≤ +125°C
unless otherwise specified
Group A
subgroups
Device
types
Limits
Unit
Min
Max
RDS(ON)(0-15)A
VIN = +15 V, VEN = 0.8 V,
IOUT = -1 mA 4/ 5/ 7/
1,2,3
All
500
3000
Ω
RDS(ON)(0-15)B
VIN = +5 V, VEN = 0.8 V,
IOUT = -1 mA 4/ 5/ 7/
1,2,3
All
500
3000
Ω
RDS(ON)(0-15)C
VIN = -5 V, VEN = 0.8 V,
IOUT = +1 mA 4/ 5/ 7/
1,2,3
All
500
3000
Ω
tAHL
RL = 10 kΩ, CL = 50 pF,
See figure 4
9,10,11
All
10
1500
ns
tALH
RL = 10 kΩ, CL = 50 pF,
See figure 4
9,10
All
10
2000
ns
10
5000
11
tONEN
RL = 1 kΩ, CL = 50 pF,
See figure 4
9,10,11
All
10
1500
ns
tOFFEN
RL = 1 kΩ, CL = 50 pF,
See figure 4
9,10,11
All
10
1000
ns
1/ +VEE = +15 V dc, -VEE = -15 V dc, and VREF = +5 V dc, unless otherwise specified.
2/ Measure inputs sequentially. Ground all unused inputs.
3/ If not tested, shall be guaranteed to the limits specified in table I.
4/ VIN is the applied input voltage to the input channels (CH0-CH15).
5/ VEN is the applied input voltage to the enable lines EN(0-15).
6/ VOUT is the applied input voltage to the output lines OUTPUT(0-15) for device types 01 and 02 and CURRENT(0-15) for
device type 02.
7/ Negative current is the current flowing out of each of the pins. Positive current is the current flowing into each of the
pins.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-09229
A
REVISION LEVEL
SHEET
7
Case outline X.
FIGURE 1. Case outline(s).
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-09229
A
REVISION LEVEL
SHEET
8
Case outline X - Continued.
FIGURE 1. Case outline(s) - Continued.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-09229
A
REVISION LEVEL
SHEET
9
Case outline X - Continued.
Inches
Symbol
Min
Millimeters
Max
A
Min
Max
.190
A1
.139
4.83
.170
3.53
4.32
A2
.005
.011
0.13
0.28
b
.0135
.0195
0.34
0.50
c
.005
.008
0.13
0.20
D/E
.790
.810
20.07
20.57
D1
.645
.655
16.38
16.64
e
.050 BSC
1.27 BSC
F
.200 TYP
5.08 TYP
J
.035 TYP
0.89 TYP
L
2.490
2.510
L1
63.25
63.75
2.580
65.53
L2
1.700
1.740
43.18
44.20
L3
2.090
2.110
53.09
53.59
L4
.650 TYP
16.51 TYP
N
56
56
S1
.030 TYP
0.76 TYP
S2
.015 TYP
0.38 TYP
NOTES:
1. Pin 1 is indicated by an ESD triangle on top of the package and by an index on the bottom of the package.
2. The U.S. preferred system of measurement is the metric SI. This item was designed using inch-pound units of
measurement. In case of problems involving conflicts between the metric and inch-pound units, the inch-pound
units shall rule.
3. N equals 56, the total number of leads on the package.
4. Pin numbers are for reference only.
FIGURE 1. Case outline(s) - Continued.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-09229
A
REVISION LEVEL
SHEET
10
Device types
01 and 02
Case outline
Terminal
number
Terminal symbol
X
Terminal
number
Terminal symbol
1
CH0
29
NC
2
CH1
30
NC
3
CH2
31
NC
4
CH3
32
NC
5
CH4
33
NC
6
CH5
34
NC
7
GND
35
GND
8
GND
36
GND
9
CH6
37
NC
10
CH7
38
NC
11
CASE GND
39
VREF
12
OUTPUT(0-15)
40
NC
13
EN (0 − 15)
41
NC
14
A0
42
NC
15
A1
43
NC
16
A2
44
NC
17
A3
45
See Note 1
18
+VEE
46
-VEE
19
CH15
47
NC
20
CH14
48
NC
21
GND
49
GND
22
GND
50
GND
23
CH13
51
NC
24
CH12
52
NC
25
CH11
53
NC
26
CH10
54
NC
27
CH9
55
NC
28
CH8
56
NC
NOTE:
1. No connect for device type 01 and CURRENT(0-15) for device type 02.
2. NC is a no connect pin. NC pins should be grounded to eliminate or minimize electrostatic
discharge (ESD) or static buildup.
3. Package lid is internally connected to circuit ground (Pins 7, 8, 11, 21, 22, 35, 36, 49, and 50).
FIGURE 2. Terminal connections.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-09229
A
REVISION LEVEL
SHEET
11
Truth table (CH0-CH15)
A3
A2
A1
A0
EN (0-15)
"ON" Channel 1/
X
X
X
X
H
None
L
L
L
L
L
L
L
H
L
L
CH0
CH1
L
L
L
L
H
H
L
H
L
L
CH2
CH3
L
L
H
H
L
L
L
H
L
L
CH4
CH5
L
L
H
H
H
H
L
H
L
L
CH6
CH7
H
H
L
L
L
L
L
H
L
L
CH8
CH9
H
H
L
L
H
H
L
H
L
L
CH10
CH11
H
H
H
H
L
L
L
H
L
L
CH12
CH13
H
H
H
H
H
H
L
H
L
L
CH14
CH15
1/ Between (CH0-CH15) and OUTPUT(0-15) for device type 01, and between (CH0-CH15) and
OUTPUT(0-15) and CURRENT(0-15) for device type 02.
FIGURE 3. Truth table.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-09229
A
REVISION LEVEL
SHEET
12
DEFINTION OF tAHL
DEFINTION OF tALH
DEFINITION OF tONEN AND tOFFEN
NOTE: f = 10 kHz, duty cycle = 50%.
FIGURE 4. Switching test waveform(s).
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-09229
A
REVISION LEVEL
SHEET
13
FIGURE 5. Block Diagram.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-09229
A
REVISION LEVEL
SHEET
14
FIGURE 5. Block diagram - Continued.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-09229
A
REVISION LEVEL
SHEET
15
TABLE II. Electrical test requirements.
MIL-PRF-38534 test requirements
Subgroups
(in accordance with
MIL-PRF-38534, group A
test table)
Interim electrical parameters
1, 9
Final electrical parameters
1*, 2, 3, 9, 10, 11
Group A test requirements
1, 2, 3, 9, 10, 11
Group C end-point electrical
parameters
1, 2, 3, 9, 10, 11
End-point electrical parameters
for radiation hardness assurance
(RHA) devices
Not applicable
* PDA applies to subgroup 1.
4. VERIFICATION
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38534 or as
modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan shall not affect the form,
fit, or function as described herein.
4.2 Screening. Screening shall be in accordance with MIL-PRF-38534. The following additional criteria shall apply:
a.
b.
Burn-in test, method 1015 of MIL-STD-883.
(1)
Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to either DSCC-VA or the acquiring activity upon request. Also, the test circuit
shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified
in test method 1015 of MIL-STD-883.
(2)
TA as specified in accordance with table I of method 1015 of MIL-STD-883.
Interim and final electrical test parameters shall be as specified in table II herein, except interim electrical parameter
tests prior to burn-in are optional at the discretion of the manufacturer.
4.3 Conformance and periodic inspections. Conformance inspection (CI) and periodic inspection (PI) shall be in accordance
with MIL-PRF-38534 and as specified herein.
4.3.1 Group A inspection (CI). Group A inspection shall be in accordance with MIL-PRF-38534 and as follows:
a.
Tests shall be as specified in table II herein.
b.
Subgroups 4, 5, 6, 7, and 8 shall be omitted.
4.3.2 Group B inspection (PI). Group B inspection shall be in accordance with MIL-PRF-38534.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-09229
A
REVISION LEVEL
SHEET
16
4.3.3 Group C inspection (PI). Group C inspection shall be in accordance with MIL-PRF-38534 and as follows:
a.
End-point electrical parameters shall be as specified in table II herein.
b.
Steady-state life test, method 1005 of MIL-STD-883.
(1)
Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to either DSCC-VA or the acquiring activity upon request. Also, the test circuit
shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified
in test method 1005 of MIL-STD-883.
(2)
TA as specified in accordance with table I of method 1005 of MIL-STD-883.
(3)
Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
4.3.4 Group D inspection (PI). Group D inspection shall be in accordance with MIL-PRF-38534.
4.3.5 Radiation Hardness Assurance (RHA) inspection. RHA inspection is not currently applicable to this drawing.
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38534.
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications
(original equipment), design applications, and logistics purposes.
6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractorprepared specification or drawing.
6.3 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated as specified in MIL-PRF38534.
6.4 Record of users. Military and industrial users shall inform Defense Supply Center Columbus (DSCC) when a system
application requires configuration control and the applicable SMD. DSCC will maintain a record of users and this list will be
used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronic devices (FSC
5962) should contact DSCC-VA, telephone (614) 692-0544.
6.5 Comments. Comments on this drawing should be directed to DSCC-VA, Columbus, Ohio 43218-3990, or telephone (614)
692-1081.
6.6 Sources of supply. Sources of supply are listed in MIL-HDBK-103 and QML-38534. The vendors listed in MIL-HDBK-103
and QML-38534 have submitted a certificate of compliance (see 3.7 herein) to DSCC-VA and have agreed to this drawing.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-09229
A
REVISION LEVEL
SHEET
17
STANDARD MICROCIRCUIT DRAWING BULLETIN
DATE: 10-03-02
Approved sources of supply for SMD 5962-09229 are listed below for immediate acquisition information only and
shall be added to MIL-HDBK-103 and QML-38534 during the next revisions. MIL-HDBK-103 and QML-38534 will be
revised to include the addition or deletion of sources. The vendors listed below have agreed to this drawing and a
certificate of compliance has been submitted to and accepted by DSCC-VA. This information bulletin is superseded
by the next dated revisions of MIL-HDBK-103 and QML-38534. DSCC maintains an online database of all current
sources of supply at http://www.dscc.dla.mil/Programs/Smcr/.
1/
2/
Standard
microcircuit drawing
PIN 1/
Vendor
CAGE
number
Vendor
similar
PIN 2/
5962-0922901KXC
88379
MUX8520-201-1S
5962-0922902KXC
88379
MUX8521-201-1S
The lead finish shown for each PIN representing a hermetic package is the most readily available from the
manufacturer listed for that part. If the desired lead finish is not listed contact the Vendor to determine its
availability.
Caution. Do not use this number for item acquisition. Items acquired to this number may not satisfy the
performance requirements of this drawing.
Vendor CAGE
number
88379
Vendor name
and address
Aeroflex Plainview Incorporated,
(Aeroflex Microelectronics Solutions)
35 South Service Road
Plainview, NY 11803-4193
The information contained herein is disseminated for convenience only and the
Government assumes no liability whatsoever for any inaccuracies in the
information bulletin.