ACT7005/ACT7006 Single Pkg MIl-STD-1553 Solution (3/05)

ACT7005 / ACT7006 Single Package MIL-STD-1553 Solution
Dual Transceiver, Protocol, Subsystem Interface
March 6, 2005
www.aeroflex.com/Avionics
FEATURES
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
Incorporates Dual Transceivers, MIL-STD-1553 Protocol, and System Interface Components into a
Single Hybrid Package
Functions as a Remote Terminal or Bus Controller
Interfaces to µP as a Simple Peripheral Unit
+5V Operation
Provides 2k by 16 of Double Buffered RAM Storage for Transmit and Receive Subaddresses
Pin Programmable for 8-bit or 16-bit Microprocessors
Full Military (-55°C to +125°C) Temperature Range
Designed for Commercial, Industrial And Aerospace Applications
Aeroflex-Plainview is a Class H & K MIL-PRF-38534 manufacturer
MIL-PRF-38534 Compliant Circuits Available
Packaging – Hermetic Ceramic, 90 Pin, 2.6" x 1.6" x .225" Plug-In Type Package
DESCRIPTION
The ACT7005/6 Series provides a complete one package interface between the MIL-STD-1553 bus and all
microprocessor systems. The hybrid provides all data buffers and control registers to function as a Bus Controller or
Remote Terminal. Control of the hybrid by the subsystem is through simple I/O port commands. Internal hybrid logic
removes all critical timing imposed on a typical subsystem, thereby simplifying the implementation of this interface.
INTERRUPTS/
CONTROL
SIGNALS
µP
INTERFACE
S
U
B
S
Y
S
T
E
M
BUS "0"
DUAL
TX/RX
1553
PROTOCOL
RAM
8/16
BIT
I/O
BUS "1"
ACT7005 / ACT7006
BLOCK DIAGRAM
SCD7005 Rev C
BUS "1"
BUS "0"
SCD7005 Rev C
2
Terminal
Address
Inputs
Transceiver
"1"
Transceiver
"0"
MUX
MUX
MUX
Driver
Select
and
Enable
1k x 16
RECEIVE
RAM
1k x 16
TRANSMIT
RAM
OUTPUT
FIFO
BUFFER
32 x 16
32 x 16
32 x 16
32 x 16
INPUT
FIFO
BUFFER
TRANSMIT
FIFO
BUFFER
RECEIVE
FIFO
BUFFER
HANDSHAKE and CONTROL SIGNALS
INTERNAL
HIGHWAY
CONTROL
SELF TEST
CIRCUITRY
STATUS
WORD
CONTROL
INTERFACE
UNIT
FIGURE 1 – FUNCTIONAL BLOCK DIAGRAM
DECODER "1"
DECODER "0"
ENCODER
8 BIT INTERNAL HIGHWAY
BI-DIRECTIONAL
I/O DATA BUFFER
DISCRETE INPUT/OUTPUT SIGNALS
ADDRESS
Control Signals and Interrupts
8 or 16 BIT SYSTEMS BUS
ARBITRATION
AND
CONTROL LOGIC
Operation Register
Sync/Stat WD #2/RMD Register
Status Word #1 Register
VW/CMD Word #2/AMD Register
Command Word #1 Register
Receive Command Register
RT Command Word Register
Parameter
Min
Max
Units
Power Supply Voltage (VCC)
-0.3
7.0
V
Power Supply Voltage (VCCL & VDD)
-0.3
7.0
V
Receiver Differential Input
(DATA CH A/B / DATA CH A/B)
-10
+10
V
Receiver Input Voltage
(DATA CH A/B or DATA CH A/B – Common Mode)
-5
+5
V
Operating Case Temperature Range (TC)
-55
+125
°C
Transmission Duty Cycle at TC = +125°C
-
100
%
TABLE 1 – ABSOLUTE MAXIMUM RATINGS
‘
Power Supply Voltage
Total supply current "standby" mode or transmitting at less than
1% duty cycle (e.g. 20µs of transmission every 2ms or longer
interval). 2/
Total supply current transmitting at 1MHz into a 35Ω load at
Point A in Figure 1. 2/ 1/
Symbol
Min
Typ
Max
Unit
VCC
4.75
5
5.5
mA
ICC@1%
18
30
mA
ICC @ 25%
ICC @ 50%
ICC @ 100%
150
300
600
175
350
700
mA
mA
mA
Note:
1/
2/
Decreases linearly to applicable "standyby" values at zero duty cycle.
Represents one channel only.
TABLE 2 – ANALOG TRANSCEIVER POWER SUPPLY CHARACTERISTICS
SCD7005 Rev C
3
Parameter/Condition
Point A
Differential impedance DC to 1MHz,
See Figure 4
Symbol
Min
ZIO
2K
W
1K
W
Point C
Max
Unit
Differential voltage range
VDIR
-10
+10
VPEAK
Input common mode voltage range
VICR
-5
+5
VPEAK
CMRR
40
Point A
VTH1
0.8
1.1
Vp-p
Point C
VTH2
0.56
0.86
Vp-p
Common mode rejection ratio (from point A, Figure 4)
Threshold characteristics (sine wave at 1MHz)
NOTE: Threshold voltages refer Figure 4
dB
TABLE 3 – ANALOG TRANSCEIVER ELECTRICAL CHARACTERISTICS (RECEIVER SECTION)
(OVER FULL TEMPERATURE RANGE)
Parameter / Condition
Differential output level at point B,
See Figure 4
140Ω Point B
Symbol
Min
VO
70Ω Point C
Max
Unit
24
35
Vp-p
18
25
Vp-p
10
mVp-p
VNOI
Differential Output Noise at Point A, See Figure 4
Output Offset at point A in Figure 4, 2.5µs
after mid-bit crossing of parity bit of last
word of a 660µs message
Typ
Point A (35Ω)
Vos1
-90
+90
mV
Point C (70Ω)
Vos2
-250
+250
mV
tR & tF
100
300
ns
Rise and Fall times (10% to 90% of p-p output)
160
TABLE 4 – ANALOG TRANSCEIVER ELECTRICAL CHARACTERISTICS (TRANSMITTER SECTION)
(OVER FULL TEMPERATURE RANGE)
SCD7005 Rev C
4
Symbol
Parameter
Min
Typ
Max
Units
VDD
Logic Supply
4.5
5.0
5.5
VDC
VIH
Input "1"
2.4
VIL
Input "0"
IL
Input I
-450
IIH
Input I
IL
Conditions
V
0.6
V
-600
-900
µA
Note 1A
-250
-400
-750
µA
Note 1B
Input I
-50
-200
-800
µA
Note 1C
IIH
Input I
-50
-200
-800
µA
Note 1D
IL
Input I
-25
-125
-400
µA
Note 2A
IIH
Input I
-25
-125
-400
µA
Note 2B
VOH
Output "1"
2.4
VDC
Note 3A
VOL
Output "0"
0.4
VDC
Note 3B
VDD
Static I
50
mA
Note 4A
VDD
Dynamic I
170
mA
Note 4B
Notes:
1.VDD = 5.5V
A. For RTAD0/1/2/3/4 and RTADPAR with VIL = 0.4V
B. For RTAD0/1/2/3/4 and RTADPAR with VIH = 2.4V
C. FOR BCSTEN WITH VIL = 0.4V, Test 1, 6MHz
D. FOR BCSTEN WITH VIH = 2.4V, Test 1, 6MHz
2.All remaining inputs and I/O
VDD = 5.5V
A. VIL = 0.4V
B. VIH = 2.4V
3. A. VDD = 4.5V and IOH = 3mA
B. VDD = 5.5V and IOL = 3mA
4.VDD = 5.5V
A. Clock Input = 6MHz (45-55% Duty Cycle / TTL Levels), All remaining inputs = VDD,
All Outputs = Open Circuit
B. During a 32 word FIFO to RAM or RAM to FIFO block move.
TABLE 5 – LOGIC ELECTRICAL CHARACTERISTICS
(OVER FULL TEMPERATURE RANGE)
SCD7005 Rev C
5
ACT7005/7006
0.75ZO
TX DATA CH A/B
CT
GND
}
Taps at N1:N3 For
Stub Coupling
(See Table)
C B
A
TX DATA CH A/B
0.75ZO
(N1 : N2)
(See Table)
TURNS RATIO
ACT7005/7006
N1:N2
1:2.5
N1:N3
1:1.79
Technitrol Part #
T-1553-45
FIGURE 2 – TRANSFORMER CONFIGURATION
SCD7005 Rev C
6
For
Direct
Coupling
1553 DATA BUS
+5V
+5V
RT ZO
2
43
3
40
GND
7
R2
8
D15
D14
VCCL
XCEIVERS
6
VCCL
LOGIC
DATA
0.75ZO, 2% 5
DATA
0.75ZO, 2%
U1
54LS245
87 16
+5V (B)
38 53
+5V (A)
DIRECT-COUPLED CONFIGURATION
(SHORT-STUB)
N = 1:2.5
R1
4
1 42
2%
D13
D12
D11
D10
N = 1.4:1
R3, 2%
1
0.75ZO
2
R4, 2%
3
4
N = 1:1.79
4
1 49
5
5
6
6
7
7
8
8
2
50
3
51
0.75ZO
D9
DATA
D8
11
78
12
77
13
76
14
75
15
74
16
73
17
72
18
B8
A8
B7
A7
B6
A6
B5
A5
B4
A4
B3
A3
B2
A2
B1
A1
9
8
7
6
5
4
3
2
D15
D14 (MSB)
D13
D12
D11
D10
D9
D8
A→B EN
GND
DATA
U2
54LS245
TRANSFORMER-COUPLED
CONFIGURATION (LONG-STUB)
RT
79
D7
Zo, 2%
D6
D5
D4
ACT7005/7006
D3
D2
D1
D0
71
11
70
12
69
13
68
14
67
15
66
16
65
17
64
18
RD
WR
A3
A2
A1
A0
A8
B7
A7
B6
A6
B5
A5
B4
A4
B3
A3
B2
A2
B1
A1
9
8
7
6
5
4
3
2
D7
D6
D5
D4
D3
D2
D1
D0 (LSB)
A→B EN
90
DS
B8
DS (Device Select)
88
RD (Read from RT/BC)
89
WR (Write to RT/BC)
84
A3 (MSB)
83
A2
82
A1
81
A0 (LSB)
U3
54LS244
INT *1
INT *2
DONE
41
TRANSCEIVER A
43
44
SELF TEST
62
17
63
15
60
13
54
11
OUTPUT GND
8
ANALOG GND
6
DIGITAL GND
4
2
LOGIC
RTAD0
80
DIGITAL GND
RTAD1
2
ANALOG GND
RTAD2
47
OUTPUT GND
RTAD3
48
RTAD4
TRANSCEIVER B
RTADPAR
50
AD10 OUT 86
85
AD10 IN
28
M 16/8
31
RESET
1
CLOCK
R5
2A4
2Y4
2A3
2Y3
2A2
2Y2
2A1
2Y1
1A4
1Y4
1A3
1Y3
1A2
1Y2
1A1
1Y1
1G
1
2G
19
7
9
12
14
16
18
GOOD BLOCK(RT)/VALID(BC)
VALID TRANS(RT)/INVALID(BC)
DONE
SELF-TEST
These are the recommended
interrupts, but use of them is
optional. The user can select any
combination of interrupts
depending on the needs of the
RT/BC. In addition to the 4
interrupts above, the user can
select from among 8 others to suit
the RT/BC needs.
+5V
FIGURE 3 – TYPICAL INTERFACE CONNECTIONS
7
5
10KΩ
5 Bit RT Address and
Parity Bit. These lines
can be hardwired for an
RT address or they can
be set by jumpers, DIP
switches, or
TTL/CMOS latches.
SCD7005 Rev C
3
Master Reset
6MHz Clock
SINGLE HYBRID
PROTOCOL SUBSYSTEM INTERFACE
transceivers. Control of the transceivers is provided by the
protocol section. This is determined by which bus the
command word was received on in the remote terminal
mode; or in the bus controller mode, which bus was
selected for transmission by the state of a bit in the
operation register. An autonomous self-test can be
performed either off-line or on-line through the transceivers
This self-test is controlled by the operation register and will
be discussed thoroughly in the self-test section. The other
test function is that in addition to the protocol criteria that is
tested during every transmission; i.,e., proper sync
character, 16 data bits, Manchester II coded, contiguous
words, and odd parity, a bit per bit comparison of the
contents of the parallel data will insure a higher degree of
functionality of this section of the hybrid.
KEY FEATURES
• Functional Superset of CT1800
• Downward compatible with existing designs base of
CT1800
• Incorporates Transceivers, Protocol and Interface
Hybrids into a single package
• Functions as a Remote Terminal or Bus Controller
GENERAL
The ACT7005/6 Series provides a complete interface
between the MIL-STD-1553 bus and any micro-processor
system. Functioning as a superset of the CT1800 interface,
the hybrid provides all data buffers and control registers
necessary to implement RT and BC functions. Internal
arbitration and data transfer control circuitry eliminates
subsystem response requirements. All data written into or
read from this interface are double buffered on a message
basis. Only valid and complete receive messages are
transferred into the receive RAM.
Data received by the protocol section will be placed in the
receive FIFO buffer. Transmitted data will be taken from
the transmit FIFO buffer. Other than the remote terminal
address and parity, the discretes to control the resetting of
the terminal flag and subsystem error bits, and a few
discrete interrupts and error signals, control over the
protocol section resides in the operation register of the
subsystem interface section.
The subsystem interface section has primary control of the
data that resides in the 2K of RAM. The RAM is segregated
into two 1K blocks of data, one contains 30 blocks of
transmit data messages and the other one contains 30
blocks of receive data messages. This is not absolute since
the subsystem has control of the A10 bit. Data entries to or
from the RAM are arbitrated by the control logic residing
in this function, and is buffered via FlFO’s on the input
from the protocol section and on the output to the
subsystem’s data bus. This guarantees that only current and
valid data blocks will reside in RAM. This is true for
remote terminal and bus controller applications.
The ACT7005/6 Series supports all 15 mode codes and all
types of data transfers allowed by MIL-STD-1553B. All
circuitry (excluding transceiver drivers) are CMOS, which
results in very low power requirements.
Interfacing to the subsystem is simplified through the use
of tri-stated input/output buffers onto the subsystem bus.
Control signals basically consist of four address lines, a
device select input, read strobe, write strobe, and several
interrupts, the use of which are optional. The Hybrid is
accessed as a memory mapped I/O port of a microprocessor
system. Valid transmission and reception of data are
indicated to the subsystem through the use of interrupts.
This frees up the system processor from actively
monitoring the port until a valid message is received.
Seven dedicated registers are provided to ease the
interfacing with the subsystem. These will be discussed in
the Register Operation section of this document. The
register of primary concern to a subsystem designer is the
operation register. This provides the means to accomplish
data transfers to/from the RAM, as well as control of
remote terminal or bus control modes of operation. All
registers are accessed via simple l/O commands, utilizing
A0 through A3, Device Select, and Read or Write strobes.
OPERATION
The ACT7005/6 Series (Single Package Solution) resides
between a microprocessor interface and a MIL-STD-1553
data bus. The addition of two transformers and fault
isolation resistors are the only external components
required to complete the interface. Information on the bus
is received or transmitted through the transceiver
(converted from Manchester II to complimentary TTL
signals and visa versa) to the protocol section. The
ACT7005/6 Series incorporates a single +5VDC only
transceiver.
Receive Commands
When a valid receive command is received, it is first
loaded into the Command Word Register. The data words
associated with this command are received, validated, and
loaded one by one into the RCV FIFO buffer. Once the
entire message is received, and only if the complete block
The protocol section internally interfaces to the
SCD7005 Rev C
8
RT to RT commands, BUS selection and RETRY
initialization of a faulty transaction.
of data is valid, will the command word be transferred to
the RCV Command Register. This block of data is then
burst (by the internal controller) into the corresponding
internal RAM location, which is memory mapped by the
subaddress contained in the RCV Command Register. Once
this operation is complete, a discrete interrupt pulse called
INT #1 is sent the subsystem.
A typical Bus Control transaction would operate as
follows: All areas of internal RAM that will be used for
transmission are initialized by the subsystem with the
desired data. To accomplish this, the subsystem will first
WRITE to the INPUT buffer the number of words to be
transferred. This information is now transferred to the
internal RAM under control of the OPERATION register
by specifying the subaddress bits 0-4, setting the T/R bit
(bit 5) and l/O bit (bit 6) high. This will be executed by
issuing an EXECUTE operation l/O command. When the
transfer has been completed, the DONE interrupt will pulse
low, and valid data will now reside in this RAM location.
Next, the subsystem will write the command word to
COMMAND WORD #1 register. If it were an RT-to-RT
transfer, the transmitting RT command word would be
written into COMMAND WORD #2 register. The next
register to be intitialized would be the OPERATION
register, which controls which bus to transmit on and if
retry will be an option. This information will be enacted
upon when the subsystem issues a TRIGGER I/O
command. The return status word from the remote terminal
or status words for RT-to-RT transfers will reside in their
appropriate registers upon the issuance of INT #1. If the
RETRY option had been selected and a valid transfer had
not occurred, the RETRY interrupt would have occurred
instead of INT #1. Three retrys are the maximum number
allowed. The retrys can be accomplished on the primary or
secondary bus determined by programming bits in the
operation register.
If this interrupt is used, the subsystem would read the
command word from the RCV Command Register. The
data could then be transferred to the OUTPUT FIFO buffer,
and read by the subsystem. Each receive subaddress section
of the internal RAM will contain only the most recent,
valid, and complete block of data to that subaddress. This is
true for Remote Terminal and Bus Controller operations.
Transmit Commands
If a valid transmit command is received, the command
word is first loaded into the Command Word Register. The
block of data corresponding to the subaddress of the
transmit command is then transferred from the internal
RAM to the XMIT FIFO buffer. Upon completion of this
transfer, INT #2 is sent to the subsystem.
The transmit section of the internal RAM is generally
initialized at power up and periodically updated as
required.
Appropriate subsystem response to INT #2 for an RT
implementation would be to read the command word from
the Command Word Register. The data to this subaddress
could now be refreshed in preparation for the next time it
was requested to be transmitted across the 1553 bus.
A retry will be initiated if the retry bits are set in the
OPERATION register. The criteria for attempting a retry is
the lack of a returned status word or returned mode data, or
that 768µsec has transpired since the start of the data
transfer. A retry will not be executed if bits are set in the
return status word(s); this is up to the subsystem to interpret
the status word contents and to reinitiate the transfer if
desired.
Mode Codes
All 15 mode codes are serviced by the protocol section,
and most do not require subsystem intervention. Discrete
interrupt signals are available for each of the Synchronize
(with and without data), Vector Word, Reset, and Dynamic
Bus Control Acceptance mode codes. Mode command
words are loaded into the Command Word Register.
Separate registers are provided for the synchronize data
word and the vector data words.
Discrete Interrupts
Twelve discrete interrupt output signals are available for
the subsystem interface. Any or all of these may be used
depending on subsystem requirements. Excluding the
signal BUFF EF, all interrupts are low going pulse signals.
Interrupt and status signals RESET, DBCREQ, and NBGT
are 500ns wide nominally, and VECTOR is typically 1.5µs
wide. All remaining interrupts are nominally 160ns.
Bus Control Operation
Upon initialization of power to the ACT7005/6 Series, all
registers are reset. The operation register is reset to FF80H;
this setting defaults to the remote terminal mode of
operation with the Busy Bit set. To enter into the Bus
Control Mode of operation, bit 8 of the operation register
must be asserted low. While in this mode, the upper byte (8
bits) of the operation register controls Bus Control
functionality. This includes TEST/NORMAL operation,
The output buffer empty flag (BUFF EF), which is a level,
is also made available for subsystem use. When low, it
indicates the output buffer is empty. See Table 6 for
additional information.
SCD7005 Rev C
9
REGISTER SUMMARY
to the Internal RAM. (See note below.) This register also
provides software control of the DBCACC, SERVREQ,
and SSERR bits of the status word. Following power-up
master reset, bit 7 of this register will be set high. This bit
corresponds to the busy bit of the Remote Terminal Status
Word. The subsystem reads and writes to this register under
l/O commands. The transfer functions defined by this
register are executed by either of the two l/O EXECUTE
Commands.
Remote Terminal Command Word Register: This
Register is utilized in the RT mode and is read only. It
contains all valid received command words, i.e. transmit,
receive, and mode command.
Receive Command Word Register: After the reception
of a valid receive message, and the GOOD BLOCK
interrupt has been issued, the Receive Command word will
be transferred from the Remote Terminal Command Word
Register to this register. The purpose of double buffering
receive command words is to maximize the time a
subsystem has to read this command since GOOD BLOCK
comes at the end of the data transfer, and the next command
word could overwrite the contents of the Remote Terminal
Command Word Register. This is a READ ONLY register
in RT mode.
Note: The Internal RAM is divided into transmit or
receive sections. In general, data is written to the transmit
section and read from the receive section. However, either
section may be read from or written to via the T/R bit in
this register.
SELF TEST
The inclusion of simple wraparound self test circuitry in
the protocol section insures that a high percentage of
coverage is attainable. Testing requires simple subsystem
intervention. A word is first placed in the VECTOR WORD
Register. Test bit 9 in the OPERATION Register is asserted
low and the l/O TEST TRIGGER address is written. The
LT LOCAL (Bit 10 of the Operation Register) determines if
this will be an ON/OFF line test. OFF line tests are
performed by the inclusion of digital multiplexers in front
of the encoder, bypassing the transceiver, providing a path
to the decoder. The ON line tests are accomplished when
not connected to a bus network, such as a maintenance test
station, since this test utilizes the transceiver to provide the
loop back path instead of the internal multiplexers. In this
mode test words would appear on the bus. First, the
primary bus will be tested with the data that resides in the
VECTOR WORD Register. It is encoded then looped back,
decoded and presented to the subsystem as a normal data
transfer would be accomplished. This word will be stored
in the RT Command Word Register. The secondary bus is
sequentially tested after the primary bus is completed,
utilizing the word residing in the VECTOR WORD
Register. Upon successful completion of the test, the PASS
interrupt will be asserted low.
Command Word #1 Register: This register contains the
first command word to be transmitted during an RT to RT
transfer, or the command word for a BC to RT, or RT to BC
transfer. This register is a read or write register.
Vector Word/Command Word #2 Associated Mode
Data Register: This register is used to accomplish multiple
functions in Bus Controller and Remote Terminal Modes.
In BC Mode it will contain the second command word for
(RT to RT) transfers, or Associated Mode Data that is
required by certain mode codes; i.e., Sync (with data).
When operated in the RT Mode, this register contains the
Vector Word required by mode code Transmit Vector Word
Command.
STATUS Word #1 Register: The utilization of this
register in the BC mode is read only. It contains the
returned status word for BC to RT, RT to BC mode, or the
first returned status in RT to RT mode. At reset or the
initiation of a bus transfer, the contents of this register will
be set to all high, FFFFH.
Synchronize/Status Word #2/ Return Mode Data
Register: In Bus Controller mode this register will either
contain the second returned status word for RT to RT
transfers or the returned mode data; i.e., BIT word or
Vector word, Last Status word, or Last Command word. In
BC mode this register is initialized to all highs, FFFFH.
Unlike the other status word register, this does function in
the RT mode, but is still read only in either mode. In RT
mode it will contain the SYNC data word received in
association with the Synchronize with Data Mode Code.
In addition to this test of the protocol section, the
subsystem data handling capability is also testable via the
OPERATION Register. This is accomplished by writing a
message to the INPUT FIFO Buffer; this data can be placed
in any location determined by the SA0 through SA4 Bits, or
in either the transmit or receive section (T/R Bit). This
same data can now be transferred from this RAM location
to the OUTPUT FIFO Buffer and compared with the data
originally written to the INPUT FIFO Buffer. Providing
this type of testing provides a high degree of functional
verification.
Operation Register: This register contains information
provided by the subsystem to control the interface. This
register sets up the mode of operation for the interface (BC
or RT), selects the available options (BUS Select and Auto
Retry), and contains information for reading or writing data
This test implementation not only verifies MIL-STD-1553
SCD7005 Rev C
10
protocol compliance (proper sync character, 16 data bits,
Manchester 11 coding, odd parity, and contiguous word
checking), but also the inclusion of a bit by bit comparison
of transmitted data has been added. The added circuitry is
used to insure that the internal functional blocks, encoder,
decoder, and internal control circuitry are functioning
properly. The internal data path can be verified as fault free
by comparing the returned data word with the supplied
data. The most effective data pattern to accomplish this is
HEX AA55, since each bit is toggled (8 bit internal
highway) on a high/low byte basis. Total time to complete
the test is 89 microseconds. TEST ENABLE (bit 9) must
remain low this entire time to ensure proper operation of
the self test.
must then determine whether or not the word count or
subaddress is to be considered illegal by the RT. If either of
them is considered illegal, the subsystem must produce a
negative-going pulse called MEREQ. The negative-going
edge of MEREQ must occur within 500 nSec of the falling
edge of INCMD .
Subsystem Flag and Terminal Flag Bits
The conditions that cause the Subsystem Flag and
Terminal Flag Bits in the Status Word to be reset may be
controlled by the subsystem using the ENABLE, BIT
DECODE, NEXT STATUS, and STATUS UPDATE inputs.
If ENABLE is inactive (high), then the Terminal Flag and
Subsystem Flag behavior is the same as described below:
(i.e. the other three option lines are disabled).
USE OF A10 AND A10IN
Subsystem Flag Bit: This bit is reset to logic zero by
a power up initialization or the servicing of a legal mode
command to reset the remote terminal (code 01000).
The standard configuration of the ACT7005/6 Series
divides the INTERNAL RAM into separate RECEIVE and
TRANSMIT sections. For this configuration A10 is
connected to A10IN. When A10 is high, it addresses the
TRANSMIT section; when low, the RECEIVE sections.
A10IN is the address input to the INTERNAL RAM.
This bit shall be set in the current status register if the
subsystem error line, SSERR, from the subsystem ever
goes active low. This bit shall also be set if an
RT/subsystem handshaking failure occurs. This bit,
once set, shall be repeatedly set until the detected error
condition is known to be no longer present.
The interface may be configured with one common
section for both RECEIVE and TRANSMIT data. To
configure this, A10 is not connected, and A10IN is fixed at
either a logic high or low. This bit can also be controlled by
the subsystem to provide double buffering of the contents
of common RAM section for receive and transmit data. If
A10 and A10IN are not directly connected together but
gated together, then no more than 100nsec of propagation
delay should be introduced.
Terminal Flag Bit: This bit is reset to logic zero by a
power up initialization or the servicing of a legal mode
command to reset the remote terminal (code 01000).
This bit can be set to logic one in the current status
register in four possible ways:
a) If the RX detects any message encoding or
content error in the terminals transmission. A
loop test failure, LTFAIL, will be signalled
which shall cause the Terminal Flag to be set
and the transmission aborted.
b) If a transmitter timeout occurs while the
terminal is transmitting.
c) If a remote terminal self test fails.
d) If there is a parity error in the hard wired
address to the RX chip.
NON-REGISTER OPERATIONAL COMMANDS
There are six operational commands that are not register
read or write operations. These commands are summarized
in Table 8. The two execute operations are dependent on
the contents of the OPERATION register. The address
codes for all the operational commands are summarized in
the 8 bit and 16 bit l/O OPERATIONAL tables.
This bit, once set, shall be repeatedly set until the
detected error condition is known to be no longer
present. The transmission of this bit as a logic one can
be inhibited by a legal mode command to inhibit
terminal flag bit (code 00110). Similarly, this inhibit can
be removed by a mode command to override inhibit
terminal flag bit (code 00111), a power up initialization
or a legal mode command to reset remote terminal (code
01000).
OPTIONAL STATUS WORD CONTROL
Message Error Bit
The ACT7005/6 monitors all receptions for errors and sets
the Message Error Bit as prescribed in MIL-STD-1553B.
The subsystem designer may, however, exercise the option
of monitoring for illegal commands and forcing the
Message Error Bit to be set.
If ENABLE is held low, then the three options described
below are available and are essentially independent. Any,
all, or none may be selected. Also, reporting of faults by the
subsystem requires that SSERR be latched (not pulsed) low
until the fault is cleared.
The word count and subaddress lines for the current
command are valid when INCMD goes low. The subsystem
SCD7005 Rev C
11
Resetting SSF and TF on Receipt of Valid
Commands
If ENABLE is selected and the other three option lines are
held high, then the Status Word Register will be reset on
receipt of any valid command with the exception of
Transmit Status and Transmit Last Command. Note that in
this mode, the TF will never be seen in the Status Word,
and the SSF will only be seen if SSERR is latched low.
Also note that the SSF will not be seen in response to
Transmit Status or Transmit Last Command if the
preceding Status Word was clear, regardless of actions
taken on the SSERR line after the clear status transmission.
Status Register Update at Fault Occurrence
If STATUS UPDATE is selected (held low), then the TF or
SSF will appear in response to a Transmit Status or
Transmit Last Command issued as the first command after
the fault occurs. Any other command (except as noted in
the Preserving the BIT Word section) will reset the TF and
SSF. Repeated Transmit Status or Transmit Last Command
immediately following the fault will continue to show the
TF and/or SSF in the Status Word. Note that this behavior
may not meet the "letter-of-the-spec" as described in
MIL-STD-1553B, but is considered the "preferred"
behavior by some users.
TF and SSF Reporting in the Next Status Word –
After the Fault
If NEXT STATUS is selected (held low), then the TF or
SSF will appear in response to the very next valid
command after the fault except for Transmit Status or
Transmit Last Command. The flag(s) will be reset on
receipt of any valid command following the status
transmission with the flag(s) set except for Transmit Status,
Transmit Last Command, or as noted in the following
section on Preserving the BIT Word.
Preserving the BIT Word
In order to preserve the Transmitter Timeout Flag,
Subsystem Handshake Failure, and Loop Test Failure Bits
in the BIT Word, it is necessary to select BIT DECODE
(hold it low). This will prevent resetting those bits if the
Transmit Bit Word Mode Command immediately follows
the fault or follows a Transmit Last Command or Transmit
Status immediately following the fault. It will also prevent
resetting the TF and SSF Bits in the Status Word. Any other
valid commands will cause those BIT Word Bits and the
Status Word Bits to be reset.
SCD7005 Rev C
12
Name
Use
INT #1
GOOD BLOCK (RT)
Indicates reception of a valid block of data. The RECEIVE COMMAND WORD is loaded
in RCV CMD WD Register. This interrupt is issued after the new block of data is moved
into the Internal RAM.
VALID (BC)
Indicates that the Bus Controller has initiated and observed a valid message transfer on the
1553 data bus.
INT #2
VALID TRANS (RT)
Indicates reception of a valid TRANSMIT COMMAND WORD. The TRANSMIT
COMMAND WORD is loaded in CMD WD Register. Note: This interrupt does not
necessarily indicate that the transmitted data was received by the bus controller.
INVALID (BC)
Indicates that the Bus Controller has initiated a message transfer on the data bus, but the
message traffic has been deemed invalid.
SYNC NO DATA
Indicates reception of a valid mode command SYNCHRONIZE WITHOUT DATA
SYNC W/DATA
Indicates reception of a valid mode command SYNCHRONIZE WITH DATA. The
synchronize data word is loaded into the SYNC/STAT WD #2/RMD REGISTER. This
interrupt will not be issued if a word count high or low error occurs.
DONE
This interrupt is issued in response to an I/0 command from the subsystem. In response to
an I/0 load OUTPUT buffer command, it indicates that the complete 32 word message
block (SUBADDRESS) has been loaded into the OUTPUT FIFO buffer. In response to an
I/0 load internal RAM from INPUT FIFO buffer command, it indicates the full message (1
to 32 WORDS) has been loaded.
TIMING
a. In response to an I/0 load OUTPUT buffer: 16.5 to 33 µsec.*
b. In response to an I/0 load RAM from INPUT buffer: 16.5 to 33 µsec for 32
WORDS*, for SHORTER LOAD OPERATIONS SUBTRACT 0.5 µsec per (16 bit)
word, i.e., 17 µsec to 0.5 µsec for single word.
*NOTE:
In the unusual case where a superceding transmit command on the redundant bus occurs at
the returned status time for a valid 32 word receive, simultaneously with an I/0 transfer
request, the DONE interrupt may be delayed for an additional 16.5 usec.
BUFF EF
This flag may be used to speed up read data operation in response to an I/0 load OUTPUT
FIFO buffer command. The BUFF EF flag will go high when the first word is loaded into
the OUTPUT FIFO buffer. The word may be read at that time. Please see Figure 6.
MODERESET
Indicates reception of a valid RESET mode command.
TABLE 6 – DISCRETE INTERRUPTS SUMMARY
SCD7005 Rev C
13
Name
Use
VECTOR
Indicates that a transmit VECTOR mode command has been received. VECTOR
DATA is transmitted from VW/CMD WD #2/AMD Register.
DBCREQ
Indicates acceptance of DYNAMIC BUS CONTROL COMMAND REQUEST
Note: RTU will not accept valid DBC mode command unless DBCACC bit
is set low in the OPERATION Register.
RETRY
Indicates that an error has occurred in the data transfer and that a retry will be
performed if the retry option is selected. If all retries that were selected fail, INVALID
TRANSFER INTERRUPT would be asserted on the final failure.
SELF TEST
Indicates that the INITIATE SELF TEST mode command is being serviced.
PASS
Active low pulse output signal which indicates that a sub-system initiated self-test
(on-or off-line) operation has been sucessfully completed. This interrupt will be issued
approximately 90µs after the self-test operation has been triggered.
TABLE 6 – DISCRETE INTERRUPTS SUMMARY (CONTINUED)
Bit
0-4
Name
SA BITS
Function
SUBADDRESS BITS
Define SUBADDRESS MESSAGE BLOCK in INTERNAL RAM.
BIT
0
1
2
3
4
SUBADDRESS BIT
SA0 (LSB)
SAl
SA2
SA3
SA4 (MSB)
These bits correspond directly to 1553B definition in the command word. Although
SUBADDRESSES 00000B and 11111B are illegal in 1553B, message blocks specified by
them are both READABLE and WRITABLE by the SUBSYSTEM. They are not
accessible from the 1553B BUS.
5
T/R BIT
6
I/O
TRANSMIT/RECEIVE BIT points INPUT/OUTPUT OPERATIONS to either the
TRANSMIT SECTION or RECEIVE SECTION of the INTERNAL RAM.
INPUT/OUTPUT BIT DEFINES DIRECTION OF DATA TRANSFER
1. SET HIGH: INPUT OPERATION
An EXECUTE operation will transfer the Data currently loaded in the input FIFO
buffer to the specified message block (SUBADDRESS) in the internal RAM.
Between 1 and 32 data words must be loaded in the input FIFO buffer when using an
EXECUTE command with this bit set.
2. SET LOW: OUTPUT OPERATION
EXECUTE operation will transfer a complete block of data (32 words) to the output
FIFO buffer from the specified subaddress of internal RAM.
TABLE 7 – OPERATIONAL REGISTER
SCD7005 Rev C
14
Bit
Name
Function
7
BUSY BIT
RTU BUSY
HIGH- BUSY
LOW - NOT BUSY
MASTER RESET SETS BIT HIGH
8
RT/BC
9
Transaction/
Test
10
LT Local
Loop Test Local Bit (Used in conjunction with BIT 9). This signal selects the self test
path. When set LOW, the internal digital path is selected. When set HIGH, the external
path, including transceivers, is selected.
11
Bus Select
Bus Select (Bus Controller Only). When set high, Bus 1 is selected. When set LOW, Bus
0 is selected.
12
Normal/RT-RT
13
SERV REQ/
Auto-Retry
(LSB)
Service Request/Auto-Retry (LSB) Bit.
RT MODE: A LOW in this bit will cause the service request
bit in the status word to be set.
BC MODE: This is the LSB of the Auto-Retry options. See
table on this page, Bit 14
14
SERR
Auto-Retry
(MSB)
Subsystem Error/Auto-Retry (MSB) Bit.
RT MODE: A LOW in this bit will cause a Subsystem Error
Bit in the status word to be set.
BC MODE: This is the MSB of the Auto-Retry option
Remote Terminal/Bus Controller Bit. This line, when set HIGH, causes the hybrid to
function as a Remote Terminal. When set LOW, it will function as a Bus Controller.
Master Reset sets this bit HIGH
Transaction/Test Mode Bit. When this bit is set high, normal transactions will be handled,
eg., BC to RT, RT to BC, RT to RT. If this bit is set low and a trigger transaction is issued,
the self-test will be performed for the MIL-STD-1553 protocol chip.
Normal/Remote Terminal-Remote Terminal Bit. When set HIGH, BC to RT and RT to
BC transfers are performed. When set LOW RT to RT transfers are performed. Two
command words are required and two returned status words will be expected.
AUTO-RETRY OPERATIONS
Options selected:
15
DBCACC/
Auto-Retry
Other Bus
Auto-Retry Other Bus
Bit 15
Bit 14
Bit 13
0
1
0
0
1
1
0
1
0
1
No Retry
P
P/P
P/P/P
No Retry
S
P/S
P/S/S
Dynamic Bus Control Accept/Auto-Retry Bus Bit.
RT MODE: This bit should be LOW if the subsystem is able to accept
control of the bus, if offered.
BC MODE: This bit should be HIGH if an invalid transfer is to be
retried according to the selected auto-retry option listed
above.
TABLE 7 – OPERATIONAL REGISTER (con’t)
SCD7005 Rev C
15
Operation
Function
RESET
RESET INPUT/OUTPUT BUFFERS
This command clears both the input and output FIFO buffers. The BUFF EF flag will go
low indicating the output buffer is empty.
READ OUTPUT
DATA BUFFER
READ OUTPUT FIFO
READS the data moved from the INTERNAL RAM in response to an UNLOAD execute
operation. The order of the data words corresponds to the same order that they would be
received on the 1553B bus. That is the first data word read is the first data word following
the COMMAND word. In the 8 bit mode the HIGH BYTE is read FIRST.
WRITE OUTPUT
DATA BUFFER
WRITE INPUT FIFO
WRITES the data that will be moved into the INTERNAL RAM in response to a LOAD
execute operation. The order of the data words corresponds to the same order that they
would be transmitted on the 1553B bus. That is the first data word written is the first data
word transmitted following the status word. In 8 bit mode the HIGH BYTE is written
FIRST.
EXECUTE OP
EXECUTES OPERATION SPECIFIED IN OPERATION REGISTER
EXECUTE OP
WITH RPT OPTION
1.
I/O BIT HIGH
Data currently in INPUT FIFO BUFFER is loaded into the INTERNAL RAM
block specified by the T/R BIT and SUBADDRESS FIELD of the OPERATION
REGISTER. The INPUT BUFFER must have at least one data word. The DONE
interrupt is pulsed when the operation is completed.
2.
I/O BIT LOW
An entire block of data (32 words) specified by the T/R and the SUBADDRESS
field of the OPERATION REGISTER is unloaded from the INTERNAL RAM into
the UTPUT FIFO BUFFER. The BUFF EF Flag goes high when the first data word
is moved into the OUTPUT BUFFER. The DONE interrupt is pulsed when the
complete message has been moved.
EXECUTES OPERATION SPECIFIED IN OPERATION REGISTER WITH REPEAT
OPTION
TRIGGER TRANSACTION
TRIGGER TEST
1.
I/O BIT HIGH
Data previously written into the INPUT BUFFER is loaded into a new INTERNAL
RAM block specified by the T/R and SUBADDRESS field of the OPERATION
REGISTER. This operation allows a block of data loaded in the INPUT BUFFER
to be repeatedly copied into multiple subaddresses of the INTERNAL RAM
without the subsystem having to reload the data. The DONE interrupt is pulsed
when the operation is completed. The intent of the operation is to minimize the
time required to initialize the INTERNAL RAM.
2.
I/O BIT LOW
Operation identical to EXECUTE OP. WITHOUT RPT option.
TRANSACTION/TEST TRIGGER
This signal executes the desired Bus Controller Function or test of the protocol section
determined by the Operation Register.
TABLE 8 – NON-REGISTER OPERATIONAL COMMANDS
SCD7005 Rev C
16
Operation
RD
WT
DS
AD3
AD2
AD1
AD0
x
*P
P
1
1
P
1
1
1
1
1
1
x
1
1
P
P
1
P
P
P
P
P
P
1
0
0
0
0
0
0
0
0
0
0
0
x
0
0
0
0
1
1
1
1
1
1
1
x
0
0
0
0
1
1
0
0
0
1
1
x
0
0
0
0
1
1
0
1
1
0
0
x
1
0
1
0
0
0
0
0
1
1
0
P
P
P
P
P
P
1
1
1
1
1
1
1
1
P
P
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
0
1
1
1
1
0
0
1
1
1
1
1
1
1
0
1
0
1
0
1
0
BC AND RT MODE
No Operation-l/O Bus Tri-stated
Read Operation Reg. High Byte
Read Operation Reg. Low Byte
Write Operation Reg. High Byte
Write Operation Reg. Low Byte
Read Output FIFO (High Byte First)
Write Input FIFO (High Byte First)
Execute Operation (Load/Unload RAM)
Execute Operation with Repeat
Reset Input FIFO
Reset Output FIFO
Reset Input and Output FIFOS
RT MODE ONLY
Read RT Command Word Reg. High Byte
Read RT Command Word Reg. LowByte
Read Receive Command Reg. High Byte
Read Receive Command Reg. LowByte
Read SYNC Data Reg. High Byte
Read SYNC Data Reg. Low Byte
Write Vector Word Reg. High Byte
Write Vector Word Reg. Low Byte
*P = Active Low Strobe
Note: When operating in 8-bit mode it is recommended that FIFO access be confined to even numbers of Read or Write
operations only. Failure to conform to this can result in incorrect data being transferred to internal RAM.
BC MODE ONLY
Read Status Word #1 Reg. High Byte
Read Status Word #1 Reg. Low Byte
Read Status Word #2/RMD Reg. High Byte
Read Status Word #2/RMD Reg. Low Byte
Write Command Word #1 Reg. High Byte
Write Command Word #1 Reg. Low Byte
Write Command Word #2/AMD Reg. High Byte
Write Command Word #2/AMD Reg. Low Byte
Trigger Transaction
P
P
P
P
1
1
1
1
1
1
1
1
1
P
P
P
P
P
0
0
0
0
0
0
0
0
0
TABLE 9 – 8-BIT MODE I/O OPERATIONS
SCD7005 Rev C
17
0
0
0
0
0
0
0
0
1
0
0
1
1
0
0
1
1
0
1
1
1
1
1
1
1
1
0
1
0
1
0
1
0
1
0
1
Operation
RD
WT
DS
AD3
AD2
AD1
AD0
x
*P
1
1
1
P
1
1
1
1
x
1
P
P
P
1
P
P
P
P
1
0
0
0
0
0
0
0
0
0
x
0
0
1
1
1
1
1
1
1
x
0
0
0
0
1
1
0
1
1
x
0
0
0
1
1
1
1
0
0
x
0
0
0
0
0
0
1
1
0
P
P
P
1
1
1
1
P
0
0
0
0
0
0
0
0
1
0
1
1
0
1
1
1
0
0
0
0
P
P
1
1
1
1
1
P
P
P
0
0
0
0
0
0
0
0
0
1
0
1
0
1
0
1
1
1
1
0
0
0
0
0
1
RT AND BC MODE
No Operation - I/O Bus Tri-Stated
Read Operation Register
Write Operation Register
Execute Operation (Load/Unload Ram)
Execute Operation with Repeat
Read Output FIFO
Write Input FIFO
Reset Input FIFO
Reset Output FIFO
Reset Input and Output FIFO
RT MODE ONLY
Read RT Command Word Register
Read Receive Command Register
Read SYNC Data Register
Write Vector Word Register
BC MODE ONLY
Read Status Word #1 Register
Read Status Word #2/RMD Register
Write Command Word #1 Register
Write Command Word #2/AMD Register
Trigger Transaction
*P = Active Low Strobe
TABLE 10 – 16-BIT MODE I/O OPERATIONS
SCD7005 Rev C
18
Pin #
Signal Name
Signal Description
16
VDD
Digital Supply Voltage
87
VDD
Digital Supply Voltage
2
GND
Digital Grounds
34
N/C / SERR
N/C - ACT7005, SERR on ACT7006 - Subsystem Error. When low sets
the SSF Bit in the RT’s return status word.
80
GND
Digital Grounds
38
VccL (A)
Transceiver A +5VDC Supply Voltage
44
GND (A)
Digital Ground A
43
GND (A)
Analog Ground A
39
N/C
No Connection
41
GND (A)
Transceiver A Output Ground
53
VccL (B)
Transceiver B +5VDC Supply Voltage
47
GND (B)
Digital Ground B
48
GND (B)
Analog Ground B
52
N/C
No Connection
50
GND (B)
Transceiver B Output Ground
81
AD0
82
AD1
83
AD2
Address Inputs
AD0 - LSB
AD3 - MSB
These four signals provide the address codes that control the operation of
the interface.
84
AD3
85
A10 IN
A10 IN is the address input to the internal RAM.
86
A10 OUT
A10 OUT buffered TX/RX bit when tied to A10 IN segregates the 2k by
16 RAM into two 1k by 16 blocks of memory: one for Receive, the other
for Transmit Data.
23
BCSTEN
Broadcast Enable. When low, the recognition of Broadcast Command is
prevented on the specified bus.
25
BIT DECODE
Built-ln Test Decode. When held low, prevents resetting TXTO Bit,
HSFAIL Bit, and LTFAIL Bit in the Bit Word (as well as TF and SSF Bits
in the Status Word) upon receipt of a Transmit Bit Word Mode
Command.
59
BUFF EF
Buffer Empty Flag - goes low when the output FIFO Buffer is empty. Will
transition to the high state when the first word appears in the Buffer.
TABLE 11 – PIN NUMBER DESCRIPTION
SCD7005 Rev C
19
Pin #
Signal Name
Signal Description
1
CLOCK
6 MHz Master Clock.
42
DATA CHA
DATA CHANNEL A. (BUS 0). This is the combined signals, RX Data In
and TX Data Out, that connect to the IN phase primary terminal of the
Bus Transformer.
40
DATA CHA
DATA CHANNEL A. (BUS 0) This is the combined signals RX Data In
and TX Data Out, that connect to the OUT of phase primary terminal of
the Bus Transformer.
49
DATA CHB
Same as DATA CHA, except for Channel B. (BUS 1).
51
DATA CHB
Same as DATA CHA, except for Channel B. (BUS 1).
64
DB0
I/O DATA BUS. Data Bus for all SUBSYSTEM
READ and WRITE OPERATIONS.
65
DB1
66
DB2
67
DB3
68
DB4
69
DB5
70
DB6
71
DB7
72
DB8
73
DB9
74
DB10
75
DB11
76
DB12
77
DB13
78
DB14
79
DB15
56
DBCREQ
Dynamic Bus Control Request. If OPERATION Register bit i5 is set
LOW, this line will pulse LOW in response to a Valid Dynamic Bus
Control Mode Command, indicating ACCEPTANCE of Bus Control
Function.
90
DS
Device Select. This signal must be low before the interface can be
selected for an I/O Read or Write function. The I/O Data Bus will remain
tri-stated, no operations will be executed when this signal is high.
60
DONE
Low Pulse Indicates an I/O Operation has completed
16 BIT MODE
8 BIT MODE
DB0 = LSB
DB15 = MSB
DB0/DB8 = LSB
DB7/DB15 = MSB
When used in 8 BIT MODE the data bus must be
connected as follows:
DB0 TO DB8
DB1 TO DB9
DB2 TO DB10
DB3 TO DB11
DB4 TO DB12
DB5 TO DB13
DB6 TO DB14
DB7 TO DB15
TABLE 11 – PIN NUMBER DESCRIPTION (con’t)
SCD7005 Rev C
20
Pin #
Signal Name
Signal Description
24
ENABLE
Enable. When held low, enables Bit Decode, Next Status, and Status
Update program lines.
62
INT #l
Good Block (RT) / VALID TRANSFER (BC)
63
INT #2
VALID Transmit (RT) / INVALID TRANSFER (BC)
33
LTFAIL
Loop Test Fail. This line goes low if any error in the terminals own
transmitted waveform is detected or if any parity error in the hardwired
RT address is detected.
3
MEREQ
Message Error Request. To set the Message Error bit in the Status Word,
this signal must go low within 650 nsec of INCMD going low and remain
valid for the DURATION of INCMD.
57
MODEREST
Mode Reset. This line pulses low for 500 ns on completion of the
servicing of a valid Reset Remote Terminal Mode Command.
28
M16/8
Programs Interface for 8 Bit or 16 Bit Data Buses.
16/8 = LOW (0) 8 BIT MODE
16/8 = HIGH (1) 16 BIT MODE
55
NBGT
New Bus Grant. Pulses low whenever a new command is accepted.
26
NEXT STATUS
Next Status. When held low, causes TF or SSF to appear in very next
Status Word after fault occurrence (except for Transmit Status or
Transmit Last Command).
58
PASS
Pass. Interrupt indicates that the protocol self-test has completed with no
faults.
88
RD
Read Strobe. Must GO LOW together with DS to perform a READ
OPERATION. Note: WT STROBE MUST BE HIGH.
61
RETRY
Retry Interrupt
31
RESET
System MASTER Reset. When low resets all registers and
INPUT/OUTPUT FIFO buffers. Minimum Low Time for reset 0.5 µsec.
17
RTADPAR
RT Address Parity. This must be hardwired by the user to give odd parity.
22
RTAD0
RT Address Lines. These should be hardwired
by the user. RTAD4 is the most significant bit.
21
RTAD1
20
RTAD2
19
RTAD3
18
RTAD4
32
RTADER
Remote Terminal Address Error. This line goes low if an error is detected
in the RT address parity of the selected receiver. Any receiver detecting
an error in the RT address will turn itself off.
TABLE 11 – PIN NUMBER DESCRIPTION (con’t)
SCD7005 Rev C
21
Pin #
Signal Name
Signal Description
11
SA0
13
SA1
15
SA2
14
SA3
12
SA4
54
SELFTEST
Self Test Interrupt indicates that the Initiate Self Test Mode Command is
being served.
27
STATUSUPDATE
Status Update. When held low, causes TF or SSF to appear in Status
Word response to Transmit Status or Transmit Last Command issued
immediately after fault occurrence.
36
SYNCND
Synchronize No Data Interrupt
37
SYNCWD
Synchronize with Data Interrupt
29
TEST #l
Test #1 Factory Test Point (Do not connect).
30
TEST #2
Test #2 Factory Test Point (Do not connect).
8
TX/RX
Transmit/Receive. The state of this line informs the subsystem whether it
is to transmit or receive data. The signal is valid while INCMD is low.
35
VECTOR
Vector Interrupt
4
WC0
5
WC1
Word Count. These Five lines specify the
requested number of Data Words to be received
or transmitted. Valid when INCMD is low. WC4
is the most significant bit.
7
WC2
9
WC3
10
WC4
89
WT
Write Strobe. Must GO LOW together with DS to perform a write
operation. NOTE: RD must be high.
6
INCMD
IN COMMAND. Goes low when the interface is servicing a valid
command. Can be utilized to enable external firm-ware to illegalize
subaddresses and mode command not allowed by
Subaddress. These five lines are a label for the
data being transferred. Valid when INCMD is
low. SA4 is the most significant bit.
TABLE 11 – PIN NUMBER DESCRIPTION (con’t)
SCD7005 Rev C
22
Symbol
Parameter
Min
Typ
Max
Units
Notes
tWPW
Write Pulse Width
50
nsec
1, 2
tRPW
Read Pulse Width
50
nsec
3
tAS
Address Set Up Time
15
nsec
tAH
Address Hold Time
15
nsec
tDS
Write Data Set Up Time
15
nsec
tDH
Write Data Hold Time
0
nsec
tDA
Read Data Access Time
tIPW
Interrupt Pulse Width
140
tREC
Recovery Time
100
160
50
nsec
180
nsec
nsec
Conditions: (-55°C < TA < +125°C) VCC = +5.0V ± 10%
Notes: 1. Write pulse width tWPW is the time when both DS and WT are simultaneously low. Either DS or WT may go low or
return high first.
2. Write hold time:
tDH = 0 for tWPW > 450nsec
tDH = 10nsec for 50nsec < tWPW < 450nsec
3. Read pulse time tRPW is the time where both DS and RD are simultaneously low. Either DS or RD may go low or
return high first.
4. Refer to “Discrete Interrupt” text for further information.
TABLE 12 – AC ELECTRICAL CHARACTERISTICS
SCD7005 Rev C
23
2
4
I/O Write Timing
tWPW
tREC
DS
WT
AD0 - AD3
tAS
tAH
DB0 - DBF
tDH
tDS
I/O Read Timing
tREC
tRPW
DS
RD
AD0 - AD3
tAS
tAH
DB0 - DBF
tDA
Output Interrupts
GOOD BLOCK
SYNC W/DATA
SYNC NO DATA
VALID TRANS
tIPW
FIGURE 4 – SUBSYSTEM INTERFACE TIMING
SCD7005 Rev C
24
Signal Name
Function
A0 - A3
INPUT ADDRESS
A0 = LSB
A3 = MSB
These four signals provide the address codes that control the operation of the interface.
DS
DEVICE SELECT
Used in conjunction with the address signals. The
input/output interface data bus will remain tri-stated
and no operation will be executed when this signal
is high, regardless of the state of the address signals.
DS = LOW (0) INTERFACE SELECTED
DS = HIGH (1) INTERFACE NOT SELECTED
DB0-DB15
I/O DATA BUS
Data Bus for all SUBSYSTEM READ and WRITE OPERATIONS.
16 BIT MODE
8 BIT MODE
DB0 = LSB
DB15 = MSB
DB0/DB8 = LSB
DB7/DB15 = MSB
When used in 8 BIT MODE the data bus must be connected as follows:
DB0 TO DB8
DB1 TO DB9
DB2 TO DB10
DB3 TO DB11
16/8
DB4 TO DB12
DB5 TO DB13
DB6 TO DB14
DB7 TO DB15
PROGRAMS INTERFACE FOR 8 BIT OR 16 BIT DATA BUSES
16/8 = LOW (0)
8 BIT MODE
16/8 = HIGH (1)
16 BIT MODE
MASTER RESET
SYSTEM RESET
When low resets all registers and INPUT/OUTPUT buffers. Minimum Low Time for reset =
0.5 µsec.
WT
WRITE STROBE
Must GO LOW together with DS to perform a WRITE OPERATION.
NOTE: RD MUST BE HIGH.
RD
READ STROBE
Must GO LOW together with DS to perform a READ OPERATION.
NOTE: WT STROBE MUST BE HIGH.
INTERRUPTS
Refer to DISCRETE INTERRUPT TABLE.
TABLE 13 – SUBSYSTEMS INTERFACE SIGNALS
SCD7005 Rev C
25
LOAD
OPERATION
REG.
SET:
RESET FIFO
RESET INPUT FIFO @ ADDRESS = BH
LOAD FIFO
WITH DATA
LOAD INPUT FIFO @ ADDRESS = EH
(MAX = 32 WORDS)
EXECUTE
OPERATION
WRITE AN ARBITRARY WORD
TO ADDRESS = 8H
DONE
INTERRUPT ?
SUBADDRESS BITS @ ADDRESS = 0H
T/R BIT = 1
(16 BIT MODE)
I/O BIT = 1
NO
YES
DONE
FIGURE 5 – FLOWCHART # 1 – LOAD DATA INTO TRANSMIT RAM
SCD7005 Rev C
26
SET:
LOAD
OPERATION
REG.
SUBADDRESS BITS @ ADDRESS = 0H
T/R BIT = 0
(16 BIT MODE)
I/O BIT = 0
RESET OUTPUT FIFO @ ADDRESS = DH
RESET
OUTPUT
FIFO
WRITE AN ARBITRARY WORD TO ADDRESS = 8H
EXECUTE
OPERATION
*FIFO CAN BE READ OUT BEFORE THE DONE INTERRUPT. FIFO
READ CAN COMMENCE AS SOON AS THE BUFF EF SIGNAL
GOES HIGH. WORDS CAN BE READ AT A MAXIMUM RATE OF
500ns/WORD THEREAFTER.
DONE
INTERRUPT ?
NO
YES
READ
OUTPUT
FIFO
READ OUTPUT FIFO @ ADDRESS = EH
(MAX = 32 WORDS)
DONE
FIGURE 6 – FLOWCHART # 2 - UNLOAD DATA FROM RECEIVE RAM
SCD7005 Rev C
27
Pin
#
Pin
#
Function
Function
Pin
#
Function
1
6MHZ CLOCK INPUT
31
RESET [MASTER]
61
RETRY
2
GND [LOGIC]
32
RTADER
62
GOODBLK / VALIDTXFR
3
MEREQ
33
LTFAIL
63
VALIDXMIT / INVLDTXFR
4
WC0
34
N/C - ACT7005 / SERR - ACT7006
64
DB0
5
WC1
35
VECTOR
65
DB1
6
INCMD
36
SYNCND
66
DB2
7
WC2
37
SYNCWD
67
DB3
8
T/R
38
VCCL (A) [TX/RX / LOGIC]
68
DB4
9
WC3
39
N/C
69
DB5
10
WC4
40
DATA CH A
70
DB6
11
SA0
41
OUTPUT GND A
71
DB7
12
SA4
42
DATA CH A
72
DB8
13
SA1
43
ANALOG GND A
73
DB9
14
SA3
44
DIGITAL GND A
74
DB10
15
SA2
45
N/C
75
DB11
16
+5V [VDD]
46
N/C
76
DB12
17
RTADPAR
47
DIGITAL GND B
77
DB13
18
RTAD4
48
ANALOG GND B
78
DB14
19
RTAD3
49
DATA CH B
79
DB15
20
RTAD2
50
OUTPUT GND B
80
GND [LOGIC]
21
RTAD1
51
DATA CH B
81
AD0
22
RTAD0
52
N/C
82
AD1
23
BCSTEN
53
VCCL (B) [TX/RX / LOGIC]
83
AD2
24
ENABLE
54
SELF TEST
84
AD3
25
BIT DECODE
55
NBGT
85
A10 [IN]
26
NEXT STATUS
56
DBCREQ
86
A10 [OUT]
27
STATUS UPDATE
57
MODE RESET
87
+5V [VDD]
28
MODE 16/8
58
PASS
88
RD
29
TEST1
59
BUFF EF
89
WT
30
TEST2
60
DONE
90
DS
TABLE 14 – ACT7005 / 7006 DIP PACKAGE PINOUTS
SCD7005 Rev C
28
ORDERING INFORMATION
Model Number
ACT7005
Screening
DESC Part Number
Package
Pending
2.40" x 1.60" Ceramic
Plug In
Military Temperature, -55°C to +125°C,
Screened to the individual test methods of
MIL-STD-883
ACT7006
PLUG IN PACKAGE OUTLINE
2.400
MAX
.225
MAX
1.600
MAX
Lead 1 & ESD
Designator
.200
MIN
.135
2.200
.090
Pin 3
Pin 1
.050
TYP
Pin 43
Pin 45
Pin 44
Pin 2
.018 DIA
TYP
1.300 1.100
Pin 89
Pin 47
Pin 90
Pin 88
.100
TYP
Pin 48
Pin 46
2.100
.135
PLAINVIEW, NEW YORK
Toll Free: 800-THE-1553
Fax: 516-694-6715
INTERNATIONAL
Tel: 805-778-9229
Fax: 805-778-1980
NORTHEAST
Tel: 603-888-3975
Fax: 603-888-4585
SE AND MID-ATLANTIC
Tel: 321-951-4164
Fax: 321-951-4254
WEST COAST
Tel: 949-362-2260
Fax: 949-362-2266
CENTRAL
Tel: 719-594-8017
Fax: 719-594-8468
www.aeroflex.com
[email protected]
Aeroflex Microelectronic Solutions reserves the right to
change at any time without notice the specifications, design,
function, or form of its products described herein. All
parameters must be validated for each customer's application
by engineering. No liability is assumed as a result of use of
this product. No patent licenses are implied.
Our passion for performance is defined by three
attributes represented by these three icons:
solution-minded, performance-driven and customer-focused
SCD7005 Rev C
29